• Title/Summary/Keyword: steam room

Search Result 90, Processing Time 0.024 seconds

A Study on "Records on Steam Room(蒸室記)" (증실기(蒸室記) 연구(硏究))

  • Park, Sang-Young;Kwon, Oh-Min;Ahn, Sang-Young;Han, Chang-Huyn;Oh, Jun-Ho
    • Journal of Korean Medical classics
    • /
    • v.24 no.5
    • /
    • pp.119-129
    • /
    • 2011
  • The Chapter of "Records on Steam Room(蒸室記)" in "Shandangjip(山堂集)" by CHOI Chungsung is a rare and notable one in that it contains the first concrete and detailed description and view of steam shower in the early Joseon Dynasty. It is known that Choi's Wind stroke(brain stroke) deteriorated due to excessive steam shower. He unreasonably entered the steam room 4 or 5 times a day for 9 consecutive days even though external pathogens had intruded into visceral organs and his energizing chi got less and weaker. By this excessive steam showering, his righteous chi was exhausted and eventually burned out. Given some records in the Annals of the Joseon Dynasty writing that people died due to excessive steam shower, there was no established medical theory on the effect of steam shower before the publication of "Donguibogam(東醫寶鑑)".

An Assessment of Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 평가)

  • Kim, Ki-Cheol;Song, Gen-Soo;Kim, Hyung-Tae;Yoo, Kyung-Hoon;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.55-63
    • /
    • 2013
  • For a large-scale semiconductor manufacturing clean room, the energy consumed in an outdoor air conditioning system to heat, humidify, cool and dehumidify incoming outdoor air is very large. In particular, the energy requirement to humidify outdoor air in the winter season is generally known to be high. Recently, in order to overcome the high energy consumption nature of a steam generator in a conventional steam humidification type outdoor air conditioning system, an air washer is often introduced instead of the steam generator in the outdoor air conditioning system, which can be called a water spray humidification type outdoor air conditioning system. Therefore, the assessment and comparison of the annual energy consumed in the steam humidification type and the water spray humidification type outdoor air conditioning systems deserves to be examined in order to reduce the outdoor air conditioning load of a clean room. In the present study, a numerical analysis was conducted to obtain the annual electric power consumption of the two outdoor air conditioning systems. It was shown from the comparison of the numerical results that the water spray humidification type outdoor air conditioning system can reduce about 30% of annual electric power consumption of the steam humidification type outdoor air conditioning system.

Production of SCC Flaws and Evaluation Leak Behavior of Steam Generator Tubes (누설 및 파열실험용 SCC 결함 전열관 제작 및 누설거동 평가)

  • Hwang, Seong-Sik;Jung, Man-Kyo;Park, Jang-Yul;Kim, Hong-Pyo
    • Corrosion Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.188-192
    • /
    • 2009
  • A forced outage due to a steam generator tube leak in a Korean nuclear power plant was reported.1) Primary water stress corrosion cracking has occurred in many tubes in the plant, and they were repaired using sleeves or plugs. In order to develop proper repair criteria, it is necessary to understand the leak behavior of the tubes containing stress corrosion cracks. Stress corrosion cracks were developed in 0.1 M sodium tetrathionate solution at room temperature. Steam generator(SG) tubes with short cracks were successfully fabricated with a restricted solution contact method. The leak rates of the degraded tubes were measured at room temperature. Some tubes with 100 % through wall cracks showed an increase of leak rate with time at a constant pressure.

