• 제목/요약/키워드: steel coupling beams

검색결과 53건 처리시간 0.024초

Seismic behavior of strengthened reinforced concrete coupling beams by bolted steel plates, Part 1: Experimental study

  • Zhu, Y.;Su, R.K.L.;Zhou, F.L.
    • Structural Engineering and Mechanics
    • /
    • 제27권2호
    • /
    • pp.149-172
    • /
    • 2007
  • An experimental study of five full-scale coupling beam specimens has been conducted to investigate the seismic behavior of strengthened RC coupling beams by bolted side steel plates using a reversed cyclic loading procedure. The strengthened coupling beams are fabricated with different plate thicknesses and shear connector arrangements to study their respective effects on load-carrying capacity, strength retention, stiffness degradation, deformation capacity, and energy dissipation ability. The study revealed that putting shear connectors along the span of coupling beams produces no significant improvement to the structural performance of the strengthened beams. Translational and rotational partial interactions of the shear connectors that would weaken the load-carrying capacity of the steel plates were observed and measured. The hierarchy of failure of concrete, steel plates, and shear connectors was identified. Furthermore, detailed effects of plate buckling and various arrangements of shear connectors on the post-peak behavior of the strengthened beams are discussed.

Behavior of strengthened reinforced concrete coupling beams by bolted steel plates, Part 2: Evaluation of theoretical strength

  • Zhu, Y.;Su, R.K.L.
    • Structural Engineering and Mechanics
    • /
    • 제34권5호
    • /
    • pp.563-580
    • /
    • 2010
  • Composite beams using bolts to attach steel plates to the side faces of existing reinforced concrete (RC) coupling beams can enhance both their strength and deformability. The behavior of those composite beams differs substantially from the behavior of typical composite beams made up of steel beams and concrete slabs. The former are subjected to longitudinal, vertical and rotational slips, while the latter only involve longitudinal slip. In this study, a mixed analysis method was adopted to develop the fundamental equations for accurate prediction of the load-carrying capacity of steel plate strengthened RC coupling beams. Then, a rigid plastic analysis technique was used to cope with the full composite effect of the bolt group connections. Two theoretical models for the determination of the strength of medium-length plate strengthened coupling beams based on mixed analysis and rigid plastic methods are presented. The strength of the strengthened coupling beams is derived. The vertical and longitudinal slips of the steel plates and the shear strength of the anchor-bolt connection group is considered. The theoretical models are validated by the available experimental results presented in a companion paper. The strength of the specimens predicted from the mixed analysis model is found to be in good agreement with that from the experimental results.

Shear mechanism of steel fiber reinforced concrete deep coupling beams

  • Li, Kou;Zhao, Jun;Ren, Wenbo
    • Structural Engineering and Mechanics
    • /
    • 제73권2호
    • /
    • pp.143-152
    • /
    • 2020
  • Deep coupling beams are more prone to suffer brittle shear failure. The addition of steel fibers to seismic members such as coupling beams can improve their shear performance and ductility. Based on the test results of steel fiber reinforced concrete(SFRC) coupling beams with span-to-depth ratio between 1.5 and 2.5 under lateral reverse cyclic load, the shear mechanism were analyzed by using strut-and-tie model theory, and the effects of the span-to-depth ratio, compressive strength and volume fraction of steel fiber on shear strengths were also discussed. A simplified calculation method to predict the shear capacity of SFRC deep coupling beams was proposed. The results show that the shear force is mainly transmitted by a strut-and-tie mechanism composed of three types of inclined concrete struts, vertical reinforcement ties and nodes. The influence of span-to-depth ratio on shear capacity is mainly due to the change of inclination angle of main inclined struts. The increasing of concrete compressive strength or volume fraction of steel fiber can improve the shear capacity of SFRC deep coupling beams mainly by enhancing the bearing capacity of compressive struts or tensile strength of the vertical tie. The proposed calculation method is verified using experimental data, and comparative results show that the prediction values agree well with the test ones.

