• 제목/요약/키워드: steel-concrete structure

검색결과 1,123건 처리시간 0.024초

Finite Element Analysis of Chloride Ion Intrusion into Coastal Concrete Structure

  • Kim, Eun-Kyum;Shin, Chee-Bur;Yeau, Kyong-Yun
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.175-180
    • /
    • 1999
  • In order to predict the onset of the corrosion of steel bars in concrete, a mathematical model was presented to observe the diffusion of chloride ion in aqueous phase, the adsorption and desorption of chloride ions to and from the surface of solid phase of concrete, and the chemical reaction or chloride ions with solid phase. The finite element method was employed to carry out the numerical analysis. The chlorides enetrating through the wall of the concrete structure from the external environment and the chlorides contained in the concrete admixture were confirmed to be two important factors to determine the onset of the corrosion of steel bars.

  • PDF

Seismic experiment and analysis of rectangular bottom strengthened steel-concrete composite columns

  • Hui, Cun;Zhu, Yanzhi;Cao, Wanlin;Wang, Yuanqing
    • Steel and Composite Structures
    • /
    • 제20권3호
    • /
    • pp.599-621
    • /
    • 2016
  • In order to study the working mechanism of rectangular steel-concrete composite columns subjected to compression-bending load and further determine the seismic performance index, a bottom strengthened rectangular steel reinforced concrete (SRC) column with concealed steel plates and a bottom strengthened rectangular concrete filled steel tube (CFST) columns were proposed. Six column models with different configurations were tested under horizontal low cyclic loading. Based on the experiments, the load-bearing capacity, stiffness and degradation process, ductility, hysteretic energy dissipation capacity, and failure characteristics of the models were analyzed. The load-bearing capacity calculation formulas for a normal section and an oblique section of bottom strengthened rectangular steel-concrete composite columns were pesented and a finite element (FE) numerical simulation of the classical specimens was performed. The study shows that the load-bearing capacity, ductility, and seismic energy dissipation capacity of the bottom strengthened rectangular steel-concrete composite columns are significantly improved compared to the conventional rectangular steel-concrete composite columns and the results obtained from the calculation and the FE numerical simulation are in good agreement with those from the experiments. The rectangular steel-concrete composite column with bottom strengthened shows better seismic behavior and higher energy dissipation capacity under suitable constructional requirements and it can be applied to the structure design of high-rise buildings.

Shear lag effect in steel-concrete composite beam in hogging moment

  • Luo, Da;Zhang, Zhongwen;Li, Bing
    • Steel and Composite Structures
    • /
    • 제31권1호
    • /
    • pp.27-41
    • /
    • 2019
  • Shear lag effect can be an important phenomenon to consider in design of the steel-concrete composite beams. Researchers have found that the effect can be strongly related with the moment distribution, the stiffness and the ductility of the composite beams. For continuous composite beams expected to sustain hogging moment, the shear lag effect can be more distinct as cracking of the concrete slab reduces its shear stiffness. Despite its influences on behaviour of the steel-concrete composite beams, a method for calculating the shear lag effect in steel-concrete composite beams sustaining hogging moment is still not available. Shear lag effect in steel-concrete composite beams sustaining hogging moment is investigated in this paper. A method was proposed specifically for predicting the effect in the cracked part of the steel-concrete composite beam. The method is validated against available experimental data. At last, FE studies are conducted for steel-concrete composite beams with different design parameters, loading conditions and boundary conditions to further investigate the shear lag effect and compare with the proposed method.

원전 격납건물의 Steel Fiber 적용성 평가를 위한 지진취약도 분석 (Seismic Fragility Analysis for Steel Fiber Applicability Assessment for Containment Structure of Nuclear Power Plant)

