이중 차 전압을 이용한 전압 새그 검출 기법에 관한 연구 (The Study on Detecting Scheme of Voltage Sag using the Two Difference Voltage)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.65-73
    • /
    • 2014
  • In this paper, the detection scheme of the voltage variation using a two difference voltage is proposed. The conventional sag detector is from a single-phase digital phase-locked loop (DPLL) that is based on a d-q transformation using an all-pass filter (APF). The APF generates a virtual q-axis voltage component with $90^{\circ}$ phase delay but the APF cannot generate the virtual q-axis voltage depending on the phase of the grid voltage. To overcome the problem, q-axis voltage component is generated from difference between the current and previous value of d-axis voltage component in the stationary reference frame. However, the difference voltage around the zero crossing is not enough to detect the voltage sag. Therefore, the new detection scheme using the two difference voltage which can detect the sag around the zero crossing voltage is proposed.

Modulated Finite Control Set - Model Predictive Control for Harmonic Reduction in a Grid-connected Inverter

  • Nguyen, Tien Hai;Kim, Kyeong-Hwa
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.268-269
    • /
    • 2017
  • This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. Distorted grid condition is undesirable due to negative effects such as power losses and heating problem in electrical equipments. To enhance the power quality of distributed generation systems under such a condition, a modulated finite control set - model predictive control (MFCS-MPC) scheme will be proposed, in which the optimal switching signals of inverter are chosen by online basis using the principle of current error minimization. In addition, the moving average filter (MAF) is used to improve the phase-lock loop in order to obtain the harmonic-free reference currents on the stationary frame. The usefulness of the proposed MFCS-MPC method is proved by the comparative simulation results under different operating conditions.

  • PDF

이산 적응 관측자를 이용한 유도전동기의 회전자 속도 추정 (Induction motor rotor speed estimation using discrete adaptive observer)

  • 이상철;최창호;남광희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1060-1062
    • /
    • 1996
  • This paper presents a discrete adaptive observer for MIMO system of an IM model in DQ reference model. The IM model in the stationary frame is discretized and it is transformed into the canonical observer form. The unknown parameter is choosen as rotor speed. The adaptive law for parameter adjustment is obtained as a set of recursive equations which are derived by utilizing an exponentially weighted normalized least-square method. The proposed adaptive observer converges rapidly and is also shown to track time-varying plant parameter quickly. Its effectiveness has been demonstrated by computer simulation.

  • PDF

다양한 불평형 전압이 인가된 3상 유도전동기의 동적특성 분석 (Analysis of Dynamic Characteristics of Three Phase Induction Motor Applied by Various Unbalanced Voltage)

  • 김태한;좌종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.810-812
    • /
    • 2003
  • The dynamic characteristics of a three phase induction motor which is applied by various unbalanced voltages are simulated and analyzed in this paper. The voltage equations and torque equation in the dq stationary reference frame for the three phase star connected induction motor are used in this analysis. MATLAB and SIMULINK are employed as a simulation tool. The dynamic characteristics of speed and torque are simulated for various unbalanced voltages, that is, (1) cases with the same unbalance voltage factor but different unbalanced voltages, (2) cases with only one unbalanced voltages but different degree of unbalance, and (3) cases with the same positive sequence voltage but different negative sequence voltages. The simulated results are compared and analyzed with each other, and also with the results of balanced voltage.

  • PDF

센서리스 유도전동기를 위한 개선된 적응 슬라이딩 모드 관측기의 설계 (Design of Adaptive Sliding Observer for Sensorless Induction Motor Drive)

  • 김상민;한우용;김성중;이창구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1138-1141
    • /
    • 2003
  • This paper proposes a new speed and flux estimation method which has the robustness against the variation of the electrical parameters of the motor and the superiority in the dynamic characteristics compared with the conventional sensorless schemes. In the proposed method, the stator currents and the rotor fluxes are observed on the stationary reference frame using the sliding mode concept. And the rotor speed is estimated using the current estimation errors and the observed rotor fluxes based on the Lyapunov stability theory. Also a design method of the observer gain is proposed to minimize the effect of the speed estimation error on the rotor flux observation. The experimental results verified that the proposed method shows more robust and improved performances than the previous estimation method under the variations of motor resistance and inductance.

