• Title/Summary/Keyword: stents

Search Result 315, Processing Time 0.028 seconds

Advances in self-expandable metal stents for endoscopic ultrasound-guided interventions

  • Dong Kee Jang;Dong Wook Lee;Seong-Hun Kim;Kwang Bum Cho;Sundeep Lakhtakia
    • Clinical Endoscopy
    • /
    • v.57 no.5
    • /
    • pp.588-594
    • /
    • 2024
  • Endoscopic ultrasound (EUS)-guided interventions have evolved rapidly in recent years, with dedicated metal stents playing a crucial role in this process. Specifically, the invention of biflanged short metal-covered stents, including lumen-apposing metal stents (LAMS), and modifications in a variety of tubular self-expandable metal stents (SEMS), have led to innovations in EUS-guided interventions. LAMS or non-LAMS stents are commonly used in the EUS-guided drainage of pancreatic fluid collections, especially in cases of walled-off necrosis. Additionally, LAMS is commonly considered for drainage of the EUS-guided gallbladder or dilated common bile duct and EUS-guided gastroenterostomy. Fully or partially covered tubular SEMS with several new designs are being considered for EUS-guided biliary drainage. This review focuses on advances in SEMS for EUS-guided interventions and discusses related research results.

Flexibile Analysis of Coronary Stents due to Loading Directions (하중 방향에 따른 관상동맥용 스텐트의 유연성 해석)

  • 조승관;조은정;김한성
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.331-334
    • /
    • 2004
  • In clinical use, coronary stents keep coronary arteries open after expansion with a balloon catheter and prevent the expanded artery from collapsing. Coronary stents are positioned in artery by catheter with a balloon along a guide wire to the lesion site. Flexibility is one of important ability for delivery. In this paper, Palmaz-Schatz stent and Tenax complete stent were selected because these are the most representative of tubular stents. Finite element analyses for the stent system were performed using ABAQUS/Standard code. The present study estimated the flexibility of coronary stents due to loading directions. Moreover the present paper suggests a numerical method to test the flexibility of stents. In conclusion this paper shows how the finite element analysis can be effectively organized in the stent development.

  • PDF

THE PROBLEMS OF EXPANDABLE METALLIC STENT FOR THE TREATMENT OF SUBGLOTTIC TRACHEAL AND TRACHEOSTOMAL STENOSIS (성문하 기관 및 기관누공 협착증에 대한 팽창성 금속 스텐트의 문제점)

  • 홍기환;정경호;김중호;한영민
    • Korean Journal of Bronchoesophagology
    • /
    • v.2 no.2
    • /
    • pp.213-221
    • /
    • 1996
  • To evaluate the clinical effectiveness of expandable metallic stents, the stents were implanted under endoscopic guidance with local anesthesia or general anesthesia for maintenance of the constructed subglottic space of trachea. The nine patients with respiration difficulty were subjected for expandable stents. The stenosis of upper airway were due to the framework problem of subglottic trachea and tracheostoma after total laryngectomy. Stents were constructed of 0.4 m stainless steel win in a zigzag configuration of 8 bends. A single stent was 20 m in diameter when fully expanded and 20 mm long. The stents were placed accurately to the stenotic site and followed to the 5 month after stent placement. The stenotic area became narrowed with overgrowing of granuloma in all patients and the metallic stents were removed and the stenotic area reconstructed surgically. As conclusion, this technique for the treatment of the subglottic trachea showed simple and safe, but highly recurred due to overgrowing of granuloma. We suggest that the expandable metallic stent is not encouraging in this study.

