• 제목/요약/키워드: step speed

검색결과 1,445건 처리시간 0.023초

Hand & rotary root canal instrument의 근관내 삭제 형태에 관한 전자현미경적 비교 (SEM EVALUATION OF THE PREPARED ROOT CANALS BY HAND AND Ni-Ti ROTARY ROOT CANAL INSTRUMENTS)

  • 오태석;박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.477-486
    • /
    • 1998
  • Recently the development of rotary instrument makes it possible that in root canal treatment operator saves much more time, maintans original curved canal shape and easily prepares continuous tapered root canal. The purpose of this experiment was to examine the smoothness of the internal surface of prepared root canal and the effectiveness of debridement in prepared root canal by SEM for the comparison of hand and Ni-Ti rotary instrument. 25 extracted human teeth were access opened and # 10 K-type file was introduced into canal until it was appeared at the apical foramen. The working length was established by subtracting 0.5mm from this measurement. Group 1. The root canal preparation was done to # 30 with working length and then step-back until # 45 with K-Flexofile (Maillefer, Swiss). Group 2. Root canal preparation was done by Naviflex Ni-Ti file (Brasseler, USA) as the same technique with group 1. Group 3. Canal was prepared by Profile .04 (Maillefer, Swiss) taper until #30. Group 4. With use of Quantec (Tycom, USA) root canal was prepared from file number 1 to 8. In group 1 and 2, the root canal irrigant was NaOCl and the other groups, NaOCl and RC-prep (Premine Dental Products, USA) was used. The prepared teeth were notched with high-speed bur as bucco-lingual direction and fractured with chisel and mallet, then examined with SEM. Group 1 showed smooth internal surface. There were scratches mainly to the axial direction. Group 2 showed similar characteristics to those in group 1. Group 3 showed more smoother and linear cutting surface with bised scratches. Group 4 has the almost same characteristics group 3 and there was no difference in the file design. Ni-Ti rotary root canal instrument prepare the dentinal wall more smoother than hand instrument. The effectiveness of debridement was not fully affected by file design. The isthmus area and accessory canals of the root canal system were not prepared in any group. According to the result, hand and rotary type instrumentation techniques were effective in removal of major amount of tissue from root canal but it was not complete. In the direction of cutting movement there was difference between them.

  • PDF

산부식후 상아질 표면의 습윤 또는 건조가 상아질 결합에 미치는 영향 (EFFECTS OF DENTIN SURFACE WETNESS OR DESICCATION AFTER ACID ETCHING ON DENTIN BONDING)

  • 양원경;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.243-253
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate dentin bonding by two different dentin bonding systems(DBS) using acetone based primer or adhesive [All Bond 2(AB2), One Step(OS)] when they were applied by wet or dry bonding technique. Morphology of resin-dentin interface and hybrid layer thickness(HLT) were investigated using Confocal Laser Scanning Microscope(CLSM) and compared to shear bond strength(SBS). 72 extracted sound human molars were randomly divided into 4 groups of 18 teeth each - Group 1.(AW); AB2 by wet bonding. Group 2(AD); AB2 by dry bonding. Group 3.(OW); OS by wet bonding, Group 4.(OD); OS by dry bonding. In 6 teeth of each group, notch-shaped class V cavities(depth 2mm) were prepared on buccal and lingual surface at the cementoenamel juction(12 cavities per group). To obtain color contrast in CLSM observation, bonding resins of each DBS were mixed with rhodamine B and primer of AB2 was mixed with sodium fluorescein. Prepared teeth of each group were treated with AB2, OS, respectively according to the manufacturer's instructions except for dentin surface moisture treatment after acid etching. In group 1 and 3, after acid etching, excess water was removed with wet tissue(Kimwipes), leaving consistently shiny, visibly hydrated dentin surface. In group 2 and 4, dentin surface was dried for 10 seconds at 1 inch distance. The treated teeth were then packed with composite resin(${\AE}$litefil) and light-cured. 12 microscopic samples($60{\sim}80{\mu}m$ thickness) of each group were obtained after longitudinal section and grinding(Exakt cutting and grinding system). Morphological investigation of resin-dentin interface and HLT measurement using CLSM were done. For measurement of SBS, remaining 12 teeth of each group were flattened occlusally to remove all enamel and grinded to 500 grit SiC(Pedemet Specimen Preparation Equipment). After applying DBS on the exposed dentin surface, composite resin was applied in the shape of cylinder, which has 5mm diameter, 1.5mm thickness, and light cured. SBS was measured using Instron with a crosshead speed of 0.5mm/min. It was concluded as follows, 1. HLT of AW(mean: $2.59{\mu}m$) was thicker than any other group, and followed by AD, OW, OD in descending order(mean; 2.37, 2.28, $1.92{\mu}m$). Only OD had statistically significant differences(p<0.05) to AW and AD. 2. There were intimate contact of resin and dentin at the interface in wet bonding groups, but gaps or irregular interfaces were observed in dry bonding groups. 3. The length, diameter, density of resin tags were various even in the same group without significant differences between groups and lots of adhesive lateral branches were observed. 4. There were no statistically significant difference of SBS between AB2 and OS, but SBS of wet bonding groups were significantly higher(p<0.05) than dry bonding groups. 5. There were no consistent relationships between HLT and SBS.

