• 제목/요약/키워드: stent

검색결과 669건 처리시간 0.026초

Waffle-Cone Technique Using Solitaire AB Stent

  • Park, Hye-Ran;Yoon, Seok-Mann;Shim, Jai-Joon;Kim, Sung-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권4호
    • /
    • pp.222-226
    • /
    • 2012
  • The waffle-cone technique is a modified stent application technique, which involves protrusion of the distal portion of a stent into an aneurysm fundus to provide neck support for subsequent coiling. The authors report two cases of wide necked basilar bifurcation aneurysms, which were not amenable to stent assisted coiling, that were treated using the waffle-cone technique with a Solitaire AB stent. A 58-year-old woman presented with severe headache. Brain CT showed subarachnoid hemorrhage and angiography demonstrated a ruptured giant basilar bifurcation aneurysm with broad neck, which was treated with a Solitaire AB stent and coils using the waffle-cone technique. The second case involved an 81-year-old man, who presented with dizziness caused by brain stem infarction. Angiography also demonstrated a large basilar bifurcation unruptured aneurysm with broad neck. Solitaire AB stent deployment using the waffle-cone technique, followed by coiling resulted in near complete obliteration of aneurysm. The waffle-cone technique with a Solitaire AB stent can be a useful alternative to conventional stent application when it is difficult to catheterize bilateral posterior cerebral arteries in patients with a wide-necked basilar bifurcation aneurysm.

유한요소 해석방법을 이용한 스텐트와 혈관, Plaque의 상호작용에 관한 연구 (Finite Element Analysis of Stent Expansion Considering Stent, Artery and Plaque Interaction)

  • 김성민;박성윤
    • 한국정밀공학회지
    • /
    • 제23권10호
    • /
    • pp.121-125
    • /
    • 2006
  • In this paper, results are presented by nonlinear finite element simulations in order to analy the interactions between the stent and artery or plaque. Maximum of von Mises stress was calculated in the contacting areas between the stent and the artery. The simulated results show that the distal end of stent, which tilts after expansion, may injure the artery wall. In conclusion, this study may help designing new stents.

In-Stent Stenosis of Stent-Assisted Coil Embolization of the Supraclinoid Internal Carotid Artery Aneurysm

  • Lee, Jae-Il;Ko, Jun-Kyeung;Choi, Byung-Kwan;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권6호
    • /
    • pp.370-373
    • /
    • 2012
  • The intracranial stent functions primarily to prevent protrusion of coils into the parent vessel during the embolization of wide-necked cerebral aneurysms and might also reduce aneurysm recanalization rate. In spite of these advantages, little is known about the long-term interaction of the stent with the parent vessel wall. We present a rare case of severe in-stent stenosis occurring as a delayed complication of Neuroform stent-assisted coil embolization of an unruptured intracranial aneurysm.

콘빔형 전산화단층영상을 이용한 치과임플란트 식립유도장치 개발 (Surgical stent for dental implant using cone beam CT images)

  • 최형수;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제40권4호
    • /
    • pp.171-178
    • /
    • 2010
  • Purpose : The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Materials and Methods : Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Results : Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. Conclusion : The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

Effectiveness and Technical Considerations of Solitaire Platinum 4×40 mm Stent Retriever in Mechanical Thrombectomy with Solumbra Technique

  • Yi, Ho Jun;Sung, Jae Hoon;Lee, Dong Hoon;Song, Seung Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권1호
    • /
    • pp.30-38
    • /
    • 2021
  • Objective : The Solitaire Platinum 4×40 mm stent retriever contains radiopaque markers with a long length. We evaluated the effect of Solitaire Platinum 4×40 mm stent retriever in Solumbra technique thrombectomy, and compared it with shorter Solitaire stent retrievers. Methods : A total of 70 patients who underwent Solumbra technique thrombectomy with equal diameter (4 mm) and different length (40 vs. 20 mm) Solitaire stent retrievers were divided into two groups : the Solitaire Platinum 4×40 mm stent (4×40) group and the Solitaire FR 4×20 mm stent or Solitaire Platinum 4×20 mm stent (4×20) group. The clinical outcomes, Thrombolysis in Cerebral Infarction score, the first pass reperfusion status, and complications were evaluated and compared between the two groups. Multivariate analysis was performed to evaluate the predictive factors for reperfusion and complete reperfusion from the first pass. Results : Higher first-pass reperfusion and complete reperfusion were achieved in the 4×40 group (68.0% and 48.0%) than in the 4×20 group (46.7% and 33.3%; p=0.004 and 0.007, respectively). In multivariate analysis, radiopaque device and longer stent retriever were correlated with first-pass reperfusion (p=0.014 and 0.008, respectively) and first-pass complete reperfusion (p=0.022 and 0.012, respectively). Conclusion : Our study demonstrated the usefulness of the Solitaire Platinum 4×40 mm stent retriever, which led to higher first-pass reperfusion and complete reperfusion rates than the Solitaire FR 4×20 mm stent or the Solitaire Platinum 4×20 mm stent, especially in Solumbra technique thrombectomy.

