• Title/Summary/Keyword: steady state distribution

Search Result 488, Processing Time 0.029 seconds

Analysis of Contact Stress with Partial Slip in Wheel-rail Rolling Contact (차륜-레일 구름접촉 시 슬립율에 따른 접촉응력의 변화 해석)

  • Lee, Dong-Hyong;Seo, Jung-Won;Kwon, Seok-Jin;Choi, Ha-Yong;Kim, Chul-Jae
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.643-648
    • /
    • 2011
  • Fatigue crack in most rails take place by rolling contact between wheel and rail in railway industry. Therefore, it is critical to understand the rolling contact phenomena, especially for the three-dimensional situation. In this paper the steady-state rolling contact problem of KTX wheel and rail (UIC60) has been studied with three-dimensional finite element analysis. The variation of contact pressure and contact stresses on rolling contact surface were obtained using the finite element method. The three-dimensional distribution of contact stresses on the contact surface are investigated. Results show that the distribution of shear stress and contact stress (von Mises) on the contact surface varies rapidly as a result of the variation of stick-slip region. The contact stress at the leading edge is greater than at the trailing edge because of stick and slip phenomena.

  • PDF

Estimation of Temperature Distribution on Wafer Surface in Rapid Thermal Processing Systems (고속 열처리공정 시스템에서의 웨이퍼 상의 온도분포 추정)

  • Yi, Seok-Joo;Sim, Young-Tae;Koh, Taek-Beom;Woo, Kwang-Bang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.4
    • /
    • pp.481-488
    • /
    • 1999
  • A thermal model based on the chamber geometry of the industry-standard AST SHS200MA rapid thermal processing system has been developed for the study of thermal uniformity and process repeatability thermal model combines radiation energy transfer directly from the tungsten-halogen lamps and the steady-state thermal conducting equations. Because of the difficulties of solving partial differential equation, calculation of wafer temperature was performed by using finite-difference approximation. The proposed thermal model was verified via titanium silicidation experiments. As a result, we can conclude that the thermal model show good estimation of wafer surface temperature distribution.

  • PDF

Shear Angle Variation Depending on Chip-Tool Friction in Orthogonal Cutting (二次元 切削時 칩-工具 마찰상태에 따른 剪斷角 변화)

  • 이영문;송지복
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.252-261
    • /
    • 1988
  • Through the careful interpretation of the results of the cutting tests carried out in this study, it is found that under the cutting conditions when the internal shear of the chips take place the cutting can be treated essentially as a steady state problem. A new shear angle equation has been developed employing the conditions of force and moment equilibrium about the tool edge and the stress distribution model suggested by Zorev.The equation contains the chip-tool contact length C and stress distribution index n as important parameters.

A Continuous Review(s, S) Inventory Model in which Depletion is Due to Demand and Loss of Units

  • Choi, Jin-Yeong;Kim, Man-Sik
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.11 no.1
    • /
    • pp.33-39
    • /
    • 1985
  • A stochastic model for an inventory system in which depletion of stock takes place due to random demand as well as random loss of items is studied under the assumption that the intervals between successive unit demands, as well as those between successive unit losses are independently and identically distributed random variables having negative exponential distribution with respective parameters. We have derived the steady state probability distribution of the stock level assuming instantaneous delivery of order under (s, S) inventory policy. Also we have derived total expected cost expression and the necessary conditions to be satisfied for an optimal solution.

  • PDF

Effect of RPM and Temperature on the CSD in the CMSMPR Calcium Carbonate Crystallizer (연속식 탄산칼슘 결정화기에서 교반속도와 온도가 입도분포에 미치는 영향)

  • Han, Hyun Kak;Jeong, Ok Hee;Lim, Mi Hee;Kim, Jin A
    • Korean Chemical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.289-293
    • /
    • 2006
  • In the CMSMPR (continuous mixed suspension mixed product removal)system, the effect of temperature and RPM on the CSD (crystal size distribution) in the calcium carbonate process was investigated. In the steady state operation, the change of solution pH was small. At the low temperature and below 300 RPM, volume mean size change of calcium carbonate was stable and CSD was narrow. In the SEM view, calcite and aragonite was obtained.