  • PDF

상아질의 경도, 위치 및 잔존 상아질 후경이 상아질에 대한 부위별 미세 전단결합강도에 미치는 영향 (REGIONAL MICRO-SHEAR BOND STRENGTH TO DENTIN:EFFECTS OF DENTINAL HARDNESS, POSITION, AND REMAINING DENTIN THICKNESS)

  • 황선성;임미경;이용근
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.401-412
    • /
    • 1998
  • The aim of this study was to measure the regional micro-shear bond strength of dentin bonding agents to dentin, and to investigate the relationship between the micro-shear bond strength and two dentinal characteristics ; Vickers hardness and remaining dentin thickness. Twenty-four freshly extracted, noncarious human molars were selected for this study. The materials tested in this study consisted of two commercially available dentin bonding agents (MAC-BOND, ONE-STEP) and two restorative light-cured composite resins (AELITEFIL, Z100). The occlusal or side surface of tooth crown was sectioned to expose dentin, and the exposed surface was finally polished with # 600 sandpaper. Four groups of application methods were used combining the filling materials and the dentin bonding agents. The composite resin-attached tooth specimens were embeded in a cold cure acrylic resin, and were cut with a low speed diamond saw to the dimension of 1mm $\times$ 1mm. Nine specimens were obtained from each tooth. The cut specimens were divided into three groups depending on the position of the dentin bonding surface. The micro-shear bond strength, remaining dentin thickness, and dentinal hardness were measured. Experimental results were then statistically analyzed with ANOVA. t-test, Scheffe test, and regression analysis. From this experiment, the following results were obtained : 1. In the case of occlusal surface bonding, the pooled micro-shear bond strength of ONST-AELIT group (16.62 MPa) was significantly higher than that of MACB-AELIT group (9.91 MPa) (p<0.05). However, there was no significant difference in the micro-shear bond strength depending on the dentin position (p>0.05). 2. In the case of side surface bonding of crown, the pooled micro-shear bond strength of four different bonding groups was not significantly different among each other (p>0.05). However, in three of the test groups (ONST-AELIT, MACB-Z100, ONST-Z100), the micro-shear bond strength to the lower 1/3(III) position was significantly lower than that to middle 1/3(II) position of surface (p<0.05). 3. In the ONST-AELIT bonding group, the pooled micro-shear bond strength to the occlusal surface was significantly lower than that to the side surface of crown (p<0.05). 4. There was no significant correlation between the micro-shear bond strength and dentin hardness / remaining dentin thickness (p>0.05).

  • PDF

트위터 기반 이벤트 탐지에서의 기계학습을 통한 지명 노이즈제거 (Geographical Name Denoising by Machine Learning of Event Detection Based on Twitter)

