• Title/Summary/Keyword: static VAR compensator

Search Result 132, Processing Time 0.029 seconds

GA based Selection Method of Weighting Matrices in LQ Controller for SVC (GA를 이용한 SVC용 LQ 제어기의 가중행렬 선정 기법)

  • 허동렬;이정필;주석민;정형환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.40-50
    • /
    • 2002
  • In this paper, we present a GA(Genetic Algorithm) approach to select weighting matrices of an optimal LQ(Linear Quadratic) controller for SVC(Static VAR Compensator). A SVC, one of the FACTS(Flexible AC Transmission System), constructed by a FC(Fixed Capacitor) and a TCR(Thyristor Controlled Reactor), was designed and implemented to improve the damping of a synchronous generator, as well as to control the system voltage Also, a design of LQ controller depends on choosing weighting matrices. The selection of weighting matrices which is not a trivial solution is usually carried out by trial and error. We proposed an efficient method using GA of finding weighting matrices for optimal control law. Thus, we proved the usefulness of proposed method to improve the stability of single machine-infinite bus with SVC system by eigenvalues analysis and simulation.

A Study on Enhancing the Total Transfer Capability from a Voltage Stability Point of View Using SVC (SVC 적용에 의한 전압 안정도 측면에서의 융통전력 향상 방안에 대한 연구)

  • Lee, B.H.;Lee, S.J.;Kim, J.H.;Jang, K.H.;Kim, Y.H.;Kwak, N.H.;Ju, J.H.;Lee, J.L.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.90-92
    • /
    • 2002
  • The SVC(Static Var Compensator) resulted from the FACTS technology can generate or absorb reactive power rapidly so as to increase the transient and voltage stability. In this paper, the SVC is applied to the power system in order to improve the total transfer capability from a viewpoint of static voltage stability and the effects of application of the SVC to the power system are analyzed. The IPLAN, which is a high level language used with PSS/E program, is employed for determining the total transfer capability.

  • PDF

Subtransmission Reduction for FAGTS Site Selection in Large Power System (대규모 전력계통에서의 하위 송전계통 축약을 이용한 FACTS 위치선정 연구)

  • Chang, Byung-Hoon;Choo, Jin-Boo;Kwon, Sea-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1302-1304
    • /
    • 1999
  • This Paper Proposes the FACTS site selection method using subtransmission system reduction. A general method which uses the sensitivity of the variation in voltage and reactive Power has been used to determine the location of shunt type FACTS device, but there is a difficulty to find a proper location due to the overestimation of the effect of sub-transmission systems. Therefore, there is a need to reduce sub-transmission system for finding an effective location of shunt type FACTS devices such as SVC(Static Var Compensator), STATCOM(Static Synchronous Compesator), and so on.

  • PDF

FACTS Site Selections in Large Power Systems using Subtransmission System Reduction (대규모 전려계통에서의 하위 송전계통 축약을 이용한 FACTS 위치선정 연구)

  • Jang, Byeong-Hun;Chu, Jin-Bu;Gwon, Se-Hyeok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.11
    • /
    • pp.1429-1433
    • /
    • 1999
  • This paper proposes the FACTS site selection method using subtransmission system reduction. A general method which uses the sensitivity of the variation in voltage and reactive power has been used to determine the location of shunt type FACTS device, but there is a difficulty to finding a proper location due to the overestimation of the effect of sub-transmission systems. Therefore, there is a need to reduce sub-transmission system for finding an effective location of shunt type FACTS devices such as SVC(Static Var Compensator), STATCOM(Static Synchronous Compesator), and so on.

  • PDF

Electric Arc Furnace Voltage Flicker Mitigation by Applying a Predictive Method with Closed Loop Control of the TCR/FC Compensator

  • Kiyoumarsi, Arash;Ataei, Mohhamad;Hooshmand, Rahmat-Allah;Kolagar, Arash Dehestani
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.116-128
    • /
    • 2010
  • Modeling of the three phase electric arc furnace and its voltage flicker mitigation are the purposes of this paper. For modeling of the electric arc furnace, at first, the arc is modeled by using current-voltage characteristic of a real arc. Then, the arc random characteristic has been taken into account by modulating the ac voltage via a band limited white noise. The electric arc furnace compensation with static VAr compensator, Thyristor Controlled Reactor combined with a Fixed Capacitor bank (TCR/FC), is discussed for closed loop control of the compensator. Instantaneous flicker sensation curves, before and after accomplishing compensation, are measured based on IEC standard. A new method for controlling TCR/FC compensator is proposed. This method is based on applying a predictive approach with closed loop control of the TCR/FC. In this method, by using the previous samples of the load reactive power, the future values of the load reactive power are predicted in order to consider the time delay in the compensator control. Also, in closed loop control, two different approaches are considered. The former is based on voltage regulation at the point of common coupling (PCC) and the later is based on enhancement of power factor at PCC. Finally, in order to show the effectiveness of the proposed methodology, the simulation results are provided.

