• 제목/요약/키워드: statistical reconstruction

검색결과 207건 처리시간 0.026초

A Study on the Population Structure of Democratic People's Republic of Korea

  • Jeon, Saebom;Kim, Seong Eun;Park, Yousung
    • Communications for Statistical Applications and Methods
    • /
    • 제22권1호
    • /
    • pp.1-10
    • /
    • 2015
  • The re-unification of the two Koreas is seen as a potential solution to the aging problem and low fertility, along with the increase in the old population structure of the Republic of Korea. Population structure is an indicator of national competitiveness or growth, but little is known officially about the populations of Democratic People's Republic of Korea (DPRK). Understanding the population structure of the DPRK is important to prepare for re-unification and estimate the socio-economic costs of national welfare under a re-unified Korea. In this paper, we assess reliability of the two modern national censuses of DPRK and use the limited resources available to reconstruct the intercensal populations between these two censuses. Excess deaths from the 1995 famine are estimated at 489,972 to 574,306 and are close to the estimates of Goodkind et al. (2011) and the reconstructed populations in the of DPRK implies a big difference between two Koreas.

Breast PET CT 영상 재구성 변화에 따른 대조도 대 잡음비와 신호 대 잡음비의 비교평가 (Evaluation and Comparison of Contrast to Noise Ratio and Signal to Noise Ratio According to Change of Reconstruction on Breast PET/CT)

  • 이재영;이을규;김기원;정회원;유광열;박훈희;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.79-85
    • /
    • 2017
  • 본 연구는 양전자 컴퓨터단층촬영(Positron Emission Computed Tomography; PET-CT) 유방암 영상에서 질환관심영역(Region of Interest; ROI)의 대조도 대 잡음비(Contrast to Noise Ratio; CNR)와 신호 대 잡음비(Signal to Noise Ratio; SNR)를 재구성 기법별로 측정 평가하여 통계적 분석을 하고자 하였다. 연구대상은 서울소재 대학병원에서 유방 양전자 컴퓨터단층촬영(Breast PET-CT)을 검사한 환자 100명이다. 측정방법은 ImageJ 프로그램을 사용하여 표본의 인구사회학적 특성, 영상 재구성 기법별 유방암의 SNR과 CNR의 평균값, 95% 신뢰구간 값, SNR과 CNR의 평균차이 값 등을 분석하였다. SPSS Statistics21 통계프로그램으로 ANOVA 분석을 하였으며 p<0.05에서 유의한 것으로 판단하였다. 영상 재구성 기법별 분석결과는 CNR과 SNR 모두 TrueX_TOF, Iterative, Iterative-TOF, FBP-TOF 순으로 높은 값을 나타냈다(p<0.05). CNR과 SNR수치로 영상 재구성 기법의 특징을 조합하여 PET/CT 검사의 정확성과 편의성을 제공할 것이라 사료된다.

산업공정반응기의 감마선 전산 단층촬영기술 개발 (Development of Tomographic Scan Method for Industrial Plants)

  • 김종범;정성희;문진호;권택용;조규성
    • 비파괴검사학회지
    • /
    • 제30권1호
    • /
    • pp.20-30
    • /
    • 2010
  • 본 논문에서는 평행빔, 팬빔, 콘빔 등 기존의 정형화된 전산화 영상촬영장치로 측정이 불가능한 산업 공정에 전산화 단층 촬영기술을 적용하기 위하여 개별 검출기 설치, 감마선 조사기 및 선원유도관을 통한 단면계측방법을 제안하였다. 단면 복원을 위해 검출기 볼륨을 고려한 가중치 함수를 제안하고 통계적 기반의 반복적 알고리즘을 적용하였다. 그리고 이와 같은 검출 구조에 따른 측정 결과물을 예측하고 본 방법의 타당성을 검증하기 위하여 두 종류의 팬텀에 대해 Monte Carlo 전산모사를 수행하였으며 이중 한개의 모델에 대하여 동일 계측조건을 갖는 Lab. 규모 측정 실험을 수행하였다. 전산 모사 결과 photopeak 에너지만 선별하여 계측한 경우가 전에너지에 대해 계측한 경우에 비해 높은 통계적 오차에도 불구하고 보다 참값에 근접한 결과를 보였다. 또한 동일 모형에 대한 전산 모사 및 측정 실험의 결과가 잘 일치함을 알 수 있었다. 이를 통하여 제안된 측정 기법의 유용성을 검증하였으며, 향후 석유화학시설의 설비 진단에 활용할 수 있을 것으로 기대된다.

