• Title/Summary/Keyword: step-changed

Search Result 554, Processing Time 0.039 seconds

Numerical Simulation of the Formation of Linear Dunes

  • ZHANG Ruyan;SATO Yuko;KAN Makiko;KAWAMURA Tetuya
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.211-212
    • /
    • 2003
  • Three dimensional flow above a sand dune has been studied numerically by using Large-Eddy Simulation (LES) method. The movement of the sand which is formed by converging wind directions has been investigated. The numerical method employed in this study can be divided into three parts: (i) calculation of the air flow above the sand dune using MAC method with a generalized coordinate system; (ii) estimation of the sand transfer caused by the flow through the friction; (iii) determination of the shape of the sand surface. Since the computational area has been changed due to step (iii), (i)­(iii) are repeated. The simulated dune, which has initially elliptic cross section, extending at the converging direction which is known as linear dunes.

  • PDF

A Study on Correction of CIRCLE Product Error by Prototype using Rapid Prototyping System (RP시스템을 이용한 원형시제품 제작 시 제품 오차 보정에 관한 연구)

  • Kim, Won-Jung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.146-153
    • /
    • 2012
  • RP system which is widely used to reduce the time of product development is to resolve the problem of cutting work. It is a method using laminated thin films to produce many forms. The RP equipment used for this experiment is FDM system. This can produce 3D model with using 3D CAD designed file within a relatively short time. Not only this, this system also through 3D file preparation, 3D product manufacture, removal support these 3 step operating process can easily produce goods, but product can be different from original design. This research has been conducted to minimize this error. To apply to the circular product made a circular specimen and measured several times with 3D scanner and find out average 99.622% of accuracy. This result is applied to RP system, and with this changed design produced a specimen, and found out the accuracy is increased to 99.958%. If this is applied to circular products, we can produce more precise products with less process.

Web Service Application for Machine Tool Fault with Open Architecture CNC (개방형 CNC를 가지는 공작기계의 고장진단과 웹 서비스 기술)

  • 김동훈;김선호;윤원수;고광식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.121-124
    • /
    • 2003
  • The conventional CNC(Computerized Numerical Controller) of machine tool, which is dependent to CNC maker, was a closed architecture type. Therefore, it is impossible to implement a special user-define function to CNC. But recently, CNC is changed to OAC(Open Architecture Controller) type increasingly and the general function of CNC can be upgrade efficiently. This paper describes web service application for remote monitoring regarding the faults or machine tool with open architecture CNC. The major faults of CNC machine tool can be defined to the operational faults to be charged over 70%. Those faults are unpredictable because of being occurred without any warning. To generalize the fault diagnosis efficiently. two diagnosis models such as SF(Switching Function) and SSF(Step Switching Function) are proposed and the function of fault diagnosis is implemented to internal function of OAC. Also, to service remotely the faults of CNC machine tool. the suitable web environment is proposed and practical function is programmed to evaluate its operation on web.

  • PDF

Study on Robust Control for Proportional Pressure Control Valve with MRC (MRC를 이용한 비례압력제어밸브의 강인한 제어에 관한 연구)

  • Yun, So-Nam;Jeong, Hwang-Hun;Lee, Ill-Young
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.77-84
    • /
    • 2013
  • The proportional pressure control valve that was used to relief valve has different dynamic characteristics on each case. Because this valve has different assembling or processing error and environmental condition. However, a customer who used the relief valve wants to have a steadily performance even if the dynamic characteristics of valve was changed. For this reason, the manufacturer try to make the robust controller that has simple structure. This paper concerns about the design of robust controller that didn't affected by plant parameter's changing. The control strategy is a model reference control that conducted by on line identification problem, gradient method and Lyapunov equation. This adaptvie control law's validity that this paper deal with was confirmed by an results of step response test or hysteresis test.

Characterization of a Micro Power Generator using a Fabricated Electroplated Coil Measured at Low Frequency (금도금 방법으로 제작한 코일을 이용한 초소형 발전기의 저주파 진동 특성분석)

  • Lee, Dong-Ho;Kim, Seong-Il;Lee, Yoon-Pyo;Baek, Chang-Wook
    • New & Renewable Energy
    • /
    • v.2 no.3
    • /
    • pp.10-14
    • /
    • 2006
  • We have designed and fabricated coil structures by gold electroplating technique. The thickness, width, and length are $7{\mu}m,\;20{\mu}m$, and 1.6m, respectively. With vibrating a magnet on the surface of a fabricated electroplated coil, the micro power generator produce an alternating voltage. We have changed the vibrational frequency from 0.5Hz to 8Hz. The generated voltage was 106mV at 3Hz and 198mV at 6Hz. We have rectified and stepped up the input voltage using a quadrupler circuit. After using the step up circuit, the measured voltage was 81mV at 3Hz and 235mV at 6Hz.

