• 제목/요약/키워드: static electricity

검색결과 133건 처리시간 0.028초

한국의 다목적댐 수력발전 체계-투자의 정당화와 경제적 운영- (A Framework for Investment Justification and Economic Operation-)

  • 이승규;박용삼
    • 한국경영과학회지
    • /
    • 제12권1호
    • /
    • pp.157-157
    • /
    • 1987
  • Hydro-electric power generation from multi-purpose dams has been playing important roles in the electric power supply network in Korea. Although the total share of hydro power in national electricity supply now becomes very small, the peak-shaving and frequency control capability of hydro power helps the power company enormously in maintaining the quality of power. But since the company that builds and operates the multi-purpose dams in Korea has to sell all the electricity produced to the monopolistic utility, there have been various problems in justifying the investment, designing pricing mechanism, and controlling operations of the power plants. In addition, economic evaluation of the hydro power has been distorted by a variety of reasons and hence it has been very difficult to encourage effective development and utilization of national water resources. To make the problem worse, both parties are public companies with X-inefficiency problems. Thus, changing environment requires to reengineer the system that governs hydro power generation. We address the problems of Korean hydro-electric power generation system in four areas: the investment justification process, the operations decison right of the hydro power plants, the pricing of the purchased-power, and the negotiation of contract revision. Then we propose improvement directions of new hydro-electric power system in view of static and dynamic efficiency, X-inefficiency and equity.

한국의 다목적댐 수력발전 체계 - 투자의 정당화와 경제적 운영 - (Hydro-electric Power Generation System of Multi-purpose Dams in Koresa - A Framework for Investment Justification and Economic Operation -)

  • 이승규;박용삼
    • 경영과학
    • /
    • 제12권1호
    • /
    • pp.157-173
    • /
    • 1995
  • Hydro-electric power generation from multi-purpose dams has been playing important roles in the electric power supply network in Korea. Although the total share of hydro power in national electricity supply now becomes very small, the peak-shaving and frequency control capability of hydro power helps the power company enormously in maintaining the quality of power. But since the company that builds and operates the multi-purpose dams in Korea has to sell all the electricity produced to the monopolistic utility, there have been various problems in justifying the investment, designing pricing mechanism, and controlling operations of the power plants. In addition, economic evaluation of the hydro power has been distorted by a variety of reasons and hence it has been very difficult to encourage effective development and utilization of national water resources. To make the problem worse, both parties are public companies with X-inefficiency problems. Thus, changing environment requires to reengineer the system that governs hydro power generation. We address the problems of Korean hydro-electric power generation system in four areas: the investment justification process, the operations decison right of the hydro power plants, the pricing of the purchased-power, and the negotiation of contract revision. Then we propose improvement directions of new hydro-electric power system in view of static and dynamic efficiency, X-inefficiency and equity.

  • PDF

Galloping analysis of stranded electricity conductors in skew winds

  • Macdonald, J.H.G.;Griffiths, P.J.;Curry, B.P.
    • Wind and Structures
    • /
    • 제11권4호
    • /
    • pp.303-321
    • /
    • 2008
  • When first commissioned, the 1.6 km span 275kV Severn Crossing Conductor experienced large amplitude vibrations in certain wind conditions, but without ice or rain, leading to flashover between the conductor phases. Wind tunnel tests undertaken at the time identified a major factor was the lift generated in the critical Reynolds number range in skew winds. Despite this insight, and although a practical solution was found by wrapping the cable to change the aerodynamic profile, there remained some uncertainty as to the detailed excitation mechanism. Recent work to address the problem of dry inclined cable galloping on cable-stayed bridges has led to a generalised quasi-steady galloping formulation, including effects of the 3D geometry and changes in the static force coefficients in the critical Reynolds number range. This generalised formulation has been applied to the case of the Severn Crossing Conductor, using data of the static drag and lift coefficients on a section of the stranded cable, from the original wind tunnel tests. Time history analysis has then been used to calculate the amplitudes of steady state vibrations for comparison with the full scale observations. Good agreement has been obtained between the analysis and the site observations, giving increased confidence in the applicability of the generalised galloping formulation and providing insight into the mechanism of galloping of yawed and stranded cables. Application to other cable geometries is also discussed.