정량적 도전율측정의 오차와 $B_1{^+}$ map의 노이즈에 관한 분석 (Quantitative Conductivity Estimation Error due to Statistical Noise in Complex $B_1{^+}$ Map)

  • 신재욱;이준성;김민오;최나래;서진근;김동현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권4호
    • /
    • pp.303-313
    • /
    • 2014
  • 목적: 자기공명 영상장치(MRI)의 송신 자기장 정보를 이용한 인체 내 도전율을 측정하는 기술이 최근 제안되었다. 송신 자기장 정보의 노이즈에 따른 도전율의 오차를 측정하고 도전율과 노이즈의 관계를 모델화 하였다. 대상과 방법: 송신 자기장의 분포는 원형 모델에 대해서 시뮬레이션을 수행하였다. 시뮬레이션으로 생성된 송신 자기장의 분포에 가우시안 노이즈를 더해준 후 정량적인 도전율 측정에 어떤 영향을 주는지 공명 주파수, 물체의 크기, 송신 자기장의 신호 대 잡음 비에 대해서 수행하였다. 각 각의 변수에 따른 도전율 대 잡음 비를 측정하여 모델화 하였다. 결과: 시뮬레이션 결과 도전율 측정은 송신 주파수의 크기 오차보다 위상 오차에 더 큰 영향을 받는 것을 보였다. 또한, 송신 자기장의 신호 대 잡음 비, 공명 주파수, 도전율 값, 평균필터의 크기에 따라서 도전율 대 잡음비가 비례하는 경향성을 보였다. 하지만, 물체를 둘러싼 외부 물질의 크기는 도전율 측정에 큰 영향을 주지 않았다. 위의 시뮬레이션 결과는 3T 임상용 MRI에서 원형 모델 팬텀에 대해서 검증되었다. 결론: 시뮬레이션을 통해 얻어진 변수와 도전율 측정의 오차와의 관계를 통해서 정량적인 도전율 측정에서 발생되는 오차를 모델화 할 수 있었다. 또한 제시된 분석 방법을 통하여 자기공명 영상 장치를 이용한 도전율 측정의 필터링 및 재구성 알고리즘의 효과를 검증 할 수 있을 것으로 보인다.

수술 후 장기적인 생리적 기능과 영양적 측면에서 본 원위부위절제술 후 재건술식의 비교; Billroth I 위십이지장문합술과 Roux-en Y 위공장문합술의 비교 (Comparison of Reconstruction Methods after Distal Gsstrectomy for Gastric Carcinoma in Terms of the Long Term Physiologic Function and Nutritional Status; Billroth I Gastroduodenostomy versus Roux-en Y Gastrojejunostomy)

  • 정오;오성태;육정환;최지은;김갑중;임정택;박건춘;김병식
    • Journal of Gastric Cancer
    • /
    • 제7권2호
    • /
    • pp.88-96
    • /
    • 2007
  • 목적: 원위부위절제술 후에 행하여지는 재건술은 Bill-roth I 문합술, Billroth II 문합술, Roux-en Y 위공장문합술이 있으며 이러한 술식들은 객관적 비교 평가가 어렵고 이에 대한 연구 또한 많지 않다. 이에 저자들은 원위부위절제술 후에 시행된 Billroth I 문합 술과 Roux-en Y 위공장문합술을 장기적인 생리적 기능과 영양적 측면에서 비교하였다. 대상 및 방법: 1999년부터 2002년까지 위암으로 수술을 시행 받은 환자 중 조기위암으로 원위부위절제술을 시행 받은 환자 663명을 대상으로 술 후 생리적 기능을 평가하는 설문지를 6개월 간격으로 작성하였다. 술 후 영양상태를 평가하기 위하여 혈중 총단백질, 알부민, 혈색소 농도를 측정하였으며 체중의 변화를 측정하였다. 결과: 생리적 기능 총합점수는 B-I 군에 비하여 RY 군에서 약간 낮았으나 통계학적인 차이를 보이지 않았다. 각 증상 별로 비교 시 역류 증상과 식 후 음식물 통과만이 차이를 보였으며 24개월 후에는 RY 군에서 음식물 통과가 양호한 것 외에는 차이를 보이지 않았다. 혈중 총단백질, 알부민, 혈색소는 모두 B-I 군에서 통계적으로 유의하게 높았으나 두군 모두 평균적으로 정상이상의 수치를 보였다. 몸무게 감소는 B-I 군에서 적은 것으로 나타났다. 결론: 장기적 생리기능의 측면에서는 RY 군이 일부 증상에서 우수하였고 영양적인 측면에서는 B-I 군이 우수하였다. 따라서 원위부위절제술 후 재건술의 선택은 이러한 장단점을 고려하여 시술자의 경험과 환자의 상태에 맞춰 선택해야 한다.