A Study on the Quality Control for the Holding Method of Food Served by an Industry Foodservice Establishment (산업체 급식소에서 제공되는 음식의 조리후 보관방법에 따른 품질평가)

  • 김혜영;고성희
    • Korean journal of food and cookery science
    • /
    • v.12 no.2
    • /
    • pp.129-137
    • /
    • 1996
  • The purpose of this study was that to estimate the microbial and sensory quality by the method and time of holding in the step of holding of Cow's Knee Broth, Stir-Fry Pork and Cooked Cuttlefish that were provide at the industry foodservice establishment, then to suggest safer feeding by the reasonable holding method. The results are as follows: Cow's Knee Broth: holding at room temperature was shown that the number of mi- crobiology by passage of the holding time was higer than the case of holding at steam table, but it was lower after reheating it. As a result of sensory test, it was exellent to holding at steam table and to reheat after holding room temperature within four hours and six hours each. Stir-Fry Pork: as a result of microbial analysis, in the case of holding at the steam table microbes increased safer two hours, but after four and six hours they little reduced. In the case of holding at room temperature the number of microbes increased according to the passage of time. As a result of sensory analysis, its taste of room temperature holding was fine until four and six hours each. Cooked Cuttlefish: as a microbial analysis, it was shown that the amount of total plate counts of room temperature holding ten times as high as the latter after six hours. As the result of sensory analysis, the cold holding was better until six hours and the room temperature holding was fine just until two hours. As a result of food poisoning bacteria, it was negative in every test in sample against Salmonella, Staphylococcus aureus, Vibrio parahaemolyticus.

  • PDF

A Study on the Internal Temperature Reduction of PKG-A Water-jet-room by Substituting Heat Insulation Materials (단열재 개선을 통한 PKG-A Water Jet Room 온도저감 연구)

  • Jung, Young In;Choi, Sang Min
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.3
    • /
    • pp.425-435
    • /
    • 2019
  • Purpose: The purpose of this study was to resolve the Naval ship's Local Operation Panel(LOP) malfunction problems which caused by overheating in summer season and dispatching to equatorial regions. Methods: Instead of using dual type heat insulation materials(consist with ceramic wool and glass wool), aerogel heat insulation materials were used for decreasing heat emissions from gas-turbine heat waste steam pipes passing water-jet- room. Experiment and Computational analysis of heat flow were conducted to analyze the internal room temperature changes. Results: The results of this study are as follows; The aerogel heat insulation materials suppress heat emission more efficiently than dual type insulation materials. The cold surface temperature of insulation was far more decreased and internal room, LOP surface temperature also showed significant results too. Conclusion: The substituted heat insulation materials appeared remarkable performance in decreasing room temperature that it could be used for suppressing the LOP overheatings and malfunctions.

WEAR BEHAVIOUR OF STEAM GENERATOR TUBES IN ROOM TEMPERATURE WATER

  • Lee, Young-Ho;Kim, Hyung-Kyu;Kim, In-Sup
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.203-204
    • /
    • 2002
  • The wear behaviour of steam generator (SG) tubes (Inconel 600 and 690) against support materials (405 and 409 ferritic stainless steels) has been experimentally studied in room temperature water using reciprocating wear apparatus with tube-an-plate configuration. The results showed that the wear rate of Inconel 690 was lower than that of lnconel 600 with increasing normal loads and sliding amplitudes. Also, plastic deformation layers appear below the surface of both SG tubes, which have a specific thickness and are small compared with their grain size. This means that wear rate of SG tubes in water condition is closely related to the formation and fracture of plastic deformation layers.

  • PDF

High Temperature Wear Behavior of Inconel 690 Steam Generator tube (인코벨 690 증기발생기 세관의 고온 마모 거동)

  • 홍진기;김인섭;김형남;장기상
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.59-62
    • /
    • 2001
  • Flow induced vibration in steam generators has caused dynamic interactions between tubes and contacting materials resulting in fretting wear . Series of experiments have been performed to examine the wear properties of Inconel 690 steam generator tubes in various environmental conditions. For the present study, the test rig was designed to examine the fretting wear and rolling wear properties in high temperature(room temperature - 290。C) water. The test was performed at constant applied load and sliding distance to investigate the effect of test temperature on wear properties of the steam generator tube materials. To investigate the wear mechanism of material, the worn was observed using scanning electron microscopy. The weight loss increase at higher test temperature was caused by the decrease of water viscosity and the mechanical property change of tube material. The mechanical property changes of steam generator tube material, such as decrease of hardness or yield stress in the high temperature tests. From the SEM observation of worn surfaces, the severe wear scars were observed in specimens tested at the higher temperature.

