• Title/Summary/Keyword: sterilization dose

Search Result 61, Processing Time 0.021 seconds

Microbiological and Physicochemical Properties of Dried Fishery Treated with Ethylene Oxide(E. O) and Gamma Irradiation Products (Shucked Shellfish and Shucked Mussel Powder) (방사선 조사 및 Ethylene Oxide 처리된 건조 수산물 (조개살, 홍합살)의 미생물 및 화학적 특성)

  • 조한옥;변명우;권중호;양재승;이재원
    • Journal of Food Hygiene and Safety
    • /
    • v.1 no.1
    • /
    • pp.39-46
    • /
    • 1986
  • Comparison of ethylene oxide(E.O) fumigation and gamma irradiation on the sterilization, microbiological, physicochemcial and sensory quality of dried fishery products (shucked shellfish and mussel powder) were investigated. The viable cell count of mesophilic total bacterial was reduced by over 2 to 3 log cycles with irradiation of 3 to 5 kGy, and those samples were completely sterilized by irradiation dose of 7 to 10 kGy. In view of reduction of microorganisms, D10 value of each samples were ranged from 1. 36-1. 46 kGy. fungi, mesophilic spores, acid tolerant bacteria and coliforms were sterilized at 5 to 7 kGy irradiation but E.O. fumigation proved insulfficient to eliminate the mesophilic total bacteria and fungi. In the physicochemical and sensory quality of samples, such as the amino acid, TBA value, TMA-N, color difference and overall acceptability irradiated sample with optimum dose was similar to those of the nonirradiated sample, while E.O. fumigated sample was remarkably deteriorated in the physicochemical and sensory quality of samples.

  • PDF

Sterilization of Freeze Dried Manila Clam (Ruditapes philippinarum) Porridge for Immuno-Compromised Patients

  • Song, Beom-Seok;Park, Jae-Nam
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.205-210
    • /
    • 2016
  • This study was conducted to evaluate the combined effect of gamma irradiation and different conditions (vacuum packaging, antioxidant and freezing) on the microbiological and sensory characteristics of freeze dried Manila clam porridge (MCP) for immuno-compromised patient food. MCP can be sterilized at 1 kGy to 10 kGy. The initial counts of total aerobic bacteria and yeast molds in the non-irradiated MCP were $2.4{\pm}0.5$ and $1.2{\pm}0.3{\log}\;CFU\;g^{-1}$, respectively, but gamma irradiation significantly decreased the total aerobic bacteria to below the detection limit ($1{\log}\;CFU\;g^{-1}$) (5 kGy). Moreover, gamma irradiation effectively eliminated yeasts/molds at dose below than 1 kGy. However, gamma irradiation accelerated the increase of lipid oxidation and therefore, decreased the sensory characteristics of MCP as irradiation dose increased. To improve the sensory qualities of gamma irradiated MCP, combination treatment (vacuum packaging, 0.1% vitamin C) were applied. There was no significant difference in the overall acceptance scores between the combined-treatment sample (5.6 points) and the non-irradiated samples (6.0). The results indicate that combination treatment (vacuum packaging, 0.1% vitamin C) may help to maintain the quality of MCP. Therefore, it considered that irradiation of MCP with combined treatment and this is an effective method for the consumption as a special purpose food such as for space travel or immuno-compromised patients.

FTIR study of gamma and electron irradiated high-density polyethylene for high dose measurements

  • Al-Ghamdi, Hanan;Farah, Khaled;Almuqrin, Aljawharah;Hosni, Faouzi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.255-261
    • /
    • 2022
  • A reliable and well-characterized dosimetry system which is traceable to the international measurement system, is the key element to quality assurance in radiation processing with cobalt-60 gamma rays, X-rays, and electron beam. This is specifically the case for health-regulated processes, such as the radiation sterilization of single use medical devices and food irradiation for preservation and disinfestation. Polyethylene is considered to possess a lot of interesting dosimetric characteristics. In this work, a detailed study has been performed to determine the dosimetric characteristics of a commercialized high-density polyethylene (HDPE) film using Fourier transformed infrared spectrometry (FTIR). Correlations have been established between the absorbed dose and radiation induced infrared absorption in polyethylene having a maximum at 965 cm-1 (transvinylene band) and 1716 cm-1 (ketone-carbonyl band). We have found that polyethylene dose-response is linear with dose for both bands up to1000 kGy. For transvinylene band, the dose-response is more sensitive if irradiations are made in helium. While, for ketone-carbonyl band, the dose-response is more sensitive when irradiations are carried out in air. The dose-rate effect has been found to be negligible when polyethylene samples are irradiated with electron beam high dose rates. The irradiated polyethylene is relatively stable for several weeks after irradiation.

