• Title/Summary/Keyword: step up

Search Result 2,386, Processing Time 0.034 seconds

Electrical Characteristics of the Piezoelectric Transformer as a Function of Piezoelectric Properties and Load Variations (압전특성 및 부하변화에 따른 압전트랜스포머의 전기적 특성)

  • 민석규;윤광희;류주현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.4
    • /
    • pp.289-296
    • /
    • 2001
  • The piezoelectric transformers of 2.0x10x48 ㎣ size were fabricated with PSN-PMN-PZT(T10 and PNW-PMN-PZT(T2) composition ceramics. Effects of micro structural and piezoelectric properties on the electrical characteristics of the piezoelectric transformers were investigated. Under the fixed output power of 6 W, temperature rise of T1 transformer at the optimum load was smaller than T2 one because of fine grain size effect. Voltage step-up ratio of T1 transformer showed higher value than T2 one T1 transformer showed an excellent properties with voltage step-up ratio of 12.41, efficiency of 95.23% and temperature rise of 7.2$^{\circ}C$ at 200㏀ load resistance. And also, T2 transformer showed an excellent properties with voltage step up ratio of 9.81, efficiency of 95.51% and temperature rise of 9$^{\circ}C$ at 150㏀ load resistance.

  • PDF

Comparison of different ground contacts on muscle activation of post-stroke hemiparesis during step-up activity (계단 오르기 동안 지면 접촉 조건에 따른 뇌졸중 환자의 근활성도 비교)

  • Youn, Hye-Jin;Oh, Duck-Won;Kim, Kyung-Hwan;Ki, Kyong-Il
    • PNF and Movement
    • /
    • v.8 no.2
    • /
    • pp.9-15
    • /
    • 2010
  • Purpose : This study aimed to investigate the effect of differing ground contact conditions on the eletromyographic(EMG) activity in rectus femoris, biceps femoris, tibialis anterior, gastrocnemius medialis during step-up activity in patients with hemiparesis. Methods : 10 hemiparetic patients performed step-up activity on three different ground contact conditions: entire ground contact, 2/3 ground contact, 1/3 groud contact. Result : The EMG activities of gastrocnemius medialis significantly changed on 1/3 ground contact(p<.05). However, no significant changed rectus femoris, biceps femoris, tibialis anterior between three differing ground contact conditions (p>.05). Conclusion : This study provides that EMG activities of gastrocnemius medialis significantly changed on different ground contacts. Therefore, this method can be used to strengthen the gastrocnemius medialis.

  • PDF

Design and ANSYS Analysis of Disk-type Piezoelectric Transformer (디스크형 압전변압기의 설계 및 유한요소 해석)

  • Jung, Sung-Su;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.813-816
    • /
    • 2004
  • Unipoled piezoelectric transformers were designed with different input and output area ratios. The voltage step-up ratio increased proportionally with increasing the input area. The piezoelectric transformers operated in each transformer's resonance vibration mode. In this paper, ANSYS(FEM program) was used for analysing piezoelectric transformers. We compared with analysis and experimental results. The voltage step-up ratio showed maximum value in output area of small size. Output characteristics of piezoelectric transformers with various size were simulated. The result of analysis showed $2\sim7$ times higher voltage step-up ratio than a experiment result.

  • PDF

Two-Inductor Non-Isolated DC-DC Converter with High Step-Up Voltage Gain

  • Lee, Sze Sing;Chu, Bing;Lim, Chee Shen;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1069-1073
    • /
    • 2019
  • In this paper, an alternative non-isolated DC-DC converter with a high voltage boosting capability is proposed. Two inductors are used and one of them has its flux linkage increases during its charging period to achieve a high step-up voltage gain. Among the three integrated capacitors, one portrays the partial characteristic of the switched-capacitor technique, while the other two are connected in series across the load. With the two switches controlled using the same duty cycle, the proposed topology demonstrates the merits of a higher and wider range of step-up voltage gain when compared with recent topologies. In addition, a reduction in loss is induced and a higher efficiency is ensured with all the voltage stresses constrained within the output voltage. Operation of the proposed converter is analyzed and validated through experimental results obtained with a prototype.

Single-Phase Step-Up Five-Level Inverter with Phase-Shifted Pulse Width Modulation

  • Chen, Jianfei;Wang, Caisheng;Li, Jian
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.134-145
    • /
    • 2019
  • A single-phase step-up five-level inverter topology with a new phase-shifted pulse width modulation (PS-PWM) strategy is proposed in this paper. When compared with conventional single-phase five-level inverter topologies, the proposed topology can realize multilevel inversion with a double step-up ratio, a reduced number of switching devices and self-balanced capacitor voltages. When compared with the conventional PS-PWM strategy, the new PS-PWM strategy can be implemented with one carrier reduced, which makes it much easier to implement in a digital signal processor (DSP) system. Experimental results have been presented to verify the effectiveness of the proposed inverter and the PS-PWM strategy.

