• Title/Summary/Keyword: steel model

Search Result 4,477, Processing Time 0.033 seconds

Assessing the effect of inherent nonlinearities in the analysis and design of a low-rise base isolated steel building

  • Varnavaa, Varnavas;Komodromos, Petros
    • Earthquakes and Structures
    • /
    • v.5 no.5
    • /
    • pp.499-526
    • /
    • 2013
  • Seismic isolation is an effective method for the protection of buildings and their contents during strong earthquakes. This research work aims to assess the appropriateness of the linear and nonlinear models that can be used in the analysis of typical low-rise base isolated steel buildings, taking into account the inherent nonlinearities of the isolation system as well as the potential nonlinearities of the superstructure in case of strong ground motions. The accuracy of the linearization of the isolator properties according to Eurocode 8 is evaluated comparatively with the corresponding response that can be obtained through the nonlinear hysteretic Bouc-Wen constitutive model. The suitability of the linearized model in the determination of the size of the required seismic gap is assessed, under various earthquake intensities, considering relevant methods that are provided by building codes. Furthermore, the validity of the common assumption of elastic behavior for the superstructure is explored and the alteration of the structural response due to the inelastic deformations of the superstructure as a consequence of potential collision to the restraining moat wall is studied. The usage of a nonlinear model for the isolation system is found to be necessary in order to achieve a sufficiently accurate assessment of the structural response and a reliable estimation of the required width of the provided seismic gap. Moreover, the simulations reveal that the superstructure's inelasticity should be taken into account, especially if the response of the structure under high magnitude earthquakes is investigated. The consideration of the inelasticity of the superstructure is also recommended in studies of structural collision of seismically isolated structures to the surrounding moat wall, since it affects the response.

A Study on the Dynamic Response of Highway Bridges by 4-Axles Single Truck (4축 단일차량에 의한 도로교의 동적응답에 관한 연구)

  • Chung, Tae-Ju
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.3
    • /
    • pp.397-404
    • /
    • 2011
  • In this paper, a research for the dynamic wheel loads of a 3D vehicle model, which relates to a tire-enveloping model, is carried out. A single truck with four axles is modeled as a 10-D.O.F. vehicle by modeling both contact length of tires and pitching of tandem spring axles. The dynamic equations of the vehicle are obtained using the Lagrange's equation, the solution of the equations is calculated by Newmark-${\beta}$ method. The validity of the developed 3D vehicle model is demonstrated by comparing results obtained from the proposed method with those from experimental data. The maximum impact factors of tire force are evaluated according to the various step bumps on which a 24-ton dump truck is running.

Application of Electromagnetic Wave for Evaluating Necking Defects in Bored Piles (현장타설말뚝의 네킹 결함 평가를 위한 전자기파의 적용성 연구)

  • Lee, Jong-Sub;Song, Jung Wook;Yu, Jung-Doung
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.4
    • /
    • pp.27-35
    • /
    • 2018
  • The objective of this study is to demonstrate the suitability of electromagnetic waves for evaluating necking defects in bored piles using electromagnetic waves. Experiments are conducted with small-scaled defective model pile with diameter of 150 mm and length of 270 mm. Two necking defects are generated at the upper and lower positions on two different sides of the model pile, respectively. The other two necking defects are generated at the upper and lower positions on the same side of the model pile. Electrical wires are installed alongside the stainless steel wire of a steel cage to configure a two-conductor transmission line. A time-domain reflectometer is used to generate and defect electromagnetic waves. The experimental results show that electromagnetic waves are reflected at the necking defects and the end of the model pile. In addition, calculated defect locations are almost the same as actual defect locations. This study demonstrates that electromagnetic waves can be effective tool for evaluating necking defects in bored piles.