  • PDF

DQ 등가회로를 이용한 DFIG 보호계전방식 (Protection relaying algorithm for DFIG using a DQ equivalent circuit)

  • 강용철;이지훈;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.23-24
    • /
    • 2007
  • Most of modern wind turbines employs a doubly-fed induction generator (DFIG) system because it has many advantages due to variable-speed operation, relatively high efficiency and it small converter size. The DFIG system uses a wound rotor induction machine so that the magnetizing current of the generator can be fed from both the stator and the rotor. This paper presents a protection relaying algorism for DFIG using the DQ equivalent circuits. The induced voltages calculated from the stator and rotor sides are nearly the same in the steady state. They become different in the DQ equivalent circuits during an internal fault. The proposed algorithm compares the inducted voltages estimated from the stator and the rotor circuit converted into the stationary reference frame. If the difference between the induced voltages exceeds the threshold, the proposed algorithm detects an turn-to-turn fault.

  • PDF

단상 인버터 시스템에서 영 전압 근처 전압 강하 검출 기법에 관한 연구 (The Study on Sag Detecting Scheme around Zero Crossing Voltage for Single-Phase Inverter System)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.96-104
    • /
    • 2014
  • The all pass filter generates a virtual q-axis voltage component with $90^{\circ}$ phase delay but the virtual q-axis voltage cannot detect the voltage depending on the phase of the grid voltage. To overcome the problem, q-axis voltage component is generated from difference between the current and previous value of d-axis voltage component in the stationary reference frame. However, the difference voltage between the current and previous value around the zero crossing voltage is not enough to detect the voltage sag. Therefore, the new detection scheme which can detect the sag around the zero crossing voltage is proposed.

매입형 영구자석 동기 전동기의 고주파 신호 주입 센서리스 제어를 위한 정지 좌표계 상에서의 새로운 회전자 위치 추정 기법 (Novel Rotor Position Estimation Method in Stationary Reference Frame for High Frequency Signal Injection Sensorless Control in IPMSM)

  • 송의영;임준혁;김상일;김래영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.337-338
    • /
    • 2015
  • 본 논문에서는 고주파 신호 주입 센서리스 제어를 위한 정지 좌표계 상의 회전자 위치를 추정하는 새로운 기법에 대하여 제안한다. 기존 방법은 저역 통과 필터의 시지연 및 전류 차로 이루어진 행렬의 역행렬 유무 문제가 존재하였다. 제안된 기법은 이러한 문제의 해결방안으로 정지 좌표계 상에서 변환 행렬을 이용하여 회전자 위치 정보를 추출해 낸다. 또한 추출해 낸 위치 정보로 전대역 통과 필터를 이용하여 회전자 위치를 정밀하게 추정하게 된다. 시뮬레이션을 통하여 제안된 방법의 타당성을 검증하였다.

  • PDF

Control of Circulating Current in Modular Multilevel Converter under Unbalanced Voltage using Proportional-Resonant Controller

  • Quach, Ngoc-Thinh;Chae, Sang Heon;Kim, Eel-Hwan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.143-144
    • /
    • 2016
  • The circulating current control within the phase legs is one of the main control objectives in a modular multilevel converter (MMC) under different operating conditions. This paper proposes a control strategy of circulating currents in the MMC under unbalanced voltage by using a proportional-resonant (PR) controller. Under the unbalanced voltage, the circulating currents in the MMC consists of three components such as positive-sequence, negative-sequence, and zero-sequence circulating currents. With the PR controller, all components of the circulating current will be directly controlled in the stationary reference frame without decomposing into positive- and negative-sequence components. Thus, the ripples in the circulating currents and the DC current are suppressed under the unbalanced voltage. The effectiveness of the proposed method is verified by simulation results based on PSCAD/EMTDC simulation program.

  • PDF

표면 부착형 동기 전동기 벡터 제어에서의 외란 관측기 기반 전류 측정 오프셋 오차 보상 방법 (Disturbance Observer-based Current Measurement Offset Error Compensation in Vector-controlled SPMSM Drives)

  • 이상민;이기복
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.402-409
    • /
    • 2022
  • In vector-controlled drive systems, the current measurement offset error causes unwanted torque ripple, resulting in speed and torque control performance degradation. The current measurement offset error is caused by various factors, including thermal drift. This study proposes a simple DC offset error compensation method for a surface permanent magnet motor based on a disturbance observer. The disturbance observer is designed in the stationary reference frame. The proposed method uses only the measured current and machine parameters without additional hardware. The effect of parameter variations is analyzed, and the performance of the current measurement offset error compensation method is validated using simulation and experimental results.