Effect of Irradiation on the Sterilization of Black Pepper Powder (방사선(放射線) 조사(照射)가 후추가루의 살균(殺菌)에 미치는 영향(影響))

  • Byun, Myung-Woo;Kwon, Joong-Ho;Lee, Me-Kyung;Cho, Han-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.319-321
    • /
    • 1984
  • Black pepper powder was irradiated at dose of 3,6 and 9 kGy, stored at ambient temperature in order to investigate the effect of irradiation on their microbial sterilization and physicochemical properties. Total and coliform bacteria were sterilized by irradiation up to 9 kGy and 3 kGy, respectively, and they were not grown until the end of storage period. $D_{10}$ value of total bacteria were in the range of 1.39-1.49 kGy. Proximate composition was not significantly changed according to the increase of irradiation dose except slight increase of the reducing sugar. The yield of volatile oil was slightly decreased by the increase of irradiation dose.

  • PDF

Sterilization and Storage of Spices by Irradiation -I. Sterilization of Powdered Hot Pepper Paste- (방사선(放射線)에 의(依)한 향신료(香辛料)의 살균(殺菌) 및 저장(貯藏)에 관(關)한 연구(硏究) -제(第) 1 보(報) : 고추장분말(粉末)의 살균(殺菌)-)

  • Byun, Myung-Woo;Kwon, Joong-Ho;Cho, Han-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.359-363
    • /
    • 1983
  • Effects of irradiation on the physicochmical properties and its quality of powdered hot pepper paste which was used as a minor matrial of meat products, were investigated during the three months storage. Proximate components of powdered hot pepper paste were not remarkably changed according to the irradiation dose except the slight increase of total and reducing sugars. Capsanthin was insignificantly decreased by the increase of irradiation dose. Color difference according to the irradiation dose could not be distinguished by naked eye but was slightly changed by mechanical measurement. Total bacteria and E.coli were sterilized by the irradiation of 10kGy and 5kGy, respectively and no microorganisms were grown up after three months storage at $37^{\circ}C$. Sterilization of powered hot pepper paste by irradiation was expected to be superior to the traditional methods in the wholsomeness and sterilizing efficacy.

  • PDF

The Research Relating to QA of the Absorbed Dose in the 10 MeV E-beam Facility in Accordance with the International Standards (국제표준에 따른 10 MeV급 전자빔 조사시설의 흡수선량 품질보증에 관한 연구)

  • Ha, Tae-Sung;Ahn, Cheol;Jung, Pyeong-Hwan;Cho, Jeong-Hee;Lee, Jong-Seok;Lee, Hye-Nam;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.387-394
    • /
    • 2010
  • In the field of healthcare, the conventional sterilization treatments have been replaced by irradiation methods which are in accordance with internationally well established quality standards. The quality control in radiation sterilization assures that the absorbed dose of the irradiated material is in agreement with its requirements and standards. The electron beam irradiation requires technical assessments of more process parameters than gamma irradiation does. Korea has witnessed wide uses of electron accelerators since early 2000 but there hasn't been research experiences relating to quality system in accordance with international standards. The new large scale e-beam irradiation system with the specification of 10 MeV, 8 kW was installed and operated in 2008 by Seoul Radiology Services Co. It consists of the electron accelerator, product handling system, safety, documentation and control subsystems into an integrated system to meet the requirement of the Good Manufacturing Practice such as process quality assurance and management of product tracking records. To implement the international standard such as EN ISO11137, it is necessary to understand the purposes aimed in the standard and carry out the tests following the procedures required. This study presented the specification of the e-beam facility and showed what its design requirements and features are. The test results on a variety of process parameters were presented and validated it they are within the required limits.

Hygienic Quality and Genotoxicological Safety of Gamma Irradiated Pork (감마선조사에 의한 돈육의 위생화 및 유전독성학적 안전성 평가)

  • 강일준;윤정한;강영희;이효구;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.5
    • /
    • pp.1092-1098
    • /
    • 1999
  • Gamma irradiation was applied to pork for improving its hygienic quality and evaluating its possible genotoxicity. The effective dose of irradiation was 3 kGy in pork for the sterilization of all contaminated microorganisms tested. After 8 weeks of storage at 5oC, no growth of microorganisms except for psychrophile and total aerobic bacteria was observed in the more than 3 kGy irradiated pork. The genotoxicity of high dose irradiated pork(30 kGy) was evaluated by Salmonella typhimurium reversion assay, chromosomal aberration test and in vivo micronucleus assay. The results were negative in the bacterial reversion assay with S. typhimurium TA98, TA100, TA1535, TA1537. In chromosomal aberration tests with CHL cells and in vivo mouse micronucleus assay, no significant difference in the incidences of chromosomal aberration and micronuclei was seen between nonirradiated and 30 kGy irradiated porks. These results indicate that 30 kGy irradiated pork did not show any genotoxic effects under these experimental conditions.

