• 제목/요약/키워드: steady-state current

검색결과 815건 처리시간 0.035초

The Effect of Transformer Leakage Inductance on the Steady State Performance of Push-pull based Converter with Continuous Current

  • Chen, Qian;Zheng, Trillion Q.;Li, Yan;Shao, Tiancong
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.349-361
    • /
    • 2013
  • As a result of the advantages such as high efficiency, continuous current and high stability margin, push-pull converter with continuous current (PPCWCC) is competitive for battery discharge regulator (BDR) which plays an important role in power conditioning unit (PCU). Leakage inductance yields current spike in low-ripple current of PPCWCCs. The operating modes are added due to leakage inductance. Therefore the steady state performance is affected, which is embodied in the spike of low-ripple current. PPCWCCs which are suitable for BDR can be separated into three types by current spike characteristics. Three representative topologies IIs1, IIcb2 and Is3 are analyzed in order to investigate the factors on the magnitude and duration of spike. Equivalent current sampling method (ECSM) which eliminates the sampling time delay and achieves excellent dynamic performance is adopted to prevent the spike disturbance on current sampling. However, ECSM reduces the sampling accuracy and telemetry accuracy due to neglecting the spike. In this paper, ECSM used in PPCWCCs is summarized. The current sampling error is analyzed in quality and quantity, which provides the foundation for offsetting and enhancing the telemetry accuracy. Finally, current sampling error rate of three topologies is compared by experiment results, which verify the theoretical analysis.

분산전원용 계통연계형 PCS의 전류제어기 비교 (Comparison of Current Controllers of Grid-connected PCS for Distributed Resources)

  • 박종형;조택현;김흥근;전태원;노의철;차헌녕
    • 전력전자학회논문지
    • /
    • 제17권3호
    • /
    • pp.274-280
    • /
    • 2012
  • In this paper, three current controllers for a grid-connected PCS using an LCL filter are compared and analyzed. Current controllers discussed in this paper are linear controllers such as PI (proportional-integral), PR (proportional-resonant), and DB (deadbeat) controller. Both transient and steady state responses of each controller are compared through both simulation and experiment. Although the DB controller has the fastest transient response and the lowest THD in the steady state, the DB controller has two cycles delay of current response in the steady state and has the stability problem which can be occurred due to variation of the system parameters. On the one hand the responses of PR controller are not much different from that of DB controller but the other hand that are not only strong to noise of grid current but also have smaller THD than PI controller. Considering the response time and stability issue of three controllers, the PR controller has the best performance among three controllers and thus can be strongly recommended as a current controller for a grid-connected PCS.

입력전류추정에 의한 전압형 PWM 컨버터의 정현추종제어 (Sinusoidal Tracking Control of Voltage Source PWM Converter by Input Current Estimation)

  • 허태원;박지호;신동률;김춘삼;우정인
    • 조명전기설비학회논문지
    • /
    • 제14권4호
    • /
    • pp.39-47
    • /
    • 2000
  • 본 논문에서는 입력전류 추정에 의한 전밥형 PWM 컨버터의 정상상태 및 과도상태 특성을 개선하기 위하여 정현추종제어기를 제안한다. 그리고, 입력전류의 추정방법과 제어기의 구성에 대해서 논의된다. DC 출력전압은 PI제어기로 제어되며, AC 입력전류를 직접추총 제어하는 정현추종 전류제어기가 입력전류 제어기로 사용된다. 정현추종 전류제아기는 좌표변환 알고리즘 없이 사용가능 하므로 제어계를 간소화 할 수 있다. 입력전류 제어계의 전달함수로부터 입력전류의 정상상태오차가 0이 되고, 입력전압의 동에 대해서도 제안한 제어계는 영향을 받지 않는다는 것을 알 수 있다. 아울러 제안한 방법에 대한 타당성이 시뮬레이션 및 부하, 입력 전압 변동에 대한 실험결과로부터 확인할 수 있다.