Double Step-Up PFC Converter Using Asymmetrical PWM Scheme (비대칭 PWM 방식을 이용한 이중 승압 기능을 갖는 PFC 컨버터)

  • Yeongjin Kim;Jaeseong Lim;Honnyong Cha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.8-14
    • /
    • 2023
  • This paper proposes a PFC converter with a double step-up function using an asymmetrical PWM scheme. For the conventional PWM scheme, the input voltage range, which maintains a double step-up function, is limited because the proposed converter has different voltage gains and characteristics when the duty ratio(D) is less than 0.5. The proposed converter has a constant voltage gain regardless of the magnitude of the input voltage and can achieve output voltage balancing by using the asymmetrical PWM scheme. A 1.6-kW prototype of the proposed converter was built and tested to verify the performance.

Design of Low-Input-Voltage Step-Up Converter for Single Fuel Cell (단일 연료전지 셀을 위한 저입력 전압 승압 컨버터의 설계)

  • Lim, Jeong-Gyu;Park, Jin-Ju;Chung, Se-Kyo
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.152-153
    • /
    • 2010
  • This paper presents the design of a low-input-voltage step-up converter. Such circuits can be useful for single fuel cell to generate less than 0.7V. Important issues to design it are physical volume, efficiency and start-up method. In this paper, we propose a step-up converter with a simple start-up circuit. The operation of proposed circuit is presented and the experimental results are provided to verify the feasibility of the proposed technique.

  • PDF

The Buckling Characteristics of Single-Layer Lamella Domes according to Support Position under Construction (단층라멜라 돔의 시공 중 서포트 위치에 따른 좌굴특성)

  • Kim, Cheol-Hwan;Suk, Chang-Mok;Jung, Hwan-Mok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.4
    • /
    • pp.67-74
    • /
    • 2010
  • Single layer latticed domes which have a mechanics property, a functional property, a aesthetic property and so on, occupies one part of long span space structures and after this, the using parts will be extended. The frame network pattern of single-layer latticed domes can be infinitely taken into account. The typical network patterns are triangular, square, hexagon, lamella and rib etc. It would take long time and cost too much to erect large roof structures with traditional erection techniques due to require of large number of temporary bracing and supports. The erection of large roof structures requires special techniques. As one of these special techniques is the Step-Up election method that utilizes jack-up supports and this will extremely saves time and cost to erect large roof structures. The objective of this study is to analysis the buckling characteristics of single-layer lamella domes according to the support number and position. From the result of this study, we obtained the fundamental data for the structural engineers who design the temporary support of large roof structures.

  • PDF

Research on a New 12-Pulse Step-Up and Step-Down Aviation Auto-Transformer Rectifier

  • Jiang, Fan;Ge, Hong-juan;Dong, Xiao-xu;Zhang, Lu
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.266-276
    • /
    • 2018
  • This paper presents a new step-up and step-down multi-pulse auto-transformer rectifier unit (ATRU) topology. This structure can achieve a wide range of output voltages, which solves the problem of auto-transformer output voltage being difficult to regulate. Adding middle taps to the primary winding and reasonably setting the number of auto-transformer windings, constituted two groups of three-phase output voltages with a $30^{\circ}$ phase difference. Multi-pulse output DC voltage is obtained after a three-phase output voltage across two rectifier bridges and inter-phase reactor. Thus, the output DC voltage is related to the number and configuration of the auto-transformer winding. In this paper, the relationship between the voltage ratio of the auto-transformer and the ratio of winding, input current and auto-transformer kilovoltampere rating are deduced and validated by simulations. On this basis, the output voltage range is optimized. An experiment on two different voltage ratio principle prototypes was carried out to verify the correctness of the analysis design.

Establishment of Criteria for the Evaluation of Headgear and Ornaments for Diadem in the Period of the Three States (삼국시대 관모 및 관식 유물 감정을 위한 기준 설정)

  • Kim, Moon-Ja
    • Journal of the Korean Society of Costume
    • /
    • v.58 no.5
    • /
    • pp.13-34
    • /
    • 2008
  • In Headgear and Ornaments for Diadem in the Period of the Three States there was Conical Cap(or Pointed Cap), Feathered Cap(Trim), and Crown[Tree-typed Diadem and Tree and Antler-typed Diadem] was excavated from the tombs. Feathered Trim is 5 types, Feathered Trim I-A, Feathered Trim I-B, Feathered Trim II-A, Feathered Trim II-B, Feathered Trim II-C in according to upper part of central insert plate style. Feathered Trim I-A, I-B, II-B type was general style that was found in most of the old tombs in ancient Silla, Gaya. Feathered Trim II-A type was excavated from the only Silla tombs and II-C type was excavated from Gaya tombs. The Ornaments for Diadem in Baekje was excavated from the tombs is adorned with a arranged leaf-stems on either sides and the flower-shaped. They were distinguished with the original mode of Goguryeo and ancient Silla at the time. Tree-typed Diadem is five part in according to the Mountain(;山)-typed piled up. Only one Mountain(;山)-typed one in three stand-up ornament(I-1 type), and three step one in three stand-up one(I-2 type), modification one (I-3 type), three step one of four and five stand-up ones(I-4 type), and four step one of four and five stand-up ones (I-5 type). Tree and Antler-typed Diadem is three part in according to the step of Mountain(; 山)-typed and cross-shaped of the upper part. Three one of three step one of Mountain(;山)-typed and two Antler- typed (II-1 type), cross-shaped one(II-2 type), four step one(II-3 type).