• Title/Summary/Keyword: static code analysis

Search Result 374, Processing Time 0.029 seconds

Nonlinear analysis of 3D reinforced concrete frames: effect of section torsion on the global response

  • Valipour, Hamid R.;Foster, Stephen J.
    • Structural Engineering and Mechanics
    • /
    • v.36 no.4
    • /
    • pp.421-445
    • /
    • 2010
  • In this paper the formulation of an efficient frame element applicable for nonlinear analysis of 3D reinforced concrete (RC) frames is outlined. Interaction between axial force and bending moment is considered by using the fibre element approach. Further, section warping, effect of normal and tangential forces on the torsional stiffness of section and second order geometrical nonlinearities are included in the model. The developed computer code is employed for nonlinear static analysis of RC sub-assemblages and a simple approach for extending the formulation to dynamic cases is presented. Dynamic progressive collapse assessment of RC space frames based on the alternate path method is undertaken and dynamic load factor (DLF) is estimated. Further, it is concluded that the torsional behaviour of reinforced concrete elements satisfying minimum standard requirements is not significant for the framed structures studied.

Seismic fragility curves of single storey RC precast structures by comparing different Italian codes

  • Beilic, Dumitru;Casotto, Chiara;Nascimbene, Roberto;Cicola, Daniele;Rodrigues, Daniela
    • Earthquakes and Structures
    • /
    • v.12 no.3
    • /
    • pp.359-374
    • /
    • 2017
  • The seismic events in Northern Italy, May 2012, have revealed the seismic vulnerability of typical Italian precast industrial buildings. The aim of this paper is to present a seismic fragility model for Italian RC precast buildings, to be used in earthquake loss estimation and seismic risk assessment by comparing two building typologies and three different codes: D.M. 3-03-1975, D.M. 16-01-1996 and current Italian building code that has been released in 2008. Based on geometric characteristics and design procedure applied, ten different building classes were identified. A Monte Carlo simulation was performed for each building class in order to generate the building stock used for the development of fragility curves trough analytical method. The probabilistic distributions of geometry were mainly obtained from data collected from 650 field surveys, while the material properties were deduced from the code in place at the time of construction or from expert opinion. The structures were modelled in 2D frameworks; since the past seismic events have identified the beam-column connection as the weakest element of precast buildings, two different modelling solutions were adopted to develop fragility curves: a simple model with post processing required to detect connection collapse and an innovative modelling solution able to reproduce the real behaviour of the connection during the analysis. Fragility curves were derived using both nonlinear static and dynamic analysis.

A Study on the Selection of Test Scope and the Prioritization of Test Case Based on Modification Method for Regression Testing (변경 메서드 기반의 회귀 테스트 검증 범위 선택 및 검증 항목 우선순위 선정에 관한 연구)

  • Jung, Woo-Jin;Rah, Sang-Rin;Choi, Yong-Lak
    • Journal of Information Technology Services
    • /
    • v.14 no.2
    • /
    • pp.129-142
    • /
    • 2015
  • The purpose of this study is to suggest an effective regression testing method in order to minimize the scope of test resulting from the modification of software and to prevent mismatch of test case and test objects. As a way to improve the efficiency of regression testing which uses a change-centric testing technique, the method flow is analyzed and grasped through a static analysis based on source code in order to identify modified parts. After the order of priority is set according to the results of user action log-based dynamic analysis on identified regression testing objects, test effect can be raised by adjusting the order of priority using code complexity. Quality assurance coverage can be checked using the user action log suggested in this study, and the progress of test and whether or not each function has been verified can be checked, too. In addition, by minimizing test parts and adjusting the order of test, costs and time can be saved, making it possible to conduct regression testing effectively.

The investigation of seismic performance of existing RC buildings with and without infill walls

  • Dilmac, Hakan;Ulutas, Hakan;Tekeli, Hamide;Demir, Fuat
    • Computers and Concrete
    • /
    • v.22 no.5
    • /
    • pp.439-447
    • /
    • 2018
  • One of the important factors is the infill walls in the change of the structural rigidity, ductility, dynamic and static characteristics of the structures. The infill walls are not generally included in numerical analysis of reinforced concrete (RC) structural system due to lack of suitable theory and the difficulty of calculating the recommended models. In seismic regions worldwide, the residential structures are generally RC buildings with infill wall. Therefore, understanding the contribution of the infill walls to seismic performance of buildings may have a vital importance. This paper investigates the effects of infill walls on seismic performance of the existing RC residential buildings by considering requirements of the Turkish Earthquake Code (TEC). Seismic performance levels of residential RC buildings with and without walls in high-hazard zones were determined according to the nonlinear procedure given in the code. Pushover curves were obtained by considering the effect of masonry infill walls on seismic performance of RC buildings. The analysis results showed that the infill walls beneficially effected to the rigidity, roof displacements and seismic performance of the building.

A Study on the Seismic Response Formula for Improvement of Seismic Design Code of Water Treatment Underground Structures (수처리 지중구조물의 내진설계 기준 개선을 위한 지진 응답 제안식의 관한 연구)

  • Lee, Joung-Bae;Bae, Sang-Soo;Chung, Kwang-Mo;Bang, Myung-Seok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.3
    • /
    • pp.41-48
    • /
    • 2022
  • Generally it was known that member forces in the earthquake resistant design is lower than those in the general design. But it is not true in cases of water treatment underground structures, which is different in each case like water treatment plant, sedimentation basin, and utility-pipe conduit. Also, looking at the scale of earthquakes that have recently occurred in Korea, large-scale earthquakes are frequent, so when the magnitude of the design seismic force increases, it is necessary to investigate the seismic behavior of the water treatment underground structure and to deal with it. In this study the change rate of member forces was investigated by the change of design load factor (earthquake acceleration design criteria), earth depth, underground water level. The pseudo-static analysis and response displacement method was applied, and various analyzes were conducted depending on the ground water and soil depth. The proposed formula in this study will be efficient when the earthquake design code of water treatment underground structures is revised.

