• Title/Summary/Keyword: steam room

Search Result 90, Processing Time 0.133 seconds

The cases report of postpartum hyperhidrosis caused by keeping overwarm (산욕기 과보온으로 야기된 산욕기 발한 과다에 대한 증례 보고)

  • Cho, Hyung-Lae
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.18 no.4
    • /
    • pp.203-210
    • /
    • 2005
  • Purpose : The keeping warm and avoidance of cold are one of important Korean traditional postpartum care, but sometimes overwarm for example over-bundling, an overheated room or a steam bath cause heavy sweats. I observed and treated three patients complained of heavy sweats, chills, fatigue, malaise, cold sensation and pain caused by keeping overwarm for postpartum care. Although the symptoms have aggravated, they have maintained keeping overwarm because of a belief of Korean traditional postpartum care. The purpose of these cases studies are to report postpartum hyperhidrosis caused by keeping overwarm and to make a point of keeping the appropriate room temperature and humidity during puerperium. Methods : I observed and treated three patients complained of heavy sweats, chills, fatigue, malaise, cold sensation and pain caused by keeping overwarm for postpartum care. I found that a cause of the symptoms was hyperhidrosis by keeping overwarm, and administered herbal medicine and was to keep the appropriate room temperature. Results : After medication of Herbal medicine(補中益氣湯加味方) and keeping the appropriate room temperature, they were improved. Conclusion : Postpartum care is not to keep overwarm but to keep the appropriate room temperature and humidity.

  • PDF

Comparative Study on Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air-Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 비교연구)

  • Kim, Hyung-Tae;Song, Gen-Soo;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun;Kwon, Oh-Myung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1249-1255
    • /
    • 2011
  • In modern large-scale semiconductor manufacturing clean rooms, the energy consumed by the outdoor air-conditioning system during heating, humidification, cooling, and dehumidification of the incoming outdoor air represents about 45% of the total air-conditioning load required to maintain a clean-room environment. In particular, the energy required for humidification of the outdoor air in winter is very high. Therefore, evaluation and comparison of the energy consumption in key humidification systems, viz., steam-humidification and water-spray-humidification systems, used in outdoor air-conditioning systems would be useful to reduce the outdoor air-conditioning load in clean rooms. In the present study, an experiment with an outdoor air flow of 1000 $m^3$/h was conducted to compare the air-conditioning process and energy consumption in outdoor air-conditioning systems with electrodeboiler steam humidifiers and air-washer water spray humidification systems. The experimental results showed that the water-spray-humidification-type outdoor air-conditioning system consumed less electrical power than did the steam-humidification-type system and was more energy efficient during winter.

A Study on the Facilities Layout of Lower Floor and Space Characteristics Through Analysis of Newly Established Schools in Chungbuk since 2010 (충북의 2010년 이후 신설된 학교 분석을 통한 저층부 배치 시설 및 공간 특성 연구)

  • Kang, Hye-Jin;Jung, Jin-Ju
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.22 no.2
    • /
    • pp.3-13
    • /
    • 2015
  • The policy of the Ministry of education through the social awareness and issues are being changed. Accordingly, in response to the school building which also has to be changed. This study is Low-floor(1~2 floor) for high accessibility, important management and a lot of locomotion. This study is analysis by floor of newly established schools in Chungbuk. Facility and space on the possible low-floor situated are classified administrative zone, health zone, student support + local exchange zone, STEAM(creativity, personality) supporting zone. The administrative area includes administration office, principal's office and board rooms. The administrative zone is located against schoolyard. Because it is possible visual control of schoolyard. also it controls visitor access so it is placed near main entrance. Health zone is located near a special class, counseling center and wee class for emergency situation. and is located near schoolyard for visual control. Student support + local exchange area includes library and computer lab, audio-visual room, auditorium or gymnasium. It put more emphasis resident welfare, culture and education. So it opens for local residents. It is located center of few stories or near entrance. STEAM(creativity, personality) supports science lab, art room, family room. It is possible such a theory class, experience class and indoor and outdoor class. It is located few floors. This study is used as a reference for school building projects planing.

