• Title/Summary/Keyword: static studies

Search Result 927, Processing Time 0.028 seconds

Static Characteristic and Dynamic Characteristic Experiment of First-stage Proportional Pressure Control Valve (1단 비례 압력제어밸브의 정특성 및 동특성 실험)

  • Jeong, Heon-Sul;Nam, Ji-Woo;Lim, Hyo-Joon;Jung, Seung-Wook;Han, Sung-Min
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.18-24
    • /
    • 2010
  • Because of the increasing demand on the high precision and high response of a machinery, electronic control valves are widely adopted at various application fields. This paper studies on the static characteristic of a first-stage proportional pressure control valve. At first an experimental apparatus including hyd. pump variable speed inverter, pressure and data aquisition system was setted up with the experimental apparatus, various tests such as P-Q-W test, hyd, pump, dynamic, static, frequency response test of the proportional valve was carride out and the results are discussed.

  • PDF

A Semantics-based protocol for Business Process Transactions (비즈니스 프로세스 트랜잭션을 위한 시맨틱스 기반의 프로토콜)

  • Kang, Dong-Woo;Lee, Sun-Jae;Lee, Jae-Yeol;Kim, Kwang-Soo
    • The Journal of Society for e-Business Studies
    • /
    • v.11 no.2
    • /
    • pp.93-110
    • /
    • 2006
  • A Business Process Management System(BPMS) requires transaction management to guarantee reliability for transactions. Though several transaction protocols have been suggested for the transaction management, the difference of transaction protocols interrupts interoperability among transaction management systems. In this paper, a business process transaction based on semantics is suggested. It is defined based on the static semantics and the operational semantics. As the static semantics defines the ontologies for transaction states and transaction messages using Web Ontology Language(OWL), it solves the difference of expression for the concepts of transaction protocols. As the operational semantics defines state transitions of business process transactions using Abstract State Machine(ASM), it can guarantee formalism for transaction operations. The operational semantics refers to the state ontology and message ontology defined in the static semantics. This approach can enhance interoperability among various transaction protocols, increase the understandability for the transaction protocols, and support autonomous transaction execution and systematic transaction monitoring.

  • PDF

Structural Behavior on the Externally Strengthened Bridge Deck with Glass Fiber Reinforced Polymer (유리섬유보강재로 외부부착 보강된 교량 바닥판의 구조거동)

  • 오홍섭;심종성;최장환
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.922-933
    • /
    • 2002
  • Since the deterioration of concrete bridge decks affect durability, safety, and function, structural rehabilitation of damaged concrete deck that was strengthened with Fiber Reinforced Polymer(FRP) is increasing the latest. But recent studies on the strengthened structures are focused on the static behavior, however only a few studies on the fatigue behavior are performed. In this study, static and fatigue behavior of strengthened deck were peformed on 11 deck specimens strengthened with sheet typed Glass Fiber Reinforced Polymer(GFRP) that were reinforced by two different strengthening methods for the static test. A amount of strengthening material in the each direction such as transverse and longitudinal was adopted experimental variables for the static test and also the stress level of the static maximum load are adopted for the fatigue test. By the results of the experimental study, with respect to the strengthened decks, the resistance effect of crack propagation and effect of stress distribution are improved. In addition, the rate of variation of compliance decreased.

Immediate Effects of Ankle Dorsiflexor Facilitation Dynamic Taping on Static and Dynamic Balance and Gait Speed in Stroke Patients With Foot Drop (발등굽힘근 촉진 다이나믹 테이핑이 발 처짐이 있는 뇌졸중 환자의 정적, 동적 균형과 보행 속도에 미치는 즉각적 효과)

