• 제목/요약/키워드: steady state condition

검색결과 678건 처리시간 0.112초

관내 사각지주 후류의 유동현상에 대한 수치해석 (Numerical Analysis on Flow Phenomena of the Wake behind the Rectangular Obstacle in the Channel)

  • 민영위;김연수;김유곤
    • 한국전산유체공학회지
    • /
    • 제6권2호
    • /
    • pp.22-31
    • /
    • 2001
  • The two-dimensional unsteady incompressible viscous flow behind rectangular bluff bodies between two parallel plates was analyzed numerically. The steady state flow and the vortex flow behind rectangular bluff bodies in the channel were investigated for two regimes i.e., the laminar(Re = 100, 300, 500) and the turbulent flows(Re = 10⁴∼10/sup 6/). The vortex shedding was generated by a physical disturbance(6%) numerically imposed at the rear of the bluff bodies for a short time. It was observed that the perturbed flow became periodic after a transient period. And in the case of unsteady inflow, the sinusoidal pulsatile flow was applied as the inlet condition in the turbulent flow of Reynolds number of 1.0×10/sup 5/. FLUENT code was employed to solve the problems. The power-law scheme was used to get stable linearized equations and the PISO algorithm was applied to finding the solution of them.

  • PDF

다공층의 증발냉각 열전달에 관한 해석적 연구 (Analytical Study of heat Transfer in Evaporative Cooling of a Porous Layer)

  • 김홍제;이진호
    • 대한기계학회논문집
    • /
    • 제16권1호
    • /
    • pp.104-111
    • /
    • 1992
  • 본 연구에서는 외부 열입력(external heat input)의 조건하에서 증발분출냉각 시스템에서 나타나는 3개의 영역, 즉 증기, 증발 및 액체영역을 고려한 이론해석을 행 함으로써 증발분출냉각 시스템의 열전달 특성을 정성적으로 조사하고자 하였다.

몬테카를로 시뮬레이션을 이용한 증기 터빈블레이드재의 확률론적 해석 (A Stochastic Analysis in Steam Turbine Blade Steel Using Monte Carlo Simulation)

  • 김철수;정화영;강명수;김정규
    • 대한기계학회논문집A
    • /
    • 제26권11호
    • /
    • pp.2421-2428
    • /
    • 2002
  • In this study, the failure probability of the degraded LP turbine blade steel was performed using the Monte Carlo simulation to apply variation of applied stress and strength. For this purpose, applied stress under the service condition of steady state was obtained by theoretical stress analysis and the maximum Von-Mises stress was 219MPa. The fatigue strength under rotating-bending load was evaluated by the staircase method. Furthermore, 3-parameter Weibull distribution was found to be most appropriate among assumed distributions when the probabilistic distributions of tensile and fatigue strength were determined by the proposed analysis. The failure probability with various loading conditions was derived from the strength-stress interference model and the characteristic factor of safety was also estimated.

LPCVD 공정중 웨이퍼의 온도장 해석 (Thermal analysis of the wafers in LPCVD process)

  • 김일경;정민철;유승일;채승기;김우승;남기흠
    • 대한기계학회논문집B
    • /
    • 제22권5호
    • /
    • pp.651-660
    • /
    • 1998
  • In the LPCVD reactor the temperature variations within the wafer load are the most important factor to maintain the thickness of the materials deposited on the surface of the wafer constant and to affect the deformation of each wafer. In this study the temporal variations of radial and axial temperature nonuniformities of each wafer in the LPCVD reactor are numerically estimated by assuming diffuse reflection. To verify the validity of the present numerical results, the present results obtained from the transient analysis are compared with those of Badgwell's work in which a steady-state condition was assumed. The main objective of this work is to determine the temporal variations of the temperature of each wafer in the LPCVD process since the wafers experience severe change in temperature in the early stage of the process.

토크 컨버터의 1차원 성능 모델을 이용한 유동 각도 보정 계수에 관한 연구 (A Study on the Correction Factor of Flow Angel by using the One Dimentional Performance Model of Torque Converter)

  • 임원식
    • 대한기계학회논문집A
    • /
    • 제24권2호
    • /
    • pp.506-517
    • /
    • 2000
  • One dimensional performance model has been used for the design of torque converter. The model is based on the concept of constant mean flow path and constant flow angle. These constant-assumed para meters make the design procedure to be simple. In practice, some parameters are usually replaced with geometric raw data and, the constant experiential correction factors have been used to minimize the design error. These factors have no definite physical meaning and so they cannot be applied confidently to the other design condition. In this study, the detail dynamic model of torque converter is presented to establish the theoretical background of correction factors. To verify the validity of theoretical model, steady state performance test was carried out on the several input speed. The oil temperature effect on the performance is analysed and adjusted. The constant equivalent flow angles are determined at a part of performance region by comparing the theoretical model and the test data. The sensitivity of correction factors to the input speeds are studied and the change of torus flow is presented.

Dimethylsulfide as a Malordorous Component of a Waste Reclamation Site

  • Kim, Ki-Hyun;Lee, Gangwoong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제15권E호
    • /
    • pp.39-43
    • /
    • 1999
  • To help idntify the potential sources of volatile organic sulfur compounds within the continental environment, we have conducted preliminary measurements of dimethylsulfide(DMS) during field campains held from three reference sites. These sampling sites were located within a waste reclamation facility in Won Ju City, Kang Won Province. The results of our measurements showed that DMS levels spanned over 1 to 55 pptv with a mean and 1 standard deviation(1SD) of 12 and 18 pptv(N=13). In a comparison of the data derived from the strongest sources, i.e., oceanic environment, the DMS levels in thre reclamation facility were jpronouncingly low with high day-to-night concentration ratios. It was noted that a significant difference in DMS levels between daytime and nighttime periods was mainly driven by a few exceptional data measured during daytime. Despite limitations of our measurement data in deriving meaningful interpretations of spatiotemporal distributions of DMS in inland facilities, the existence of extraordinary trends, i.e., especially "lower-than-expectedL" DMS values, can be explained in terms of mixed effects of several factors. Most importantly, we can infer that the rates of DMS production and of its destruction in the study site are at or near steady-state condition. Another possibility is that DMS is not adequate enough to explain the generally malordorous environment of reclamation sites, of particular in Won Ju area.n Ju area.