Development of a Subchannel Analysis Code MATRA Applicable to PWRs and ALWRs

  • Yoo, Yeon-Jong;Hwang, Dae-Hyun;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.314-327
    • /
    • 1999
  • A subchannel analysis code MATRA applicable to PWRs and ALWRs has been developed to be run on an IBM PC or HP WS based on the existing CDC CYBER mainframe version of COBRA-Rf-1. This MATRA code is a thermal-hydraulic analysis code based on the subchannel approach for calculating the enthalpy and How distribution in fuel assemblies and reactor cores for both steady-state and transient conditions. HATRA has been provided with an improved structure, various functions, and models to give more convenient user environment and to enhance the code accuracy. Among them, the pressure drop model has been improved to be applied to non-square-lattice rod arrays, and the models for the lateral transport between adjacent subchannels have been improved to enhance the accuracy in predicting two-phase flow phenomena. The predictions of MATRA were compared with the experimental data on the flow and enthalpy distribution in some sample rod-bundle cases to evaluate the performance of MATRA. All the results revealed that the predictions of MATRA were better than those of COBRA-IV-I.

  • PDF

An analytical study on the Effect of High impedance Transformer to reduce Distribution Fault Current (변압기 임피던스 증가에 의한 배전계통의 고장전류 저감방안의 영향분석)

  • Lee, Hyun-Chul;Lee, Geun-Joon;Hyun, Ok-Bae;Hwang, Si-Dol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.239_240
    • /
    • 2009
  • This paper presents the brief analytical study on 돋 effects of higher impedance transformer(HIT) to reduce distribution system fault current. With the increase of source and load capacity of power system, fault current of D/L is much more increased and, conventional protection equipment-such as sectionalizer and recloser, have to be replaced higher switching capacity. However, this replacements needs a lot of budget to utility. Increase of transformer impedance is can be a countermeasure in practical basis. This paper compares the voltage and fault current magnitude of both cases -%Zt=20% and %Zt2=33.3%(transformer capacity is 75/100MVA). The simulation results show that the steady state voltage of HIT is dropped 5~6% more in peak load, and fault current was decreased about 5kA by high impedance on transformer.

  • PDF

Effects of Reburning on Heat Transfer Characteristics and $NO_x$ Reduction (재연소가 열전달 특성과 $NO_x$ 감소에 미치는 영향)

  • Lee, Chang-Yeop;Baek, Seung-Wook
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.2
    • /
    • pp.18-25
    • /
    • 2005
  • An experimental study has been conducted to evaluate the effects of reburning on $NO_x$ reduction and also to examine heat transfer characteristics from LPG flame. Experiments were performed in flames stabilized by a co-flow swirl burner, which was mounted at the bottom of the furnace. Tests were conducted using LPG gas as main fuel and also as reburn fuel. The effects of reburn fuel fraction and injecting location of reburn fuel are studied. The paper reports data on flue gas emissions, temperature distribution in furnace and various heat fluxes at the wall for a wide range of experimental conditions. In a steady state, the total as well as radiative heat flux from the flame to the wall of furnace has been measured using a heat flux meter. Temperature distribution and emission formation in furnace have been also measured and compared.

  • PDF

Mitigating Cache Pollution Attack in Information Centric Mobile Internet

  • Chen, Jia;Yue, Liang;Chen, Jing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.11
    • /
    • pp.5673-5691
    • /
    • 2019
  • Information centric mobile network can significantly improve the data retrieving efficiency by caching contents at mobile edge. However, the cache pollution attack can affect the data obtaining process severely by requiring unpopular contents deliberately. To tackle the problem, we design an algorithm of mitigating cache pollution attacks in information centric mobile network. Particularly, the content popularity distribution statistic is proposed to detect abnormal behavior. Then a probabilistic caching strategy based on abnormal behavior is applied to dynamically maintain the steady-state distribution for content visiting probability and achieve the purpose of defense. The experimental results show that the proposed scheme can achieve higher request hit ratio and smaller latency for false locality content pollution attack than the CacheShield approach and the baseline approach where no mitigation approach is applied.

A new model for transient heat transfer model on external steel elements

  • Chica, J.A.;Morente, F.
    • Steel and Composite Structures
    • /
    • v.8 no.3
    • /
    • pp.201-216
    • /
    • 2008
  • The Eurocode system provides limited information regarding the structural fire design of external steel structures. Eurocode 1 provides thermal action for external member but only in steady-state conditions. On the other hand, Eurocode 3 provides a methodology to determine heat transfer to external steelwork, but there is no distinction in cross section shapes and, in addition, the calculated temperature distribution is assumed to be uniform in the cross section. This paper presents the results of a research carried out to develop a new transient heat transfer model for external steel elements to improve the current approach of the Eurocodes. This research was carried out as part of the project EXFIRE "Development of design rules for the fire behaviour of external steel structures", funded by the European Research Programme of the Research Fund for Coal and Steel (RFCS).