• 제목/요약/키워드: steady state condition

검색결과 678건 처리시간 0.031초

Numerical Analysis of Laminar Natural Convection Heat Transfer around Two Vertical Fins by a Spectral Finite Difference Method

  • Haehwan SONG;MOCHIMARU Yoshihiro
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.56-57
    • /
    • 2003
  • A numerical solution is presented for the natural convection heat transfer from two vertical fins using a spectral finite difference method. Virtual distant boundary conditions for two bodies that are compatible with plume behavior and with an overall continuity condition are introduced. A boundary-fitted coordinate system is formed. Streamlines, isotherms, mean Nusselt numbers and drag & lift coefficients are presented for a variety of dimensionless parameters such as a Grashof number and a Prandtl number at a steady-state. Extensive effectiveness of a spectral finite difference method was established.

  • PDF

직교 이방성 탄성체에 접합된 압전 재료의 균열 전파 거동 (Crack Propagation in a Piezoelectric Layer Bonded between Two Orthotropic Layers)

  • 김철곤;권순만;이강용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.22-26
    • /
    • 2001
  • In this paper, we examine the steady state dynamic electromechanical behavior of an eccentric Yoffe crack in a piezoelectric ceramic layer bonded between two orthotropic elastic layers under the combined anti-plane mechanical shear and in-plane electrical loadings. We adopted permeable crack face condition. Numerical values on the dynamic energy release rate are obtained. The initial crack propagation orientation for PZT-5H piezoceramic is also predicted by maximum energy release rate criterion.

  • PDF

열에너지를 고려한 파괴인성치 고찰 (Evaluation for Fracture Toughness with Considering the Thermal Energy)

  • 박재실;김정표;석창성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.9-15
    • /
    • 2001
  • In the case of a crack propagation, a portion of the work of inelastic deformation near the crack tip is dissipated as heat. In order to understand the thermal effect on fracture toughness, tensile test was carried out using thermocouples to monitor the variation of temperature with SA516 Gr70. The experimental results show that the temperature of specimen was increased $3.6^{\circ}C$ at static load condition. And the thermal effect was investigated connected with the steady-state stress in the vicinity of a crack propagation in the elastic-plastic C-T specimen theoretically. And fracture toughness, the energy to make crack surfaces, presented correctively. The fracture toughness with considering heat at the blunting of the crack tip ws lower about 19.3% than that of ignoring heat. So, it is resonable to apply the fracture toughness with considering thermal energy and it would be good explanation for constraint effect depending on the configuration in the presence of excessive plasticity.

  • PDF

추정된 쿨롱 마찰을 보상한 볼-스크류 시스템의 위치제어 (Position Control of Ball-Screw Systems with Compensation of Estimated Coulomb Friction)

  • 김한메;최정주;이영진;김종식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.893-898
    • /
    • 2003
  • Coulomb friction is an important factor for precise position tracking control systems. The control systems with friction causes the steady state error because of being sensitive to the change of system condition and highly nonlinear characteristics. To overcome these problems, we use an estimation scheme of Coulomb friction to experiment for it's compensating. The estimated factor for Coulomb friction is used as a feed-forward compensator to improve the tracking performance of ball-screw systems. The tracking performance was improved by compensating the estimated friction torque in the feed-forward term. And, the sliding mode control which is derived from the Lyapunov stability theorem is applied for robust stability and reducing chattering. The experimental results show that the sliding mode controller with adaptive friction compensator has a good tracking performance compared with the friction uncompensated controller.

  • PDF

구조 해석과 유동 해석을 통한 연료전지 공기판 설계 (Structural and Flow Analysis for Designing Air Plate of a Fuel Cell)

  • 박정선;양지혜;이원용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.585-590
    • /
    • 2003
  • The distributions of mass flow rate and pressure are major factors to deside the performance of a proton exchange membrane fuel cell (PEMFC). These factors are affected by channel configuration of air plate. In this paper. structural analysis is performed to investigate deformation of porous media. Two kind of models are suggest for flow analyses. Deformed porous media and undeformed porous media are considered for air plate model. The Numerical flow analysis results with deformed porous media and undeformed porous media had some discrepancy in pressure distribution. The pressure and velocity in a working condition are numerically calculated to predict the performance of the air plates. Distributions of the parameters in the PEMFC are analyzed numerically under steady-state conditions.