  • 김민규;박준희;전영선;최인길
    • 한국전산구조공학회논문집
    • /
    • 제25권5호
    • /
    • pp.381-388
    • /
    • 2012
  • 본 연구에서는 Steel Fiber를 원전 격납건물에 적용하기 위한 적용성 평가를 위해서 Steel Fiber가 삽입된 격납건물에 대한 지진위험도 평가를 수행하였다. Steel Fiber를 콘크리트에 삽입함으로써 콘크리트의 구조적 성능에서 취약점인 인장성능을 향상시킬 수 있고, 압축강도 및 전단강도도 증가시킬 수 있는 장점이 있기 때문이다. 그러나 아직까지 원전 격납건물에 Steel Fiber를 적용하기 위한 노력은 진행되고 있지 않다. 재료적 우수성에도 불구하고 원전에 적용하기 위해서는 좀 더 많은 사용경험과 성능검증이 이루어져야 가능할 것이다. 따라서 본 연구에서는 원자력발전소 격납건물에 Steel Fiber를 사용하였을 경우, 격납건물의 지진안전성의 변화를 살펴보기 위하여 기존의 실험자료를 이용하여 취약도 평가를 수행하였다. 분석결과 Steel Fiber의 함유로 인하여 전단성능과 연성능력이 증가하여 지진취약도의 향상으로 나타났다. Steel Fiber함유량이 1.0%인 경우 지진내력이 10%가량 증가하는 효과를 얻을 수 있었다. 그러나 본 연구의 결과는 제한된 기존의 실험결과를 이용한 예비해석이므로 Steel Fiber의 실제 적용성을 적확하게 분석하기 위해서는 Steel Fiber가 함유된 다양한 콘크리트 부재실험을 통하여 그 물성의 변화를 파악하여야 할 것이다.

보수 보강 부재의 단부 부착력 개선을 위한 피로실험 연구 (A Study on the Fatigue to Improve the End Bond Properties of Repair and Strengthening Member)

  • 한만엽;이영헌;김동욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.703-708
    • /
    • 1999
  • The concrete structure under fatigue load depresses in mechanical capability or breaks down finally because of the fatigue. So recently the study on strengthening methods using bonded steel plate is widely attended. Which could be constructed under use and without damaging the structure. The intention of this method is to increase the useability of the structure and to recover the strength. So application on fields are sharply increasing. In this study it is tried to develop strengthening methods using notches and anchor bolts which could supply the defect on falling off of the steel plate at the end.

  • PDF

초기재령 강섬유보강 철근콘크리트 보의 구조성능 평가 및 개선 (Improvement and Evaluation of Structural Performance of Steel Fiber Reinforced Concrete Beams Using Early Age Concrete)

  • 하기주;신종학;곽윤근;권칠성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.129-137
    • /
    • 1999
  • Reinforced concrete structures using early age concrete were result in the degradation of structural performance due to crack, overload, unexpected vibration and impact load. It demands urgently that reinforced concrete structure using early age concrete should be improved the serviceability and structural performance with the application of new fiber materials. Therefore specimens, designed by the test varibles, such as with or without stirrup and percent of steel fiber incorporated, were constructed and tested to evaluate and develop the structural performance of reinforced steel fiber concrete beam. Based on the test results reported in this study, the following conclusions are made. Specimens, designed by the over 0.75% of steel fiber incorporated, were showed the ductile behavior and failed slowly with flexure and flexure-shear. Comparing with the load-displacement relationship of specimen BSS, designed by the recommendations of the Ministry of Construction and Transportation, reinforced steel fiber concrete beam using early age concrete, over 0.75% of steel fiber incorporated, gets enough load carrying capacity and ductility. Increasing the percent of steel fiber incorporated(0.25~2.0%), the ultimate shear stress of each specimen were increased 12~40% than that of control specimen SSS.

  • PDF

XFINAS 계면요소와 고체요소를 이용한 콘크리트-강재 합성구조물의 비선형 거동해석 (Nonlinear Analysis of Steel-Concrete Composite Structures using XFINAS Interface and Solid Elements)

  • 김기두;수타스트라디트 송삭;박종화;박재균
    • 한국전산구조공학회논문집
    • /
    • 제23권3호
    • /
    • pp.267-274
    • /
    • 2010
  • 합성구조는 전체가 동일한 재료 특성을 가지는 구조와는 달리 서로 다른 특성 즉 강재와 콘크리트의 구조로 결합되어 있다. 따라서 실제 모델링 시 이러한 재료 특성을 반영하지 않으면 실제 거동을 예측할 수 없으므로 콘크리트와 강재 사이에 인터페이스 요소를 연결하여 강재와 콘크리트의 슬립을 예측할 수 있게 한다. 인터페이스 요소는 일반적으로 사용되는 구성방정식은 적합하지 않고 실제 부착 및 슬립을 고려한 비선형 구성 방정식을 사용하여야만 적절히 사용할 수 있다. 이 계면요소를 이용하여 판형 강재 박스와 콘크리트의 접촉면을 묘사하였다. 그리고 강재 박스의 휨-좌굴 거동을 묘사하기 위해서는 일반적인 8절점 적합 요소의 사용은 부적절하므로 판형 강재 박스는 보강 변형도(Enhanced Assumed Strain) 고체요소를 사용하여 휨거동을 묘사할 수 있게 하였다.

