• 제목/요약/키워드: steel connections

검색결과 853건 처리시간 0.025초

깊이 1200mm급 변단면보의 중간모멘트골조용 내진접합부 개발 (Beam-Column Connection with 1200mm Deep Multi-Reduced Taper Beam for Intermediate Moment Frame)

  • 정시화;알미아이유 로벨 원디므;박만우;주영규
    • 대한건축학회논문집:구조계
    • /
    • 제35권4호
    • /
    • pp.135-146
    • /
    • 2019
  • Deep beam has high section modules compared with shallow beam of the same weight. However, deep beam has low rotational capacity and high possibility of brittle failure so it is not possible to apply deep beams with a long span to intermediate moment frames, which should exhibit a ductility of 0.02rad of a story drift angle of steel moment frames. Accordingly, KBC and AISC limit the beam depth for intermediate and special moment frame to 750mm and 920mm respectively. The purpose of this paper is to improve the seismic performance of intermediate moment frame with 1200mm depth beam. In order to enhance vulnerability of plastic deformation capacity of deeper beam, Multi-Reduced Taper Beam(MRTB) shape that thickness of beam flange is reinforced and at the same time some part of the beam flange width is weakened are proposed. Based on concept of multiple plastic hinge, MRTB is intended to satisfy the rotation requirement for intermediate moment frame by dividing total story drift into each hinge and to prevent the collapse of the main members by inducing local buckling and fracture at the plastic hinge location far away from connection. The seismic performance of MRTB is evaluated by cyclic load test with conventional connections type WUF-W, RBS and Haunch. Some of the proposed MRTB connection satisfies connection requirements for intermediate moment frame and shows improved the seismic performance compared to conventional connections.

천장 브래킷을 이용한 완전강접합 모듈러 시스템의 구조성능 (Structural Performance of the Modular System with Fully Restrained Moment Connections using Ceiling Bracket)

  • 이승재;곽의신;박재성;강창훈;손수덕
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.37-44
    • /
    • 2017
  • Due to structural characteristics, construction costs and duration of a modular system would be saved by minimizing the schedule on the job site. As such, it is crucial to develop a connection that can guarantee stiffness while allowing for simple assembling. Particularly, the mid- to high-rise construction of the modular system necessitates the securing of the structural stability and seismic performance of multi-unit frames and connections, and thus, the stiffness of unit-assembled structures needs to be re-evaluated and designed. However, evaluating a frame consisting of slender members and reinforcing materials is a complicated process. Therefore, the present study aims to examine the structural characteristics of a modular unit connection based a method for reinforcing connection brackets and hinges while minimizing the loss of the cross section. Toward this end, the study modeled the beam-to-column connection of a modular system with the proposed connection, and produced a specimen which was used to perform a cycling loading test. The study compared the initial stiffness, the attributes of the hysteretic behavior, and the maximum flexural moment, and observed whether the model acquired the seismic performance, compared to the flexural strength of the steel moment frame connection that is required by the Korean Building Code. The test results showed that the proposed connection produced a similar initial stiffness value to that of the theoretical equation, and its maximum strength exceeded the theoretical strength. Furthermore, the model with a larger ceiling bracket showed higher seismic performance, which was further increased by the reinforcement of the plate.

