• 제목/요약/키워드: steel liquid storage tanks

검색결과 15건 처리시간 0.022초

지진하중을 받는 정사각형 강재 액체저장탱크의 벽면 압력 응답 해석 (Earthquake-Induced Wall Pressure Response Analysis of a Square Steel Liquid Storage Tank)

  • 윤장혁;강태원;양현익;전종수
    • 한국지진공학회논문집
    • /
    • 제22권5호
    • /
    • pp.261-269
    • /
    • 2018
  • This study examines earthquake-induced sloshing effects on liquid storage tanks using computation fluid dynamics. To achieve this goal, this study selects an existing square steel tank tested by Seismic Simulation Test Center at Pusan National University as a case study. The model validation was firstly performed through the comparison of shaking table test data and simulated results for the water tank subjected to a harmonic excitation. For a realistic estimation of the wall pressure response of the water tank, three recorded earthquakes with similar peak ground acceleration are applied:1940 El Centro earthquake, 2016 Gyeongju earthquake, and 2017 Pohang earthquake. Wall pressures monitored during the dynamic analyses are examined and compared for different earthquake motions and monitoring points, using power spectrum density. Finally, the maximum dynamic pressure for three earthquakes is compared with the design pressure calculated from a seismic design code. Results indicated that the maximum pressure from the El Centro earthquake exceeds the design pressure although its peak ground acceleration is less than 0.4 g, which is the design acceleration. On the other hand, the maximum pressure due to two Korean earthquakes does not reach the design pressure. Thus, engineers should not consider only the peak ground acceleration when determining the design pressure of water tanks.

부식과 악취가스 대기확산 방지를 위한 액비저장조 밀폐형 지붕모델 개발 (Development of a Closed Roof Model for Liquid Manure Storage Tanks to Prevent Corrosion and Atmospheric Diffusion of Oder Gases)

  • 윤남규;이성현;김경원;염성현
    • 한국축산시설환경학회지
    • /
    • 제14권1호
    • /
    • pp.61-68
    • /
    • 2008
  • 악취가스의 대기확산을 방지하고, 액비의 발효를 위한 폭기장치의 가동을 정상화하여 액비저장조의 활용도를 높이고, 내식성 자재를 사용하여 구조적 안전성을 개선하기 위한 목적으로 액비저장조 밀폐형 지붕구조 모델을 개발하였으며, 결과를 요약하면 다음과 같다. 1. 액비저장조 및 지붕구조의 이용실태 조사결과, 악취가스의 발생으로 인한 민원 때문에 폭기장치 가동을 중단하고 있거나 특정시기에 한해 가동하는 농가가 대부분이었으며, 일반구조용 아연도금강관을 사용한 지붕 구조재의 부식이 다른 시설보다 빠르게 진행되고 있음을 확인하였다. 2. 구조자재의 강도시험 결과, 5년 동안 사용한 밀폐형 지붕 구조재의 경우 초기 강도의 34%까지 강도가 감소되는 등 부식에 의한 구조물의 강도저하가 심각하였으며, 내식성자재로 선발된 스테인리스(STS439)강의 경우 일반구조용강에 비해 1.4배 높은 강도를 나타내었다. 3. 직경 9.5m인 원형 액비저장조에 대하여 기존의 자재를 사용한 지붕모델과 내식성 자재를 사용한 지붕모델에 대하여 적설에 대한 구조안전성 분석 결과, 기존 자재를 사용한 경우에 비해 동일한 단면크기를 갖는 내식성 자재를 사용한 경우 적설에 대한 안전성이 약 2.3배까지 향상된 것으로 나타났다. 이상과 같이 본 연구에서 개발된 액비저장조 지붕모델은 밀폐형이므로 폭기시 발생하는 악취가스가 대기중으로 확산되지 않으며, 그 골조를 내식성이 우수한 스테인리스강, 아연용융도금강, FRP수지피복강을 사용하여 내구년한을 증가시킴으로써 구조적 안정성이 크게 향상되었다. 단, 금속재료의 부식에 대한 문제는 좀 더 장기간의 관찰과 실험을 통해 액비저장조 및 축산시설 고유의 부식속도를 구명하는 연구가 필요한 것으로 판단된다.