Model Design and Demonstration Test for the Verification of Temperature Reduction Effect of Cooling Fog System with Stainless Steel (스테인리스 쿨링포그의 온도저감효과 검증을 위한 모델설계 및 실증 실험)

  • Kim, Jaekyoung;Kang, Junsuk;Kim, Hoijin
    • Journal of Environmental Science International
    • /
    • v.29 no.6
    • /
    • pp.683-689
    • /
    • 2020
  • According to a NASA Goddard Institute for Space Studies report, temperatures have risen by approximately 1℃ so far, based on temperatures recorded in 1880. The 2003 heatwave in Europe affected approximately 35,000 people across Europe. In this study, a cooling fog, which is used in smart cities, was designed to efficiently reduce the temperature during a heatwave and its pilot test results were interpreted. A model experiment of the cooling fog was conducted using a chamber, in which nano mist spray instruments and spray nozzles were installed. The designed cooling fog chamber model showed a temperature reduction of up to 13.8℃ for artificial pavement and up to 8.0℃ for green surfaces. However, this model was limited by constant wind speed in the experiment. Moreover, if the cooling fog is used when the wind speed is more than 3m/s in the active green zone, the temperature reduction felt by humans is expected to be even greater. As a second study, the effect of cooling fog on temperature reduction was analyzed by installing a pilot test inside the Land Housing Institute (LHI). The data gathered in this research can be useful for the study of heat reduction techniques in urban areas.

A Study on Thermal Ratcheting Structure Test of 316L Test Cylinder (316L 시험원통의 열라체팅 구조시험에 관한 연구)

  • Lee, H.Y.;Kim, J.B.;Koo, G.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.243-249
    • /
    • 2001
  • In this study, the progressive inelastic deformation, so called, thermal ratchet phenomenon which can occur in high temperature liquid metal reactor was simulated with thermal ratchet structural test facility and 316L stainless steel test cylinder. The inelastic deformation of the reactor baffle cylinder can occur due to the moving temperature distribution along the axial direction as the hot free surface moves up and down under the cyclic heat-up and cool-down of reactor operations. The ratchet deformations were measured with the laser displacement sensor and LVDTs after cooling the structural specimen which experiences thermal load up to $550^{\circ}$ and the temperature differences of about $500^{\circ}C$. During structural thermal ratchet test, the temperature distribution of the test cylinder along the axial direction was measured from 28 channels of thermocouples and the temperatures were used for the ratchet analysis. The thermal ratchet deformation analysis was performed with the NONSTA code whose constitutive model is nonlinear combined kinematic and isotropic hardening model and the test results were compared with those of the analysis. Thermal ratchet test was carried out with respect to 9 cycles of thermal loading and the maximum residual displacements were measured to be 1.8mm. It was shown that thermal ratchet load can cause a progressive deformation to the reactor structure. The analysis results with the combined hardening model were in reasonable agreement with those of the tests.

  • PDF

Numerical Analysis Method of Overlay Model for Material Nonlinearity Considering Strain Hardening (변형률 경화를 고려한 오버레이 모델의 재료비선형 수치해석기법)

  • Baek, Ki Youl
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.3
    • /
    • pp.291-301
    • /
    • 2007
  • The overlay model is a certain kinds of numerical analysis method to present the material non-lineariy which is represented the baushinger effect and the strain hardening. This model simulates the complex behavior of material by controlling the properties of the layers which like the hardening ratio, the section area and the yield stress. In this paper, the constitutive equation and plastic flow rule of each layer which are laid in the plane stress field are obtained by using the thermodynamics. Two numerical examples were tested for the validity of proposed method in uniaxial stress and plane stress field with comparable experimental results. The only parameter for the test is the yield stress distribution of each layers.

Fatigue Crack Growth of Welded-Structural Steel under Simple-Variable Loading (단순변동하중(單純變動荷重)을 받는 용접구조용강(鎔接構造用鋼)의 피로균열성장(疲勞龜裂成長))

  • Chang, Dong Il;Bak, Yong Gul;Lee, Bong Hak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.4
    • /
    • pp.103-113
    • /
    • 1987
  • Fatigue tests using a single-peak loading and a two-step loading were carried out to examine the fatigue crack growth behaviar and to find the appropriate analysis method. C-T specimens were made using structural steel SWS58 for the tests. From this, just after a single-peak loading acceleration effect was occured and after some times retardation effect was found. And eminent retardation effect was found after High-Low two-step loading. The transition effect of crack growth due to this variable loading was occured owing to the residual stress and the plastic zone size at the crack tip. And the behaviors of these are well explained by Elber's Crack Closure Model. Also I could find that the Wheeler's Retardation Model is a simple and appropriate theory among analysis methods of fatigue crack growth under the variable loading.