Seismic behaviors of ring beams joints of steel tube-reinforced concrete column structure

  • Zhang, Yingying;Pei, Jianing;Huang, Yuan;Lei, Ke;Song, Jie;Zhang, Qilin
    • Steel and Composite Structures
    • /
    • 제27권4호
    • /
    • pp.417-426
    • /
    • 2018
  • This paper presents the seismic behaviors and restoring force model of ring beam joints of steel tube-reinforced concrete column structure under cyclic loading. First, the main failure mode, ultimate bearing capacity, stiffness degradation and energy dissipation capacity are studied. Then, the effects of concrete grade, steel grade, reinforcement ratio and radius-to-width ratios are discussed. Finally, the restoring force model is proposed. Results show that the ring beam joints of steel tube-reinforced concrete column structure performs good seismic performances. With concrete grade increasing, the ultimate bearing capacity and energy dissipation capacity increase, while the stiffness degradation rates increases slightly. When the radius-width ratio is 2, with reinforcement ratio increasing, the ultimate bearing capacity decreases. However, when the radius-to-width ratios are 3, with reinforcement ratio increasing, the ultimate bearing capacity increases. With radius-to-width ratios increasing, the ultimate bearing capacity decreases slightly and the stiffness degradation rate increases, but the energy dissipation capacity increases slightly.

콘크리트 구조물의 전단 안정성 평가를 위한 전단전달 실험 및 해석 (An Experimental and Analytical Study on Shear Transfer for Safety Evaluation of Concrete Structure)

  • 김광수
    • 한국안전학회지
    • /
    • 제23권3호
    • /
    • pp.42-50
    • /
    • 2008
  • This study, push-off tests for the initially uncracked specimens were conducted to investigate shear transfer mechanism in reinforce concrete elements. Experimental programs for shear transfer were undertaken to investigate the effect of the concrete compressive strength, the presence of steel stirrups as shear reinforcement and the amount of steel stirrups. As the shear plane is loaded, several cracks form in a direction inclined to the shear plane, creating compression struts in the concrete. For this stage, shear is being transferred through a truss-like action produced by the combination of the compressive force in the concrete struts and the tensile force that the steel reinforcement crossing the shear plane develops. In the normal strength concrete specimens with steel stirrups, ultimate failure occurred when the compression struts crushed in concrete. In the high strength concrete specimens, on the other hand, ultimate failure occurred when the steel stirrups developed their yield strength.

CFT 기둥용 초고강도 충전콘크리트에 관한 연구 (A Study on High Strength Concrete of Concrete Filled Steel Tube Column)

  • 정근호;임남기;이영도
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.127-132
    • /
    • 2004
  • CFT(Concrete Filled Steel Tube) is a structure of circular or squared of steel column filled with concrete. The steel tube holds the concrete inside and that makes this structure to perform superior features on stiffness, proof stress, transformation, fire resistance and construction itself. In this study, by over the 800kgf/$\textrm{cm}^2$ of high strength concrete for CFT column, research has been done on the basic property of matter such as fluidity, resistance on segregation, compressive strength, setting icons of the concrete filled in the steel tube under conditions of standard weather. Physical properties of concrete for CFT that Concrete with silica fume, fly ash of air entraining and high-range water reducing agent, that used to CFT column research purpose to find the most ideal composition, which is achieved by the investigation in the concrete's property of matter like ability of Slump, Slump Flow, Air content, Bleeding, and Settlement. For this study, experiments which are bused on obtained the result through physical test are practiced, with all of the experiment, specimens only for control are produced in each method of curing and analyzed to relations with core strength in mock-up test. In mock-up test, the research is studied compactability of concrete filled in tube and degree of hydration hysteresis, as a basic reference for applying to field of CFT column which is used over 800kgf/$\textrm{cm}^2$ high strength concrete.