• 제목/요약/키워드: static testing

검색결과 504건 처리시간 0.028초

Full-scale tests and finite element analysis of arched corrugated steel roof under static loads

  • Wang, X.P.;Jiang, C.R.;Li, G.Q.;Wang, S.Y.
    • Steel and Composite Structures
    • /
    • 제7권4호
    • /
    • pp.339-354
    • /
    • 2007
  • Arched Corrugated Steel Roof (ACSR) is a kind of thin-walled steel shell, composing of arched panels with transverse small corrugations. Four full-scale W666 ACSR samples with 18m and 30m span were tested under full and half span static vertical uniform loads. Displacement, bearing capacities and failure modes of the four samples were measured. The web and bottom flange in ACSR with transverse small corrugations are simplified to anisotropic curved plates, and the equivalent tensile modulus, shear modulus and Poisson's ratio of 18m span ACSR were measured. Two 18 m-span W666 ACSR samples were analyzed with the Finite Element Analysis program ABAQUS. Base on the tests, the limit bearing capacity of ACSR is low, and for half span loading, it is 74-75% compared with the full span loading. When the testing load approached to the limit value, the bottom flange at the sample's bulge place locally buckled first, and then the whole arched roof collapsed suddenly. If the vertical loads apply along the full span, the deformation shape is symmetric, but the overall failure mode is asymmetric. For half span vertical loading, the deformation shape and the overall failure mode of the structure are asymmetric. The ACSR displacement under the vertical loads is large and the structural stiffness is low. There is a little difference between the FEM analysis results and testing data, showing the simplify method of small corrugations in ACSR and the building techniques of FEM models are rational and useful.

실리콘겔 인공유방의 기계적 및 물리화학적 특성에 대한 연구 (Study for Mechanical and Physicochemcial Properties of Silicone Gel Filled Mammary Implants)

  • 백홍;장동혁;송정민;이승영;서무엽;박길종;맹은호
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권2호
    • /
    • pp.89-97
    • /
    • 2012
  • The purpose of this study is to develop the guideline of the physicochemical and mechanical properties evaluation for silicone gel filled breast implants. First of all, the use and development status for silicone gel filled breast implants were investigated, and then, standard and criteria about performance evaluation established by the international organizations such as ASTM, FDA guidance and ISO were examined. To evaluate the mechanical properties, data research and testing for breaking strength, elongation, tensile set, joint intensity, silicone gel cohesion, weight loss from heating, static rupture resistance, impact resistance test, fatigue test, and gel bleed were performed. On the other hand, to evaluate the physicochemical properties, volatile matter, extent of cross linking, heavy metals, and extractable were analyzed. In this study, results for general function, mechanical properties and physicochemical properties were examined and reviewed for the accordance with international standard, and objective and standardized guideline was provided.

자동화된 프로그램 시험을 위한 입력 자료구조의 모양 식별 (Identifying a Shape of Input Data Structure for Automated Program Testing)

  • Insang, Chung
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제31권10호
    • /
    • pp.1304-1319
    • /
    • 2004
  • 프로그램 시험 비용은 테스트 데이타를 생성하는 과정을 자동화함으로써 상당히 줄일 수 있다. 테스트 데이타 생성은 보통 선택된 프로그램 경로를 실행하는 입력 값들을 식별하는 데 주안점을 둔다. 지금까지 많은 연구가 있어왔지만 여전히 해결해야할 문제가 있다 그러한 문제들 중에 모양 문제가 있다. 모양 문제는 주어진 프로그램 경로를 수행하기 위해 요구되는 입력 자료구조를 밝혀내는 문제이다. 이 논문에서 이 모양 문제에 대한 새로운 방법을 제시한다. 이 방법은 주어진 경로를 포인터 역 참조가 없는 정적단일 할당문 (Static Single Assignment, SSA) 형태로 변환한다. 이는 주어진 경로 상에 존재하는 각 프로그램 문장을 등식이나 부등식과 같은 제약식으로 간주할 수 있게 해준다. 이러한 제약식에 대한 해는 각 입력 변수에 대한 'points-to relation' 형태로 나타난다. 간단한 예들을 통하여 제안한 방법에 대해 설명한다.에 대해 설명한다.