  • PDF

Scale model experimental of a prestressed concrete wind turbine tower

  • Ma, Hongwang;Zhang, Dongdong;Ma, Ze;Ma, Qi
    • Wind and Structures
    • /
    • v.21 no.3
    • /
    • pp.353-367
    • /
    • 2015
  • As concrete wind-turbine towers are increasingly being used in wind-farm construction, there is a growing need to understand the behavior of concrete wind-turbine towers. In particular, experimental evaluations of concrete wind-turbine towers are necessary to demonstrate the dynamic characteristics and load-carrying capacity of such towers. This paper describes a model test of a prestressed concrete wind-turbine tower that examines the dynamic characteristics and load-carrying performance of the tower. Additionally, a numerical model is presented and used to verify the design approach. The test results indicate that the first natural frequency of the prestressed concrete wind turbine tower is 0.395 Hz which lies between frequencies 1P and 3P (0.25-0.51 Hz). The damper ratio is 3.3%. The maximum concrete compression stresses are less than the concrete design compression strength, the maximum tensile stresses are less than zero and the prestressed strand stresses are less than the design strength under both the serviceability and ultimate limit state loads. The maximum displacement of the tower top are 331 mm and 648 mm for the serviceability limit state and ultimate limit state, respectively, which is less than L/100 = 1000 mm. Compared with traditional tall wind-turbine steel towers, the prestressed concrete tower has better material damping properties, potential lower maintenance cost, and lower construction costs. Thus, the prestressed concrete wind-turbine tower could be an innovative engineering solution for multi-megawatt wind turbine towers, in particular those that are taller than 100 m.

An Analytical Study on System Identification of Steel Beam Structure for Buildings based on Modified Genetic Algorithm (변형 유전 알고리즘을 이용한 건물 철골 보 구조물의 시스템 식별에 관한 해석적 연구)

  • Oh, Byung-Kwan;Choi, Se-Woon;Kim, Yousok;Cho, Tong-Jun;Park, Hyo-Seon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.4
    • /
    • pp.231-238
    • /
    • 2014
  • In the buildings, the systems of structures are influenced by the gravity load changes due to room alteration or construction stage. This paper proposes a system identification method establishing mass as well as stiffness to parameters in model updating process considering mass change in the buildings. In this proposed method, modified genetic algorithm, which is optimization technique, is applied to search those parameters while minimizing the difference of dynamic characteristics between measurement and FE model. To search more global solution, the proposed modified genetic algorithm searches in the wider search space. It is verified that the proposed method identifies the system of structure appropriately through the analytical study on a steel beam structure in the building. The comparison for performance of modified genetic algorithm and existing simple genetic algorithm is carried out. Furthermore, the existing model updating method neglecting mass change is performed to compare with the proposed method.

A Study on the Vertical Bearing Capacity of Batter Piles Subjected to Vertical Load (연직하중을 받는 경사말뚝의 연직지지력에 관한 연구)

  • 성인출;이민희;최용규;권오균
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.49-55
    • /
    • 2003
  • In this study, based on the relationship of the vertical force - settlement of batter piles obtained by pressure chamber model tests, the vertical bearing capacity of vertical and batter piles according to the increase of pile inclination was analyzed. A model open - ended steel pipe pile with the inclination of 5$^\circ$, 10$^\circ$ and 15$^\circ$ was driven into saturated fine sand with relative density of 50 %, and the static compression load tests were performed under each confining pressure of 35, 70 and 120 kPa in pressure chamber. The vertical bearing capacity of pile obtained from pressure chamber tests increased with the pile inclination. In the case of the inclination of 5$^\circ$, 10$^\circ$, 15$^\circ$, increasing ratios of pile bearing capacity were 111, 121, 127 ~ 140 % of vertical bearing capacity respectively. In the case of the inclination of above 20$^\circ$, the model tests could not be performed because of pile of pile head during compressive loading on the pile head.