This study investigated the effects of several factors - stimulus color, background color, and predicted depth - that affect depth perception in stereoscopic displays. For this study, two experiments were conducted; in the first experiment, the subjects were asked to indicate the depth perceived from presented image(rectangle) using matching mark, and in the second experiment, the subjects were asked to adjust one image(controllable rectangle) to have the same perceived depth as the other image(fixed rectangle) using keyboard. The depth perceived under various combination of levels of these factors was compared with depth predicted by the geometry of streopsis. Through two experiments, we found that stimulus color, predicted depth, and interaction between stimulus color and background color affected perceived depth significantly, and that red was perceived to be closest to the observer followed by yellow, green, and then blue.
The interactions between two-dimensional and three-dimensional stimulus configurations on visually induced self-motion perception (vection) were examined. The experiment revealed that there is no 2D-3D interaction, and vection strength is determined solely by the size of the moving background stimulus, which should be a primary factor in inducing vection.
This study was investigated whether the perceived depth was changed depending on the measurement methods. In the method of direct comparison, virtual object with one of the various binocular disparities was presented in the frontal space with LEDs which were used for depth estimation for a binocular stimulus, while in the method of indirect comparison, visual object was presented in the frontal space but the LEDs were placed rightward at the angle of 45 degree from the mid-sagittal line. In these experimental setup, the depth of binocular stimulus was directly matched that of LED in direct comparison condition. In indirect comparison condition, however, observer estimated the depth of binocular stimulus, turned one's head rightward to the array of LEDs and turned on the LED which was supposed to be the same depth as binocular stimulus. Additionally, it was investigated whether the perceived depth was different depending on observer's stereo acuity. The results showed that perceived depths measured in the direct comparison were more similar to the depth predicted from geometry than those in the indirect comparison, and that the perceived depths from observers with high stereo acuity were similar to the predicted depth from geometry those from observers with low stereo acuity. These results indicated that stereoscopic depths of the binocular stimuli would vivid and compelling when binocular stimuli was simultaneously presented with real objects in the same visual space, like a mixed reality.
Kim, Young-Sam;Yu, Yun-Cho;Oh, Inn-Kun;Kim, Myung-Dong
Journal of Physiology & Pathology in Korean Medicine
/
v.21
no.2
/
pp.444-452
/
2007
Acupuncture treatment cures disease by regulating the functional excessiveness or deficiency which occurs in the meridian and visceral organs, and by letting stagnated Qi and Blood flow through the whole body and then controlling Qi. Whether or not to have Qi feeling is the main factor needed to manifest the efficacy of acupuncture. So it needs the very stimulus to make Qi felt rather than the simple stimulus. In order to have Qi feeling, it needs to acupuncture a patient according to patient's thinness or fatness, constitution, richness or poverty and age. And also it needs to vary the way to acupuncture a patient according to meridian, kinds of pulse, degrees of disease, new or old diseases, seasons with a disease and local areas of disease. In order to ascertain that it is important for the quality and quantity of acupuncture stimulus and the state of feeling acupuncture to get the efficacy of acupuncture, the experiment was planned to confirm whether the form and Qi of subject has different result according to the stimulated duration and depth. On the basis of the report that acupuncture on derma, when using electroacupuncture at Zusanli(ST 36) which denotes small intestinal motility, is more efficient than full depth acupuncture, I got the following result, after I observed whether the stimulated duration and depth give different efficacy according to the sex and weights of rat in experiment. The increased effects of small intestinal motility by electroacupuncture on Zusanli(ST 36) appeared after stimulating full depth for thirty minutes without distinction of sex and weights. This significant change was observed only in the female experimental group when I distinguished the sex. The small interstinal motility in rats by electroacupuncture at zusanli(ST 36) decreased in the 10 minutes' stimulated group and 30 minutes' stimulated group by duration on the one hand, and derma-deep stimulated group and full depth stimulated group by the depth of stimulus on the other hand, as the weights increased. This result shows that the duration and depth of acupuncture depends on the differences of acupuncture points, sex of the experimental animals, ages, and, weights. And the further study on the experimental and clinical differences and sextual differences need to be continued on.
Journal of the Korea Society of Computer and Information
/
v.17
no.4
/
pp.51-58
/
2012
Recently, 3D technology based on depth image is widely used in various fields including 3D space recognition, image acquisition, interaction, and games. Depth camera is used in order to produce depth image, various types of effort are made to improve quality of the depth image. In this paper, we suggests using area-based Canny edge detector to improve depth image in applying 3D technology based on depth camera. The suggested method provides improved depth image with pre-processing and post-processing by fixing image quality deterioration, which may take place in acquiring depth image in a limited environment. For objective image quality evaluation, we have confirmed that the image is improved by 0.42dB at maximum, by applying and comparing improved depth image to virtual view reference software. In addition, with DSCQS(Double Stimulus Continuous Quality Scale) evaluation method, we are reassured of the effectiveness of improved depth image through objective evaluation of subjective quality.