Seismic performance evaluation of coupled core walls with concrete and steel coupling beams

  • Fortney, Patrick J.;Shahrooz, Bahram M.;Rassati, Gian A.
    • Steel and Composite Structures
    • /
    • 제7권4호
    • /
    • pp.279-301
    • /
    • 2007
  • When coupling beams are proportioned appropriately in coupled core wall (CCW) systems, the input energy from ground motions is dissipated primarily through inelastic deformations in plastic hinge regions at the ends of the coupling beams. It is desirable that the plastic hinges form at the beam ends while the base wall piers remain elastic. The strength and stiffness of the coupling beams are, therefore, crucial if the desired global behavior of the CCW system is to be achieved. This paper presents the results of nonlinear response history analysis of two 20-story CCW buildings. Both buildings have the same geometric dimensions, and the components of the buildings are designed based on the equivalent lateral force procedure. However, one building is fitted with steel coupling beams while the other is fitted with diagonally reinforced concrete coupling beams. The force-deflection relationships of both beams are based on experimental data, while the moment-curvature and axial load-moment relationships of the wall piers are analytically generated from cross-sectional fiber analyses. Using the aforementioned beam and wall properties, nonlinear response history analyses are performed. Superiority of the steel coupling beams is demonstrated through detailed evaluations of local and global responses computed for a number of recorded and artificially generated ground motions.

철골-콘크리트 합성 연결보의 거동과 설계 (Behavior and Design of Steel-Concrete Composite Coupling Beams)

  • 홍성걸;양지연
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.433-438
    • /
    • 2003
  • Structural steel/composite beams provide a viable alternative for coupling individual reinforced concrete wall piers. Well-established guidelines for shear links in eccentrically braced steel frames form the basis of current design guidelines. However, these provisions ignore the effects of nominally reinforced concrete encasement which typically surrounds the coupling beam, and are based on overly conservative assumed deformation demand. A coordinated analytical research program at here has focused on response of steel/composite coupling beams, their connections to reinforced concrete walls, and overall behavior of composite coupled wall systems. Using the results from this study, guidelines for proper design and detailing of steel/composite coupling beams and beam-wall connections have been developed. This paper summarizes the research program, and highlights the basic concepts, important findings, and recommendations.

  • PDF

철골 커플링 보-벽체 접합부의 변형 특성 (Deformation Characteristics of Steel Coupling Beam-Wall Connection)

  • 박완신;전에스더;한민기;김선우;황선경;윤현도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.435-438
    • /
    • 2005
  • The use of new hybrid systems that combine the advantages of steel and reinforced concrete structures has gained popularity. One of these new mixed systems consists of steel beams and reinforced concrete shear wall, which represents a cost- and time-effective type of construction. A number of previous studies have focused on examining the seismic response of steel coupling beams in a hybrid wall system. However, the shear transfer of steel coupling beam-wall connections with panel shear failure has not been thoroughly investigated. The objective of this research was to investigate the seismic performance of steel coupling beamwall connections governed by panel shear failure. To evaluate the contribution of each mechanism, depending upon connection details, an experimental study was carried out The test variables included the reinforcement details that confer a ductile behaviour on the steel coupling beam-wall connection, i.e., the face bearing plates and the horizontal ties in the panel region of steel coupling beam-wall connections. It investigates the seismic behaviour of the steel coupling beams-wall connections in terms of the deformation characteristics. The results and discussion presented in this paper provide background for a companion paper that includes a design model for calculating panel shear strength of the steel coupling beam-wall connections.

  • PDF

세장비 및 대각철근 유무에 따른 고강도 철근보강 콘크리트 연결보의 전단성능 (Effect of Aspect Ratio and Diagonal Reinforcement on Shear Performance of Concrete Coupling Beams Reinforced with High-Strength Steel Bars)

  • 김선우;장석준;윤현도;서수연;천영수
    • 콘크리트학회논문집
    • /
    • 제29권1호
    • /
    • pp.43-51
    • /
    • 2017
  • 현행 규정에 따르면, 세장비 4 미만의 연결보에 대각철근을 사용하도록 규정하고 있다. 그러나 대각선 다발철근 상세는 보 내부의 철근 배근작업을 어렵게 만들고, 이는 또한 시공불량으로 이어질 수 있다. 본 연구에서는 고강도 철근(SD500 및 SD600)으로 보강된 콘크리트 연결보에 관한 실험결과를 나타내었다. 연결보 제작시 시공성을 향상시키기 위하여, 본 연구에서는 헤드바를 갖는 대구경 철근을 사용하였다. 배근상세 및 세장비를 변수로 하여, 2가지의 실규모 연결보를 제작 및 실험하였다. 전단벽을 연결하는 보의 실제 거동특성을 모사하기 위하여, 링크 조인트를 갖는 철골 구조물을 반력바닥에 설치하였다. 실험 결과, 연결보와 전단벽 접합부에서의 균열 및 철근이 항복되면서, 점차 연결보 중앙부로 손상이 진전되는 것으로 나타났다. 연결보는 FEMA 450-1의 설계변위에 대한 전단벽 층간변위 규정에 요구되는 변형능력을 충분히 갖는 것으로 나타났다. 그러나 고강도 철근으로 보강된 연결보의 상세설계를 위해서는, 다양한 세장비가 연결보의 구조거동에 미치는 영향에 관한 연구가 필요하다.