Burst Behavior for Mechanically Machined Axial Flaws of Steam Generator Tubings

  • Hwang, Seong Sik;Kim, Hong Pyo;Kim, Joung Soo
    • Corrosion Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.30-33
    • /
    • 2004
  • It has been reported that some events of a rupture of seam generator tube have occurred in nuclear power plants around the world. Main causes of the leakage are from various types of corrosion in the steam generator(SG) tubings. Primary water stress corrosion cracking(PWSCC) of steam generator tubings have occurred in many tubes in Korean plant, and they were repaired using sleeves or plugs, In order to develop proper repair criteria, it is necessary to ascertain the leak behavior of the tubings. A high pressure leak and burst testing system was manufactured. Various types of Electro Discharged Machined (EDM) notches were developed on the SG tubes. Leak rate and burst pressure were measured on the tubes at room temperature. Burst pressure of the part through wall defected tubes depends on the defect depth, Water flow rates after the burst were independent of the t1aw types; tubes having 20 to 60 mm long EDM notches showed similar flow rates regardless of the defect depth. A fast pressurization rate gave the tube a lower burst pressure than the case of a slow pressurization.

Analysis of Tube Support Plate Reinforcement Effects on Burst Pressure of Steam Generator Tubes with Axial Cracks (증기발생기 전열관지지판의 축균열 파열억제 효과 분석)

  • Kang, Yong Seok;Lee, Kuk Hee;Kim, Hong Deok;Park, Jai Hak
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.168-173
    • /
    • 2015
  • A steam generator tubing is one of the main pressure boundary of the reactor coolant system in the nuclear power plants. Structural integrity refers to maintaining adequate margins against failure of the tubing. Burst pressure of a tube at tube support plate can be higher than that for a free-span tube because failure behaviors could be interfered from the tube support plate. Alternative repair criteria for out-diameter stress corrosion cracking indications in tubes to the drilled type tube support plate were developed, however, there are very limited information to the eggcrate type tube support plate. This paper discussed reinforcement effect of steam generator tube burst pressure with axial out-diameter stress corrosion cracking within an eggcrate type tube support plate. A series of tube burst tests were performed under the room temperature and it was found out that there is no significant but marginal effects.

The Sliding Wear Behavior of Inconel 600 Mated with SUS 304 (SUS 304에 대한 Inconel 600의 Sliding 마모거동)

  • Kim, Hun;Choi, Jong-Hyun;Kim, Jun-Ki;Park, Ki-Sung;Kim, Seung-Tae;Kim, Seon-Jin
    • Korean Journal of Materials Research
    • /
    • v.11 no.10
    • /
    • pp.841-845
    • /
    • 2001
  • The steam generator tubes of power plant damaged by sliding wear due to flow-induced motion of foreign object. Amount of wear have been predicted by Achard's wear equation until now. However, there are large error and low reliability, because this equation regards wear coefficient(k) as constant. The sliding wears tests have been performed at room temperature to examine parameters of wear (wear distance, contact stress). The steam generator tube material for wear test is used Inconel 600 and foreign object material is used 304 austenite stainless steel. The sliding wear tests show that the amount of wear is not linearly proportional to the wear distance(for 374 austenite stainless steel). According to experimental result, wear coefficient is not constant k but function k(s) of wear distance. The newly modified wear predictive equation V=k(s)F have small error and high reliability.

  • PDF

Study on the Development of Super-High-Early-Strength Mortar Using the Hardening catalyst and High early strength cement (조강시멘트를 사용한 초조강 모르타르 개발에 관한 연구)

  • Cho, In-Sung;Hur, Yeon-Ok;Min, Tae-Beom;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.217-219
    • /
    • 2012
  • In this study, the experiment was conducted in the level of mortar as one of the basic studies on pre-cast concrete which acceleration curing is not done. This study has the purpose to develop the strength of mortar into 20MPa within 6 hours in the condition of room temperature using admixtures which can accelerate C3S hydration reaction. In this experiment, W/C was fixed into 20%, PCE which can stimulate C3S was used as an accelerating admixture. From the results of this experiment, maximum content of accelerating admixture was 1%. Also, as more than 20MPa was measured through 6-hour compressive strength, it can be known that strength can be developed without steam-curing.