  • PDF

풍선 달린 카테터를 이용한 안저 파열 골절 정복의 선택적 사용 (Alternative Use of Inferior Blow-out Fracture Reduction with Urinary Balloon Catheter)

  • 박성훈;양호직
    • Archives of Plastic Surgery
    • /
    • 제34권6호
    • /
    • pp.729-734
    • /
    • 2007
  • Purpose: The operative treatment for blow-out fracture involves restoration of intra-orbital soft tissue and bony structural integrity. There are several methods for reconstruction of inferior blow out fracture. We report reduction of inferior blow-out fracture with urinary balloon catheter in comparison with $Medpor^{(R)}$ using group to complication rate. Methods: A retrospective study was performed on 67 patients who underwent inferior orbital blow-out fracture reconstruction with $Medpor^{(R)}$ implant or urinary balloon catheter following between 2003 and 2006. Hospital records were reviewed especially for preoperative and postoperative enophthalmos, diplopia, extraocular muscle movement limitations, and hypoesthesia between $Medpor^{(R)}$ implant group and balloon catheter using group. Results: There was no significant statistical difference between both groups on incidence of postoperative complications of enophthalmos, diplopia, extraocular muscle movement limitations, and hypoesthesia. Postoperative infection, ectropion were absent in both groups.Conclusion: The use of urinary balloon catheter is simple, fast and inexpensive. Urinary balloon catheter is an alternative and reliable use for reduction of inferior orbital blow-out fracture.

횡복직근피판술을 이용한 유방재건술 시 상복부의 누빔 봉합이 장액종을 예방하는가? (Does Abdominal Quilting Suture Prevent Seroma in TRAM Flap Breast Reconstruction?)

  • 이민영;이택종
    • Archives of Plastic Surgery
    • /
    • 제38권3호
    • /
    • pp.241-244
    • /
    • 2011
  • Purpose: Seroma formation is still major complication of abdominal donor site after TRAM flap surgery in spite of various efforts to reduce seroma formation such as closed suction drain. We performed a clinical study, that quilting suture at abdominal donor site can prevent seroma formation. Methods: Between May 2002 and September 2008, we performed 600 breast reconstructions using a unilateral TRAM flap except patients who has smoking history or abdominal scar. We performed 300 breast reconstructions without quilting sutures (A: Experimental group) until January 06, and after then 300 reconstructions with quilting sutures (B: Control group). We compared total drain output (mL), time to drain removal (days), and donor site complications between two groups. Results: There were no statistical difference at BMI (p=0.28) and time to remove suction drain between two group. (A: 8.37, B: 9.69) (p=0.40) But, total drain output was reduced with quilting suture. (A: 432.5, B: 495.2) (p=0.005) And also complication rate was decreased, such as seroma formation, epigastric bulging. (A: 1%, B: 7%) (p=0.005) Conclusion: Quilting suture is a simple and reliable method to reduce seroma formation and abdominal donor site complication.

점증적 증가를 이용한 첨점 기반의 간질 검출 (Detection of Epileptic Seizure Based on Peak Using Sequential Increment Method)