A re-examination of the current design rule for staggered bolted connections

  • Xue-Mei Lin;Michael C.H. Yam;Ke Ke;Binhui,Jiang;Qun He
    • Steel and Composite Structures
    • /
    • 제46권3호
    • /
    • pp.403-416
    • /
    • 2023
  • This paper summarised and re-examined the theoretical basis of the commonly used design rule developed by Cochrane in the 1920s to consider staggered bolt holes in tension members, i.e., the s2/4g rule. The rule was derived assuming that the term two times the bolt hole diameter (2d0) in Cochrane's original equation could be neglected, and assuming a value of 0.5 for the fractional deduction of a staggered hole in assessing the net section area. Although the s2/4g rule generally provides good predictions of the staggered net section area, the above-mentioned assumptions used in developing the rule are doubtful, in particular for a connection with a small gauge-to-bolt-hole diameter (g/d0) ratio. It was found that the omission of 2d0 in Cochrane's original equation appreciably overestimates the net section area of a staggered bolted connection with a small g/d0 ratio. However, the assumed value of 0.5 for the fractional deduction of a staggered hole underestimates the staggered net section area for small g/d0 ratios. To improve the applicability of the above two assumptions, a modified design equation, which covers a full range of g/d0 ratio, was proposed to accurately predict the staggered net section area and was validated by the existing test data from the literature and numerical data derived from this study. Finally, a reliability analysis of the test and numerical data was conducted, and the results showed that the reliability of the modified design equation for evaluating the net section resistance of staggered bolted connections can be achieved with the partial factor of 1.25.

Presenting an advanced component-based method to investigate flexural behavior and optimize the end-plate connection cost

  • Ali Sadeghi;Mohammad Reza Sohrabi;Seyed Morteza Kazemi
    • Steel and Composite Structures
    • /
    • 제52권1호
    • /
    • pp.31-43
    • /
    • 2024
  • A very widely used analytical method (mathematical model), mentioned in Eurocode 3, to examine the connections' bending behavior is the component-based method that has certain weak points shown in the plastic behavior part of the moment-rotation curves. In the component method available in Eurocode 3, for simplicity, the effect of strain hardening is omitted, and the bending behavior of the connection is modeled with the help of a two-line diagram. To make the component method more efficient and reliable, this research proposed its advanced version, wherein the plastic part of the diagram was developed beyond the guidelines of the mentioned Regulation, implemented to connect the end plate, and verified with the moment-rotation curves found from the laboratory model and the finite element method in ABAQUS. The findings indicated that the advanced component method (the method developed in this research) could predict the plastic part of the moment-rotation curve as well as the conventional component-based method in Eurocode 3. The comparison between the laboratory model and the outputs of the conventional and advanced component methods, as well as the outputs of the finite elements approach using ABAQUS, revealed a different percentage in the ultimate moment for bolt-extended end-plate connections. Specifically, the difference percentages were -31.56%, 2.46%, and 9.84%, respectively. Another aim of this research was to determine the optimal dimensions of the end plate joint to reduce costs without letting the mechanical constraints related to the bending moment and the resulting initial stiffness, are not compromised as well as the safety and integrity of the connection. In this research, the thickness and dimensions of the end plate and the location and diameter of the bolts were the design variables, which were optimized using Particle Swarm Optimization (PSO), Snake Optimization (SO), and Teaching Learning-Based Optimization (TLBO) to minimization the connection cost of the end plate connection. According to the results, the TLBO method yielded better solutions than others, reducing the connection costs from 43.97 to 17.45€ (60.3%), which shows the method's proper efficiency.

반복하중을 받는 하이브리드 프리캐스트 보-기둥 접합부의 성능평가 (Structural Capacity Evaluation of Hybrid Precast Concrete Beam-Column Connections Subjected to Cyclic Loading)