  • PDF

Experimental assessment of thermal radiation effects on containment atmospheres with varying steam content

  • R. Kapulla;S. Paranjape;U. Doll;E. Kirkby;D. Paladino
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4348-4358
    • /
    • 2022
  • The thermal-hydraulics phenomena in a containment during an accident will necessarily include radiative heat transfer (i) within the gas mixture due to the high radiative absorption and emission of steam and (ii) between the gas mixture and the surrounding structures. The analysis of some previous PANDA experiments (PSI, Switzerland) demonstrated the importance of the proper modelling of radiation for the benefit of numerical simulations. These results together with dedicated scoping calculations conducted for the present experiments indicated that the radiative heat transfer is considerable, even for a very low amount of steam (≈2%). The H2P2 series conducted in the large-scale PANDA facility at the Paul-Scherrer-Institut (PSI) in the framework of the OECD/NEA HYMERES-2 project is intended to enhance the understanding of thermal radiation phenomena and to provide a benchmark for corresponding numerical simulations. Thus, the test matrix was tailored around the two opposite extremes: either gas compositions with small steam content such that radiative heat transfer phenomena can be neglected. Or gas mixtures containing larger amounts of steam, so that radiative heat transfer is expected to play a dominant role. The H2P2 series consists of 5 experiments designed to isolate the radiation phenomena from convective and diffusive effects as much as possible. One vessel with a diameter of 4 m and a height of 8 m was preconditioned with different mixtures of air / steam at room and elevated temperatures. This was followed by the build-up of a stable helium stratification at constant pressure in the upper part of the vessel. After that, helium was injected from the top into the vessel which leads to an increase of the vessel pressure and a corresponding elevation-dependent and transient rise of the gas temperature. It is shown that even the addition of small amounts of steam in the initial gas atmosphere considerably impacts the radiative heat transport throughout all phases of the experiments and markedly influences i) the monitored gas peak temperature, ii) the temperature history during the compression and iii) the following relaxation phase after the compression was stopped. These PANDA experiments are the first of its kind conducted in a large scale thermal-hydraulic facility.

A Suggestion of the Hydrogen Flame Speed Correlation under Severe Accidents (중대사고시 수소연소에 의한 화염속도 상관식 제시)

  • Kang, Chang-Woo;Chung, Chang-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • The flame speed correlation considering thermal-hydraulic phenomena under severe accidents is proposed and correction coefficients are defined. This correlation modifies the pressure dependency in Iijima-Takeno correlation and adds the steam suppression effects to it in the anticipated hydrogen and steam concentration ranges under severe accidents. The existing models of flame speed due to hydrogen combustion under severe accidents are based on the experiments which were performed merely at room temperature and atmospheric pressure. They have difficulty in predicting a accurate flame speed in a case of high temperature and pressure during severe accidents. Thus the flame structure is assumed as a prerequisite to the reliable determination of flame speed and theoretical model is developed. To examine the validity, flame speeds in various conditions calculated by this model are compared with those obtained by the calculation of the existing correlations of the codes such as improved HECTR and MAAP. Also the steam suppression ratio is quantified and the steam suppression coefficient is defined as a composition of mixture. Initial temperature and pressure dependencies are investigated and correction coefficents are determined. More experimental studies can be recommended to improve this correlation to its further works.

  • PDF

Experimental investigation of impact-sliding interaction and fretting wear between tubes and anti-vibration bars in steam generators

  • Guo, Kai;Jiang, Naibin;Qi, Huanhuan;Feng, Zhipeng;Wang, Yang;Tan, Wei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1304-1317
    • /
    • 2020
  • The tubes in a heat exchanger, such as a steam generator (SG), are subjected to crossflow, and interaction between tubes and supports can happen, which can cause fretting wear of tubes. Although many experiments and models have been established, some detailed mechanisms are still not sufficiently clear. In this work, more attention is paid to obtain the regulation of impact and sliding in the complex process and many factors, such as excitation forces and clearances. The responses and contact forces were analyzed to obtain clear understanding of the influences of these factors. Room temperature tests in the air were established. The results show that the effect of clearance on the normal work rate is not monotonous and instead has two peaks. The force ratio can influence the normal work rate by changing the distribution of contact angles, which can result in higher sliding in the contact process. Fretting wear tests are conducted, and the wear surfaces are analyzed by a scanning electron microscope (SEM) and energy dispersive X-ray spectrometer (EDX). The results of this work can serve as a reference for impactsliding contact analysis between AVBs and tubes in steam generators.