Effect of Stent Placement on Survival in Patients with Malignant Portal Vein Stenosis: A Propensity Score-Matched Study

  • Dong Jae Shim;Jong Woo Kim;Doyoung Kim;Gi-Young Ko;Dong Il Gwon;Ji Hoon Shin;Yun-Jung Yang
    • Korean Journal of Radiology
    • /
    • 제23권1호
    • /
    • pp.68-76
    • /
    • 2022
  • Objective: Percutaneous portal vein (PV) stent placement can be an effective treatment for symptoms associated with portal hypertension. This study aimed to evaluate the effect of PV stenting on the overall survival (OS) in patients with malignant PV stenosis. Materials and Methods: Two groups of patients with malignant PV stenosis were compared in this retrospective study involving two institutions. A total of 197 patients who underwent PV stenting between November 2016 and August 2019 were established as the stent group, whereas 29 patients with PV stenosis who were treated conservatively between July 2013 and October 2016 constituted the no-stent group. OS was compared between the two groups before and after propensity score matching (PSM). Risk factors associated with OS were evaluated using the Cox proportional hazards model. Procedure-associated adverse events were also evaluated. Results: The stent group finally included 100 patients (median age, 65 [interquartile range, 58-71] years; 64 male). The no-stent group included 22 patients (69 [61-75] years, 13 male). Stent placement was successful in 95% of attempted cases, and the 1- and 2-year stent occlusion-free survival rate was 56% (95% confidence interval, 45%-69%) and 44% (32%-60%), respectively. The median stent occlusion-free survival time was 176 (interquartile range, 70-440) days. OS was significantly longer in the stent group than in the no-stent group (median 294 vs. 87 days, p < 0.001 before PSM, p = 0.011 after PSM). The 1- and 3-year OS rates before PSM were 40% and 11%, respectively, in the stent group. The 1-year OS rate after PSM was 32% and 5% in the stent and no-stent groups, respectively. Anemia requiring transfusion (n = 2) and acute thrombosis necessitating re-stenting (n = 1) occurred in three patients in the stent group within 1 week. Conclusion: Percutaneous placement of a PV stent may be effective in improving OS in patients with malignant PV stenosis.

Bio-inspired leaf stent for direct treatment of cerebral aneurysms: design and finite element analysis

  • Zhou, Xiang;You, Zhong;Byrne, James M.D.
    • Smart Structures and Systems
    • /
    • 제8권1호
    • /
    • pp.1-15
    • /
    • 2011
  • Cerebral aneurysm is common lesion among adult population. Current methods for treating the disease have several limitations. Inspired by fern leaves, we have developed a new stent, called leaf stent, which can provide a tailored coverage at the neck of an aneurysm and thus prevent the blood from entering the aneurysm. It alone can be used to treat the cerebral aneurysm and therefore overcomes problems existing in current treating methods. The paper focuses on the numerical simulation of the leaf stents. The mechanical behaviour of the stent in various designs has been investigated using the finite element method. It has been found that certain designs provide adequate radial force and have excellent longitudinal flexibility. The performance of certain leaf stents is comparable and even superior to those of the commercially available cerebral stents such as the Neuroform stent and the Enterprise stent, commonly used for stent assisted coiling, while at the same time, providing sufficient coverage to isolate the aneurysm without using coils.