  • 최현기;유창희;최윤철;최창식
    • 콘크리트학회논문집
    • /
    • 제22권3호
    • /
    • pp.325-333
    • /
    • 2010
  • 이 연구에서는 시공성과 경제성이 향상되고 중진 지역에서 사용할 수 있는 새로운 프리캐스트 콘크리트 보-기둥 접합부 상세를 복합구조로 개발하고 실험을 통하여 이를 검증하였다. 이 상세는 기둥 속에 매립된 각형강관과 보U형 단부를 갖는 보 단부에 매립된 플레이트를 볼트로 결합시킬 수 있는 구조로 되어있다. 하이브리드 스틸-콘크리트 접합합부에 앞서 콘크리트가 조기에 파괴되는 것을 막기 위하여 접합부 부분에 ECC(engineered cementitious composite)를 사용하였다. 개발된 접합부 상세에 대한 성능을 검증하기 위하여 보-기둥 접합부 실험체를 계획하여 이에 대한 내진성능 실험을 실시하였다. 내부 접합부에 있어서는 접합부 횡보강근 유무와 현장타성 범위를 변수로 3개의 실험체를 제작하였다. 실험은 기둥에 일정 축력을 가한 상태에서 PC기둥 단부에 액츄에이터를 설치하여 변위제어로써 반복가력 하여 실시하였다. 실험에서 얻은 자료를 접합부 내력, 강성, 에너지 소산능력 등에 대하여 분석하였으며, 그 결과 이 연구에서 제시한 새로운 보-기둥 접합부 상세는 강재와 콘크리트 그리고 ECC 사이에서의 다른 부착 특성 때문에 구조거동에서 차이점이 관찰되었으며, 기준 실험체를 제외한 두 실험체의 경우 ECC 및 철골연결재에 의해 소성힌지를 유도할 수 있는 것으로 나타났다. 그리고 프리캐스트 접합부는 높은 일체성과 모멘트 저항 능력을 보이며 중진 지역에서 사용가능함을 보였다.

실물대 목업실험에 의한 슬라이딩스텝 철골계단의 진동 및 구조성능 평가 (Evaluation of Vibration and Structural Performance of an Innovative Sliding Step Steel Stair Using Full-Scale Mock-up Test)

  • 김성용;이철호;김나은;조성상;정운옥
    • 한국강구조학회 논문집
    • /
    • 제26권6호
    • /
    • pp.511-522
    • /
    • 2014
  • 본 연구에서는 주거용 및 사무용 계단시공의 작업공정의 단순화 및 시공품질 향상을 목적으로 개발된 혁신적인 계단 시스템인 슬라이딩스텝 철골계단의 진동 및 구조성능 평가를 수행하였다. 슬라이딩스텝 철골계단은 각형 강재 스트링거와 시공오차를 흡수할 수 있도록 설계된 스트링거 연결재 및 계단벽체 시공이 용이하도록 벽체 반대방향으로 이동이 가능한 슬라이딩 스텝으로 구성되어 있다. 하지만 철골계단의 경우 철골 접합부의 구조적 안전성 확보와 더불어, 비교적 경량에 저감쇠인 철골재 사용으로 인한 낮은 진동성능이 발현될 수 있기 때문에 진동성능에 대한 확보를 파악하는 것이 필수적으로 요구된다. 이에 본 연구에서는 진동성능 및 구조적 안전성 확보여부를 파악하기 위해 실물대 목업실험을 실시하였다. 진동성능 및 중량으로 인한 경제성 등을 종합적으로 판단하기 위해 콘크리트를 채운 스트링거와 콘크리트를 채우지 않은 스트링거를 교체해가며 각 경우에 대한 주거용 및 사무용 계단의 진동성능을 평가하였다. 또한 각 용도별로 한 개의 계단을 선정한 후, 재하실험을 통해 철골 접합부의 구조적 안전성과 스트링거 중앙부의 잔류 처짐 및 사용성 검토를 수행하였다. 실물대목업실험 결과 접합부 시스템의 경우 사용하중의 160%인 극한하중에 대해서도 탄성상태를 유지하며 재하실험 후에도 어떠한 균열이나 이상이 발견되지 않는 등 충분한 강성과 강도를 확보하고 있음을 확인하였다. 또한 스트링거 중앙부 처짐은 주거용/사무용 계단 모두 역시 동일한 하중조건 하에서 사용성에 문제가 없을 정도의 미미한 수준의 최대처짐과 잔류처짐이 발생하였으며, 최대하중이 가해질 때까지 스트링거가 탄성상태를 유지하는 등 설계하중을 지지할 수 있는 충분한 내력을 보유한 것으로 평가되었다. 진동성능 검토 결과 총 일곱 개의 스트링거 타입 중 다섯 개의 타입이 북미기준와 유럽기준에서 제시하는 기준의 허용치를 만족함을 확인하였다.

