• Title/Summary/Keyword: stimulator

Search Result 332, Processing Time 0.03 seconds

Fabrication and Evaluation of Tactile Stimulator Using Stacked PZT (적층형 액추에이터를 이용한 촉각자극기의 제작 및 평가 PZT)

  • 윤명종;권대규;김남균;유기호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.450-453
    • /
    • 2004
  • A tactile stimulator array using stacked PZT is fabricated and evaluated in this paper. The purpose of this research is the development of a tactile stimulator to represent the obstacle information for the visually disabled. As a first step of this research, we investigate the physiological characteristics of tactile stimuli and design a tactile stimulator based on the investigated results. Also we evaluated a fabricated tactile stimulator. The prototype of tactile stimulator which has 2$\times$2 tactor elements with 3mm spacing is fabricated using stacked PZT actuator. In order to evaluate the characteristics of this tactile stimulator, physiological experiments are carried out. In the experiment, the threshold of tactile stimulus intensity within a frequency range of 5-500Hz at various stimulus amplitudes are investigated. According to the obtained experimental result, the input signal of tactile stimulator for the effective transfer of obstacle information is determined. Also physiological experiments of multi-stimuli recognition such as shift and rotation are carried out

  • PDF

Fabrication and Evaluation of Tactile Stimulator Array Using Stacked PZT

  • Yoon, Myoung-Jong;Kwon, Tae-Kyu;Yu, Kee-Ho;Kim, Nam-Gyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.171-175
    • /
    • 2004
  • A tactile stimulator array using stacked PZT is fabricated and evaluated in this paper. The purpose of this research is the development of a tactile stimulator to represent the obstacle information for the visually disabled. As a first step of this research, we investigate the physiological characteristics of tactile stimuli and design a tactile stimulator based on the investigated results. Also we evaluated a fabricated tactile stimulator. The prototype of tactile stimulator which has 2x2 tactor elements with 3mm spacing is fabricated using stacked PZT actuator. In order to evaluate the characteristics of this tactile stimulator, physiological experiments are carried out. In the experiment, the threshold of tactile stimulus intensity within a frequency range of 5-500Hz and at various stimulus amplitudes are investigated. According to the obtained experimental result, the input signal of tactile stimulator for the transfer of obstacle information is determined. Also physiological experiments of multi-stimuli recognition such as shift and rotation are carried out.

  • PDF

The Magnetic Nerve Stimulator Using a Switching Mode Power Supply (스위칭전원을 이용한 자기신경자극기)

  • Lee, Su-Yeol;Lee, Seong-Geun;Lee, Jeong-Han
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.265-270
    • /
    • 1995
  • An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for chArging high voltage cApacitors, the weight and size of the magnetic net've stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec Experimental results of human nerve stimulations using the developed stimulator are presented.

  • PDF

A Plastic Cortex Stimulator for Stroke Recovery Using ZigBee technology (ZigBee 무선통신 기술을 이용한 뇌졸중 환자 치료용 뇌자극기 개발)

  • Kim, G.H.;Yang, Y.S.;Lee, S.M.;Kim, N.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.373-375
    • /
    • 2005
  • The purpose of this paper is to develop the Plastic Cortex Stimulator(PCS) for stroke patients using ZigBee technology. The PCS consists of an implantable neuro-stimulator and a user controller, The neuro-stimulator has the stimulus circuit which is the H-bridge circuit to generate a bipolar pulse. The bipolar pulse is known to be effective for stroke recovery. The user controller sends several wave-shape parameters (amplitude, pulse width, cycle, etc.) to the neuro-stimulator for variable stimulation using ZigBee technology. The CC2420 and atmega128L was used to implement ZigBee protocol stack. The wireless control of PCS based on ZigBee can help the tele-rehabilitation of the stroke patients. The most effective pulse shape parameters are being investigated through animal experiments. The bio-compatibility and user-friendly interface are supposed to be handled in further study.

  • PDF

Development and Estimation of a Wireless Controlled Implantable Electric-stimulator for the Blood Pressure Regulation (혈압조절을 위한 모선 제어되는 체내 이식형 전기 자극기의 개발 및 체외 성능 평가)

  • Kim, Yoo-Seok;Park, Seong-Min;Shim, Eun-Bo;Choi, Seong-Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.395-400
    • /
    • 2010
  • Hypertension is the chronic disease that the 16% of total population are suffering, and it needs to be studied to find alternative treatment because of the tolerance and side effect of medications that may bother some patients. in this paper, we verified practicality of implantable electrical stimulator that can readily change stimulus magnitude and frequency. And this device is possible to stimulate baroreflex or parasympathetic nerve. Therefore we performed in vitro tests and animal experiment for device's operating conditions. This device consist of implantable electrical stimulator and extracorporeal control/monitoring system. Stimulator was designed to make 1Hz~100Hz pulses and it can change continuous or periodic pulse train type. And this device can control stimulator's function and monitor stimulator's status and patients' blood pressure at exterior of body using ZigBee module as wireless telecommunication. We verified that stimulator have error rate under 5% at 50mm depth of organs and, stimulator makes high-efficiency energy with closer position of two electrodes. Also we can confirm the performance of device that decreasing blood pressure and heart rate of a rat by electrical stimulation.

Stimulus Artifact Suppression on the type of Nerve Stimulator (신경자극기 형태에 따른 자극 Artifact 제거 방법에 대한 연구)

  • 유세근;민병관
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.251-256
    • /
    • 1993
  • The conduction velocity of the nerve is of importance to the diagnosis of various negromuscular disorders. A major technical problem encountered in nerve stimulation technique is the control of stimulus artifact and the convenience of nerve stimulator. The remained artifacts must be removed by processing the contaminated signal. This paper discusses about the artifact cancellation algorithms in constant voltage type nerve stimulator(CVS) and constant current type nerve stimulator(CCS).