  • PDF

A Study on Effects of EGCG and Design Parameter for Drug-Eluting Biodegradable Polymer Stents (약물-용출 생분해성 고분자 스텐트를 위한 EGCG와 디자인 파라미터의 영향에 대한 연구)

  • Jung, T.G.;Lee, J.H.;Lee, J.J.;Hyon, S.H.;Han, D.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.111-116
    • /
    • 2013
  • Finite element analysis(FEA) has been extensively applied in the analyses of biomechanical properties of stents. Geometrically, a closed-cell stent is an assembly of a number of repeated unit cells and exhibits periodicity in both longitudinal and circumferential directions. This study concentrates on various parameters of the FEA models for the analysis of drug-eluting biodegradable polymeric stents for application to the treatment of coronary artery disease. In order to determine the mechanical characteristics of biodegradable polymeric stents, FEA was used to model two different types of stents: tubular stents(TS) and helicoidal stents(HS). For this modeling, epigallocatechin-3-O-gallate (EGCG)-eluting poly[(L-lactide-co-${\varepsilon}$-caprolactone), PLCL] (E-PLCL) was chosen as drug-eluting stent materials. E-PLCL was prepared by blending PLCL with 5% EGCG as previously described. In addition, the effects of EGCG blending on the mechanical properties of PLCL were investigated for both types of stent models. EGCG did not affect tensile strength at break, but significantly increased elastic modulus of PLCL. It is suggested that FEA is a cost-effective method to improve the design of drug-eluting biodegradable polymeric stents.

Assessment of the Intracranial Stents Patency and Re-Stenosis by 16-Slice CT Angiography with Optimized Sharp Kernel : Preliminary Study

  • Choo, Ki-Seok;Lee, Tae-Hong;Choi, Chang-Hwa;Park, Kyung-Pil;Kim, Chang-Won;Kim, Suk
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.5
    • /
    • pp.284-288
    • /
    • 2009
  • Objective : Our retrospective study aimed to determine whether 16-slice computerized tomography (CT) angiography optimized sharp kernel is suitable for the evaluation of visibility, luminal patency and re-stenosis of intracranial stents in comparison with conventional angiography. Methods : Fifteen patients with symptomatic intracranial stenotic lesions underwent balloon expandable stent deployment of these lesions (10 middle cerebral arteries, 2 intracranial vertebral arteries, and 3 intracranial internal carotid arteries). CT angiography follow-up ranged from 6 to 15 months (mean follow-up, 8 months) after implantation of intracranial stents and conventional angiography was confirmed within 2 days. Curved multiplanar reformations with maximal intensity projection (MIP) with optimal window settings for assessment of lumen of intracranial stents were evaluated for visible lumen diameter, stent patency (contrast distal to the stent as an indirect sign), and re-stenosis by two experienced radiologists who blinded to the reports from the conventional angiography. Results : All of stents deployed into symptomatic stenotic lesions. All stents were classified as patent and no re-stenosis, which was correlated with results of conventional angiography. Parts of the stent lumen could be visualized in all cases. On average, 57% of the stent lumen diameter was visible using optimized sharp kernel. Significant improvement of lumen visualization (22%, p<0.01) was observed using the optimized sharp kernel compared with the standard sharp kernel. Inter-observer agreements on the measurement of lumen diameter and density were judged as good, respectively (p<0.05). Conclusion : Sixteen-slice CT using the optimized sharp kernel may provide a useful information for evaluation of lumen diameter patency, and re-stenosis of intracranial stents.

Surgical outcomes in dogs with tracheal collapse treated with a novel cross-and-hook braided endoluminal stent