보-기둥 접합부를 고려한 5층 철골골조구조물의 비탄성 정적해석 (Pushover Analysis of a Five-Story Steel Framed Structure Considering Beam-to-Column Connection)

  • 강석봉;이재환
    • 한국강구조학회 논문집
    • /
    • 제22권2호
    • /
    • pp.129-137
    • /
    • 2010
  • 본 연구에서는 횡력을 받는 구조물 거동에 대한 보-기둥 접합부의 영향을 확인하기 위하여 5층 철골구조물을 KBC2005 건축구조설계기준에 맞게 구조설계 하였으며 접합부를 완전 강접합부로 이상화한 경우와 반강접 접합부로 설계하였다. 철골 보 및 기둥의 모멘트-곡률관계는 화이버모델을 이용하여 확인하였으며 반강접 접합부의 모멘트-회전각 관계는 3-매개변수 파워모델을 이용하여 나타내었다. 구조물 거동에 대한 고차모드의 영향을 확인하기 위하여 KBC2005 등가정적 횡하중과 고차모드를 고려한 횡하중을 재하하였다. 5층 철골구조물은 개별 골조와 연결골조의 2차원 구조물로 이상화하였다. 횡하중을 받는 2차원 구조물에 대한 푸쉬오버 구조해석을 실시하여 지붕충변위-밑면전단력, 초과강도계수, 연성계수, 반응수정계수와 같은 설계계수, 접합부 요구연성도 그리고 소성힌지 분포 등을 확인하였다. 예제 구조물은 기준의 반응수정계수 보다 큰 값을 보였고 고차모드의 반응수정계수에 대한 영향은 거의 없었고 KBC2005 횡하중은 안전한 편에 속했다. TSD 접합부는 예제 구조물에서 경제성과 안전성을 확보할 수 있음을 확인할 수 있었다.

모듈러 골조의 각형강관 기둥과 C형강 보 접합부의 거동 평가 (Behavior of C-Shaped Beam to Square Hollow Section Column Connection in Modular Frame)

  • 이상섭;박금성;홍성엽;배규웅
    • 한국강구조학회 논문집
    • /
    • 제27권5호
    • /
    • pp.471-481
    • /
    • 2015
  • 모듈러 건축은 사전에 설계 검토된 건물 요소를 공장에서 모듈로 제작하여 현장으로 운송 조립하는 프리패브 건축 시스템이다. 모듈러 건축물의 구조 형식은 공법, 재료, 부재 구성 등에 따라 다양하게 구분될 수 있지만 사용되는 모듈의 구조 형식은 크게 벽식과 가구식으로 나눌 수 있다. 벽식 모듈은 모듈의 입면을 패널을 이용하여 구성하여 수직하중과 수평하중을 전달시키는 방식이다. 가구식 모듈은 기둥과 보를 이용하여 모듈을 구성하고, 용도에 맞춰 입면을 마감하거나 개방시켜 놓는 방식이다. 이 두 가지 모듈 방식은 국내에도 사용된 바 있으나 최근 가구식 모듈이 보편화되고 있다. 가구식 모듈의 기둥 부재로 각형강관이 일반적으로 사용되고 있으며, 보 부재로 C형강 또는 H형강이 사용되고 있다. 각형강관이 기둥 부재로 사용된 가구식 모듈간 접합을 위해 각형강관 기둥 단부에 고력볼트를 채우기 위해 액세스 홀을 가공하는 경우가 있다. 액세스 홀은 볼트체결을 위해 사람의 손이나 공구가 폐쇄형 단면인 각형강관 내부에 접근하기 위한 개구부로 액세스 홀은 기둥-보 접합부의 거동에 영향을 미치는 패널존을 약화시킬 가능성이 높다. 이 연구에서는 가구식 모듈의 기둥-보 접합부 거동에 영향을 미치는 액세스 홀, 기둥 두께, 다이아프램을 변수로 5개의 실험체를 제작하여 실험을 실시하였고 그 결과를 분석하여 제시하였다.