  • PDF

초음파 발생 미스트를 이용한 TiO2 광촉매 시스템에서의 가스상 톨루엔 제거 (Removal of Gaseous Toluene Using a TiO2 Photocatalytic System with Mist Generated by Ultrasonic Atomization)

  • 최민석;한세현;장성찬;정용원
    • 한국대기환경학회지
    • /
    • 제25권3호
    • /
    • pp.211-218
    • /
    • 2009
  • Feasibility study of using $Ti0_2$ mist generated by ultrasonic atomization for photocatalytic degradation of gaseous toluene was attempted in this study. For this, the photocatalytic reactor consisting of mist generator and photo-reactor was designed. Most of experimental results showed that steady state reached about 30 minutes after the start of experiments. The effects of $Ti0_2$ concentration, toluene concentration, and UV wavelength on toluene removal ratio were investigated. It was found that the highest removal efficiency was obtained when $Ti0_2$ concentration was 0.6 g/L in slurry. At this condition, it was found that the toluene removal efficiency increased as toluene concentration in feed decreased. In order to investigate the effect of UV wavelength, experiments were carried out using three UV lamps with different UV wavelength. The results showed that the highest removal efficiency was achieved when the lamp with the shortest wavelength were employed.

생물학적 회분식 인 제거 공정에서 pH 영향과 미생물 군집의 변화 (Influence of Different Operational pH Conditions to Microbial Community in Biological Sequencing Batch Phosphorus Removal Process)

  • 안조환
    • 한국물환경학회지
    • /
    • 제29권4호
    • /
    • pp.459-465
    • /
    • 2013
  • A sequencing batch reactor was operated under different pH conditions to see the influence of pH to microbial community in enhanced biological phosphorus removal (EBPR) systems. Long term influences of different steady-state pH conditions on the microbial community composition were evaluated by polymerase chain reaction (PCR)-denaturing gradient gel electrophoresis (DGGE) and fluorescence in situ hybridization (FISH). The shift in populations from polyphosphate-accumulating organisms (PAOs) to Alphaproteobacteria was observed when pH was changed from 7.5 to 7.0. Alphaproteobacteria with the typical morphological traits of tetrad-forming organisms (TFOs) eventually became dominant members. The alphaproteobacterial TFOs were the phenotype expected for glycogen-accumulating organisms (GAOs), which accumulate large amount of glycogen into the cell. The results strongly suggested that low operational pH condition encourages the appearance of the GAOs in EBPR process, significantly reducing the EBPR capacity.

접착형 박막 측온게이지식 열류센서의 개발에 관한 연구

  • 한응교;박두원;최규철;노병옥;이명호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1991년도 추계학술대회 논문집
    • /
    • pp.80-86
    • /
    • 1991
  • In this study an the development of the heat flux sensor with thermocouple, the heat-treated adhesive type film nickel gauge(Ni-Gauge) for measuring temperature was used. and this Ni-Gauge is not only comparable for platinum gauge(Pt-Gauge) in linearity, but also economically cheap. And from this viewpoint. numerical analysis is essential to investigate charateristics of sensor, since this analysis is capable of simulating precise boudary condition and practical conditions and so on. By the way. there are many types of heat flux sensor. of which adhesive type flux sensor is common, in the study this type of heat flux sensor was chogen. and analysis of the sensor is considered as a kind of open cavity figure. performed by SIMPLER algorithm. As a result. through temperature distributial of the sensor by numerical analysis in steady and unsteady state, the dracteristics of the acdhesive type heat flux sensor(lst heat flux sensor) acooodinge to heat flux, that is, outvoltage, sensitivity. and responsibilty could be evaluated. in addition, time of improved heat flux sensor(2nd heat flux sensor) could be predicted fran the reflectian of proper operating temperature(l50 $^{\circ}C$)of theNi-Gauge.

  • PDF

퍼지 PI 제어기를 이용한 태양광 발전시스템의 MPPT 제어 (The MPPT Control of Photovoltaic System using the Fuzzy PI Controller)

  • 고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제28권2호
    • /
    • pp.9-18
    • /
    • 2014
  • This paper proposes the fuzzy PI controller for maximum power point tracking(MPPT) control of photovoltaic system. The output characteristics of the solar cell are a nonlinear and affected by a temperature, the solar radiation. The MPPT control is a very important technique in order to increase an output and efficiency of the photovoltaic system. The conventional perturbation and observation(PO) and incremental conductance(IC) are the method which finding maximum power point(MPP) by the continued self-excitation vibration, and uses the fixed step size. If the fixed step size is a large, the tracking speed of maximum power point is faster, but the tracking accuracy in the steady state is decreased. On the contrary, when the fixed step size is a small, the tracking accuracy is increased and the tracking speed is slower. Therefore, this paper proposes the MPPT control using the fuzzy PI controller that can be improve a MPPT control performance. The fuzzy PI controller is adjusted a input of PI controller by fuzzy control and compensated a cumulative error of fuzzy control by PI controller. The fuzzy PI MPPT control is compared to conventional PO and IC MPPT method for various temperature and radiation condition. This paper proves the validity of the fuzzy PI controller using these results.