• Title/Summary/Keyword: static chamber

Search Result 157, Processing Time 0.024 seconds

Investigation of Nonlinear Numerical Mathematical Model of a Multiple Shaft Gas Turbine Unit

  • Kim, Soo-Yong;Valeri P. Kovalevsky
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2087-2098
    • /
    • 2003
  • The development of numerical mathematical model to calculate both the static and dynamic characteristics of a multi-shaft gas turbine consisting of a single combustion chamber, including advanced cycle components such as intercooler and regenerator is presented in this paper. The numerical mathematical model is based on the simplified assumptions that quasi-static characteristic of turbo-machine and injector is used, total pressure loss and heat transfer relation for static calculation neglecting fuel transport time delay can be employed. The supercharger power has a cubical relation to its rotating velocity. The accuracy of each calculation is confirmed by monitoring mass and energy balances with comparative calculations for different time steps of integration. The features of the studied gas turbine scheme are the starting device with compressed air volumes and injector's supercharging the air directly ahead of the combustion chamber.

Evaluation of Pile Bearing Capacity using Calibration Chamber Test (모형토조실험을 통한 말뚝지지력의 평가)

  • 이인모;이명환
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1992.03a
    • /
    • pp.13-40
    • /
    • 1992
  • Static formulae based on limiting equilibrium theories often provide misleading predictions of pile bearing capacity in cohesionless soils due to the incorrect basic assumptions or oversimplification of actual soil conditions. Soil conditions prior to pile driving are significantly changed after pile installation and imposition of high stress levels. Therefore soi1 parameters at failure rather than those obtained at initial conditions should be used in application of static formulae. In this research. model pile test data were analyzed and compared with the predicted values obtained from the various static formulae. The results showed that the proper choice of soil parameters remarkably improve the reliability of static formulae.

  • PDF

The Effect of Air Vent Holes and Stacking Methods of Fruits and Vegetables Boxes on Static Pressure Drop in Pressure Cooling System (청과물상자의 통기공 및 상자적재방법이 정압강하에 미치는 영향)

  • 김의웅;김병삼;남궁배;정진웅;김동철;금동혁
    • Journal of Biosystems Engineering
    • /
    • v.20 no.4
    • /
    • pp.360-367
    • /
    • 1995
  • The effect of air vent holes, stacking methods of boxes and clearance between boxes on static pressure drop, were measured to design of pressure cooling system. Static pressure drops in air vent hole of carton box were measured for different hole opening ratio from 1% to 5%. Static pressure drop was expressed as a function of superficial velocity as second-degree polynomial. At given static pressure in plenum chamber, static pressure drop in boxes was shown as second-degree polynomial of the number of carton box in series stacking method, as first-degree polynomial in height and parallel stacking method. In pressure cooling of 24 boxes of Tsugaru apple, air flow rates through clearance between the boxes were shown 1.27 and 1.65 times than those of through the inside of boxes at the plenum pressure of 10mmAq and 20mmAq, respectively.

  • PDF

The Influence of Dry Etching Process by Charged Static Electricity on LCD Glass

  • Kim, Song-Kwan;Yun, Hae-Sang;Hong, Mun-Pyo;Park, Sun-Woo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.77-78
    • /
    • 2000
  • We verified the charged static electricity on LCD glass influences upon the etching uniformity of dry etching process by plasma. In the TFT-LCD manufacturing process, we mainly paid attention to eliminate the static electricity for TFT reliability. The static electricity caused the serious ununiformity of etching surface profile and etching rate in the dry etch process. Through our experiment on the made static electricity from -200V to -1000V, it was confirmed that the static electricity on LCD glass caused the etching rate variation of $1.5%{\sim}15%$. We recommend the etching process equipment for LCD manufacturing have to establish the soft X-ray exposure module system for eliminating the static electricity inside the loading and unloading chamber.

  • PDF

The Influence of the Supply Chamber Configuration on Under-Expanded Swirling Jets (노즐 챔버 형상이 부족팽창 스월제트 유동에 미치는 영향에 관한 연구)

  • Kim, Jung-Bae;Lee, Kwon-Hee;Setoguchi, Toshiaki;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.586-591
    • /
    • 2003
  • The present study addresses experimental results to investigate the effect of the jet supply chamber configuration on the sonic/supersonic swirling jets, as the case study. The experiment is carried out using the convergent nozzle with a various different chamber configurations upstream the nozzle throat, which is composed of four tangential inlet holes for the swirling flows. The jet pressure ratio is varied between 3.0 and 7.0. The sonic/supersonic swirling jet flows are specified by the pitot impact and static pressure measurements and visualized using the Shadowgraph method. The results show that the major structures of the sonic/supersonic swirling jet are strongly influenced by the jet supply chamber.