  • PDF

Studies on the Light Fastness of Dyeings (Part 1) The State of Direct Dyes in Cellulose (preliminary report (染色物의 日光에 對한 堅牢性에 關한 硏究 (第1報) 直接染料로 染色된 纖維素 纖維內에 있어서의 染料의 存在狀態 (豫報))

  • Ha, Wan-Shik
    • Journal of the Korean Chemical Society
    • /
    • v.6 no.2
    • /
    • pp.104-107
    • /
    • 1962
  • It is thought that the adsorption isotherms in dyeing of cellulose by the direct cotton dyes are consisted of combined type of Langmuir and Freundlich as the opinion of Fujino, et al;$[D]_F=ab[D]_S/(1+b[D]_S)+k[D]_S$where a,b,k; constants, $[D]_F$; dye adsorption on the fiber, $[D]_S$; dye concentration in the bath. This means that the dyes adsorbed in cellulose present in the state of partly mono molecular and partly aggregate; the characteristic fading order curve will be expressed as the combined system of uniform particle size distribution and assumed that the slope of the theoretical models of Baxter, et al., and assumed that the slope of curve will be changed near the point of a, the saturation value of Langmuir isotherms in the above equation. Firstly, the theoretical fading rate curve was treated with small colour difference as the one step of experimental of above consideration.

  • PDF

Step-wise Anion-Exchange in Layered Double Hydroxide Using Solvothermal Treatment

  • Lee, Jong-Hyeon;Rhee, Seog-Woo;Jung, Duk-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.2
    • /
    • pp.248-252
    • /
    • 2005
  • Synthetic layered double hydroxides (LDHs), [$Mg_4Al_2(OH)_{12}]CO_3{\cdot}nH_2O$, were prepared in the submicron size of plate-like polycrystals. Anion-exchange reactions with various linear dicarboxylic acids were performed to produce LDH/organic hybrid materials by solvothermal treatment in toluene. X-ray powder diffraction spectra for the products indicated that the interlayer spacings of LDHs remarkably changed, up to 20 $\AA$ when 1,10-decanedicarboxylic acid anions were intercalated as an organic guest. Dicarboxylates-LDHs samples could be also re-exchanged consecutively with other dicarboxylic acids or carbonate without serious destruction of layer structure under the scanning electron microscopic observation.

Person Recognition Using Gait and Face Features on Thermal Images (열 영상에서의 걸음걸이와 얼굴 특징을 이용한 개인 인식)

  • Kim, Sa-Mun;Lee, Dae-Jong;Lee, Ho-Hyun;Chun, Myung-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.2
    • /
    • pp.130-135
    • /
    • 2016
  • Gait recognition has advantage of non-contact type recognition. But It has disadvantage of low recognition rate when the pedestrian silhouette is changed due to bag or coat. In this paper, we proposed new method using combination of gait energy image feature and thermal face image feature. First, we extracted a face image which has optimal focusing value using human body rate and Tenengrad algorithm. Second step, we extracted features from gait energy image and thermal face image using linear discriminant analysis. Third, calculate euclidean distance between train data and test data, and optimize weights using genetic algorithm. Finally, we compute classification using nearest neighbor classification algorithm. So the proposed method shows a better result than the conventional method.

The Installable Maximum DG Capacity Considering LDC Parameters of ULTC and SVR in Distribution Systems (ULTC 와 SVR 이 설치된 배전계통에서 LDC Parameters 을 고려한 최대 DG 용량 산정)

  • Kim, Mi-Young;Hara, Ryoichi;Kita, Hiroyuki
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.27-28
    • /
    • 2008
  • For stable and sustainable energy supply, distributed generator (DG) has become an essential and indispensable element from environmental and energy security perspectives. However, installation of DG in distribution systems may cause negative affects on feeders because power outputs of DG could be changed irregularly. One of major negative affects is variation in voltage profile. In general, voltage regulation devices such as under load tap changer (ULTC) at distribution substation and step voltage regulator (SVR) along feeder in distribution system are used to maintain customers' receiving voltage within a predetermined range. These regulators are controlled by line drop compensation (LDC) method which calls for two parameters; the equivalent impedance and the load center voltage. Therefore, consideration of DG outputs in the LDC parameter design procedure may give large impact on the installable DG capacity. This paper proposes a method that estimates maximum Installable DG capacity considering LDC parameters of ULTC and SVR. The proposed algorithm is tested with model network.

  • PDF

The Detergency Improvement and Fabric Damage in the Washing Treatment by Commercial Bleaching Agents (시판표백제에 의한 농축세제의 세척성 향상과 섬유 손상)

  • 배정숙
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.2
    • /
    • pp.113-126
    • /
    • 1999
  • In order to investigate the detergency effect of stained cotton and PET fabric, respectively, these fabrics stained with solid soils such as carbon black, liquid paraffin, and fat and examined the detergency effect in the optimum washing condition. The evaluation of washing efficiency of washed fabrics studied by using the surface reflectance measurement before and after washing treatment. The maximum detergency effect of stained cotton and PET fabric obtained in the mixed washing liquor-bleachig agen(ml)/concentrated washig agent(g/l). To obtain the excellent detergency effect, 2-step washing treatment, pre-washing by bleaching agent only and washing by concentrated detergent, is preferred. In comparing the detergency of polyester and cotton fabric, the detergency of stained polyester fabric superior than that of stained cotton fabric because of the difference of adhesive force between soil material and fabric in preparing soled stained fabric. In this study, we also studied the degree of fabric damage by the measurement of tensile strength change. From the results of the tensile strength measurement, the damage of washed fabric before and after washing treatment was nearly changed.

  • PDF