Experiences of Neuroform Stent Applications for Ruptured Anterior Communicating Artery Aneurysms with Small Parent Vessel

  • Yun, Jung-Ho;Cho, Chun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권1호
    • /
    • pp.53-58
    • /
    • 2010
  • Objective : The purpose of this study was to review the safety and durability of aneurysms treated with stent-assisted coiling of ruptured anterior communicating artery aneurysms with small parent vessels (< 2.0 mm). Methods : Retrospective review of all ruptured aneurysm treated with stent assisted endovascular coiling between March 2005 and March 2009 at our institution was conducted. We report 11 cases of the Neuroform stent placement into cerebral vessels measuring less than 2.0 mm in diameter (range, 1.3-1.9 mm) in anterior cerebral artery. Clinical follow-up ranged from 3 to 12 months and imaging follow-up was performed with cerebral angiography at 6 months and 12 months after discharge. Results : Complete occlusion was achieved in 10 patients, and a remnant neck was evident in one. No stent displacement or no dislodgement occurred during stent placement. There was no evidence of thromboembolic complication, arterial dissection and spasm during procedure. We performed follow-up angiography in all patients at 6 months and/or 12 months from the first procedure. The follow-up angiographic data showed successfully results except one in-stent stenosis case. All patients improved clinical performances except one patient with severe vasospasm who showed poor clinical condition initially. Conclusion : We have safely and successfully treated 11 vessels smaller than 2.0 mm in diameter with self-expanding stents with good short and intermediate term results. More clinical data with longer follow-ups are needed to establish the role of stent-assisted coiling in ruptured aneurysms with small parent vessels.

췌공장 스텐트의 공장으로의 이동으로 발생한 스텐트-돌 복합체 형성과 이로 인한 소장폐색: 증례 보고 (Migrated Pancreaticojejunal Stent Forming a Stent-Stone Complex in the Jejunum with Resultant Small Bowel Obstruction: A Case Report)

  • 김지원;김영한;이병희
    • 대한영상의학회지
    • /
    • 제84권2호
    • /
    • pp.512-517
    • /
    • 2023
  • 췌공장문합술 후 췌관 내 스텐트를 삽입하는 것은 수술 후에 췌장루나 췌관 협착의 발생을 예방하기 위해 널리 시행하는 술기이다. 그러나 삽입한 스텐트가 막히거나 이동하는 등 스텐트에 의해서도 다양한 합병증이 발생할 수 있다. 저자들은 췌관에 삽입한 플라스틱 스텐트가 이동하면서 발생된 매우 드문 합병증의 예를 보고하고자 한다. 유문부 보존 췌두부십이지장 절제술 시행 후 췌장 내 삽입한 스텐트는 공장으로 이동하여 스텐트-돌 복합체의 근원으로 작용하여 공장 폐색을 일으켰다. 스텐트-돌 복합체는 탐색적 개복술로 제거되었다.

여러 형상을 고려한 약물분출 스텐트의 성능에 대한 수치해석적 연구 (Performance of Various Drug-Eluting Stent Geometries Measured Using Computational Analysis)

  • 서태원
    • 대한기계학회논문집B
    • /
    • 제36권6호
    • /
    • pp.601-607
    • /
    • 2012
  • 본 연구는 내피세포 표면에 약물방출 스텐트에서 방출되는 약물의 농도와 약물분출 스텐트의 형상과 설계가 스텐트 주위 유동특성에 어떤 영향을 미치는지를 조사하기 위해 전산유체역학을 이용하여 연구를 수행하였다. 본 연구에서는 이상적으로 가정된 세 종류의 스텐트 모델과 임상결과를 거쳐 상용화되고 있는 세 종류의 스텐트 모델에 대하여 전산수치해석을 수행하였다. 본 연구의 목적은 스텐트의 성능을 정량적으로 평가할 수 있는 스텐트 영향 지수의 개념을 소개하고, 성능을 비교하는 것이다. 비교 결과, 연구된 세 종류의 상용 스텐트 모델 중 수치 모사에 적용된 모든 레이놀즈 수에 대하여 BX Velocity 스텐트의 스텐트 영향 지수가 가장 낮게 나타났다. 그러나 여섯 종류의 스텐트 모델 가운데에서는 전산 수치 모사에 적용된 모든 유동조건하에서 Spiral 스텐트의 스텐트 영향 지수가 가장 낮고 성능 역시 가장 좋은 것으로 나타났다.