• 제목/요약/키워드: stereotactic technique

검색결과 65건 처리시간 0.027초

Quantitative Evaluation of Setup Error for Whole Body Stereotactic Radiosurgery by Image Registration Technique

  • Kim, Young-Seok;Yi, Byong-Yong;Kim, Jong-Hoon;Ahn, Seung-Do;Lee, Sang-wook;Im, Ki-Chun;Park, Eun-Kyung
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.103-105
    • /
    • 2002
  • Whole body stereotactic radiosurgery (WBSRS) technique is believed to be useful for the metastatic lesions as well as relatively small primary tumors in the trunk. Unlike stereotactic radiosurgery to intracranial lesion, inherent limitation on immobilization of whole body makes it difficult to achieve the reliable setup reproducibility. For this reason, it is essential to develop an objective and quantitative method of evaluating setup error for WBSRS. An evaluation technique using image registration has been developed for this purpose. Point pair image registrations with WBSRS frame coordinates were performed between two sets of CT images acquired before each treatment. Positional displacements could be determined by means of volumetric planning target volume (PTV) comparison between the reference and the registered image sets. Twenty eight sets of CT images from 19 WBSRS patients treated in Asan Medical Center have been analyzed by this method for determination of setup random error of each treatment. It is objective and clinically useful to analyze setup error quantitatively by image registration technique with WBSRS frame coordinates.

  • PDF

A case report of a patient with squamous cell carcinoma of the face irradiated using a stereotactic technique

  • Pontoriero, Antonio;Iati, Giuseppe;Pergolizzi, Stefano
    • Radiation Oncology Journal
    • /
    • 제33권3호
    • /
    • pp.261-264
    • /
    • 2015
  • External beam radiotherapy can be used to treat cutaneous squamous cell carcinomas (SCC). Acute skin toxicity is the most common adverse event. In this case study we report on an elderly patient with nasal root cutaneous SCC treated with stereotactic technique using a dedicated linear accelerator (CyberKnife system). Grade 3 skin toxicity was observed but it was resolved after 6 weeks. The use of stereotactic radiotherapy permitted a clinical remission of SCC with good cosmetic results.

양성자 화학적 이동영상기법(1H-CSI)을 이용한 정위적 뇌생검 (Proton Magnetic Resonance Chemical Shift Imaging(1H-CSI)-directed Stereotactic Brain Biopsy)

  • 장경술;손병철;김문찬;최병길;김의녕;김범수;최보영;백현만;홍용길;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권12호
    • /
    • pp.1606-1611
    • /
    • 2000
  • Objective : To obtain more reliable sample in stereotactic biopsy, authors adopted proton chemical shift imaging ($^1H$-CSI)-directed biopsy. Until now, proton single voxel spectroscopy($^1H$-SVS) technique has been reported as a technique using metabolic information in stereotactic biopsy. The authors performed $^1H$-CSI with a stereotactic headframe in place and evaluated the pathologic results obtained from local metabolic information through $^1H$-CSI. Methods : $^1H$ CSI-directed stereotactic biopsy was performed in four patients. $^1H$-CSI and conventional Gd-enhancement stereotactic MRI was done simultaneously after application of the stereotatic frame. After reconstruction of metabolic maps of NAA/Cr, Cho/Cr, and Lactate/Cr ratios, the focal areas of increased Cho/Cr ratios and decreased NAA/Cr ratios were selected for target sites in the MR images Results : There was no difficulty in performing $^1H$-CSI with the stereotactic headframe in place. In pathologic examinations, the samples taken in area of increased Cho/Cr ratios and decreased NAA/Cr ratios showed the features of increased cellularity, mitoses and cellular atypism, thus facilitated the diagnosis. The pathologic samples taken from the area of increased Lactate/Cr ratios showed prominent feature of necrosis. Conclusion : $^1H$-CSI was feasible with stereotactic head frame in place. The final pathologic results obtained in our samples were concordant with the local metabolic informations from $^1H$-CSI. Authors believe that $^1H$ CSI-directed stereotactic biopsy may provide us advantages in obtaining more reliable tissue specimen in stereotactic biopsy.