Steel-Plate 매입형 합성 연결보의 접합부 상세에 따른 내진거동 (Seismic Behavior by Beams-Wall Connections depending upon Joint Details of Embedded Steel-Plate Composite Coupling Beams)

  • 주재형;채승윤;김선규;김우재;전호민;박효선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.130-133
    • /
    • 2006
  • Owing to Higher story tendency and ceiling hight restriction of recent times, even though the depth of Coupling Beam decreases the demand efficiency is coming to be high rather so it is the difficult to satisfy a demand efficiency with the actual existing RC/Steel condition. It has been researched a lot of methods as an alternative plan about these but designer cannot apply them for the reason ; the structure standard and theory background are not taking a triangular position. As accomplishing the test research about the beams-wall connections department of steel-plate composite coupling beams from the research in the study it examines closely the beams-wall connections conduct quality and tries to provide the fundamental data for reasonable and optimum connection department designs. It knows that connection fixation degree and composite conduct degree of member part together become the important variable showing an energy dissipation ability in Test result.

  • PDF

The Steel Coupling Beam-Wall Connections Strength

  • 박완신;윤현도
    • 콘크리트학회논문집
    • /
    • 제18권1호
    • /
    • pp.135-145
    • /
    • 2006
  • In high multistory reinforced concrete buildings, coupled shear walls can provide an efficient structural system to resist horizontal force due to wind and seismic effects. Coupled shear walls are usually built over the whole height of the building and re laid out either as a series of walls coupled by beams and/or slabs or a central core structure with openings to accommodate doors, elevators walls, windows and corridors. A number of recent studies have focused on examining the seismic response of concrete, steel, and composite coupling beams. However, since no specific equations are available for computing the bearing strength of steel coupling beam-wall connections, it is necessary to develop such strength equations. There were carried out analytical and experimental studies to develop the strength equations of steel coupling beam-connections. Experiments were conducted to determine the factors influencing the bearing strength of the steel coupling beam-wall connection. The results of the proposed equations were in good agreement with both test results and other test data from the literature. Finally, this paper provides background for design guidelines that include a design model to calculate the bearing strength of steel coupling beam-wall connections.

일반 철근 배근 상세를 갖는 강섬유 보강 콘크리트 연결보의 전단강도 평가 (Shear Strength Evaluation of Steel Fiber Reinforced Concrete Coupling Beams with Conventional Reinforcements Details)

  • 송성휘;손동희;배백일;최창식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권1호
    • /
    • pp.37-45
    • /
    • 2023
  • 본 연구의 목적은 기존 연결보의 사인장 파괴를 방지하고 연결보의 전단강도를 증가시키며 증가분을 정량적으로 평가하는 것이다. 강섬유는 전단강도를 향상시키고 파괴 메커니즘을 부분적으로 변화시킬 수 있지만 이는 일반적인 RC보와 기둥에 대한 연구결과이며, 강섬유 보강콘크리트에 대한 연결보의 전단강도 증진에 대한 연구는 아직까지 부족한 실정이다. 따라서, 강섬유에 의한 증가된 전단강도와 이에 따른 파괴 메커니즘 변화를 확인하기 위해 강섬유의 혼입률을 변수(0%, 1%, 2%)로 세 개의 실험체를 제작하여 반복가력 실험을 수행하였다. 그 결과, 강섬유를 보강한 실험체(1%, 2%)가 그렇지 않은 실험체(0%) 대비 최대강도 발현 후 콘크리트의 전단저항 기여분이 증가됨에 따라 전단강도가 증진되었다.