  • PDF

Exposure Assessment of Microbiological Risk Factors from Edible Ices (빙과류의 미생물학적 위해요소에 대한 노출평가)

  • Kim, Tae-Woong;Choi, Jae-Ho;Bahk, Gyung-Jin;Oh, Deog-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.3
    • /
    • pp.226-231
    • /
    • 2009
  • The aim of this study was to determine exposure assessment of pathogenic bacteria in edible ices by using the monitoring data from the previous study. According to the results of exposure assessment of edible ices contaminated with S. aureus, the contamination level of S. aureus in raw materials was higher than other foodborne pathogens, and the contamination level of S. aureus in mixed samples increased much before sterilization. The most significant reduction in contamination level was observed in mixed samples after sterilization, thus, the contamination levels in frozen final products was less than that of raw materials. Overall, the possibility for the infection of foodborne bacteria from the intake of edible ices per person per day was ranged from minimum $5.89{\times}10^{-7}$ to maximum $5.01{\tims}10^{-5}$. For more realistic estimates, consumption of edible ices and dose-response model must be studied further.

Sanitation and Quality Improvement of Salted and Fermented Anchovy Sauce by Gamma Irradiation (멸치액젓의 위생적 품질향상을 위한 감마선 조사기술 이용)

  • 김재현;안현주;김정옥;류기형;육홍선;이영남;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.6
    • /
    • pp.1035-1041
    • /
    • 2000
  • Gamma irradiation was used to improve sanitation and quality of salted and fermented anchovy sauce. For commercial production, comparison with currently using sterilization methods, such as micro-filtration and heat treatment were also conducted. Control was prepared without irradiation and sterilization process. Microbiological, physiochemical, and sensory qualities were analyzed to observe the Quality changes during the storage. Irradiation at 5 kGy or above and micro-filtration process completely eliminated microorganisms detected in this study As irradiation dose increased, the color appeared brighter and irradiation at 5 kGy or above showed similar color L-value to that of sample treated with microfiltration. The color L, a, b-value of heat-treated sample always showed lower. The pH, salinity, and viscosity were sustained during storage. From the results of sensory evaluation, the samples treated with gamma irradiation and microfiltration obtained better scores than control or heat-sterilized. Gamma irradiation to salted and fermented anchovy sauce presented the best quality products among different sterilizing methods, especially at 5 kGy dose. Therefore, gamma irradiation can be successfully applied to commercial large scale production as a new sanitation technology with improved quality.

  • PDF

Microbiological and Sensory Characteristics of Gamma-irradiated Frozen Bibimbap (감마선 조사 냉동비빔밥의 미생물 및 관능적 품질특성)

  • Park, Jae-Nam;Song, Beom-Seok;Yoon, Young-Min;Choi, Soo-Jeong;Park, Jong-Heum;Kim, Jae-Kyung;Byun, Eui-Baek;Lee, Ju-Woon;Han, In-Jun;Sohn, Hee-Sook;Kim, Jae-Hun
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.93-99
    • /
    • 2013
  • This study was conducted to evaluate the effect of gamma irradiation on the microbiological and sensory characteristics of frozen Bibimbap. Frozen Bibimbap vegetables were contaminated by microbial levels of $2.70{\sim}6.67log\;CFU\;g^{-1}$ in total aerobic bacteria. Frozen Bibimbap was contaminated by microbial levels of $4.8log\;CFU\;g^{-1}$ in total aerobic bacteria, but microorganisms in gamma-irradiated samples at above 25 kGy were not found at detection limit less then $1log\;CFUg^{-1}$. Sensory characteristics of the gamma-irradiated Bibimbap were decreased depending upon the irradiation dose, and sensory scores of the samples irradiated with doses higher than 10 kGy were significantly decreased. Therefore, the application of combination of the various food processing technology should be considered for the sterilization of Bibimbap, without any deterioration of quality occurred by high dose irradiation.