The Development of Rhythmic Balance Training Equipment and its Effect on Performance for Elderly

  • Park, Da Won;Won, Cho Rong;Lee, Sung Ro;Park, Yang Sun
    • 한국운동역학회지
    • /
    • 제26권3호
    • /
    • pp.323-331
    • /
    • 2016
  • Objective: The aims of this study were 1) to develop easy-to-use rhythmic balance training equipment for the elderly and 2) to investigate the effect of training with the equipment on balance and physical function. Method: Twenty-one elderly individuals (age: $75.4{\pm}3.34yrs$, height: $152.07{\pm}4.81cm$, weight: $58.35{\pm}8.34kg$) participated in this study. Each participant underwent balance and physical function testing before and after 12 weeks of training with the equipment. Y-balance (i.e. dynamic balance) and one leg static balance tests were used for balance testing, and timed up- and-down-stairs and five times sit-to-stand tests were used for physical function testing. A paired t test was used to determine whether there was a significant pre- and post-training difference. Results: The rhythmic balance training equipment provided a fun and motivating training program with age-friendly music, dance movements for lower extremity strength training, and touch screen controls with simple features. Post-training left foot dynamic balance was significantly greater (p<.05), and static balance with eyes open was significantly improved (p<.05) compared to pre-training. Completion of the timed up-and-down-stairs and the five times sit-to-stand tests was significantly shorter (p<.05) compared to pre-training. Conclusion: Training using the equipment developed in this study improved balance and physical function in elderly participants.

Destructive testing of adhesively bonded joints under static tensile loading

  • Ochsner, A.;Gegner, J.
    • 접착 및 계면
    • /
    • 제5권2호
    • /
    • pp.22-36
    • /
    • 2004
  • Several in-situ testing methods of adhesively bonded joints under static short-time tensile loading are critically analyzed in terms of experimental procedure and data evaluation. Due to its rather homogeneous stress state across the glue line, the tensile-shear test with thick single-lap specimens, according to ISO 11003-2, has become the most important test process for the determination of realistic materials parameters. This basic method, which was improved in both, the experimental part by stepped adherends and easily attachable extensometers and the evaluation procedure by numeric substrate deformation correction and test simulation based on the finite element method (FEM), is therefore demonstrated by application to several kinds of adhesives and metallic adherends. Multi-axial load decreases the strength of a joint. This effect, which is illustrated by an experimental comparison, impedes the derivation of realistic mechanical characteristics from measured force-displacement curves. It is shown by numeric modeling that tensile-shear tests with thin plate substrates according to ISO 4587, which are widely used for quick industrial quality assurance, reveal an inhomogeneous stress state, especially because of relatively large adherend deformation. Complete experimental determination of the elastic properties of bonded joints requires independent measurement of at least two characteristics. As the thick-adherend tensile-shear test directly yields the shear modulus, the tensile butt-joint test according to ISO 6922 represents the most obvious complement of the test programme. Thus, validity of analytical correction formulae proposed in literature for the derivation of realistic materials characteristics is verified by numeric simulation. Moreover, the influence of the substrate deformation is examined and a FEM correction method introduced.

  • PDF

동적하중을 받는 기능성 고폭화약조성 시뮬런트 재료물성 연구 (A Study on Dynamic Material Properties of Functional High Explosive Formulation Simulant Subjected to Dynamic Loading)

  • 박정수;염기선;박충희;정세환;이근득;허훈
    • 한국군사과학기술학회지
    • /
    • 제16권6호
    • /
    • pp.857-866
    • /
    • 2013
  • This paper is concerned with the material properties of functional high explosive(FHX) simulant at various strain rates ranging from $10^{-4}/sec$ to $10^1/sec$. Material properties of FHX at high strain rates are important in prediction of deformation modes of FHX in a warhead which undergoes dynamic loading. Inert FHX stimulant which has analogous mechanical properties with FHX was utilized for material tests due to safety issues. Uniaxial tensile tests at quasi-static strain rates ranging from $10^{-4}/sec$ to $10^{-2}/sec$ and intermediate strain rates ranging from $10^{-1}/sec$ to $10^1/sec$ were conducted with JANNAF specimen using a tensile testing machine, INTRON 5583, and developed high speed material testing machine, respectively. Uniaxial compressive tests at quasi-static strain rates and intermediate strain rates were conducted with cylindrical specimen using a dynamic materials testing machine, INSTRON 8801. And cyclic compressive loading tests were performed with various strain rates and strains. Deformation behaviors were investigated using captured images obtained from a high-speed camera.