  • Im, Jin-gu;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.19-27
    • /
    • 2022
  • Background: Foot drop is a common symptom in stroke patients. Tape applications are widely used to manage foot drop symptoms. Previous studies have evaluated the effects of static and dynamic balance and gait on foot drop using kinesiology tape; however, only few studies have used dynamic tape application in stroke patients with foot drop. Objects: The purpose of this study was to investigate the immediate effects of dynamic taping, which facilitates the dorsiflexor muscle, on static and dynamic balance and gait speed in stroke patients with foot drop. Methods: The study included 34 voluntary patients (17 men, 17 women) with stroke. The patients were randomly assigned to the experimental group (n = 17), wherein dynamic taping was used to facilitate the dorsiflexor muscle, or the control group (n = 17), wherein kinesiology taping was used. Before the taping application, velocity average, path-length average, Berg balance scale, and timed up and go test (TUG) were recorded to measure static and dynamic balance, whereas the 10-meter walk test (10MWT) was used to measure gait speed. After the taping application, these parameters were re-evaluated in both groups. Repeated measure analysis of variance was used. Statistical significance levels were set to α = 0.05. Results: Except for the 10MWT scores in the control group, significant differences were noted in all the parameters measured for static and dynamic balance and gait speed between the pre and post-test (p < 0.05). However, the parameters showed significant interaction effects between group and time in the TUG and 10MWT (p < 0.01). Conclusion: These results indicate that compared with kinesiology taping, dynamic taping used in chronic stroke patients with foot drop had a more significant effect on dynamic balance and gait speed.

Investigations on the influence of radial confinement in the impact response of concrete

  • Al-Salloum, Yousef;Alsayed, Saleh;Almusallam, Tarek;Ibrahim, S.M.;Abbas, H.
    • Computers and Concrete
    • /
    • v.14 no.6
    • /
    • pp.675-694
    • /
    • 2014
  • Annular and solid concrete specimens with different aspect ratios and static unconfined compressive strengths were studied for impact loading using SHPB test setup. Numerical simulations in LSDYNA were also carried out and results were validated. The stress-strain curves obtained under dynamic loading were also compared with static compressive tests. The mode of failure of concrete specimen was a typical ductile failure at high strain rates. In general, the dynamic increase factor (DIF) of thin solid specimens was higher than thick samples. In the numerical study, the variation of axial, hydrostatic and radial stresses for solid and annular samples was studied. The core phenomenon due to confinement was observed for solid samples wherein the applied loads were primarily borne by the innermost concrete zone rather than the outer peripheral zone. In the annular samples, especially with large diameter inside hole, the distribution of stresses was relatively uniform along the radial distance. Qualitatively, only a small change in the distribution of stresses for annular samples with different internal diameters studied was observed.

Low-ε Static Probe Development for 15N-1H Solid-state NMR Study of Membrane Proteins for an 800 MHz NB Magnet

  • Park, Tae-Joon;Choi, Sung-Sub;Jung, Ji-Ho;Park, Yu-Geun;Kim, Yongae
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.823-826
    • /
    • 2013
  • A low-${\varepsilon}$ solid-state NMR(Nuclear Magnetic Resonance) probe was developed for the spectroscopic analysis of two-dimensional $^{15}N-^1H$ heteronuclear dipolar coupling in dilute membrane proteins oriented in hydrated and dielectrically lossy lipid environments. The system employed a 800 MHz narrow-bore magnet. A solenoid coil strip shield was used to reduce deleterious RF sample heating by minimizing the conservative electric fields generated by the double-tuned resonator at high magnetic fields. The probe's design, construction, and performance in solid-state NMR experiments at high magnetic fields are described here. Such high-resolution solid-state NMR spectroscopic analysis of static oriented samples in hydrated phospholipid bilayers or bicelles could aid the structural analysis of dilute biological membrane proteins.

Analysis of $f_T$ and $f_{max}$ Dependence on Unit Gate Finger Width for RF Performance Optimization of MOSFETs (MOSFET의 RF 성능 최적화를 위한 단위 게이트 Finger 폭에 대한 $f_T$$f_{max}$의 종속데이터 분석)

  • Cha, Ji-Yong;Cha, Jun-Young;Jung, Dae-Hyoun;Lee, Seong-Hearn
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.9
    • /
    • pp.21-25
    • /
    • 2008
  • In this study, to maximize RF performance of MOSFETs, $f_T$ and $f_{max}$ dependent data on $W_u$ are measured and newly analyzed by extracting small-signal model parameters. From the physical analysis results, it is found that a peak value of $f_T$ is generated by $W_u$-independent parasitic gate-bulk capacitance at narrow $W_u$ and the wide width effect of reducing the increasing rate of transconductance at wide $W_u$. In addition, it is revealed that a maximum value of $f_{max}$ is caused by the non-quasi-static effect that the gate resistance is greatly reduced at narrow $W_u$ and becomes constant at wide $W_u$.

