Various Techniques of Stent-Assisted Coil Embolization of Wide-Necked or Fusiform Middle Cerebral Artery Aneurysms : Initial and Mid-Term Results

  • Won, Yu Sam;Rho, Myung Ho;Kim, Byung Moon;Park, Hee Jin;Kwag, Hyon Ju;Chung, Eun Chul
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권5호
    • /
    • pp.274-280
    • /
    • 2013
  • Objective : To evaluate the feasibility and clinical and angiographic outcomes of stent-assisted embolization for complex middle cerebral artery (MCA) aneurysms. Methods : The records of 23 consecutive patients with 24 MCA aneurysms, who underwent stent-assisted embolization of the aneurysm, were retrospectively evaluated. Results : Fifteen aneurysms were treated with one stent and 8 were treated using more than two stents (5 a stent-within-a-stent, 1 triple stents, and two Y-stent). Angiographically, complete or near complete occlusion was achieved in 15 aneurysms (65.2%), residual neck in five (21.7%), and residual aneurysm in three (13.1%). Five aneurysms demonstrated thrombosis within the stent during the procedure and hospitalization, and were resolved by intraarterial and intravenous Tirofiban injection. Symptomatic thromboembolic complications were developed in five patients and permanent deficits demonstrated in two patients with modified Rankin Scale 1 and 2, respectively. Treatment-related permanent morbidity and mortality rates were 8.3% and 0% with relatively high complication rate. Angiographic follow-up was available in 17 aneurysms at 6-31 months (mean, 13.2 months) and showed stable or improved in 15 (88.2%) and major and minor recurrence in one, respectively. Conclusion : Complex MCA aneurysms could be treated by stent-assisted coiling and showed lower recanalization rate during mid-term follow-up by effective flow diversion due to various stent-assisted techniques. Our results warrant further study with a longer follow-up period in a larger sample.

Retrieval of a dislodged and dismounted coronary stent; using a rendezvous and snare technique at the brachial artery level via femoral approach

  • Jeong, Min-Woong;Sohn, Chang-Bae;Kim, Su Hong;Park, Jong-Ik;Park, Se-Ryeong;Min, Jun-Sik
    • Journal of Yeungnam Medical Science
    • /
    • 제33권2호
    • /
    • pp.138-141
    • /
    • 2016
  • Coronary stent dislodgement during percutaneous coronary intervention, which occurs when the stent is passed through tortuous and calcified lesions, is not a rare complication. Without proper treatment, such as fixing with another stent in the coronary artery or removing the undeployed stent from the coronary artery or systemic artery system, this complication can cause serious problems. We experienced the unusual situation of a dismounted and dislodged coronary stent, in which retrograde retrieval to the radial artery was impossible during transradial coronary intervention. We report on use of a rendezvous and snare technique at the brachial artery level via femoral puncture, which resulted in resolution without surgery.

하중 방향에 따른 관상동맥용 스텐트의 유연성 해석 (Flexibile Analysis of Coronary Stents due to Loading Directions)

  • 조승관;조은정;김한성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.331-334
    • /
    • 2004
  • In clinical use, coronary stents keep coronary arteries open after expansion with a balloon catheter and prevent the expanded artery from collapsing. Coronary stents are positioned in artery by catheter with a balloon along a guide wire to the lesion site. Flexibility is one of important ability for delivery. In this paper, Palmaz-Schatz stent and Tenax complete stent were selected because these are the most representative of tubular stents. Finite element analyses for the stent system were performed using ABAQUS/Standard code. The present study estimated the flexibility of coronary stents due to loading directions. Moreover the present paper suggests a numerical method to test the flexibility of stents. In conclusion this paper shows how the finite element analysis can be effectively organized in the stent development.

  • PDF

유한요소법을 이용한 스텐트의 기계적 성능 비교 및 평가 (Using Finite Element Analysis for Mechanical Properties of Coronary Stents)

  • 조승관;김한성;이상헌;탁계래;탁승제
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1306-1309
    • /
    • 2003
  • In the present paper, finite element analyses were carried out to evaluate the most important feature of a stent, that is. high radial strength and flexibility. Palmaz-Schatz 154 stent and two new models(stent A, stent B) were selected because they are the most representatives of tubular stents. Finite element analyses for the stent system were performed using ABAQUS/Explicit code. As a result, Palmaz-Schatz 154 stent shows sufficient radial strength but it needs some improvement in general properties such as high flexibility, low elastic recoil, low longitudinal contraction and low metal coverage area. Other two models show that sufficient flexibility, foreshortening and longitudinal recoil.

  • PDF

형상기억합금 트러스 구조물을 이용한 스텐트의 설계 및 해석 (Stent modeling and simulation of truss structure using SMA)

  • 양성필;김상헌;조맹효
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.518-522
    • /
    • 2008
  • Recently, many patients related to heart disease have surgical operation by expanding a blood vessel to treat the angiostenosis. So far most angioplasties have been performed using balloon-dilative stent made of stainless steel. Some researchers are studying the stent made of shape memory alloy (SMA) to operate the angioplasty more easily. and there are several papers which introduce the angioplasty using SMA. However, most of the analysis models for stents are constructed using solid elements. So much computing time is required to solve the analysis model. In this study, we suggest the SMA stent model using 1D truss element which is much faster than stent model using 3D solid element. To represent non-linear behavior of SMA, we apply 1D SMA constitutive equation of Lagoudas'. Pseudo-elastic behavior of stent structures is presented as a numerical example.

