• Title/Summary/Keyword: static parameters

Search Result 1,194, Processing Time 0.028 seconds

Capacitive Equivalent Circuit Modeling for Coplanar Waveguide Discontinuities (코플래너 웨이브가이드 불연속에 대한 용량성 등가회로 모델링)

  • 박기동;임영석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.5
    • /
    • pp.486-487
    • /
    • 1997
  • This paper presents the pure capacitive lumped element equivalent circuits for several coplanar waveguide(CPW) discontinuities such as an open-end, an open-end with connected ground planes, a gap and an open-end CPW stub and gives their capacitive element values as a function of physical dimensions of the discontinuity and the frequency for a specific substrate. The capacitive element values are determined from the scattering parameters which are obtained using the finite-difference time-domain(FDTD) method. For an open-end, an open-end with connected ground planes and a gap, the numerical results of the FDTD are compared with the quasi-static results which are calculated using the three- dimensional finite difference method(3D-FDM).

  • PDF

Mixed $H_{2}/H_{\infty}$ Controller Design for Descriptor Systems (디스크립터 시스템을 위한 혼합 $H_{2}/H_{\infty}$제어기의 설계)

  • Choe, Yeon-Wook
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.7
    • /
    • pp.483-490
    • /
    • 2004
  • The descriptor system model has a high ability in representing dynamical systems. It can preserve physical parameters in the coefficient matrices, and describe the dynamic part, static part, and even the improper part of the system in the same form. The design of mixed $H_{2}/H_{\infty}$ controllers for linear time-invariant descriptor systems is considered in this paper. Firstly, an $H_2$ and $H_{\infty}$ synthesis problems fur a descriptor system are presented separately in terms of linear matrix inequalities (LMIs) based on the bounded real lemma. Then, we show that the existence of a mixed $H_2/H_{\infty}$ controller by which the $H_2$ norm of the second channel is minimized while keeping the $H_2$ norm bound of the first channel less than ${\gamma}$, is reduced to the linear objective minimization problem. The class of desired controllers that are assumed to have the same structure as the plant is parameterized by using the linearizing change of variables.

Embedded smart GFRP reinforcements for monitoring reinforced concrete flexural components

  • Georgiades, Anastasis V.;Saha, Gobinda C.;Kalamkarov, Alexander L.;Rokkam, Srujan K.;Newhook, John P.;Challagulla, Krishna S.
    • Smart Structures and Systems
    • /
    • v.1 no.4
    • /
    • pp.369-384
    • /
    • 2005
  • The main objectives of this paper are to demonstrate the feasibility of using newly developed smart GFRP reinforcements to effectively monitor reinforced concrete beams subjected to flexural and creep loads, and to develop non-linear numerical models to predict the behavior of these beams. The smart glass fiber-reinforced polymer (GFRP) rebars are fabricated using a modified pultrusion process, which allows the simultaneous embeddement of Fabry-Perot fiber-optic sensors within them. Two beams are subjected to static and repeated loads (until failure), and a third one is under long-term investigation for assessment of its creep behavior. The accuracy and reliability of the strain readings from the embedded sensors are verified by comparison with corresponding readings from surface attached electrical strain gages. Nonlinear finite element modeling of the smart concrete beams is subsequently performed. These models are shown to be effective in predicting various parameters of interest such as crack patterns, failure loads, strains and stresses. The strain values computed by these numerical models agree well with corresponding readings from the embedded fiber-optic sensors.

Dynamic instability analysis of laminated composite stiffened shell panels subjected to in-plane harmonic edge loading

  • Patel, S.N.;Datta, P.K.;Sheikh, A.H.
    • Structural Engineering and Mechanics
    • /
    • v.22 no.4
    • /
    • pp.483-510
    • /
    • 2006
  • The dynamic instability characteristics of laminated composite stiffened shell panels subjected to in-plane harmonic edge loading are investigated in this paper. The eight-noded isoparametric degenerated shell element and a compatible three-noded curved beam element are used to model the shell panels and the stiffeners respectively. As the usual formulation of degenerated beam element is found to overestimate the torsional rigidity, an attempt has been made to reformulate it in an efficient manner. Moreover the new formulation for the beam element requires five degrees of freedom per node as that of shell element. The method of Hill's infinite determinant is applied to analyze the dynamic instability regions. Numerical results are presented to demonstrate the effects of various parameters like shell geometry, lamination scheme, stiffening scheme, static and dynamic load factors and boundary conditions, on the dynamic instability behaviour of laminated composite stiffened panels subjected to in-plane harmonic loads along the boundaries. The results of free vibration and buckling of the laminated composite stiffened curved panels are also presented.