  • 우승민;황병연
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제4권10호
    • /
    • pp.447-454
    • /
    • 2015
  • 본 논문에서는 트위터 기반 이벤트 탐지에서의 기계학습을 통한 지명 노이즈제거 방식을 제안한다. 최근 스마트폰 이용자의 증가로 소셜 네트워크 서비스(SNS) 이용자가 증가하고 있는 추세이다. 그중 트위터는 140자 이내의 단문서비스와 팔로우 기능으로 정보의 빠른 전달력과 확산성을 가지고 있다. 이러한 특성과 모바일에 최적화된 트위터의 특성상 정보 전달 속도가 매우 빠르기 때문에 재난 상황이나 이벤트 전달의 매개체 역할을 하고 있다. 이와 관련된 연구로는 트위터 사용자 개개인을 이벤트 탐지의 센서로 사용하여 현실에서 발생하는 이벤트를 탐지하였는데 이벤트가 특정 장소에서 발생한다는 특성을 이용해서 지명 키워드를 사용하였다. 그러나 지명과 동형이의어 관계에 관한 노이즈제거에 대한 부분이 누락되어있어서 이벤트 탐지의 정확도를 낮추는 요인이 된다. 이에 본 논문에서는 제거와 예측 두 가지 방식으로 노이즈제거 기법을 적용하였다. 먼저 노이즈 관련 데이터베이스 구축을 이용하여 제거 필터링을 진행한 후에 나이브 베이지안 분류를 이용해서 지명 유무를 결정하였다. 실험 데이터를 이용해서 기계학습을 위한 확률값을 구했으며, 지명마다 본 논문에서 제시하는 예측기법을 검증했을 때 89.6%의 신뢰도로 노이즈제거 기법의 필요성을 보였다.

단순 퍼지 제어기법을 이용한 온실의 천창환기에 의한 냉방제어 (Cooling Control of Greenhouse Using Roof Window Ventilation by Simple Fuzzy Algorithm)

  • 민영봉;윤용철;허무룡;강동현;김현태
    • 농업생명과학연구
    • /
    • 제44권4호
    • /
    • pp.69-77
    • /
    • 2010
  • 온실의 환기제어시 외기온도와 풍속변화에 보다 유연하게 대처하면서 온실내 온도제어성능을 향상시키기 위해서 퍼지제어가 많이 이용되고 있지만, 제어로직이 복잡하여 대용량 메모리를 갖는 컨트롤러가 필요하다. 본 연구에서는 소용량의 마이크로 컨트롤러에서 프로그램이 가능한 단순퍼지제어 알고리즘을 개발하여 시험하였다. 개발한 단순퍼지 제어 알고리즘의 성능을 비교하기 위하여 기존의 스텝제어 알고리즘을 도입한 제어프로그램으로 온실의 천창환기에 의한 온도제어를 실시하여 두 알고리즘의 성능을 직접 비교하고, 또 PID 및 표준 퍼지제어 성능과는 기존의 연구 결과와 비교하여 상대적 성능을 평가하므로써 온실의 환기냉방제어의 유리한 제어기법을 확립할 수 있는 기초자료를 얻고자 수행하였다. 단순 퍼지제어에 의한 실내온도 최대 제어오차는 $1.2^{\circ}C$, 1시간동안의 평균환기창 적산열림량과 조작회수는 각각 84%, 13회로 나타났으며, 문헌조사에 의한 퍼지제어에서 각각 $1.3^{\circ}C$, 75% 및 12회에 비해 동등한 제어성능을 보였다. 본 연구에서 개발한 단순퍼지제어는 제어로직이 PID제어보다 단순함에도 불구하고 스텝제어와 PID제어보다 성능이 우수하고, 퍼지제어와 동등한 제어성능을 갖는 것으로 나타났다.

수중용 TAS윈치 전개/회수 성능 안정화 방안에 관한 연구 (A Study on Stabilization of Underwater TAS Winch System Deploy/Recover Operation Performance)