  • PDF

Analysis and prediction of ultimate strength of high-strength SFRC plates under in-plane and transverse loads

  • Perumal, Ramadoss;Palanivel, S.
    • Structural Engineering and Mechanics
    • /
    • 제52권6호
    • /
    • pp.1273-1287
    • /
    • 2014
  • Plates are most widely used in the hulls of floating concrete structures, bridge decks, walls of off-shore structures and liquid storage tanks. A method of analysis is presented for the determination of load-deflection response and ultimate strength of high-strength steel fiber reinforced concrete (HSSFRC) plates simply supported on all four edges and subjected to combined action of external compressive in-plane and transverse loads. The behavior of HSSFRC plate specimens subjected to combined uniaxial in-plane and transverse loads was investigated. The proposed analytical method is compared to the physical test results, and shows good agreement. To predict the constitutive behavior of HSSFRC in compression, a non-dimensional characteristic equation was proposed and found to give reasonable accuracy.

Behavior of high-strength fiber reinforced concrete plates under in-plane and transverse loads

  • Ramadoss, P.;Nagamani, K.
    • Structural Engineering and Mechanics
    • /
    • 제31권4호
    • /
    • pp.371-382
    • /
    • 2009
  • The concrete plates are most widely used structural elements in the hulls of floating concrete structures such as concrete barges and pontoons, bridge decks, basement floors and liquid storage tanks. The study on the behavior of high-strength fiber reinforced concrete (HSFRC) plates was carried out to evaluate the performance of plates under in-plane and transverse loads. The plates were tested in simply supported along all the four edges and subjected to in-plane and traverse loads. In this experimental program, twenty four 150 mm diameter cylinders and twelve plate elements of size $600{\times}600{\times}30$ mm were prepared and tested. Water-to-cementitious materials ratios of 0.3 and 0.4 with 10% and 15% silica fume replacements were used in the concrete mixes. The fiber volume fractions, $V_f$ = 0%, 1% and 1.5% with an aspect ratio of 80 were used in this study. The HSFRC mixes had the concrete compressive strengths in the range of 52.5 to 70 MPa, flexural strengths ranging from 6.21 to 11.08 MPa and static modulus of elasticity ranging from 29.68 to 36.79 GPa. In this study, the behavior of HSFRC plate elements subjected to combined uniaxial in-plane and transverse loads was investigated.

LNG 저장탱크 바닥판 단열 시스템 개선 (Improvement of Insulation System for LNG Storage Tank Base Slab)

  • 이용진;노병철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권4호
    • /
    • pp.141-147
    • /
    • 2010
  • LNG 천연가스로서 저장과 운반이 용이한 액체로 변형이 가능하며, 청정연료로 각광받게 되어, 석유에너지의 의존도를 낮추고 에너지사용의 다변화를 위해 1986년 인도네시아로부터 처음 도입된 이래로 산업의 성장과 더불어 그 수요량이 지속적으로 증가하고 있다. LNG는 천연가스의 부피를 영하 약 $-162^{\circ}C(-260^{\circ}F)$까지 냉각시켜 1/600까지 줄일 수 있으므로, 저장 및 운반에 있어서 매우 효율적이다. 현대의 LNG 저장탱크는 철근 콘크리트 이중벽과 내부 니켈방호벽 및 벽사이의 효율이 높은 단열재로 구성된 완전 방호식이 적용되고 있다. 단열재는 극저온의 온도가 LNG 탱크 외벽으로 전달되는 것을 차단하며, 바닥슬래브, 외벽 및 상부에 설치된다. LNG 저장탱크의 단열재의 배치에 따라 콘크리트 외조에 작용하는 온도분포에 차이가 나므로, 본 연구에서는 기 건설된 완전 방호식 LNG 저장탱크 바닥판 단열재의 배치에 대해 검토하고, 이를 바탕으로 단열시스템 개선 방안을 제안하고자 한다.