  • PDF

Towed Underwater LDV Measurement of the Interaction of a Wire-Type Stimulator and the Boundary Layer on a Flat Plate (예인수조 LDV를 이용한 평판 경계층과 와이어 타입 난류촉진장치의 상호작용에 관한 연구)

  • Park, Jongyeol;Seo, Jeonghwa;Rhee, Shin Hyung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.4
    • /
    • pp.243-252
    • /
    • 2021
  • The present study aims to investigate the interaction of a wire-type turbulence stimulator and the laminar boundary layer on a flat plate by flow field measurement. For the towing tank tests, a one-dimensional Laser Doppler Velocimetry (LDV) attached on a two-axis traverse was used to measure the streamwise velocity component of the boundary layer flow in zero pressure gradient, disturbed by a turbulence stimulator. The wire diameter was 0.5 and 1.0 mm according to the recommended procedures and guidelines suggested by the International Towing Tank Conference. Turbulence development by the stimulator was identified by the skin friction coefficient, mean and Root Mean Square (RMS) of the streamwise velocity. The laminar boundary layer with the absence of the wire-type stimulator was similar to the Blasius solution and previous experimental results. By the stimulator, the mean and RMS of the streamwise velocity were increased near the wall, showing typical features of the fully developed turbulent boundary layer. The critical Reynolds number was reduced from 2.7×105 to 1.0×105 by the disturbances caused by the wire. As the wire diameter and the roughness Reynolds number (Rek) increased, the disturbances by the stimulator increased RMS of the streamwise velocity than turbulent boundary layer.

A Display-based Visual Stimulator for Psychophysical and Electrophysiological Color Sensitivity Measurements

  • Hwang, Jisoo;Park, Seung-Nam;Park, Cheol-Min;Lee, Geun Woo;Kim, Kiseong
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.145-150
    • /
    • 2012
  • We present a display-based visual stimulator for psychophysical and electrophysiological visual sensitivity measurements. The stimulator offers various psychophysical visual stimuli and transfers the signals from external devices along with the stimulation signals to an electrophysiological recorder. As an experimental demonstration, we perform a visual sensitivity experiment in the mesopic vision range by using the display-based stimulator. The intensity of the steady-state visual evoked potential is observed to correlate with the luminance of the flickering visual stimulation. For the psychophysically determined detection thresholds, we determine the mesopic luminance, showing agreement with the perceived brightness within the uncertainty of the luminance measurement.

Immediate Effect of Foot Drop Stimulator in Outpatients with Chronic Stroke: A Mixed Method Study

  • Park, Jaeyoung;Lee, Dooho;Oh, Donghwan
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.1
    • /
    • pp.1992-1998
    • /
    • 2020
  • Background: The foot drop stimulator is designed to improve the walking ability of foot drop in patients after stroke, however, studies on clinical effects are still lacking. Objective: To investigate the effect of a foot drop stimulator on the walking and balancing abilities of foot drop patients after a stroke. Design: One-Group (Pretest-Posttest) Design. Methods: All subjects walked in all three conditions: foot drop stimulator (FDS) ankle foot orthosis (AFO) and barefoot. Primary outcome measures were assessed for walking and balance using a 10-m walking test (10MWT) and a timed up and go test (TUG). Secondary outcome measures consisted of a brief user interview, and the patients recorded the advantages and disadvantages of each condition. Results: FDS, AFO, and barefoot conditions showed a statistically significant difference in 10MWT and TUG (P<.001) as a result of comparing three conditions. FDS and AFO were significantly different from the barefoot condition as post-hoc results; however, there was no significant difference between the two conditions (P>.05). Conclusion: In this study, the foot drop stimulator contributed to improving the balance ability, and the walking ability was similar to the effect of the ankle-foot orthosis.

Ultrasonography-Combined with Nerve Stimulator Technique for Injection of the Genitofemoral Nerve in a Patient with Chronic Postoperative Inguinal Pain (수술 후 서혜부 만성 통증에서 신경 자극기를 이용한 초음파 유도하 음부대퇴신경 차단술)

  • Oh, Young-Bin;Shin, Hyun Baek;Ko, Myoung-Hwan;Seo, Jeong-Hwan;Kim, Gi-Wook
    • Clinical Pain
    • /
    • v.18 no.1
    • /
    • pp.36-39
    • /
    • 2019
  • Chronic postoperative inguinal pain (CPIP) is a major complication after inguinal herniorrhaphy. We report the treatment of CPIP using ultrasonography-combined with nerve stimulator for injection of the genitofemoral nerve (GFN). A 59-year-old man underwent laparoscopic herniorrhaphy and presented with numbness from the inguinal region to the scrotum after operation. In the pain clinic, ultrasonography-guided GFN block and pharmacological treatments had little effect. Six month after operation, patient was referred to the Department of Physical Medicine and Rehabilitation, and ultrasonography-combined with nerve stimulator for GFN injection underwent to enhance the accuracy of neural approach. The induction of scrotal contraction and paresthesia on the GFN distribution was monitored by nerve stimulator and local anesthetic was injected. After the block, pain relief lasted for 6 months without analgesic use. Ultrasonography-combined with nerve stimulator is an effective approach to treat CPIP as it enhances precise localization and injection of small peripheral nerve like GFN.