• Title/Summary/Keyword: static cyclic loading

Search Result 248, Processing Time 0.024 seconds

A Study on Plastic Zone at the Crack Tip under Cyclic Loading by FEM (유한요소법을 이용한 피로하중을 받는 균열선단의 소성영역크기에 대한 연구)

  • Kim, Kyung-Su;Shim, Chun-Sik;Lee, Wook-Jae;Cho, Hyung-Min
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.151-154
    • /
    • 2002
  • In this paper, the effect of the crack growth length on the plastic zone size at the crack tip and the crack growth lives of the DENT specimen under constant amplitude cyclic loading were studied. The plastic zone size was calculated by nonlinear static method in commercial finite element analysis program, MSC/NASTRAN and the crack growth lives were also calculated by using compliance function considering geometric shape in MSC/FATIGUE. The calculated plastic zone size increased proportional to the crack length. And comparison of calculated plastic zone size and crack growth lives with the experimental results shows a good agreement.

  • PDF

Taming of large diameter triaxial setup

  • Nair, Asha M.;Madhavi Latha, G.
    • Geomechanics and Engineering
    • /
    • v.4 no.4
    • /
    • pp.251-262
    • /
    • 2012
  • Triaxial tests are essential to estimate the shear strength properties of the soil or rock. Normally triaxial tests are carried out on samples of 38 mm diameter and 76 mm height. Granular materials, predominantly used in base/sub-base construction of pavements or in railways have size range of 60-75 mm. Determination of shear strength parameters of those materials can be made possible only through triaxial tests on large diameter samples. This paper describes a large diameter cyclic triaxial testing facility set up in the Geotechnical Engineering lab of Indian Institute of Science. This setup consists of 100 kN capacity dynamic loading frame, which facilitates testing of samples of up to 300 mm diameter and 600 mm height. The loading ram can be actuated up to a maximum frequency of 10 Hz, with maximum amplitude of 100 mm. The setup is capable of carrying out static as well as dynamic triaxial tests under isotropic, anisotropic conditions with a maximum confining pressure of 1 MPa. Working with this setup is a difficult task because of the size of the sample. In this paper, a detailed discussion on the various problems encountered during the initial testing using the equipment, the ideas and solutions adopted to solve them are presented. Pilot experiments on granular sub-base material of 53 mm down size are also presented.

Hysteretic behavior of perforated steel plate shear walls with beam-only connected infill plates

  • Shekastehband, Behzad;Azaraxsh, Ali A.;Showkati, Hossein
    • Steel and Composite Structures
    • /
    • v.25 no.4
    • /
    • pp.505-521
    • /
    • 2017
  • The steel plate shear wall with beam-only connected infill plate (SSW-BO) is an innovative lateral load resisting system consisting of infill plates connected to surrounding beams and separated from the main columns. In this research, the effects of perforation diameter as well as slenderness ratios of infill plates on the hysteresis behavior of SSW-BO systems were studied experimentally. Experimental testing is performed on eight one-sixth scaled one-story SSW-BO specimens with two plate thicknesses and four different circular opening ratios at the center of the panels under fully reversed cyclic quasi-static loading in compliance with the SAC test protocol. Strength, stiffness, ductility and energy absorption were evaluated based on the hysteresis loops. It is found that the systems exhibited stable hysteretic behavior during testing until significant damage in the connection of infill plates to surrounding beams at large drifts. It is also seen that pinching occurred in the hysteresis loops, since the hinge type connections were used as boundaries at four corners of surrounding frames. The strength and initial stiffness degradation of the perforated specimens containing opening ratio of 0.36 compared to the solid one is in the range of 20% to 30% and 40% to 50%, respectively.

Evaluation for Fatigue Life of Rubber Isolator for Vibration Characteristic on Automotive Cooling Module (진동 특성을 고려한 자동차 냉각모듈 방진고무의 내구성 평가)

  • Shim, Hee-Jin;Kim, Han-Chul;Kim, Jung-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.350-355
    • /
    • 2008
  • A Rubber mount is widely used for mechanical parts or engineering materials. Especially, it plays an important role in reducing mechanical vibration due to cyclic loading. But, rubber mount is damaged due to the cyclic loading and resonance. Therefore, it is necessary to investigate evaluation of fatigue life considering vibration characteristics for rubber. In this study, a vibration fatigue analysis was performed and based on Power Spectral Density(PSD) and the stress-life curve and a result of frequency response analysis in the finite element method. The measured load history in experiment was transformed to PSD curve. The stress-life curve was obtained by nonlinear static analysis and fatigue test. In addition, frequency response analysis was conducted for mechanical part. In order to evaluate fatigue life of rubber mount, vibration fatigue test was conducted at the constant acceleration-level as well. Fatigue life was determined when the load capacity is reduced to 60% of its initial value. As a result, predicted fatigue life of rubber mount agreed fairly well with the experimental fatigue life.

  • PDF

Fatigue Strength of Composite Joint Structures Reinforced by Jagged Shaped Stainless Steel Z-pins (요철 형상의 스테인레스강 Z-핀으로 보강된 복합재 접합 구조물의 피로강도)

  • Choi, Ik-Hyeon;Lim, Cheol-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.12
    • /
    • pp.967-974
    • /
    • 2013
  • Recently the authors had proposed the z-pinning patch concept to simply manufacture z-pinned composite structures at industrial production site and manufactured composite single-lap shear joint specimens using the concept. Through static tensile test on the specimens they had obtained 54~68% improvement of the joint strength. As a sequential study of it, in this study, fatigue test has performed to measure an improvement of joint strength under cyclic loading. The z-pin's material is stainless steel and its surface was specially machined into zagged shapes and chemically corroded to increase the connection force with composite materials. Approximately 98~125% improvement of the joint strength under cyclic loading was obtained.