  • 장호성;조규룡;황재교;이상용;김용태
    • 한국산학기술학회논문지
    • /
    • 제20권6호
    • /
    • pp.472-482
    • /
    • 2019
  • 본 논문은 수중용 TAS윈치 전개/회수 성능 안정화 방안에 대한 내용을 서술하고 있다. TAS윈치는 함미에 장착되어 자함과 이격되어 운용되는 센서, 예인케이블 및 꼬리로프의 전개/회수 기능을 수행하고, TAS에 대한 전원공급 경로, 수중환경 정보 및 수신된 음향신호 송/수신을 위한 데이터 전송 경로 제공 역할을 수행한다. TAS윈치 시험평가 과정에서 간헐적으로 TAS 전개 중 멈춤현상 및 회전속도 변동현상이 식별되었다. TAS 전개/회수에 필요한 토크를 제공하는 구성요소인 윈치모터에 대한 고장분석 결과, 구성품 중 회전자의 정렬 틀어짐으로 인한 편심현상에 따른 자기장 왜곡이 발생한 것을 확인하였다. 자기장 왜곡 발생 방지를 위해 윈치모터 회전자 및 슬립링 등 윈치모터 구성품의 고정성 향상 방안을 제안하였다. 제안된 방안에 대한 신뢰성 확보를 위해 LBTS 환경에서 TAS윈치 운용환경을 모사하여 TAS윈치 전개/회수 성능을 검증하였다. 최종적으로 TAS윈치 전개/회수 성능 뿐만 아니라 해상에서 TAS윈치를 운용할 경우 요구되는 함 속력 및 타각별 TAS 지속 운용능력과 같은 여러 가지 항목에 대한 해상 시험평가를 수행함으로써 설계 요구조건 만족 및 제안 방안에 대한 타당성을 검증하였다.

소형 풍력발전시스템의 직류전원 적용을 위한 운전제어 및 AC/DC변환 통합장치 개발 (Development of Operation Control and AC/DC Conversion Integrated Device for DC Power Application of Small Wind Power Generation System)

  • 홍경진
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권3호
    • /
    • pp.179-184
    • /
    • 2019
  • 전기가 부족한 개발도상국 같은 많은 나라에서는 Off Grid 형태의 소형풍력발전이 전력공급 문제를 해결하기 위한 효율적인 핵심 솔루션이다. 몇몇 국가에서는 전력계통의 확장과 전기가 부족한 지역의 감소로 소규모 풍력을 도시의 도로 조명, 모바일 통신 기지국, 양식업 및 해수 담수 등의 분야에 이용하기도 한다. 이런 변화에 따라 소형 풍력 산업 규모는 대규모 풍력보다 큰 잠재력이 기대되고 있다. 소형 풍력발전의 경우 발전기는 가변 속도로 제어되는 특성이 있으며 발전기에서 발생하는 전압 및 전류에는 많은 고조파 성분을 가지고 있다. 이를 해결하기 위해서 본 논문에서는 소형 풍력발전시스템의 직류전원 적용을 위한 운전제어 및 AC/DC 변환 통합장치를 제안하며 기존 AC to DC 컨버터는 단일 스위치를 갖는 3상 승압형 방식의 컨버터로서 인덕터 전류가 불연속모드로 제어되며, 입력전류의 고조파를 제거하여 단위역률을 갖는 특성을 갖는다. 제안된 컨버터는 입력단에 LCL 필터 및 3상 정류 승압형 컨버터, 계통연계를 위한 단상 풀브릿지 형태로 구성되어 있으며 에너지저장시스템(ESS) 기능이 부가된 제어 시스템으로 풍력발전을 이동 평준화 방식에 의해 급변하는 전력에 대해 계통 안정화를 추구할 수 있다.

중심합성계획법 기반 이중유전자알고리즘을 활용한 차량추종모형 정산방법론 개발 (Calibration of Car-Following Models Using a Dual Genetic Algorithm with Central Composite Design)

  • 배범준;임현섭;소재현
    • 한국ITS학회 논문지
    • /
    • 제18권2호
    • /
    • pp.29-43
    • /
    • 2019
  • 미시적 교통류 모형의 정산은 시뮬레이션 분석에 있어 매우 중요한 요소이다. 유전자 알고리즘은 교통류 모형의 정산에 널리 활용되어 왔으며, 일반적으로 이러한 최적화 문제에 있어 높은 효율성을 보이는 것으로 알려져 있다. 하지만 제한된 시간내에 신속한 의사결정을 위한 시뮬레이션 분석에 있어 유전자알고리즘의 모형 정산속도는 여전히 느리다. 이에 본 연구에서는 정산 효율 향상을 위해 중심합성계획법 기반의 이중유전자알고리즘을 활용한 차량추종모형 정산방법론을 개발하였다. 개발된 정산 방법론에서는 실험계획법 중 하나인 중심합성계획법과 유전자알고리즘을 결합하여 준최적해를 찾고, 이를 다시 유전자알고리즘의 초기 값으로 하여 모형 파라미터의 최적해를 찾는다. 개발된 방법을 활용하여 Gipps의 차량추종모형을 정산하였다. 선행연구에서 사용된 단일 유전자알고리즘을 활용한 방법과 비교한 결과, 본 연구에서 개발한 방법이 더 짧은 시간내에 최적해를 찾는 것으로 확인되었다. 개발된 방법론은 유전자알고리즘을 사용하는 다양한 교통분석에 활용될 수 있을 것으로 기대된다.

