• Title/Summary/Keyword: steady state and transient operations

Search Result 25, Processing Time 0.026 seconds

Bidirectional Quasi-Cuk DC/DC Converter with Reduced Voltage Stress on Capacitor and Capability of Changing the Output Polarity

  • Asl, Elias Shokati;Sabahi, Mehran
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1108-1113
    • /
    • 2017
  • In this paper, a bidirectional topology for quasi-Cuk dc/dc converter with capability of zero-voltage and zero-current-switching (ZVZCS) is proposed. The bidirectional quasi-Cuk (BQ-Cuk) converter has different voltage and current transfer ratio, reduced voltage stress on capacitor and capability of changing the output polarity in comparison with conventional bidirectional Cuk converter. In this paper, steady-state analysis of the quasi-Cuk converter with capability of ZVZCS in turn-on is presented. Then, critical inductances for transient from this operation to two new operations are calculated. Next, besides values designing of used elements, maximum and minimum value of their current and voltage are calculated. Finally, experimental results to verify the accuracy of the proposed converter in different operating modes are presented.

Performance Characteristics of a Liquid-Metal Heat Pipe for igh-temperature Solar Thermal Devices Depending on the Operating Conditions (고온 태양열기기용 액체금속 히트파이프의 작동조건에 따른 성능 특성)

  • Park, Cheol-Min;Lee, Jung-Ryun;Boo, Joon-Hong;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.247-250
    • /
    • 2009
  • Sodium heat pipe for high-temperature solar thermal application was manufactured and tested for transient and steady-state operations. Total length of the heat pipe was 650 mm and the outer diameter was 12.7 mm. Thermal performance was compared experimentally for two different cooling methods of the forced and the natural convection cooling in the heat pipe condenser. During the experiment, the maximum temperature was about 1300K, and different cooling methods were applied to the condenser region to charge the operating temperature. The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and operating temperature.

  • PDF

Development of nodal diffusion code RAST-V for Vodo-Vodyanoi Energetichesky reactor analysis

  • Jang, Jaerim;Dzianisau, Siarhei;Lee, Deokjung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3494-3515
    • /
    • 2022
  • This paper presents the development of a nodal diffusion code, RAST-V, and its verification and validation for VVER (vodo-vodyanoi energetichesky reactor) analysis. A VVER analytic solver has been implemented in an in-house nodal diffusion code, RAST-K. The new RAST-K version, RAST-V, uses the triangle-based polynomial expansion nodal method. The RAST-K code provides stand-alone and two-step computation modes for steady-state and transient calculations. An in-house lattice code (STREAM) with updated features for VVER analysis is also utilized in the two-step method for cross-section generation. To assess the calculation capability of the formulated analysis module, various verification and validation studies have been performed with Rostov-II, and X2 multicycles, Novovoronezh-4, and the Atomic Energy Research benchmarks. In comparing the multicycle operation, rod worth, and integrated temperature coefficients, RAST-V is found to agree with measurements with high accuracy which RMS differences of each cycle are within ±47 ppm in multicycle operations, and ±81 pcm of the rod worth of the X2 reactor. Transient calculations were also performed considering two different rod ejection scenarios. The accuracy of RAST-V was observed to be comparable to that of conventional nodal diffusion codes (DYN3D, BIPR8, and PARCS).

Exergy analysis of heat pump in consideration of its dynamic response (동특성을 고려한 열펌프의 엑서지 해석)

  • 장기태;남관우;정상권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.155-164
    • /
    • 1998
  • A multi-type heat pump controls the mass flow rate of the working fluid to cope with variable heat loads when it is under dynamic load condition. This paper describes the exergy analysis associated with the dynamic response of heat pump. First, a basic heat pump cycle is examined at steady state to show the general trends of exergy changes in each process of the cycle. Entropy generation issue in the exchangers is discussed to optimize the heat pump cycle. Second, the performance of the inverter-driven heat pump is compared to that of the conventional one when the heat load is variable. Third, the exergy destruction rate associated with the ON/OFF operations of the heat pump is calculated by simulating the thermodynamic states of the condenser and the evaporator. The inefficiency of the ON/OFF operation during the transient period is quantitatively revealed by the exergy analysis.

  • PDF

A Study on Medium Voltage Power Supply with Enhanced Ignition Characteristics for Plasma Torch

  • Jung, Kyung-Sub;Suh, Yong-Sug
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.242-243
    • /
    • 2010
  • This paper investigates a power supply of medium voltage with enhanced ignition characteristics for plasma torch. Series resonant half-bridge topology is presented to be a suitable ignition circuitry. The ignition circuitry is integrated into the main power conversion system of a multi-phase staggered three-level dc-dc converter with a diode front-end rectifier. The plasma torch rated for 3MW, 2kA and having the physical size of 1m long is selected to be a high enthalpy source in waste disposal system. The steady-state and transient operations of plasma torch are simulated. The parameters of Cassie-Mary arc model are calculated based on 3D magneto-hydrodynamic simulations. Circuit simulation waveform shows that the ripple of arc current can be maintained within ${\pm}10%$ of its rated value under the existence of load disturbance. This power conversion configuration provides high enough ignition voltage around 5KA during ignition phase and high arc stability under the existence of arc disturbance noise resulting in a high-performance plasma torch system.