A Simulation on the Thermal and Fluid about Motorcycle Muffler (모터사이클 머플러 내부 열.유동에 관한 시뮬레이션)

  • Yi, Chung-Seub;Ji, Myoung-Kuk;Shim, Kyu-Jin;Chung, Han-Shik;Lee, Cheol-Jae;Bae, Jae-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2642-2647
    • /
    • 2007
  • This study represents numerical study on the thermal and fluid flow characteristics of exhaust gas in a motorcycle muffler. The reference engine was used 124.cc small displacement. Numerical analysis with computational fluid dynamics(CFD) was carried out to investigate the exhaust gas that flow into a motorcycle muffler. The STAR-CD S/W used to three dimensional steady state CFD analysis in a muffler. And than We got the information of static pressure it is used to structural analysis ant the first baffle plate using the commercial CAE code ANSYS workbench. Exhaust gas flow third chamber from frist chamber and running second chamber. A simulation result shows that each chamber of muffler temperature is about 460 K, 445 and 463K and pressure is about 22,000 Pa, 16,000 Pa and 10,000 Pa.

  • PDF

Seismic assessment of a R/C strategic existing building

  • Mehani, Youcef;Kibboua, Abderrahmane
    • Structural Engineering and Mechanics
    • /
    • v.26 no.6
    • /
    • pp.617-634
    • /
    • 2007
  • Algeria is a country with a high seismic activity. During the last decade, many destructive earthquakes occurred, particularly in the northern part, causing enormous losses in human lives, buildings and equipments. In order to reduce this risk in the capital and avoid serious damages to the strategic existing buildings, the government decided to invest into seismic upgrade, strengthening and retrofitting of these buildings. In doing so, seismic vulnerability study of this category of buildings has been considered. Structural analysis is performed on the basis of site investigation (inspection of the building, collecting data, materials, general conditions of the building, etc), and existing drawings (architectural plans, structural design, etc). The aim of these seismic vulnerability studies is to develop guidelines and a methodology for rehabilitation of existing buildings. This paper will provide insight to the vulnerability assessment and strengthening of the telecommunication centre, according to the new code RPA 99/version 2003. Both, static equivalent method and non linear dynamic analysis are performed in this study.

A CFD Analysis of the Oil Flow in a Hydraulic Shock Absorber (유압 완층기 내에서의 오일 유동에 대한 CFD 해석)

  • Park, K.T.;Park, T.J.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.20-26
    • /
    • 2008
  • Various types of hydraulic shock absorbers are widely used in many fields because of its numerous advantages. However, in order to design adequate damping characteristics, accurate flow data near the orifices are required essentially. In this paper, a commercial computational fluid dynamics(CFD) code, FLUENT is adopted to investigate the flow characteristics near orifices of a shock absorber. Static pressure and velocity vector distributions, fluid path lines are presented for compression/tension strokes and various piston speeds. In order to validate the result of analysis, the numerically obtained damping forces are compared with those of analytical estimations obtained by modified Bernoulli equation. The results reported herein will provide better understanding of the detailed flow fields within shock absorber, and the CFD analysis method proposed in this paper can be used in the design of other types of hydraulic shock absorber.

  • PDF

Computation of Stress Field During Additive Manufacturing by Explicit Finite Element Method (외연적 유한요소법을 이용한 적층제조 공정 중 응력 장 변화 계산)

  • Yang, Seung-Yong;Kim, Jeoung Han
    • Journal of Powder Materials
    • /
    • v.27 no.4
    • /
    • pp.318-324
    • /
    • 2020
  • In the present work, an explicit finite element analysis technique is introduced to analyze the thermal stress fields present in the additive manufacturing process. To this purpose, a finite element matrix formulation is derived from the equations of motion and continuity. The developed code, NET3D, is then applied to various sample problems including thermal stress development. The application of heat to an inclusion from an external source establishes an initial temperature from which heat flows to the surrounding body in the sample problems. The development of thermal stress due to the mismatch between the thermal strains is analyzed. As mass scaling can be used to shorten the computation time of explicit analysis, a mass scaling of 108 is employed here, which yields almost identical results to the quasi-static results.

Performance Analysis of CZZ Codes Using Degree-2 Polynomial Interleavers for Fading Channels (페이딩 채널에서 2차 다항식 인터리버를 사용한 CZZ 부호의 성능 분석)

  • Yun, Jeong-Kook;Yoo, Chul-Hae;Shin, Dong-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.12C
    • /
    • pp.1006-1013
    • /
    • 2008
  • CZZ (Concatenated Zigzag) Code is a class of fast encodable LDPC codes. In the case that LDPC codes including CZZ codes have short length, short cycles seriously affect the code performance. In this paper, we construct CZZ codes using various degree-2 polynomial interleavers which eliminate cycles of length 4 and through simulation, compare the performance of these CZZ codes and turbo codes in many different fading channels. Especially, quasi-static fading channel, block fading channel, uncorrelated fading channel, and correlated fading channel are considered. Since CZZ codes show similar performance as turbo codes, they can be used in the next generation wireless communication systems.