  • PDF

노발리스 ExacTrac system을 이용한 척추 정위 방사선수술 방법 평가 (Assessment of the Optic-guided Patient Positioning for Spinal Stereotactic Radiosurgery Using Novalis ExacTrac System)

  • 이동준;손문준;최광영;이기택;최찬영;황금철;황충진
    • 한국의학물리학회지:의학물리
    • /
    • 제13권4호
    • /
    • pp.218-223
    • /
    • 2002
  • 두개외 병소 즉, 척추 등에 발생한 종양 혹은 혈관기형 등의 병소에 대해 침습적 수술이 불가한 경우 정위적 방사선 수술이 임상에서 시도되고 있다. 본 연구는 실험적으로 팬텀에 대해 척추 정위 방사선수술을 시행하고 결과 분석을 통하여 두개외 수술 목표점에 대한 방사선수술 위치 정확도를 평가하고자 한다. 이 실험을 위하여 팬텀을 특별히 고안하였으며 수술실에서 방사선 수술 목표점의 위치는 광학적 추적 장치를 이용하여 결정하였고 3 mm 미세다엽시준기(mMLC; mcro Multi-Leaf Collimator)를 사용하여 시술하였다. 팬텀의 목표점에 대한 방사선수술 오차는 $\pm$1 mm 이내였으며 분할방사선 수술 경우도 $\pm$1 mm 이내였다. 결과적으로 광학적 위치추적 장치를 이용한 두개외 목표점의 방사선 수술은 매우 정확하고 유용한 방법으로 판단된다.

  • PDF

Stereotactic radiotherapy for early stage non-small cell lung cancer

  • Ricardi, Umberto;Badellino, Serena;Filippi, Andrea Riccardo
    • Radiation Oncology Journal
    • /
    • 제33권2호
    • /
    • pp.57-65
    • /
    • 2015
  • Stereotactic body radiotherapy (SBRT) represents a consolidated treatment option for patients with medically inoperable early stage non-small cell lung cancer (NSCLC). The clinical evidence accumulated in the past decade supports its use as an alternative to surgery with comparable survival outcomes. Due to its limited toxicity, SBRT is also applicable to elderly patients with very poor baseline pulmonary function or other severe comorbidities. Recent comparative studies in operable patients raised the issue of the possible use of SBRT also for this subgroup, with quite promising results that still should be fully confirmed by prospective trials with long-term follow-up. Aim of this review is to summarize and discuss the major studies conducted over the years on SBRT and to provide data on the efficacy and toxicity of this radiotherapy technique for stage I NSCLC. Technical aspects and quality of life related issues are also discussed, with the goal to provide information on the current role and limitations of SBRT in clinical practice.

Evaluation of an Experimentally Designed Stereotactic Guidance System for Determining Needle Entry Point during Uniplanar Fluoroscopy-guided Intervention

  • Lee, Jae-Heon;Jeon, Gye-Rok;Ro, Jung-Hoon;Byoen, Gyeong-Jo;Kim, Tae-Kyun;Kim, Kyung-Hoon
    • The Korean Journal of Pain
    • /
    • 제25권2호
    • /
    • pp.81-88
    • /
    • 2012
  • Background: In discography performed during percutaneous endoscopic lumbar discectomy (PELD) via the posterolateral approach, it is difficult to create a fluoroscopic tunnel view because a long needle is required for discography and the guide-wire used for consecutive PELD interrupts rotation of fluoroscope. A stereotactic system was designed to facilitate the determination of the needle entry point, and the feasibility of this system was evaluated during interventional spine procedures. Methods: A newly designed stereotactic guidance system underwent a field test application for PELD. Sixty patients who underwent single-level PELD at L4-L5 were randomly divided into conventional or stereotactic groups. PELD was performed via the posterolateral approach using the entry point on the skin determined by premeasured distance from the midline and angles according to preoperative magnetic resonance imaging (MRI) findings. Needle entry accuracy provided by the two groups was determined by comparing the distance and angle measured by postoperative computed tomography with those measured by preoperative MRI. The duration and radiation exposure for determining the entry point were measured in the groups. Results: The new stereotactic guidance system and the conventional method provided similarly accurate entry points for discography and consecutive PELD. However, the new stereotactic guidance system lowered the duration and radiation exposure for determining the entry point. Conclusions: The new stereotactic guidance system under fluoroscopy provided a reliable needle entry point for discography and consecutive PELD. Furthermore, it reduced the duration and radiation exposure associated with determining needle entry.

다용도 팬톰에서 정위방사선수술기법의 선량 정확도 확인 (Confirmation of the Dose Distribution by Stereotactic Radiosurgery Technique with a Multi-purpose Phantom)