Parametric resonance of composite skew plate under non-uniform in-plane loading

  • Kumar, Rajesh;Kumar, Abhinav;Panda, Sarat Kumar
    • Structural Engineering and Mechanics
    • /
    • v.55 no.2
    • /
    • pp.435-459
    • /
    • 2015
  • Parametric resonance of shear deformable composite skew plates subjected to non-uniform (parabolic) and linearly varying periodic edge loading is studied for different boundary conditions. The skew plate structural model is based on higher order shear deformation theory (HSDT), which accurately predicts the numerical results for thick skew plate. The total energy functional is derived for the skew plates from total potential energy and kinetic energy of the plate. The strain energy which is the part of total potential energy contains membrane energy, bending energy, additional bending energy due to additional change in curvature and shear energy due to shear deformation, respectively. The total energy functional is solved using Rayleigh-Ritz method in conjunction with boundary characteristics orthonormal polynomials (BCOPs) functions. The orthonormal polynomials are generated for unit square domain using Gram-Schmidt orthogonalization process. Bolotin method is followed to obtain the boundaries of parametric resonance region with higher order approximation. These boundaries are traced by the periodic solution of Mathieu-Hill equations with period T and 2T. Effect of various parameters like skew angle, span-to-thickness ratio, aspect ratio, boundary conditions, static load factor on parametric resonance of skew plate have been investigated. The investigation also includes influence of different types of linearly varying loading and parabolically varying bi-axial loading.

Strength Evaluation of a Doubler Plate of Ship Structure subjected to the In-plane Combined Load and Lateral Pressure Load (면내 조합하중과 횡압을 받는 선박 이중판의 강도 평가)

  • Ham, Juh-Hyeok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.6
    • /
    • pp.37-48
    • /
    • 2003
  • A study for the structural strength evaluation of doubler plates subjected to the in-plane combined load and lateral pressure load has been performed through a systematic evaluation process. In order to properly estimate the static strength of doubler plate, elasto-plastic large deflection analysis is introduced including the contact effect between main plate and doubler. The characteristics of stiffness and strength variation are discussed based on the analysis results. Also, in order to compare the doubler structure with the original strength of main plate without doubler, a simple formula for the evaluation of the equivalent flat plate thickness is derived based on the additional series analysis of fiat plate structure. Using this derived equation, the thickness change of a equivalent flat plate is analyzed according to the variation of various design parameters of doubler plate and some design guides are suggested In order to maintain the original strength of main plate without doubler reinforcement. Finally, correlation between derived equivalent plate thickness formula and the developed buckling strength formulas for intact plates by author et al. is discovered and these relations are formulated for the future development of simple strength evaluation formula of doubler plate structure.

Hydrodynamic Effect on the Inhibition for the Flow Accelerated Corrosion of an Elbow

  • Zeng, L.;Zhang, G.A.;Guo, X.P.
    • Corrosion Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • The inhibition effect of thioureido imidazoline inhibitor (TAI) for flow accelerated corrosion (FAC) at different locations for an X65 carbon steel elbow was studied by array electrode and computational fluid dynamics (CFD) simulations. The distribution of the inhibition efficiency measured by electrochemical impedance spectroscopy (EIS) is in good accordance with the distribution of the hydrodynamic parameters at the elbow. The inhibition efficiencies at the outer wall are higher than those at the inner wall meaning that the lower inhibition efficiency is associated with a higher flow velocity, shear stress, and turbulent kinetic energy at the inner wall of the elbow, as well as secondary flow at the elbow rather than the mass transport of inhibitor molecules. Compared to the static condition, the inhibition efficiency of TAI for FAC was relatively low. It is also due to a drastic turbulence flow and high wall shear stress during the FAC test, which prevents the adsorption of inhibitor and/or damages the adsorbed inhibitor film.