Experimental study on seismic performance of partial penetration welded steel beam-column connections with different fillet radii

  • Ge, Hanbin;Jia, Liang-Jiu;Kang, Lan;Suzuki, Toshimitsu
    • Steel and Composite Structures
    • /
    • v.17 no.6
    • /
    • pp.851-865
    • /
    • 2014
  • Full penetration welded steel moment-resisting frame (SMRF) structures with welded box sections are widely employed in steel bridges, where a large number of steel bridges have been in operation for over fifty years in Japan. Welding defects such as incomplete penetration at the beam-column connections of these existing SMRF steel bridge piers were observed during inspection. Previous experiments conducted by the authors' team indicate that gusset stiffeners (termed fillets in this study) at the beam-web-to-column-web joint of the beam-column connections may play an important role on the seismic performance of the connections. This paper aims to experimentally study the effect of the fillet radius on seismic performance of the connections with large welding defects. Four specimens with different sizes of fillet radii were loaded under quasi-static incremental cyclic loading, where different load-displacement relations and cracking behaviors were observed. The experimental results show that, as the size of the fillet radius increases, the seismic performance of the connections can be greatly improved.

Plastic deformation characteristics of disintegrated carbonaceous mudstone under dynamic loading

  • Qiu, Xiang;Yin, Yixiang;Jiang, Huangbin;Fu, Sini;Li, Jinhong
    • Geomechanics and Engineering
    • /
    • v.31 no.1
    • /
    • pp.87-97
    • /
    • 2022
  • The excessive settlement and deformation of disintegrated carbonaceous mudstone (DCM) embankments under dynamic loading have long been problems for engineers and technicians. In this work, the characteristics and mechanism of the plastic deformation of DCM under different degrees of compaction, water contents and confining pressures were studied by static triaxial, dynamic triaxial and scanning electron microscopy testing. The research results show that the axial stress increases with increasing confining pressure and degree of compaction and decreases with increasing water content when DCM failure. The axial strain at failure of the DCM decreases with increasing confining pressure and degree of compaction and increases with increasing water content. Under cyclic dynamic stress, the change in the axial stress level of the DCM can be divided into four stages: the stable stage, transition stage, safety reserve stage and unstable stage, respectively. The effects of compaction, water content and confining pressure on the critical axial stress level which means shakedown of the DCM are similar. However, an increase in confining pressure reduces the effects of compaction and water content on the critical axial stress level. The main deformation of DCM is fatigue cracking. Based on the allowable critical axial stress, a method for embankment deformation control was proposed. This method can determine the degree of compaction and fill range of the embankment fill material according to the equilibrium moisture content of the DCM embankment.

Inelastic behavior of standard and retrofitted rectangular hollow sectioned struts -I: Analytical model

  • Boutros, Medhat K.
    • Structural Engineering and Mechanics
    • /
    • v.10 no.5
    • /
    • pp.491-504
    • /
    • 2000
  • This paper is a presentation of a physical model for the elastic-partly plastic behavior of rectangular hollow section pinned struts subjected to static cyclic axial loading and the evaluation of the compressive strength of retrofitted damaged struts. Retrofitting is achieved by welding stiffening plates along the webs of damaged struts. The shape of the elastic and permanent deformations of the strut axis satisfy the conditions at the ends and midspan. Continuous functions of the geometric variables of stress distributions in the yielded zone are evaluated by interpolation between three points along each partly plastic zone. Permanent deformations of the partly plastic region are computed and used to update the shape of the unloaded strut. The necessity of considering geometric nonlinearity is discussed. The sensitivity of the results to the location of interpolation points, the shape of the permanent deformation and material hysteretic properties is investigated.

Inelastic behavior of standard and retrofitted rectangular hollow sectioned struts -II: Experimental study

  • Boutros, Medhat;McCulloch, James;Scott, Damian
    • Structural Engineering and Mechanics
    • /
    • v.10 no.5
    • /
    • pp.505-516
    • /
    • 2000
  • This paper is a presentation of an experimental study about the elastic-partly plastic behavior of rectangular hollow steel pinned struts subjected to static cyclic axial loading and the evaluation of the compressive strength of retrofitted crooked struts. Retrofitting is achieved by welding stiffening plates along the webs of damaged struts. The material follows a quasi-kinematic hardening hysteresis path as observed from coupon tests. Test results are compared to those of an analytical model showing a good agreement for both standard and retrofitted struts. The comparison of different stiffener plate dimensions shows that more efficient strengthening is achieved by using long thin stiffeners rather than short thick ones.

A correction method for objective seismic damage index of reinforced concrete columns

  • Kang, Jun Won;Lee, Jeeho
    • Computers and Concrete
    • /
    • v.21 no.6
    • /
    • pp.741-748
    • /
    • 2018
  • In this paper, the sensitivity of a plastic-damage-based structural damage index on mesh density is studied. Multiple finite element meshes with increasing density are used to investigate their effect on the damage index values calculated from nonlinear finite element simulations for a reinforced concrete column subjected to cyclic loading. With the simulation results, this paper suggests a correction method for the objective damage index based on nonlinear regression of volumetric tensile damage ratio data. The modified damage index values are presented in the quasi-static cyclic simulation to show the efficacy of the suggested correction method.