  • PDF

Novel Noncrossing Y-Stent Technique Using Tapered Proximal End of a Solitaire AB Stent for Coil Embolization of Wide-Neck Bifurcation Aneurysms

  • Kwon, Hyon-Jo;Lim, Jeong-Wook;Byoun, Hyoung Soo;Koh, Hyeon-Song
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권1호
    • /
    • pp.136-141
    • /
    • 2021
  • The crossing Y-stent method is one of the indispensable techniques to achieve sufficient neck coverage during coil embolization of bifurcation aneurysms with a wide neck and/or branch incorporation. However, the inevitable hourglass-like expansion of the second stent at the crossing point can result in insufficient vessel wall apposition, reduced aneurysm neck coverage, delayed endothelialization, and subsequent higher risks of acute or delayed thrombosis. It also interferes with engagement of the microcatheter into the aneurysm after stent installation. We expected to be able to reduce these disadvantages by installing a noncrossing type Y-stent using the Solitaire AB stent, which is fully retrievable with a tapered proximal end. Here we report the techniques and two successful cases.

자가팽창성 Stent-graft의 경관적 설치술을 이용한 대동맥류의 치료 -2 예 보고- (Endovascular Placement of Self-Expandable Stent-Graft for the Treatment of Aortic Aneurysms -2 cases-)

  • 신현우;이재성
    • Journal of Chest Surgery
    • /
    • 제33권1호
    • /
    • pp.99-102
    • /
    • 2000
  • The usual treatment for aortic aneurysms is surgical replacement with a prosthetic graft; however the associated morbidity and mortality rates must be considered. Endovascular placement of self-expandable stent-graft is a safe noninvasive treatment that can be an alternative to the surgical repair, the postoperative course of the 2 cases of thoracoabdominal aortic aneurysms was uneventful and no complication has been associated with the stent-graft during the 17 months and 5 months follow-up studies,.

  • PDF

정상유동에서 자가팽창성 그래프트 스텐트의 수력학적 특성 (Hydrodynamic Characteristics of Self-expandable Graft Stents in Steady Flow)

  • 이홍철;김철생;박복춘;박복춘
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권1호
    • /
    • pp.37-44
    • /
    • 2003
  • 본 실험연구에서는 정상유동상태에서 새롭게 설계된 자가팽창성 그래프트 스텐트의 수력학적 성능을 평가하고자 하였다. 코팅 재질이 다른 두 개의 그래프트 스텐트와 한 개의 타이티놀 금속스텐트가 실험에 사용되었으며, 유량이 가자 5, 10, 15 1/min에서 스텐트 전후에서의 압력변화 및 속도분포를 측정하였다. 스텐트 삽입에 의한 압력손실은 유량이 증가함에 지수적으로 증가하였다. 특히 15 1/min의 유량에서 다공성 PTFE 그래프트 스텐트와 TiNi 금속스텐트의 압력손실은 거의 동일하나 PU 그래프트 스텐트는 약 6배 이상의 현저한 증가를 보이고 있다. 스텐트 후류에서의 속도분포는 다공성 PTFE 그래프트 스텐트와 TiNi 금속스텐트는 유량에 관계없이 유사한 형태를 보여주고 있다. 그러나, PU 그래프트 스텐트에서는 특히 유량이 10 1/min 이상에서 속도분포가 비대칭적이고 관 중심에서의 상대적인 낮은 유속을 보여주고 있으며, 결과적으로 벽면전단응력 및 수직응력의 증가론 초래하고 있다. 이와같이 PU 그래프트 스텐트의 상대적으로 낮은 수력학적 성능은 스텐트가 보다 작은 관에 삽입되었을때 코팅재질의 낮은 유연성으로 인하여 스텐트의 표면에 주름이 발생하여 유동단면이 비대칭적으로 되고 벽면의 조도가 증가하며, 관벽과 스텐트와 틈새가 존재하여 제트류가 형성되기 때문으로 해석된다.

Inadvertent Self-Detachment of Solitaire AB Stent during the Mechanical Thrombectomy for Recanalization of Acute Ischemic Stroke : Lessons Learned from the Removal of Stent via Surgical Embolectomy

  • Kang, Dong-Hun;Park, Jaechan;Hwang, Yang-Ha;Kim, Yong-Sun
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권6호
    • /
    • pp.360-363
    • /
    • 2013
  • We recently experienced self-detachment of the Solitaire stent during mechanical thrombectomy of acute ischemic stroke. Then, we tried to remove the detached stent and to recanalize the occlusion, but failed with endovascular means. The following diffusion weighted image MRI revealed no significant increase in infarction size, therefore, we performed surgical removal of the stent to rescue the patient and to elucidate the reason why the self-detachment occurred. Based upon the operative findings, the stent grabbed the main thrombi but inadvertently detached at a severely tortuous, acutely angled, and circumferentially calcified segment of the internal carotid artery. Postoperative angiography demonstrated complete recanalization of the internal carotid artery. The patient's neurological deficits gradually improved, and the modified Rankin scale score was 2 at three months after surgery. In the retrospective case review, bone window images of the baseline computed tomography (CT) scan corresponded to the operative findings. According to this finding, we hypothesized that bone window images of a baseline CT scan can play a role in terms of anticipating difficult stent retrieval before the procedure.