Effects of Virtual Reality Program on Standing Balance in Chronic Stroke Patients (가상현실 프로그램이 만성 뇌졸중 환자의 선자세 균형에 미치는 영향)

  • Kim, Joong-Hwi;Kim, Chung-Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.3
    • /
    • pp.351-367
    • /
    • 2005
  • The purpose of this study was to identity effects of virtual reality(VR) program related to standing postural control on balance, gait and brain activation patterns in chronic hemiplegic stroke patients. Subjects were assigned randomly to either VR group (n=12) or the control group (n=12) when the study began. Both groups received conventional physical therapy for 2 to 3 times per week. In addition to conventional physical therapies, VR group trained 3 types of virtual reality programs using IREX for standing postural control during 4 weeks (4 times/week, 30 minutes/time). Subjects were assessed for static and dynamic balance parameters using BPM, functional balance using Berg Balance Scale related to movement of paretic lower limb before and after 4 weeks of virtual reality training. The results of this study were as follows. 1. Following VR training, VR group demonstrated the marked improvement on dynamic mean balance, anteroposterior limits of stability (AP angle) and mediolateral limits of stability (ML angle). 2. Following VR training, both groups scored higher on Berg Balance Scale. However, a comparison of mean change revealed differences between groups. In conclusion, these data suggest that the postural control training using VR programs improve dynamic and functional balance performance in chronic hemiplegic stroke patients.

  • PDF

Precise pressure sensor using piezoelectric nanocomposites integrated directly in organic field-effect transistors

  • Tien, Nguyen Thanh;Trung, Tran Quang;Seol, Young-Gug;Lee, Nae-Eung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.500-500
    • /
    • 2011
  • With recent advances in flexible and stretchable electronics, the development of physically responsive field-effect transistors (physi-FETs) that are easily integrated with transformable substrates may enable the omnipresence of physical sensing devices in electronic gadgets. However, physical stimuli typically induce whole sensing physi-FET devices under global influences that also cause changes in the parameters of FET transducers, such as channel mobility and dielectric capacitance that prevent proper interpretations of response in sensing materials. Extended-gate structures with isolated stimuli have been used recently in physi-FETs to demonstrate performances of sensing materials only. However, such approaches are limited to prototype researches since isolated stimuli rarely occur in real-life applications. In this report, we theoretically and experimentally demonstrated that integrating piezoelectric nanocomposites directly into flexible organic FETs (OFETs) as gate dielectrics provides a general research direction to physi-FETs with a simple device structure and the capability of precisely investigating functional materials. Measurements with static stimulations, which cannot be performed in conventional systems, exhibited giant-positive d33 values of nanocomposites of barium titanate (BT) NPs and poly (vinylidene fluoride-trifluoroethylene) (P(VDF-TrFE)).

  • PDF

Pressure Measurement in Carpal Tunnel Syndrome : Correlation with Electrodiagnostic and Ultrasonographic Findings

  • Ahn, Seong-Yeol;Hong, Youn-Ho;Koh, Young-Hwan;Chung, Yeong-Seob;Lee, Sang-Hyung;Yang, Hee-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.3
    • /
    • pp.199-204
    • /
    • 2009
  • Objective : This study was done to evaluate the correlation between carpal tunnel pressure (CTP), electrodiagnostic and ultrasonographic findings in patients with carpal tunnel syndrome (CTS). Methods : CTP was measured during endoscopic carpal tunnel release (ECTR) for CTS using Spiegelberg ICP monitoring device with parenchymal type catheter. Neurophysiologic severity and nerve cross sectional area were evaluated using nerve conductive study and ultrasonography (USG) before ECTR in all patients. Results : Tests were performed in a total of 48 wrists in 39 patients (9 cases bilateral). Maximum CTP was $56.7{\pm}19.3$ mmHg ($Mean{\pm}SD$) and $7.4{\pm}3.3$ mmHg before and after ECTR, respectively. No correlation was found between maximum CTP and either neurophysiologic severity or nerve cross sectional area, whereas we found a significant correlation between the latter two parameters. Conclusion : CTP was not correlated with neurophysiologic severity and nerve cross sectional area. Dynamic, rather than static, pressure in carpal tunnel might account for the basic pathophysiology of CTS better.