  • Uemura, Akiko;Ozai, Yusuke;Hamabe, Lina;Yoshida, Tomohiko;Tanaka, Ryou
    • Journal of Veterinary Science
    • /
    • v.23 no.3
    • /
    • pp.46.1-46.8
    • /
    • 2022
  • Background: Stenting is an effective treatment option for tracheal collapse in dogs. Cross-braided tracheal stents are currently the norm in veterinary medicine, but cross-and-hook braided stents have recently been adopted in human medicine. We examined whether stents manufactured using this novel braiding technique provided additional advantages for the treatment of tracheal collapse in dogs. Objectives: To evaluate the outcomes of cross-and-hook braided stent implantation in the treatment of tracheal collapse in dogs. Methods: The medical records of 22 client-owned dogs that underwent luminal placement of cross-and-hook braided Fauna Stents for the treatment of tracheal collapse between January 2018 and July 2021 were examined and data on canine signalment, clinical signs, diagnostic test results, surgical outcomes, and postoperative complications were retrieved and analyzed statistically. Results: Twenty-six stents were surgically implanted, with 20 dogs (90.9%) receiving one stent and the remaining two (9.1%) receiving two or more stents. All dogs survived the procedure. The median survival time at a median follow-up of 990 days was 879 days. At the final follow-up examination, loss or mild improvement of cough was observed in all dogs. Conclusions: Compared with conventional lumen stents, the cross-and-hook braided Fauna Stent offered a higher survival rate and improved clinical symptoms in all patients. The results of this study suggest that the Fauna Stent may be a promising treatment option for dogs with tracheal collapse.

Comparison between Kissing Stents and Direct Surgical Bypass for Aortoiliac Occlusive Disease

  • Chung Won Lee;Up Huh;Miju Bae;Changsung Han;Hoon Kwon;Gwon-min Kim
    • Journal of Chest Surgery
    • /
    • v.56 no.4
    • /
    • pp.264-271
    • /
    • 2023
  • Background: The optimal management strategy for aortoiliac occlusive disease (AIOD) remains debatable. This study compared early and late outcomes between direct surgical bypass and kissing stents for AIOD treatment. Methods: We retrospectively reviewed data, including age, sex, risk factors, comorbidities, symptoms, TransAtlantic Inter-Society Consensus (TASC) II classification, operation time, perioperative complications, in-hospital mortality, and length of hospital stay, from a cohort of 46 patients treated for AIOD (24 with kissing stents and 22 with direct surgical bypass) at Pusan National University Hostpital from January 2007 to December 2016. The primary, assisted primary, and secondary patency rates in both groups were compared. Results: The hospital stay (direct surgical bypass vs. kissing stents: 16.36±5.19 days vs. 9.08±10.88 days, p=0.007) and operation time (direct surgical bypass vs. kissing stents: 316.09±141.78 minutes vs. 99.54±37.95 minutes, p<0.001) were significantly shorter for kissing stents. Kaplan-Meier analysis revealed that the primary, assisted primary, and secondary patency rates in the direct surgical bypass group were 95.5%, 95.5%, and 95.5%, respectively, at 1 year; 86.4%, 86.4%, and 95.5% at 3 years; and 77.3%, 77.3%, and 95.5% at 5 years. The primary, assisted primary, and secondary patency rates in the kissing stent group were 100.0%, 100.0%, and 100.0%, respectively, at 1 year; 95.8%, 95.8%, and 100.0% at 3 years; and 95.8%, 95.8%, and 100.0% at 5 years. Conclusion: Except for special cases wherein endovascular revascularization is difficult, kissing stents are more advantageous for TASC II C and D lesions.

Application of Two Different Tracheal Stents in Small Toy Dogs with Tracheal Collapse

  • Piao, Zhenglin;Kim, Young-Ung;Kang, Jin-Su;Lee, Dong-Bin;Heo, Su-Young;Kim, Nam-Soo
    • Journal of Veterinary Clinics
    • /
    • v.36 no.5
    • /
    • pp.248-252
    • /
    • 2019
  • Tracheal collapse is a common respiratory disease in dogs. There are many ways to treat tracheal collapse, one of which is the use of an intraluminal stent. In this study, we divided 21 dogs into two groups and implant conventional stents and new nitinol stents. Comparison of two groups was based on following, feature of stent fracture, form of stent migration, clinical sign improvement, complication and prognosis. Approaching was established via C-arm under spontaneous breathing and placing a stent at the site of collapse. Using radiographic images, determine stent size accurately. For a comparison of identical condition, all intraluminal stents were placed 10 mm caudal from larynx to 10 mm cranial from carina. In this study, new nitinol stents improve the problems of conventional stents and may be effective in the treatment of tracheal collapse in small dogs.

