• Title/Summary/Keyword: stereo analysis

Search Result 305, Processing Time 0.022 seconds

The study of seed morphological trait and testa characteristic for Korean Vicia species

  • Han, Se-Hui;;Kim, Seong-Hun;Hyeon, Do-Yun;Lee, Gyeong-Jun;Lee, Jeong-Ro;Jo, Gyu-Taek
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.04a
    • /
    • pp.64-64
    • /
    • 2019
  • In order to evaluate the taxonomical relevance of seeds morphological characteristics, a macroand micro-morphological study was conducted on seeds of Korean Vicia (Fabacea). We collected 19 taxa of genus Vicia distributed in Korea and introduced one taxa from USDA. The morphological characteristic and testa texture of seeds were investigated using a Stereo-microscope (SM) and Scanning Electron Microscope (SEM). Most of Vicia seeds were found spherical or oblong and some seeds were oval and subglose. The largest seed was V. chosenensis ($4.3{\times}3.6{\times}2.6mm$), and the smallest was V. teterasperma ($1.7{\times}1.7{\times}1.5mm$). V. chosenensis and V. hirsuta were separated from other Vicia species by having a shiny in seed finish. In hilum shape, 14 species have linear and V. sepium was distinguished by having a circumlinear. In testa texture, they developed papilae, only V. hirsuta has lophate in level type. Deposition of the sheet-like debris between the papilae was observed in V. chosenensis, V. cracca, and V. unijuga. Polymorphism information content (PIC) values of the 13 qualitative morphological characters (QMC) were in the range of 0.0950 to 8863 with an average of 0.4611. PIC value of seed shape, seed colour, hilum colour were 0.7403, 0.8177, 0.883 respectively. Cluster analysis based on QMC detected three main clades. V. cracca, V. amurensis, V. amoena were involved in Group 1 and V. unijuga f. minor, V. unijuga, V. unijuga f. angustifolia, V. sepium, V. hirticalycina, V. hirsuta, V. linearfolia, V. chosenensis, V. pseudorobus, V. venosa var. cuspidata were involved in Group 2. V. nipponica, V. japonica, V. villosa, V. dasicarpa, V. bungei, V. angustifolia, V. tetrasperma were clustered in Group 3. Our research suggests that morphological characteristic and testa texture of seeds could be used as definers for the identification of genus Vicia.

  • PDF

A Study on Material Characteristics and Manufacturing Techniques for Gold-granule Beads Excavated from the Neungsan-ri Temple Site in Buyeo (부여 능산리사지 출토 금제구슬의 재료학적 특성 및 제작기법 연구)

  • Yang, Soohyeon;Ro, Jihyun
    • Conservation Science in Museum
    • /
    • v.26
    • /
    • pp.67-82
    • /
    • 2021
  • Two golden beads (Buyeo 5336) housed at the Buyeo National Museum were discovered in 1993 near the site of an ancient workshop in Neungsan-ri in Buyeo-gun, Chungcheongnam-do Province. These rare examples from the Baekje Kingdom of an application of granulation have maintained their original form intact, and thus serve as important materials for the investigation of production techniques applied. This study analyzed the composition of the golden beads using a portable X-ray fluorescence analyzer, a stereo microscope, and a scanning electron microscope with an energy dispersive X-ray spectrometer. The manufacturing technique was examined through the observation of the micro-shape and the surface condition and by a composition analysis of the joint part. In both beads, a hole was pierced in a hollow body and the bead was decorated with golden wires around the hole and gold granules in other parts. In some areas, golden granules had been attached to the gold plate and golden wires were then placed over the granules. The purity of both the wires and the granules was analyzed as 23.6 - 23.7K. A high copper content was detected in some of the parts where the granules were attached. The findings of a previous reproduction experiment and study of production methods suggest that the beads were made using the copper diffusion technique.

The effect of blasting and anodizing-combined treatment of implant surface on response of osteoblast-like cell (분사처리 후 양극산화 처리한 임플란트 표면이 골모 유사 세포의 반응에 미치는 영향)

  • Seo, Bo-Yong;Kim, Young-Min;Choi, Jae-Won;Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo;Kim, Gyu-Cheon;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.9-18
    • /
    • 2015
  • Purpose: The purpose of this study is to examine characteristics of implant surface with RBM and anodizing treatments, and to evaluate the responses of osteoblast-like cell (MG-63 cell). Materials and methods: Grade IV titanium disks were fabricated (Diameter 10 mm, thickness 3 mm). Anodizing treatment (ASD) group, RBM and anodizing treatment (RBM/ASD) group, control (machined surface) group were divided. In this study, osteoblast-like cell was used for experiments. The experiments consist of surface characteristics evaluation by FE-SEM images, energy dispersive spectroscopy and stereo-SEM. In order to evaluate cell adhesion evaluation by crystal violet assay and observe cells form by confocal laser microscopy. To assess cell proliferation by XTT assay, cell differentiation by RT-PCR and mineralization by Alizarin red S stain assay. ELISA analyzer was used for Quantitative evaluation. Comparative analysis was run by one-way ANOVA (SPSS version 18.0). Differences were considered statistically significant at P<.05. Results: In ASD group and RBM/ASD group, the surface shape of the crater was observed and components of oxygen and phosphate ions in comparison with the control group were detected. The surface average roughness was obtained $0.08{\pm}0.04{\mu}m$ in the control group, $0.52{\pm}0.14{\mu}m$ in ASD group and $1.45{\pm}0.25{\mu}m$ in RBM/ASD group. In cell response experiments, ASD group and RBM/ASD group were significantly higher values than control group in cell adhesion and mineralization phase, control group was the highest values in the proliferative phase. In RT-PCR experiments, RBM/ASD group was showed higher ALP activity than other groups. RBM/ASD group in comparison with ASD group was significantly higher value for cell adhesion and proliferation phase. Conclusion: In the limitation of this study, we are concluded that the surface treatment with RBM/ASD seems more effective than ASD alone or machined surface on cellular response.

A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.