The Effect of Therapeutic Ultrasound and Static Stretching of the Hamstring Muscle on Flexibility and Static Balance Ability (초음파 치료와 정적 스트레칭이 뒤넙다리근의 유연성과 정적균형에 미치는 영향)

  • Cho, Seung-bong;Park, Mi-young;Won, Ji-sun;Kim, Ye-lin;Hong, Joon-taek;Kim, Seong-ho
    • Journal of Korean Physical Therapy Science
    • /
    • v.26 no.1
    • /
    • pp.45-53
    • /
    • 2019
  • Background: The purpose of present study was to examine the effect of ultrasound therapy and static stretching on hamstring length and balance. Design: Randomized Controlled Trial. Methods: A total of 30 adults in S college, Seongnam city, Gyeonggi-do, between the ages of 20-30 were randomly assigned to two groups. Group 1 (n=15) had ultrasound therapy, called US group. Group 2 (n=15) had static stretching, called SS group. Measurements were taken prior to starting the program and after completing the experiment using Finger to floor test and Active knee extension test to get the results of hamstring flexibility and the ability of static balance. Paired t-test was used to compare each group pre-test values to post-test values and to compare US post-test values to SS post-test values on PASW 18.0. Results: 1) Both hamstring SS group and US group had significant increase (p<.05) in Finger to floor test and Active knee extension test. 2) Dominant leg standing had significant change (p<.05) only in US group. 3) There was no significant difference between US group and SS group. Conclusion: Results showed that US group and SS group had an effect on changes in hamstring length (p<.05). However, they did not show a significant increase in static balance. Further effective studies on hamstring SS group and US group were needed based on this examination.

The Effects of Knee Muscular Fatigue on One-Leg Static Standing Balance (슬관절 근육 피로가 한 발 정적기립 균형능력에 미치는 영향)

  • Kwon, Oh-Yun;Choi, Houng-Sik;Yu, Byong-Kyu
    • Journal of Korean Physical Therapy Science
    • /
    • v.4 no.2
    • /
    • pp.391-397
    • /
    • 1997
  • The purposes of this study were to determine wether knee muscular fatigue affects on one-leg static standing balance. Sixty four healthy subjects were used for this study : 44 men and 20 women, with an average age of 19.52. One leg static standing balance was measured at pre-fatigue and post-fatigue by an instrumented balance assessment system(kinesthetic ability training balance platform) which is commercially available for testing or training balance. Isokinetic exercises were used to evoke muscle fatigue at 180 degree/see by Cybex 1200. One leg static standing balance ability was significantly decreased after knee muscular fatigue. Although these phenomenons were not clearly understood, these results have important implications for rehabilitation in fatigable patients. These results suggest that the excessive fatiguing during rehabilitation in patients with fatigable disease may increase risk of reinjury and falling injury due to balance disturbance. Further studies are required to determine the physiological mechanisms of muscle fatigue that can play in decreasing one-leg static standing balance ability.

  • PDF

A GQM Approach to Evaluation of the Quality of SmartThings Applications Using Static Analysis

  • Chang, Byeong-Mo;Son, Janine Cassandra;Choi, Kwanghoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.6
    • /
    • pp.2354-2376
    • /
    • 2020
  • SmartThings is one of the most popular open platforms for home automation IoT solutions that allows users to create their own applications called SmartApps for personal use or for public distribution. The nature of openness demands high standards on the quality of SmartApps, but there have been few studies that have evaluated this thoroughly yet. As part of software quality practice, code reviews are responsible for detecting violations of coding standards and ensuring that best practices are followed. The purpose of this research is to propose systematically designed quality metrics under the well-known Goal/Question/Metric methodology and to evaluate the quality of SmartApps through automatic code reviews using a static analysis. We first organize our static analysis rules by following the GQM methodology, and then we apply the rules to real-world SmartApps to analyze and evaluate them. A study of 105 officially published and 74 community-created real-world SmartApps found a high ratio of violations in both types of SmartApps, and of all violations, security violations were most common. Our static analysis tool can effectively inspect reliability, maintainability, and security violations. The results of the automatic code review indicate the common violations among SmartApps.