  • PDF

22.9kV/630A 저항형 초전도 한류기용 전도-냉각 황동 전류인입선 제작 및 특성 실험 (Fabrication and Characteristic Test of Conduction-Cooled Brass Current Leads for a 22.9kV/630A Resistive Superconducting Fault Current Limiter System)

  • 송정빈;김주형;권나영;김용우;김호민;심정욱;이방욱;김혜림;현옥배;이해근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.46-51
    • /
    • 2007
  • The 22.9kV/630A superconducting fault current limiter (SFCL) is developed by the KEPRI-LSIS collaboration group. This resistive SFCL uses three pairs of conduction-cooled current leads. When the SFCL system is in the fault mode. the current flows 20 times more than the steady state. Therefore. it is important that the current lead is designed to have the thermal stability in order to minimize the heat input of the cold-end. This paper presents the design and performance results of a pair of conduction-cooled brass current leads considering both cases that the SFCL system operates at the steady state and the fault current.

3상 승압형 컨버터에 의한 전도노이즈 감소 (Conducted Noise Reduction in Three-Phase Boost Converter using Random)

  • 정동효;김상남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.79-82
    • /
    • 2003
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. In the switching-mode power converter, the output voltage is generally controlled by varying the duty ratio of main switch. When a converter operates in steady state, duty ratio of the converter is kept constant. So the power of switching noise is concentrated in specific frequencies. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.

  • PDF

Parameter Estimation of Three-Phase Induction Motor by Using Genetic Algorithm

  • Jangjit, Seesak;Laohachai, Panthep
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권3호
    • /
    • pp.360-364
    • /
    • 2009
  • This paper suggests the techniques in determining the values of the steady-state equivalent circuit parameters of a three-phase induction machine using genetic algorithm. The parameter estimation procedure is based on the steady-state phase current versus slip and input power versus slip characteristics. The propose estimation algorithm is of non-linear kind based on selection in genetic algorithm. The machine parameters are obtained as the solution of a minimization of objective function by genetic algorithm. Simulation shows good performance of the propose procedures.

이중여자 유도발전 풍력시스템의 정상상태 특성 해석 (Analysis of Steady State Characteristics of Doubly-Fed Induction Generator in Wind Turbine system)

  • 장보경;노경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.460_461
    • /
    • 2009
  • This paper analyzes the steady state characteristics for variable speed wind power system with doubly-fed induction generator(DFIG). This paper explains the equivalent circuit and phasor diagram of DFIG for different operating conditions. It also simulates the torque-slip characteristics with respect to changes of different parameters. Simulation results show the torque-slip characteristics, stator power factor-rotor voltage and stator current-rotor voltage.

  • PDF

해남-전주 HVDC 계통의 정상상태 및 지락 고장시 제어특성 (The Control Characteristics of Haenam-Cheju HVDC system at Ground Fault and Steady State)

  • 곽주식;우정욱;심응보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1331-1333
    • /
    • 1999
  • In Haenam-Cheju HVDC link several modes of operations and controls are provided, which are constant frequency control, constant power control and constant current control. This paper describes basic control action of converters under three control modes and shows EMTDC simulation results at ground fault and steady state respectively.

  • PDF

전류원 인버터로 구동되는 유도전동기의 맥동토오 (Steady-State Torque Pulsations in Current Source Inverter Fed Induction Motor Drives)

  • 신휘범;윤명중
    • 대한전기학회논문지
    • /
    • 제37권4호
    • /
    • pp.197-204
    • /
    • 1988
  • A simple method that estimates the torque fluctuations in induction motor driven by CSI under steady state condition is presented and that uses the phasor diagram from the modified singlephase equivalent circuit. This method is also applied to evaluate the PWM and programmed do link modulation techniques for reducing the torque pulsations. The simplified calculations are compared with the exact digital solutions from machine D-Q equation. It is noted that the torque pulsations in induction motor driven by CSI are dependent upon the load condition unlike VSI.

  • PDF

고온ㆍ고압 아크 플라즈마 하에서의 정상상태 노즐용삭 해석 기술 (Steady State Analysis of Nozzle Ablation Under High Temperature and High Pressure Arc Plasma)

  • 이병윤;송기동;정진교;박경엽
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.395-399
    • /
    • 2003
  • In this paper, physical phenomena which are related to the high temperature and high pressure arc plasma generated during the fault current interruption by SF6 gas circuit breakers are reviewed. In particular, in order to analyze nozzle ablation induced by the heats transferred to the surface of the poly-tetrafluoroethylene(PTFE) nozzle through arc radiation, a governing equation for the calculation of PTFE concentration is added to the governing equations for SF6 arc Plasma analysis. The proposed method is applied to the steady state analysis of $SF_6$ arc plasma generated by direct current taking account of the nozzle ablation and the results are presented.