  • PDF

Computational study of the Nitrogen-16 source term in the ITER vacuum vessel cooling circuit through the coupling of system-level analysis code and CFD

  • M. De Pietri;C. Fiorina;Y. Le Tonqueze;R. Juarez
    • Nuclear Engineering and Technology
    • /
    • v.56 no.8
    • /
    • pp.2990-2998
    • /
    • 2024
  • In ITER, the evaluation of the activated water radiation source and its impact on the radiological levels is necessary to demonstrate compliance with the safety requirements. The use of simplified or conservative approaches often results in the application of expensive constraints on the installation that impact its economics, operations, and construction schedule. In this work, we propose a novel methodology to calculate the activated water source term with a higher degree of realism. The methodology is based on the coupling of a system-level code with a Computational Fluid Dynamics (CFD) code in an explicit, one-way approach. We apply this methodology to the evaluation of the16N radioisotope within the ITER Vacuum Vessel Primary Heat Transfer System (VV-PHTS) cooling circuit in a steady-state and transient scenarios. We chose this system since previous analyses of the VV-PHTS were done with simple, ad-hoc calculations that yielded results that differed by up to a factor of five, underscoring a higher level of uncertainty. As a result, we generate a computational model of the source term that can be used to evaluate the radiological condition surrounding the cooling systems during the operations.

Improvement of transmission-line-based fault locating for typical traveling-wave accelerator with constant-gradient structures

  • T.N. Hu;Y.F. Zeng;K. Peng;H. Hu;H.M. Wang;K.F. Liu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2011-2018
    • /
    • 2024
  • Since RF breakdown is one of the primary limitations to improving the performances of RF accelerators, extensive efforts have been dedicated to locating the breakdowns. However, most existing methods rely on specialized techniques, resulting in high financial burdens. Although the method based on transient response of transmission line (TL) is suitable for facilities with sporadic recoverable breakdowns, practical operations are susceptible to notable errors. This study revisits the fundamental theories of lossless TL and investigates the wave process to understand the characteristics of the reversed pulse induced by the breakdowns. By utilizing steadystate response of the TL and employing phasor method, we derive analytical formulas to determine the exact location of breakdowns within the faulty cell for constant-gradient TW accelerator. Furthermore, the derived formulas demonstrate their independence from RF phase, thereby distinguishing them from traditional phasebased methods. Additionally, experimental validations are conducted at the HUST injector, and the results confirm the consistency of the analysis. Thus, the proposed method represents a promising improvement over the TL-based approaches and serves as a valuable complement to current techniques. Importantly, this method demonstrates particular advantages for constructed TW accelerators seeking to achieve a balance among high performance, low costs, and compact layouts.

An Experimental Study on the Heat Transport Characteristics of a Sodium Heat Pipe for a Solar Furnace (태양열 반응로용 나트륨 히트파이프의 열이송 특성에 관한 실험적 연구)

  • Boo, Joon-Hong;Park, Cheol-Min;Kim, Jin-Soo;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.178-181
    • /
    • 2008
  • Cylindrical stainless-steel/sodium heat pipe for a high-temperature application was manufactured and tested for transient and steady-state operations. The container material was made of stainless-steel 316, and the working fluid was sodium. Stainless-steel 316 mesh screen was inserted as a capillary structure. The working fluid fill charge ratio was approximately 64 $\sim$ 181% based on the pore space of the wick. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 mm. The evaporator part was 150 mm and the condenser 80 mm. The performance test of the heat pipe has been conducted in the furnace with up to 800 W. The variation of the average heat transfer coefficient was investigated as a function of heat flux and vapor temperature. As input thermal load increased, it was showed that difference of temperatures in evaporator and condenser decreased and that operating section and heat transfer characteristics at the heat pipe increased.

  • PDF

Influence of the Effective Thermal Thansport Length on the Heat Transfer Characteristics of a Liquid-Metal Heat Pipe for High-temperature Solar Thermal Devices (유효열이송거리가 고온 태양열기기용 액체금속 히트파이프의 열전달 특성에 미치는 영향)

  • Park, Cheol-Min;Boo, Joon-Hong;Kim, Jin-Soo;Kang, Yong-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.220-225
    • /
    • 2008
  • Cylindrical stainless-steel/sodium heat pipe for a high-temperature solar thermal application was manufactured and tested for transient and steady-state operations. Two layers of stainless-steel screen mesh wick was inserted as a capillary structure. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 mm. The effective heat transport length, the thermal load, and the operating temperature were varied as thermal transport conditions of the heat pipe. The thermal load was supplied by an electric furnace up to 1kW and the cooling was performed by forced convection of air The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and vapor temperature. Typical range of the total effective thermal conductivity was as low as 43,500 W/m K for heat flux of 176.4 kW/$m^2$ and of operating temperature of 1000 K.

  • PDF

An Experimental Study on the Heat Transfer Characteristics of a High-temperature Sodium Heat Pipe Depending on the Thermal Transport Conditions (고온 나트륨 히트파이프에서 열이송 조건에 따른 열전달 특성에 대한 실험 연구)

  • Park, C.M.;Boo, J.H.;Kim, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2340-2345
    • /
    • 2008
  • Cylindrical stainless-steel/sodium heat pipe for a high-temperature application was manufactured and tested for transient and steady-state operations. Two layers of Stainless-steel screen mesh wick was inserted as a capillary structure. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 mm. As thermal transport conditions, the effective transport length, the heat flux, the tilt angle and the operating temperature were varied. The heat was supplied by an electric furnace up to 1 kW and the cooling was performed by forced convection of air. The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and vapor temperature. Typical range of the total thermal resistance was as low as $0.036^{\circ}C/W$ at $175.8\;kW/m^2$ of heat flux and $700^{\circ}C$ of operating temperature.

  • PDF