  • PDF

Electrorheological characteristics of poly(o-ethoxy)aniline nanocomposite

  • Sung Jun Hee;Choi Hyoung Jin
    • Korea-Australia Rheology Journal
    • /
    • 제16권4호
    • /
    • pp.193-199
    • /
    • 2004
  • Poly(o-ethoxy)aniline (PEOA)/organoclay nanocomposite was prepared via a solvent intercalation using chloroform as a cosolvent with organically modified montmorillonite (OMMT) clay. The PEOA initially synthesized from a chemical oxidation polymerization in an acidic condition at pH = 1 was intercalated into interlayers of the clay with $25\;wt{\%}$ clay content. Electrical conductivity of the PEOA/OMMT nano­composite was found to be controlled via the intercalating process. The synthesized PEOA/OMMT nano­composite was characterized via an XRD and a TGA, and then adopted as an electrorheological (ER) material. The PEOA/OMMT synthesized with controllable electrical conductivity without a dedoping pro­cess was found to show typical ER characteristics possessing a yield stress from both steady state and dynamic measurements under an applied electric field.

작동 조건 변화에 따른 풍력발전 시스템의 동적 특성 해석 (Dynamic Characteristic Analysis of a Wind Turbine Depending on Varying Operational Conditions)

  • 남윤수;윤태준;유능수
    • 대한기계학회논문집A
    • /
    • 제33권1호
    • /
    • pp.42-48
    • /
    • 2009
  • A design methodology for control strategy and control structure gives a direct impact on wind turbine's performance and life cycle. A baseline control law which is a variable rotor speed and variable pitch control strategy is introduced, and a mathematic performance model of a wind turbine dynamics is derived. By using a numeric optimization algorithm, the steady state operating conditions of wind turbines are identified. Because aerodynamic interaction of winds with rotor blades is basically nonlinear, a linearization procedure is applied to analyze wind turbine dynamic variations for whole operating conditions. It turns out the wind turbine dynamics vary much depending on its operating condition.

여러 형상의 대칭적인 핀의 성능 해석 (Performance Analysis on the Various Shapes of Symmetric Fins)

  • 강형석
    • 산업기술연구
    • /
    • 제16권
    • /
    • pp.97-104
    • /
    • 1996
  • A comparison of the fin effectiveness, thermal resistance, and fin efficiency between the symmetric triangular fin and the symmetric trapezoidal fin which has various slopes of the fin side is made. Also the relation between Biot number and the non-dimensional fin length for equal amount of heat loss from these fins is shown. For these analyses, a forced analytic method is used. In particular, the equation for the heat loss is used simultaneously for both the symmetric triangular fin and the symmetric trapezoidal fins by just adjusting the value of the slope factor. The value of Biot number varies from 0.01 to 1.0 and the non-dimensional fin length varies from 0.01 to 10. For simplicity, the root temperature and fin's surrounding convection coefficients are assumed constant and the condition is assumed to be steady state.

  • PDF

Temperature Distribution of a Low Temperature Heat Pipe with Multiple Heaters for Electronic Cooling

  • Noh, Hong-Koo;Song, Kyu-Sub
    • ETRI Journal
    • /
    • 제20권4호
    • /
    • pp.380-394
    • /
    • 1998
  • A numerical study has been performed to predict the characteristics on the transient operation of the heat pipe with multiple heaters for electronic cooling. The model of the heat pipe was composed of the evaporator section with four heaters, insulated transport section, and the condensor section with a conductor which is cooled with uniform heat flux condition to surrounding. The governing equations and the boundary conditions were solved by the generalized PHOENICS computational code employing the finite volume method. Two test cases are investigated in present study; Case 1 indicates that the 1st and 2nd heaters among four heating sources are heated off, while the 3rd and 4th heaters are heated on. Case 2 is the inverse situation switched from heating location of Case 1. The results show that the transient time to reach the steady state is shorter for Case 1 than for Case 2. Especially, the temperature difference of the heater during switching operation is relatively small compared to the maximum allowable operating temperature difference in electronic system. Hence, it is predicted that the heat pipe in present study operates with thermally good reliability even for switching the heaters.

  • PDF

공냉식 수직평판형 흡수기의 흡수과정에 대한 근사해법 (Approximate Solution of Absorption Process in an Air-Cooled Vertical Plate Absorber)

  • 정은수
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.453-462
    • /
    • 1994
  • An unsteady quasi one-dimensional model of momentum, heat and mass transfer in a falling film of a vertical plate absorber which is cooled by air was developed using the integral method. Energy conservation of the absorber wall is considered in the model. The model can predict absorption rate, film thickness and mean velocity as well as concentration and temperature profiles. Predictions of steady state temperature and concentration profiles for LiBr/water system for constant wall temperature condition are in good agreement with the two-dimensional finite difference method solutions. Effects of operating conditions, such as convective heat transfer coefficient between the cooling air and the absorber wall, cooling air temperature and film thickness at inlet, on absorption rate of water vapor into LiBr/water solution were shown.

  • PDF