  • 유형준;김일한;하성환;박찬일;허순녕;강위생
    • Radiation Oncology Journal
    • /
    • 제20권2호
    • /
    • pp.179-185
    • /
    • 2002
  • 목적 : 본 교실에서 개발한 정위방사선수술 시스템의 정도관리를 위하여 다용도 팬톰을 제작하고 정위방사선수술 기법의 선량의 정확도를 확인하려 하였다. 대상 및 방법 : CL2100C 선형가속기에서 발생하는 6 MV 엑스선을 사용하여 정위적 방사선수술을 시행하였고 Farmer형 이온함, 0.125 cc 이온함, 다이오드 검출기 등을 정위 기준기구가 부착된 팬톰내에 설치한 후 선량을 측정하였다. 고정 빔, $20^{\circ}\~100^{\circ}$의 각도를 갖는 단일회전빔, 복합회전빔 등의 방사선조사 조건에서 측정기와 팬톰의 상대적 위치를 변화시키면서 측정하였다. 내경이 10, 20, 30, 40 mm인 원형의 3차 콜리메이터를 사용하였다. 결과 : 고정 빔, 단일 회전빔, 5개의 회전 빔으로 구성된 복합회전빔 등에서의 선량오차는 Farmer형 이온함으로 측정한 경우는 $0.5\%$ 이하, 0.125 cc 이온함의 경우에는 $0.5\%$, 다이오드 검출기인 경우에는 $2\%$ 이내였다. 결론 : 본 교실 개발 정위방사선수술 기법에 의한 방사선 조사선량의 정확도를 확인하였으며 이 자료는 향후 정위방사선수술 및 다분할 방사선치료의 정도관리에 유용한 기초자료로 활용될 것이다.

방사선수술을 위한 3차원 정위 시스템 및 방사선량 측정 시스템 개발 (Development of 3-D Stereotactic Localization System and Radiation Measurement for Stereotactic Radiosurgery)

  • 서태석;서덕영;박승훈;장홍석;최보영;윤세철;신경섭;박용휘;김일환;강위생;하성환;박찬일
    • Journal of Radiation Protection and Research
    • /
    • 제20권1호
    • /
    • pp.25-36
    • /
    • 1995
  • The purpose of this research is to develop stereotactic localization and radiation measurement system for the efficient and precise radiosurgery. The algorithm to obtain a 3-D stereotactic coordinates of the target has been developed using a Fisher CT or angio localization. The procedure of stereotactic localization was programmed with PC computer, and consists of three steps: (1) transferring patient images into PC; (2) marking the position of target and reference points of the localizer from the patient image; (3) computing the stereotactic 3-D coordinates of target associated with position information of localizer. Coordinate transformation was quickly done on a real time base. The difference of coordinates computed from between Angio and CT localization method was within 2 mm, which could be generally accepted for the reliability of the localization system developed. We measured dose distribution in small fields of NEC 6 MVX linear accelerator using various detector; ion chamber, film, diode. Specific quantities measured include output factor, percent depth dose (PDD), tissue maximum ratio (TMR), off-axis ratio (OAR). There was small variation of measured data according to the different kinds of detectors used. The overall trends of measured beam data were similar enough to rely on our measurement. The measurement was performed with the use of hand-made spherical water phantom and film for standard arc set-up. We obtained the dose distribution as we expected. In conclusion, PC-based 3-D stereotactic localization system was developed to determine the stereotactic coordinate of the target. A convenient technique for the small field measurement was demonstrated. Those methods will be much helpful for the stereotactic radiosurgery.

  • PDF

뇌실로 파열되어 있는 뇌농양에 대한 뇌정위적 내시경하 제거술 - 증례보고 - (Stereotactic Endoscopic Treatment of Brain Abscess Ruptured into Ventricle - Case Report -)

  • 손병철;김문찬;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권6호
    • /
    • pp.826-831
    • /
    • 2000
  • The major indication of endoscope in neurosurgical field is intraventricular procedures. Recently, it can be used selectively in the intraaxial mass lesion associated cavity. For example, cystic mass, with liquefied necrosis, and blood clot can be approached with this technique. The authors present its usage in brain abscess ruptured into lateral ventricle. The neuroendoscope was introduced into abscess cavity through stereotactic guidance, the pus was then removed through continuous irrigation and suction under direct video visualization. The intraventricular pus was also cleaned through gentle, direct endoscopic irrigation and suction. The postoperative clinical course was uneventful. Brief overview is given for this intraaxial neuroendoscopic procedure.

  • PDF

Linear Accelerator를 이용한 Stereotactic Radiosurgery 방법 (A Method of Stereotactic Radiosurgery Using A Linear Accelerator)

  • 나수경;박재일
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.146-153
    • /
    • 1994
  • A modified irradiation technique utilizing a linear accelerator for radiation surgery within the brain was performed in 41 cases of patients with anteriovenous malformation(AVM), astrocytoma, meningioma. etc. The treatment planning and dosimetry of small field for stereotactic radiosurgery with 10 MV X-ray isocentically mounted linear accelerator will be presented dose with field size, the central axis persent depth dose and the combined moving beam dose distribution. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor region was perfomed with dose planning computer system(Therac 2300) and was verified with film dosimetry. The more the number of strip and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. In this study, the using machine and method was as fellowing. 1) Apparatus : NELAC-1018 10MV X-ray 2) Strip No. : Select the 5-7 strips 3) Cone and field size are from $1{\times}1cm^2$ to $3.5{\times}3.5cm^2$, and special circular cone designed for the purpose of minimized the risk to normal tissue and those size are $0.7{\~}3.6cm{\phi}$.

  • PDF