Cerebral vasoreactivity is an index of autoregulation of cerebral perfusion, and can be measured using functional images such as Xe CT, SPECT and PET in reponse to hypercapneic stimulus. In order to measure cerebral $CO_2$ vasoreactivity in routine TCD study conveniently and reliably, we devised a method of rebreathing into closed volume of reservoir bag as a hypercapneic stimulus, and applied it to 44 healthy volunteers. As a hypercapneic stimulus, we applied fitting mask connected with closed reservoir bag for about 90 seconds, and mean blood flow velocity(MBFV) and pulsatility index(PI) were evaluated at proximal middle cerebral arteries(MCA) of 50-55 mm depth, before and after the hypercapneic stimulus. Age affected the MFV and PI value showed significant and the MFV was 56.45(SD=9.75)cm/sec, while PI was 0.406(SD=0.089). As age increases the flow velocity decreased significantly whereas PI value increased(P<0.05). The vasoreactvity significantly decreased with age(P<0.05). The decrease of cerebral blood flow quantity and cerebral blood flow velocity is not only because of increase of diameter of cerebrovascular resulting from aging, but the resistance increase of small blood vessel resulting from the increase of PI & RI value is regarded. We suppose that the rebreathing method is a reliable and convenient technique as a hypercapneic stimulus in determining cerebral $CO_2$ vasoreactivity. The rebreathing method could be non-invasive and useful methods in estimation of the cerebrovascular reactivity and could be applied to the basal and follow-up evaluation of the cerebrovascular reserve of the ischemic stroke patients.
Journal of the Korean Society of Clothing and Textiles
/
v.37
no.5
/
pp.645-654
/
2013
This study investigated the difference of reference price, preference and quality perception of high functional underwear according to innovation cues. High functional underwear was selected as a research stimulus due to its technological innovative characteristics. A total of 93 male university students participated as subjects and data were collected by simple random experimental design operationalized with three types of innovation stimulus cues. Two types of internal reference price perception-expected price and fair price, preference, and 9 items of product quality perception-8 functional properties and overall quality of stimulus were measured with a questionnaire. The result supported the difference of reference price and quality perception by product innovation cue. The higher cue level group perceived two types of reference price and the overall quality higher than the lower cue level group. The difference of the expected price and fair price, the influence of functional properties on overall quality, and relations of the variables were discussed in depth.
Understanding the process of spatial perception plays a significant role in the design process as well as in the use of actual spaces. The perception of spatial depth can vary according to the space composition and design even there is no change in the actual size of the space. The properties of 3-dimensional space are its width, height, and depth; however, compared to the perception of spatial width and height, little research and theories exist on spatial depth perception. The reasons may be there less interest lies in the effect of spatial depth perception than that of spaciousness or height of space. This study is an investigation of the process of spatial depth perception using an eye-tracking device with stimuli developed through Computer Graphics. A total of 44 interior design major students participated in the eye tracking experiment; and they looked at three images comprised of an identical room with only changes in the rear wall condition. The results show that a significant difference in the fixation duration per stimulus exists. In addition, a significant difference exists on the fixation duration per stimulus according to the participants' answer of the deepest space. The result of this study can help identify factors for spatial depth perception, validate the assumption on it, and provide knowledge on how to acquire desirable spatial depth by utilizing the research result.
For the development of feasible retinal prosthesis, one of the important elements is acquiring proper judging tool if electrical stimulus leads to patient's visual perception. If evoked potential to electrical stimulus is recorded in primary visual (V1) cortex, it means that the stimulus effectively evokes visual perception. Therefore, in this study, we established VEP recording system on V1 cortex using BioPAC modules as the judging tool. And the measuring system was evaluated by recording VEP of mice. After anesthesia, normal mice (C57BL/6J strain; n = 6) were secured to stereotaxic apparatus (Harvard Apparatus, USA). For the recording of VEP, the stainless steel needle electrode (impedance: $2-5k{\Omega}$) was positioned on the surface of the cortex through the burr hole at 2.5 mm lateral and 4.6 mm caudal to bregma. DA 100C and EEG 100C BioPAC modules were used for the trigger signal and VEP recording, respectively. When left eye was blocked by black cover and right eye was stimulated by flash light using HMsERG (RetVet Corp, USA), VEP response at left V1 cortex was detected, but there was no response at right V1 cortex. Amplitudes and latencies of P2, N3 peaks of VEP recording varied according to the depths of the electrodes on V1 cortex. From the surface upto $600{\mu}m$ depth, amplitudes of P2 and N3 increased, while deeper than $600{\mu}m$, those amplitudes decreased. The deeper the insertion depth of the electrode, the latency of N1 peaks tends to be delayed. However, there was no statistically significant difference among the latencies of P2 and N3 peaks (P > 0.05, ANOVA). Our VEP recording data such as the insertion depth and the latency and amplitudes of peaks might be used as guidelines for electrically-evoked potential (EEP) recording experiment in near future.
3D contents could cause unique 3D visual fatigue. Screen disparity, image blurring, and crosstalk are known to be the three major factors responsible for the fatigue. Among these, screen disparity and image blurring are content factors, that is, one can directly manipulate contents themselves to handle visual fatigue caused by these two factors. On the other hand, because crosstalk is closely tied to physical characteristics of 3D display, it is difficult or even impossible to reduce crosstalk-driven visual fatigue unless one replaces 3D display itself (for example, from active to passive display). However, the effects of crosstalk on 3D visual fatigue depends on visual stimulus features (that is, contents), and thus it is possible to manipulate stimulus features in order to handle visual fatigue caused by crosstalk. Hence, this research tested the effects of visual stimulus features on crosstalk (which then causes 3D visual fatigue). Using relative depth discrimination task, we tested the effects of stimulus-background contrast, background texture density, and screen disparity on the degree of perceived crosstalk. The results showed that crosstalk decreases with presence of background texture and with less degree of screen disparity.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.