  • PDF

An Influence of Corium Composition Variations on a Spontaneous Steam Explosion in Severe Accidents in a Nuclear Reactor (원자로 노심용융물의 성분비 변화가 증기폭발에 미치는 영향)

  • Kim, Jong-Hwan;Park, Ik-Kyu;Hong, Seong-Wan;Min, Beong-Tae;Song, Jin-Ho;Kim, Hee-Dong
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2041-2046
    • /
    • 2004
  • Recently series of steam explosion experiments have been performed in the TROI facility to identify the influence of corium compositions on the occurrence of a spontaneous steam explosion varying corium melt composition. The compositions of the corium were 0 : 100, 50 : 50, 70 : 30, 80 : 20 and 87 : 13 at weight percent of $UO_2$ to $ZrO_2$, and the mass of the corium was about 10kg. Corium melt at 0 : 100 weight percent (pure zirconia) caused a strong spontaneous steam explosion, and melt at 70 : 30 weight percent(eutectic corium) led to a weak steam spike, while melts at other compositions did not result in spontaneous steam explosions, when they came into contact with 67cm deep water pool at room temperature. It seems that the explosivity of pure zirconia is stronger than that of corium at other compositions and a steam explosion is not likely to occur with corium melts at non-eutectic compositions which are included in mushy zone region.

  • PDF

Experimental studies on the fretting wear of domestic steam generator tubes (국내 증기발생기 전열관 마열에 대한 실험적 연구)

  • Lee, Yeong-Ho;Kim, Hyeong-Gyu;Kim, In-Seop
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.304-309
    • /
    • 2002
  • Fretting wear test in room temperature water was performed to evaluate the wear coefficient of Inconel 600,690 (Pressurized Water Reactor, PWR) and Alloy 800 (CANadian DeuteriumUranium, CANDU) steam generator (SG) tubes against ferritic and martensitic stainless steels. The main focus is to compare the wear behaviors between Alloy 800 and Inconel alloys. Test conditions are $10{\sim}30N$ of normal load, $200{\sim}450{\mu}m$ of sliding amplitude and 30Hz of frequency. The result indicated that the wear rate of Alloy 800 was higher than those of Inconel 690 at various test condition such as normal loads, sliding amplitudes etc. From the results of SEM observation, there was little evidence of plastic deformation layer that were dominantly formed on the worn surfaces of Inconel 690. Also, wear particles in Alloy 800 were released from contacting asperities deformed by severe plastic flow during fretting wear. Main cause of wear rate between Alloy 800 and Inconel 690 may be due to the difference of hardness between martensitic and ferritic stainless steel. The wear rate and wear mechanism of two tubes in room temperature water are discussed.

  • PDF

A Study on Noise Control and Verification of High Pressure Steam System Using Experimental Method (실험적 방법을 이용한 고압증기 시스템의 방음설계 및 검증에 관한 연구)

  • Seok, H.I.;Lee, D.K.;Jeong, T.S.;Heo, J.H.
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2011.09a
    • /
    • pp.112-116
    • /
    • 2011
  • The noise analysis is usually carried out in the early structure design stage for the main areas in a vessel such as an accommodation, an engine room, HVAC System and etc. If the analysis results are higher than the noise limits based on guideline, appropriate countermeasures are established to reduce noise levels and applied to the vessel. But excessive noise induced the main or auxiliary equipment and high pressure steam system is very difficult to check in the initial design stage, and local noise problems frequently appear in actual vessels. This paper deals with excessive noise of the engine control room on LNG carrier. It includes the cause analysis of excessive noise, the countermeasure, and verification. Also, it proves suitability of the countermeasure through the on-board test.

  • PDF