  • 이상홍
    • 디지털융복합연구
    • /
    • 제13권10호
    • /
    • pp.287-293
    • /
    • 2015
  • 본 논문에서는 신호 처리 기술과 가중 퍼지소속함수 기반 신경망 (Neural Network with Weighted Fuzzy Membership Functions; NEWFM)을 이용하여 간질을 검출하는 방안을 제안하였다. 신호 처리 기술로는 웨이블릿 변환(Wavelet Transform), 점증적 증가 방법, 위상공간 재구성(Phase Space Reconstruction)을 이용하였다. 신호 처리 기술의 첫 번째 단계에서는 웨이블릿 변환을 이용하여 뇌파로부터 웨이블릿 계수를 추출하였다. 두 번째 단계에서는 점증적 증가 방법을 이용하여 웨이블릿 계수로부터 첨점(Peak)을 추출하였다. 세 번째 단계에서는 위상공간 재구성을 이용하여 추출된 첨점으로부터 3차원 다이어그램을 생성하였다. NEWFM의 입력으로 사용할 16개의 특징을 추출하기 위하여 유클리드 거리와 통계적 방법을 이용하였다. 이들 16개의 특징을 NEWFM의 입력으로 사용하여 97.5%, 100%, 95%의 정확도, 특이도, 민감도를 각각 구하였다.

전 십자 인대 재건술에서 대퇴골측 고정 방법의 초기 안정성의 비교 (Comparison of Primary Stability of Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction)

  • 송은규;이근배;이문
    • 대한관절경학회지
    • /
    • 제2권1호
    • /
    • pp.85-92
    • /
    • 1998
  • Various methods for fixation of graft have been widely used for reconstruction of anterior cruciate ligament. However, the biomechanical strength of each fixation techniques are not fully understood. The purpose of this study is to compare the pull out strength of different fixation techniques which is probably the most important factor for the success at the initial stage of healing. Biomechanical test was carried out to measure and compare the pull out tensile strength of five different fixation techniques in 35 pig(Yorkshire) knees. ANOVA and Duncan multiple comparison test was applied for statistical analysis. In the two fixation techniques with bone patellar tendon bone graft, the mean maximum tensile strength was $1333.4{\pm}148.5N$ with titanium interference screw, while it was $1310.1{\pm}168.9N$ with biodegradable interference screw. The failure mode were pulled out of bone plugs from the femoral tunnel in majority cases. In the fixations with hamstring tendon, the mean maximum tensile strength were $1405.9{\pm}135.1N$ with SemiFix screw, $820.3{\pm}104.5N$ with biodegradable interference screw, and $682.1{\pm}54.2N$ with Endobutton. The mode of failure was variable in each technique. The tendon was pulled out from the tunnel in biodegradable interference screw fixation, the screw was bent in the SemiFix system, and the polyester tape were ruptured or the buttons were pulled into tunnel in Endobutton fixation. The mean maximum tensile strength of two interference screws with bone patellar tendon bone was statistically comparable to that of SemiFix with hamstring tendon. However biodegradable interference screw and Endobutton with hamstring tendon showed weaker maximum tensile strength than above three fixation techniques (P<0.05).

  • PDF

Evaluating the Effectiveness of Cryopreserved Acellular Dermal Matrix in Immediate Expander-Based Breast Reconstruction: A Comparison Study

  • Kim, So-Young;Lim, So Young;Mun, Goo-Hyun;Bang, Sa-Ik;Oh, Kap Sung;Pyon, Jai-Kyong
    • Archives of Plastic Surgery
    • /
    • 제42권3호
    • /
    • pp.316-320
    • /
    • 2015
  • Background CGCryoDerm was first introduced in 2010 and offers a different matrix preservation processes for freezing without drying preparation. From a theoretical perspective, CGCryoDerm has a more preserved dermal structure and more abundant growth factors for angiogenesis and recellularization. In the current study, the authors performed a retrospective study to evaluate freezing- and freeze-drying-processed acellular dermal matrix (ADM) to determine whether any differences were present in an early complication profile. Methods Patients who underwent ADM-assisted tissue expander placement for two stage breast reconstruction between January of 2013 and March of 2014 were retrospectively reviewed and divided into two groups based on the types of ADM-assisted expander reconstruction (CGDerm vs. CGCryoDerm). Complications were divided into four main categories and recorded as follows: seroma, hematoma, infection, and mastectomy skin flap necrosis. Results In a total of 82 consecutive patients, the CGCryoDerm group had lower rates of seroma when compared to the CGDerm group without statistical significance (3.0% vs. 10.2%, P=0.221), respectively. Other complications were similar in both groups. Reconstructions with CGCryoDerm were found to have a significantly longer period of drainage when compared to reconstructions with CGDerm (11.91 days vs. 10.41 days, P=0.043). Conclusions Preliminary findings indicate no significant differences in early complications between implant/expander-based reconstructions using CGCryoderm and those using CGDerm.