Taming of large diameter triaxial setup

  • Nair, Asha M.;Madhavi Latha, G.
    • Geomechanics and Engineering
    • /
    • 제4권4호
    • /
    • pp.251-262
    • /
    • 2012
  • Triaxial tests are essential to estimate the shear strength properties of the soil or rock. Normally triaxial tests are carried out on samples of 38 mm diameter and 76 mm height. Granular materials, predominantly used in base/sub-base construction of pavements or in railways have size range of 60-75 mm. Determination of shear strength parameters of those materials can be made possible only through triaxial tests on large diameter samples. This paper describes a large diameter cyclic triaxial testing facility set up in the Geotechnical Engineering lab of Indian Institute of Science. This setup consists of 100 kN capacity dynamic loading frame, which facilitates testing of samples of up to 300 mm diameter and 600 mm height. The loading ram can be actuated up to a maximum frequency of 10 Hz, with maximum amplitude of 100 mm. The setup is capable of carrying out static as well as dynamic triaxial tests under isotropic, anisotropic conditions with a maximum confining pressure of 1 MPa. Working with this setup is a difficult task because of the size of the sample. In this paper, a detailed discussion on the various problems encountered during the initial testing using the equipment, the ideas and solutions adopted to solve them are presented. Pilot experiments on granular sub-base material of 53 mm down size are also presented.

t-ws 고장 검출을 위한 테스트 방법의 개선 (Improvement of Test Method for t-ws Falult Detect)

  • 김철운;김영민;김태성
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권4호
    • /
    • pp.349-354
    • /
    • 1997
  • This paper aims at studying the improvement of test method for t-weight sensitive fault (t-wsf) detect. The development of RAM fabrication technology results in not only the increase at device density on chips but also the decrease in line widths in VLSI. But, the chip size that was large and complex is shortened and simplified while the cost of chips remains at the present level, in many cases, even lowering. First of all, The testing patterns for RAM fault detect, which is apt to be complicated , need to be simplified. This new testing method made use of Local Lower Bound (L.L.B) which has the memory with the beginning pattern of 0(l) and the finishing pattern of 0(1). The proposed testing patterns can detect all of RAM faults which contain stuck-at faults, coupling faults. The number of operation is 6N at 1-weight sensitive fault, 9,5N at 2-weight sensitive fault, 7N at 3-weight sensitive fault, and 3N at 4-weight sensitive fault. This test techniques can reduce the number of test pattern in memory cells, saving much more time in test, This testing patterns can detect all static weight sensitive faults and pattern sensitive faults in RAM.

  • PDF

The Test-Retest Reliability of Subjective Visual Horizontal Testing: Comparisons between Solid and Dotted Line Images

  • Zakaria, Mohd Normani;Wahat, Nor Haniza Abdul;Zainun, Zuraida;Sakeri, Nurul Syarida Mohd;Salim, Rosdan
    • Journal of Audiology & Otology
    • /
    • 제24권2호
    • /
    • pp.107-111
    • /
    • 2020
  • The present study aimed to determine the test-retest reliability of subjective visual horizontal (SVH) testing when tested with solid and dotted line images. In this repeated measures study, 36 healthy young Malaysian adults (mean age=23.3±2.3 years, 17 males and 19 females) were enrolled. All of them were healthy and had no hearing, vestibular, balance, or vision problems. The SVH angles were recorded from each participant in an upright body position using a computerized device. They were asked to report their horizontality perception for solid and dotted line images (in the presence of a static black background). After 1 week, the SVH procedure was repeated. The test-retest reliability of SVH was found to be good for both solid line [intraclass correlation (ICC)=0.80] and dotted line (ICC=0.78). As revealed by Bland-Altman plots, for each visual image, the agreements of SVH between the two sessions were within the clinically accepted criteria (±2°). The SVH testing was found to be temporally reliable, which can be clinically beneficial. Both solid and dotted lines in the SVH testing are reliable to be used among young adults.

The Test-Retest Reliability of Subjective Visual Horizontal Testing: Comparisons between Solid and Dotted Line Images

  • Zakaria, Mohd Normani;Wahat, Nor Haniza Abdul;Zainun, Zuraida;Sakeri, Nurul Syarida Mohd;Salim, Rosdan
    • 대한청각학회지
    • /
    • 제24권2호
    • /
    • pp.107-111
    • /
    • 2020
  • The present study aimed to determine the test-retest reliability of subjective visual horizontal (SVH) testing when tested with solid and dotted line images. In this repeated measures study, 36 healthy young Malaysian adults (mean age=23.3±2.3 years, 17 males and 19 females) were enrolled. All of them were healthy and had no hearing, vestibular, balance, or vision problems. The SVH angles were recorded from each participant in an upright body position using a computerized device. They were asked to report their horizontality perception for solid and dotted line images (in the presence of a static black background). After 1 week, the SVH procedure was repeated. The test-retest reliability of SVH was found to be good for both solid line [intraclass correlation (ICC)=0.80] and dotted line (ICC=0.78). As revealed by Bland-Altman plots, for each visual image, the agreements of SVH between the two sessions were within the clinically accepted criteria (±2°). The SVH testing was found to be temporally reliable, which can be clinically beneficial. Both solid and dotted lines in the SVH testing are reliable to be used among young adults.