  • PDF

Characteristics of the Transient Pressure in a Building Water Supply System with an Air Chamber (공기실이 설치된 건축물 급수관로의 과도압력 특성)

  • 황희성;임기원;이광복;조병선;차동진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.782-790
    • /
    • 2000
  • A numerical study has been conducted to characterize the transient pressure in a building water supply system with an air chamber by utilizing a commercial code that employs the method of characteristics. Some results produced for the purpose of verification in the study agree quite well with the previously reported. Several parameters are then varied. Among them are the valve closure time, the wave speed, the static pressure, the polytropic exponent, the air chamber volume, the inner diameter and the shape of orifice in the air chamber, etc, while the water temperature and velocity are kept constant at $20^P{circ}C $,/TEX> and 0.8 m/s, respectively, Results reported in this parametric study may be useful to understand the unsteady behavior of the system.

  • PDF

Study on Standards of Combustion Stability Assessment of Liquid Rocket Engine Combustion Devices (액체로켓 엔진 연소장치의 연소 안정성 평가 기준에 대한 연구)

  • Seo, Seong-Hyeon;Lee, Kwang-Jin;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.6
    • /
    • pp.34-40
    • /
    • 2009
  • The present study describes the methods and standards for the combustion stability assessment of a thrust chamber and a gas generator as parts of a liquid rocket engine. The first method uses a statistical approach through typical static combustion tests and the second one a dynamic assessment identifying decaying characteristics of pressure fluctuations excited by a pulse generating device. Based on accumulated test results, it is concluded that the maximal values for combustion stability are 3% of a chamber static pressure with a Root-Mean-Square value of pressure fluctuations, and 10 msec with a decay time.

Static Chamber for Measurements Greenhouse Gas Emissions from Landfill Surface (Static Chamber를 이용한 도시쓰레기 매립지로부터의 온 실기체 배출량 측정)

  • 김득수;장영기;전의찬
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.277-279
    • /
    • 1999
  • 대기 중으로 배출되는 $CO_2$, CH$_4$, $N_2$O, $O_3$, CFC 등은 지구온난화에 기여하고, 이러한 온실기체들은 여러 경로를 통해서 대기로 배출되고 있다. 배출원별 온실기체의 기여도를 보면(Green peace, 1997) 화석연료 연소의 경우가 58%로 가장 높고, 농업과 토지이용의 변화에 의해 18%, 17%, 그리고 도시쓰레기의 매립에 의해서도 약 3%정도 기여하는 것으로 보고되었다. 주요 온실기체에 대한 대기 중 농도가 과거보다 현저하게 증가되었음이 확인되고 있고, $CO_2$의 경우 년간 증가율이 0.5%, CH$_4$의 경우는 1%, 그리고 $N_2$O의 경우는 약 0.2% 정도로 보고되고 있다.(Bouwman, 1990).(중략)

  • PDF

Investigation on the Turbulent Swirling Flow Field within the Combustion Chamber of a Gun-Type Gas Burner (Gun식 가스버너의 연소실내 난류 선회유동장 고찰)

  • Kim, Jang-Kweon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.9
    • /
    • pp.666-673
    • /
    • 2009
  • The turbulent swirling flow field characteristics of a gun-type gas burner with a combustion chamber were investigated under the cold flow condition. The velocities and turbulent quantities were measured by hot-wire anemometer system with an X-type probe. The turbulent swirling flow field in the edge of a jet seems to cause a recirculation flow from downstream to upstream due to the unbalance of static pressure between a main jet flow and a chamber wall. Moreover, because the recirculation flow seems to expand the main jet flow to the radial and to shorten it to the axial, the turbulent swirling flow field with a chamber increases a radial momentum but decreases an axial as compared with the case without a chamber from the range of about X/R=1.5. As a result, these phenomena can be seen through all mean velocities, turbulent kinetic energy and turbulent shear stresses. All physical quantities obtained around the slits, however, show the similar magnitude and profiles as the case without a chamber within the range of about X/R=1.0.

Design of a piezovibrocone and calibration chamber

  • Samui, Pijush;Sitharam, T.G.
    • Geomechanics and Engineering
    • /
    • v.2 no.3
    • /
    • pp.177-190
    • /
    • 2010
  • This paper presents the details of indigenous development of the piezovibrocone and calibration chamber. The developed cone has a cylindrical friction sleeve of $150cm^2$ surface area, capped with a $60^{\circ}$ apex angle conical tip of $15cm^2$ cross sectional area. It has a hydraulic shaker, coupled to the cone penetrometer with a linear displacement unit. The hydraulic shaker can produce cyclic load in different types of wave forms (sine, Hover sine, triangular, rectangular and external wave) at a range of frequency 1-10 Hz with maximum amplitude of 10 cm. The piezovibrocone can be driven at the standard rate of 2 cm/sec using a loading unit of 10 ton capacity. The calibration chamber is of size $2m{\times}2m{\times}2m$. The sides of the chamber and the top as well as the bottom portions are rigid. It has a provision to apply confining pressure (to a maximum value of $4kg/cm^2$) through the flexible rubber membrane inlined with the side walls of the calibration chamber. The preliminary static as well as dynamic cone penetration tests have been done sand in the calibration chamber. From the experimental results, an attempt has been made to classify the soil based on friction ratio ($f_R$) and the cone tip resistance ($q_c$).