부하모델에 따른 한전계통의 정적인 전압불안정점의 변화에 관한 연구 (A Study on Change of Static Voltage Instability Point Related to Load Model in the KEPCO System)

  • 송화창;송태용;정문구;이석창;최건수;최선규;조윤성;이병준;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.319-321
    • /
    • 2000
  • Today's power systems operate near their stability limit and numerous incidents closely related to voltage instability phenomena have been reported. In addition. a world-wide fashion towards restructuring in electricity industry can worsen the trend of voltage instability. In this environment, finding exact voltage instability points of practical power systems is a main concern of power system engineers. This paper reports change of static voltage instability point with respect to various load model in the KEPCO system.

  • PDF

철도 부하의 이동성을 반영한 변전소 정태부하모델링 수립에 대한 연구 (A Study on a Substation Static Load Model Including the Mobility of a Railway Load)

  • 창상훈;윤석민;김정훈
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.315-323
    • /
    • 2015
  • Nowadays, it is expected that mobility loads such as electric railways and electric vehicles will be penetrated gradually and affect on the power system stability by their load characteristics. Various researches have been carried out about electric vehicles for the recent decade though the load of electric railway could be forecasted because of the specified path and timetable, is a field with a long historic background. Some precise 5th polynomial equations are required to analyze the power system stability considering mobility load to be increased in the immediate future while the electric railway dispatching simulator uses load models with constant power and constant impedance for the system analysis. In this paper, seasonal urban railway load models are established as the form of 5th polynomial equations and substation load modeling methods are proposed merging railway station load models and general load models. Additionally, load management effects by the load modeling are confirmed through the case studies, in which seasonal load models are developed for Seoul Subway Line No. 2, Gyeongui Line and Airport Railroad and the substation load change is analyzed according to the railway load change.

Comparative Study of P-T Limit Curves between 1998 ASME and 2017 ASME Code Applied to Typical OPR1000 Reactors

  • Maragia, Joswhite Ondabu;Namgung, Ihn
    • 한국압력기기공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.1-8
    • /
    • 2019
  • The integrity of the Reactor Pressure Vessel (RPV) is affected by the neutrons bombarding the vessel wall leading to embrittlement. This irradiation-induced embrittlement leads to reduction in the fracture toughness of RPV materials. This paper presents a comparative study of typical Optimized Power Reactor (OPR)1000 reactor pressure-temperature (P-T) limit curves using the pre-2006 American Society of Mechanical Engineers (ASME) editions used in the power plant and the current ASME edition of 2010. The current ASME Code utilizes critical reference stress intensity factor based on the lower bound of static, while the Pre-2006 ASME editions are based the critical reference stress intensity factor based on the lower bound of static, dynamic and crack arrest. Model-Based Systems Engineering approach was used to evaluate ASME Code Section XI Appendix G for generating the P-T limit curves. The results obtained from this analysis indicate decrease in conservatism in P-T limit curves constructed using the current 2017 ASME code, which can potentially increase operational flexibility and plant safety. Hence it is recommended to use ASME code edition after 2006 be used in all operating nuclear power plants (NPPs) to establish P-T limit curve.

초고압 불평등 전계에서 정전링 설계변수에 대한 연구 (A Study on the Design Parameters of the Static Ring in the Ultra-high Voltage Non-uniform Electric Field)

  • 김진성;서민성
    • 한국산학기술학회논문지
    • /
    • 제21권7호
    • /
    • pp.577-582
    • /
    • 2020
  • 발전소에서 생산된 전기는 여러 단계의 변전과정을 거쳐 소비자에게 전달된다. 이 때 각 소비자에게 적합한 전압으로 송전하기 위해 초기 송전단계 및 산업단지 및 공장과 같은 고전압이 필요한 경우에 사용되는 초고압변압기는 권선 단부에서 고압의 불평등 전계가 형성되어 절연파괴의 위험을 내재하고 있다. 초고압변압기는 전압의 승압과 강압을 위해 권선, 철심이 가장 중요한 부품이다. 특히 권선의 경우 전압이 직접 인가되면서 전압의 크기를 변환하는데 핵심적인 역할을 한다. 이때 권선 단부는 그 형상에 의해 불평등 전계가 형성되고 특히 권선의 모서리에 높은 전계 스트레스가 발생한다. 이러한 불평등 전계에 의한 권선 단부의 전기적 응력을 분산하기 위하여 정전링을 사용하는데 이 정전링은 권선 상·하단 단부에 설치된다. 이러한 정전링을 설계하기 위해서는 다양한 변수를 고려하여야 하지만 그 중 정전링 곡률, 정전링 표면의 절연지 두께, 권선과 권선사이에 설치되는 배리어 수, 배리어 두께가 정전링에 발생되는 전계 스트레스에 어떠한 영향을 미치는지 유한요소법(Finite Element Method)을 통해 확인하였고 그 결과를 통해 정전링 설계 시 고려해야 할 사항을 제안하였다.