복원용 밥의 미생물 안전성 및 식감 향상을 위한 저온 숙성 및 건조 처리 (Low-temperature aging and drying treatments of restorative rice to improve its microbial safety and texture)

  • 천희순;조원일;정명수;최준봉
    • 한국식품과학회지
    • /
    • 제51권1호
    • /
    • pp.29-34
    • /
    • 2019
  • 본 연구의 침지쌀을 $90-100^{\circ}C$의 온도에서 1, 2차 증숙한 다음 $0-10^{\circ}C$의 냉장저온에서 숙성하는 1단계 처리와 이어 상대습도 85%, $-20^{\circ}C$에서 냉동하는 2단계 그리고 $1-20^{\circ}C$의 상압에서 5 m/s 풍속으로 저온 건조하는 3단계로 구성된 최종 수분함량 30% 인복원용 밥의 제조방법은 기존 열풍건조 대비 관능품질을 향상시키고 상온 3개월 내외의 보관을 가능하게 하였다. 구체적인 효과는 2단계 증숙 및 저온 장시간 건조 과정을 통해 개선된 복원용 밥의 수분함량이 기존 건조밥의 7% 대비 4.3배 높고 쌀알의 고유 형태가 잘 유지되어 있어 취식을 위한 열수 복원시 전반맛, 식감과 외관이 관능평가에서 통계적 유의 있게 향상되었다(p<0.05). 또한 수분 30% 수준은 최적의 관능품질을 나타내면서 미생물 생육을 저해하여 저장성을 향상시키는 조건으로 파악되었다. 이러한 품질 및 저장성 향상 효과가 있는 처리 방법을 멥쌀, 찹쌀, 밀, 콩, 메밀 및 보리 등의 다양한 곡물을 이용한 복원용 밥 제품의 제조에 적용할 수 있어 상업적 활용성이 매우 높다고 할 수 있다.

균형과 보행분석을 위한 스마트 인솔의 신뢰도와 타당도 분석 (The Reliability and Validity of Smart Insole for Balance and Gait Analysis)

  • 이병권;한동욱;김창용;김기영;박대성
    • 대한통합의학회지
    • /
    • 제9권4호
    • /
    • pp.291-298
    • /
    • 2021
  • Purpose: The Pedisole is a newly developed shoe-mounted wearable assessment system for analyzing balance and gait. This study aimed to determine the reliability and validity of the parameters provided by the system for static balance and gait analysis of healthy adults. Methods: This study included 38 healthy adults (22.4±1.9 years) with no history of injury in the lower limbs. All participants were asked to perform balance and gait tasks for undertaking measurements. For analysis of balance, both the smart Pedisole and Pedoscan systems were concurrently used to analyze the path length of the center of pressure (COP) and the weight ratio of the left and right for 10 s. Gait was measured using the smart Pedisole and GaitRite walkway systems simultaneously. The participants walked at a self-selected preferred gait speed. The cadence, stance time, swing time, and step time were used to analyze gait characteristics. Using the paired t-test, the intra-class coefficient correlation (ICC) was calculated for reliability. The Spearman correlation was used to assess the validity of the measurements. In total, data for balance from 36 participants and the gait profiles of 37 participants were evaluated. Results: There were significant differences between the COP path lengths (p<.050) derived from the two systems, and a significant correlation was found for COP path length (r=.382~.523) for static balance. The ICC for COP path length and weight ratio was found to be greater than .687, indicating moderate agreement in balance parameters. The ICC of gait parameters was found to be greater than .697 except for stance time, and there was significant correlation (r=.678~.922) with the GaitRite system. Conclusion: The newly developed smart insole-type Pedisole system and the related application are useful, reliable, and valid tools for balance and gait analysis compared to the gold standard Pedoscan and the GaitRite systems in healthy individuals.