Influence of biliary stents on the diagnostic outcome of endoscopic ultrasound-guided tissue acquisition from solid pancreatic lesions: a systematic review and meta-analysis

  • Suprabhat Giri;Shivaraj Afzalpurkar;Sumaswi Angadi;Jijo Varghese;Sridhar Sundaram
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.169-179
    • /
    • 2023
  • Background/Aims: This meta-analysis analyzed the effect of an indwelling biliary stent on endoscopic ultrasound (EUS)-guided tissue acquisition from pancreatic lesions. Methods: A literature search was performed to identify studies published between 2000 and July 2022 comparing the diagnostic outcomes of EUS-tissue acquisition (TA) in patients with or without biliary stents. For non-strict criteria, samples reported as malignant or suspicious for malignancy were included, whereas for strict criteria, only samples reported as malignant were included in the analysis. Results: Nine studies were included in this analysis. The odds of an accurate diagnosis were significantly lower in patients with indwelling stents using both non-strict (odds ratio [OR], 0.68; 95% confidence interval [CI], 0.52-0.90) and strict criteria (OR, 0.58; 95% CI, 0.46-0.74). The pooled sensitivity with and without stents were similar (87% vs. 91%) using non-strict criteria. However, patients with stents had a lower pooled sensitivity (79% vs. 88%) when using strict criteria. The sample inadequacy rate was comparable between groups (OR, 1.12; 95% CI, 0.76-1.65). The diagnostic accuracy and sample inadequacy were comparable between plastic and metal biliary stents. Conclusions: The presence of a biliary stent may negatively affect the diagnostic outcome of EUS-TA for pancreatic lesions.

Clinical and Angiographic Outcomes of Endovascular Treatment for Acute Intracranial Vertebral Artery Dissecting Aneurysms Using Double-Overlapping Stents : Low-Profile Visualized Intraluminal Support within Enterprise Stents

  • Ja Ho Koo;Eui Hyun Hwang;Ji Hye Song;Yong Cheol Lim
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.5
    • /
    • pp.531-540
    • /
    • 2024
  • Objective : The use of reconstructive treatment with a double-overlapping stents has proven to be effective and safe in the current treatment of intracranial vertebral artery dissecting aneurysms (VADAs). We employed a combination of overlapping stents, using low-profile visualized intraluminal support (LVIS) within the Enterprise stent. This combination was chosen to minimize the outward bulging of the inner LVIS by overlapping it with the Enterprise stent while maintaining flow diversion and stability. This study aimed to evaluate the clinical and angiographic outcomes following the use of double-overlapping stents with LVIS within the Enterprise stent for the treatment of VADAs. Methods : From March 2016 to January 2022, total 28 patients with unruptured VADAs were treated with the double-overlapping stent technique using LVIS within an Enterprise stent in our institute. The Enterprise stent was deployed first, followed by the LVIS stent. Patient clinical and angiographic characteristics, procedural complications, and follow-up outcomes were retrospectively reviewed. Results : All 28 patients (18 males and 10 females) were successfully treated with double-overlapping stent deployment. There were no procedural complications or new neurological deficits in any patient. Of the 28 patients, four VADAs had posterior inferior cerebellar artery involvement. Procedure-related parent artery occlusion did not occur during the angiographic follow-up conducted 6 to 12 months after the procedure. Out of 28 patients, 24 showed complete healing, three had focal residual stenosis or dilatation with residual sac and only one had a residual dissecting flap with aneurysm. All patients, including the four patients, did not require any additional procedures. The postoperative modified Rankin scale scores were 0-1 for all patients. Conclusion : A double-overlapping stent, with a flow-diversion effect, is a safe and effective treatment for patients with VADAs. In particular, when using the LVIS stent within an Enterprise stent, it minimizes the bulging of the inner LVIS stent while maintaining flow diversion and stability. Therefore, both can be effectively utilized as overlapping stents.