Mechanical properties of steel-polypropylene fiber reinforced fully recycled coarse aggregate concrete

  • Weiwei Su;Zongping Chen;Haoyu Liao;Dingyuan Liu;Xingyu Zhou
    • Advances in concrete construction
    • /
    • 제16권3호
    • /
    • pp.127-139
    • /
    • 2023
  • In this study, the steel fiber and the polypropylene fiber were used to enhance the mechanical properties of fully recycled coarse aggregate concrete. Natural crushed stone was replaced with recycled coarse aggregate at 100% by volume. The steel fiber and polypropylene fiber were used as additive material by incorporating into the mixture. In this test two parameters were considered: (a) steel fiber volume ratio (i.e., 0%, 1%, 1.5%, 2%), (b) polypropylene fiber volume ratio (i.e., 0%, 0.1%, 0.15%, 0.2%). The results showed that compared with no fiber, the integrity of cubes or cylinders mixed with fibers after failure was better. When the volume ratio of steel fiber was 1~2%, the width of mid-span crack after flexural failure was 5~8 mm. In addition, when the volume ratio of polypropylene fiber was 0.15%, with the increase of steel fiber content, the static elastic modulus and toughness of axial compression first increased and then decreased, and the flexural strength increased, with a range of 6.5%~20.3%. Besides, when the volume ratio of steel fiber was 1.5%, with the increase of polypropylene fiber content, the static elastic modulus decreased, with a range of 7.0%~10.5%. The ratio of axial compression toughness first increased and then decreased, with a range of 2.2%~8.7%. The flexural strength decreased, with a range of 2.7%~12.6%. On the other hand, the calculation formula of static elastic modulus and cube compressive strength of fully recycled coarse aggregate with steel-polypropylene fiber was fitted, and the optimal fiber content within the scope of the test were put forward.

자초염색 직물의 물성 연구 (A Study on the Physical Properties of Cromwell-dyed Fabrics)

  • 최인려;최정임
    • 한국의상디자인학회지
    • /
    • 제4권1호
    • /
    • pp.99-110
    • /
    • 2002
  • This study is performed to investigate the effect of the mordant and chitosan on the colorfastness to laundering and physical properties of the mordanted, chitosan treated and natural - dyed cotton, silk and acrylics substrates. Natural dyes are extracted from Gromwell by boiled water. Three different compounds of Al, Cu, Sn and Chitosan are used as mordanting agents. The result of this study is summarized as follows: 1. Color of the fabrics dyed with Gromwell changes redder, bluer and darker after chitosan treated and mordanting. 2. After washing, the color of natural dyes changes more light and gray, Chitosan and Cu mordanting gives better colorfastness in washing than any others. 3. All chitosan treated fabrics improve air permeability. 4. In the chitosan treated fabrics, a half life of the static electricity is shown good result.

  • PDF

수용성고분자와 아민을 이용한 내구성 대전방지제 개발에 관한 연구 (A Study on the Synthesis of Durable Antistatic Agent Using Water Soluble Polymers and Amines)

  • 박성우;이석영;서말용;서장혁;신용섭;구강
    • 한국염색가공학회지
    • /
    • 제13권6호
    • /
    • pp.413-427
    • /
    • 2001
  • In this studs, we synthesized durable antistatic agents with acrylic monomers for preventing the electrification of static electricity which is one of defects of polyester fabrics. Also we synthesized quaternary ammonium salts which give antistatic property and crosslinking agents which make antistatic agents adhere to fiber. The treatment of synthesized antistatic agents on polyester fabric carried out at the condition of various concentrations, treatment times and temperatures. The antistatic property, handle characteristics and other properties of treated and untreated polyester fabrics were also investigated.

  • PDF