내부유공판을 사용한 각형 CFT 기둥-보 단순인장 접합부의 실험적 연구 (An Experimental Study on Simple Tension Connections for Square CFT Column to Beam Using Internal Plate with Holes)

  • 이성희;정헌모;양일승;최성모
    • 한국강구조학회 논문집
    • /
    • 제21권6호
    • /
    • pp.575-583
    • /
    • 2009
  • 최근 건물이 고층화 됨에 따라 건물의 중량감소와 시공의 효율성 확보를 위해 기존 S, RC, SRC 이외에 새로운 구조시스템이 적용되고 있으며, 그중에서도 CFT 구조는 우수한 구조성능과 시공성으로 많은 건설현장에 적용되어 왔다. CFT 구조는 접합부 구성시 보 플랜지 하중을 기둥과 반대편 보에 원활히 전달하기 위한 다이아그램이 필요하며 특히 기둥 좌우에 춤이 다른 보가 접합될 때 보의 하부 플랜지 하중전달을 위한 다이아프램 구성과 콘크리트 충전성 확보에 어려움이 있었다. 본 연구에서는 하부 보 플랜지 하중을 기둥에 원활히 전달하기 위해 CFT 기둥 내부에 유공판을 세로로 접합하는 형식의 접합상세를 제안하였다. 이 접합형식은 CFT 기둥 내부에 콘크리트가 충전될 때 콘크리트가 내부 유공판의 구멍을 관통하여 채워짐으로써 보 플랜지 하중전달에 콘크리트의 앵커효과를 이용하는 방법이며 유공판이 수직으로 설치됨으로써 콘크리트 충전성도 향상시킬 수 있다. 제안된 접합부의 구조거동분석을 위해서 내부유공판의 설치방향, 콘크리트의 충전 유/무, 내부유공판의 두께, 전단구멍의 개수등을 변수로하여 5개의 실험체를 제작하고 실험체의 실험적연구를 진행하였다.

드리프트 핀의 배열 형태가 집성재 접합부의 회전 거동 및 강도 성능에 미치는 영향 (Effect of Drift Pin Arrangement for Strength Property of Glulam Connections)

  • 이인찬;박천영;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권3호
    • /
    • pp.10-21
    • /
    • 2007
  • 집성재 다우얼 접합부가 적용되는 기둥의 기초, 기둥-보 접합부에는 회전이 발생하므로 접합부의 모멘트 성능에 대한 연구가 필요하다. 접합부의 회전에 의해서 섬유방향과 각을 이루어 작용하는 하중을 섬유방향에 평행한 하중과 수직한 하중으로 단순화 하여 거동을 해석하고 예측하였다. 드리프트 핀의 휨강도 및 지압응력을 평가하였으며, 섬유방향에 평행한 인장하중과 수직한 인장하중을 받는 접합부의 끝면 거리를 다르게 하여 접합부의 인장형 전단성능을 시험하였고 회전이 작용하는 접합부는 드리프트 핀의 개수와 배열 방향을 다르게 하여 시험하였다. 접합부에 인장하중이 작용할 때 항복 이후의 변형량은 드리프트 핀의 소성변형에 의해서 발생하며, 집성재의 끝면 거리 확보에 의한 드리프트 핀의 변형 흡수가 접합부 전체의 변형량에 영향을 주는 것으로 판단된다. 2개의 드리프트 핀이 섬유방향에 평행하게 배열된 경우(b2h)에는 섬유방향에 수직한 인장하중 거동을 나타내고, 2개의 드리프트 핀이 섬유방향에 수직하게 배열된 경우(b2v)에는 섬유방향에 평행한 인장하중 거동을 나타내는 것으로 평가된다. 4개의 드리프트 핀이 정사각 배열된 접합부의 경우(b4)에 2개의 드리프트 핀이 섬유방향에 평행하게 배열된 접합부(b2h)의 약 1.7배의 하중 성능을 나타냈으며, 접합부에 회전이 작용하여 섬유방향과 각을 이루는 하중을 섬유방향에 대한 평행 또는 수직한 하중으로 치환하여 거동을 평가, 예측하는 것이 가능하다고 판단된다.