Available Transfer Capability Enhancement with FACTS Devices in the Deregulated Electricity Market

  • Manikandan, B.V.;Raja, S. Charles;Venkatesh, P.
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.14-24
    • /
    • 2011
  • In order to facilitate the electricity market operation and trade in the restructured environment, ample transmission capability should be provided to satisfy the demand of increasing power transactions. The conflict of this requirement and the restrictions on the transmission expansion in the restructured electricity market has motivated the development of methodologies to enhance the available transfer capability (ATC) of existing transmission grids. The insertion of flexible AC transmission System (FACTS) devices in electrical systems seems to be a promising strategy to enhance single area ATC and multi-area ATC. In this paper, the viability and technical merits of boosting single area ATC and multi-area ATC using Thyristor controlled series compensator (TCSC), static VAR compensator (SVC) and unified power flow controller (UPFC) in single device and multi-type three similar and different device combinations are analyzed. Particle swarm optimization (PSO) algorithm is employed to obtain the optimal settings of FACTS devices. The installation cost is also calculated. The study has been carried out on IEEE 30 bus and IEEE 118 bus systems for the selected bilateral, multilateral and area wise transactions.

Reactive Power Compensator for Pulsed Power Electric Network of International Thermonuclear Experimental Reactor (국제 열핵융합실험로 펄스전원계통의 무효전력보상기 검증)

  • Jo, Hyunsik;Jo, Jongmin;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.290-295
    • /
    • 2015
  • Analysis and verification of reactive power compensator (RPC) for ITER pulsed power electric network (PPEN) are described in this paper. The RPC system is rated for a nominal power of 250 Mvar necessary to comply with the allowable reactive power limit value from the grid 200 Mvar. This system is currently under construction and is based on static var compensation technology with a thyristor-controlled reactor and a harmonic filter. The RPC minimizes reactive power from grid using prediction of reactive power consumption of AC-DC converters. The feasibility of the reactive power compensation was verified by assembling a real controller and implementing ITER PPEN in the real time digital simulator for the hardware-in-loop facility. When maximum reactive power is reached, grid voltage is stabilized and maximum reactive power decreased from 120 Mvar to 40 Mvar via the reactive power prediction method.

Transient Stability Enhancement of Power System by Using Energy Storage System (에너지저장시스템을 이용한 전력계통의 과도안정도 향상)

  • Seo, Gyu-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.26-31
    • /
    • 2017
  • The conventional method of improving the transient stability in a power system is the use of reactive power compensation devices, such as the STATCOM and SVC. However, this traditional method cannot prevent the rapid voltage collapse brought about by the stalling of the motor due to a system fault. On the other hand, the ESS (Energy Storage System) provides fast-acting, flexible reactive and active power control. The fast-acting power compensation provided by an energy storage system plays a significant role in enhancing the transient stability after a major fault in the power system. In this paper, a method of enhancing the transient stability using an energy storage system is proposed for power systems including a dynamic load, such as a large motor. The effectiveness of the energy storage system compared to conventional devices in enhancing the transient stability of the power system is presented. The results of the simulations show that the simultaneous injection of active and reactive power can enhance the transient stability more effectively.

Transient Stability Enhancement of Power System by Using Energy Storage System (풍력터빈 발전기가 연계된 전력계통에서 에너지저장시스템이 과도안정도에 미치는 영향)

  • Seo, Gyu-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.592-597
    • /
    • 2019
  • A conventional method to improve transient stability in power system is the use of reactive power compensation devices such as STATCOM and SVC. However, this traditional method cannot prevent a rapid voltage collapse brought on by motors stalling due to system fault. On the other hand, ESS(Energy Storage System) provides fast-acting, flexible reactive and active power control. The fast active power compensation with energy storage system plays a significant role in transient stability enhancement after a major fault of power system. In this paper, transient stability enhancement method by using energy storage system is proposed for the power system including a dynamic load such as large motor. The effectiveness of energy storage system compared to conventional devices in enhancing transient stability of power system is presented. The results of simulations show that the simultaneous injection of active and reactive power can enhance more effectively transient stability.

A Study on Unbalance Compensation Using SVC in Electric Railway Feeding System (전기철도 급전시스템에서 SVC를 이용한 전압불평형 보상에 관한 연구)

  • Son, Guk-Hyun;Choi, Kyu-Hyoung;Kim, Sung-Il;Jung, Ho-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3124-3132
    • /
    • 2011
  • Scott transformers have widely used to convert three phases into two phases and compensate the unbalance. Theoretically, the loads of the two secondary phases are same, no unbalance appears in the PCC(point of common coupling). But Due to the uncertainty of traction load, the unbalance are generally presented at the PCC. In this paper The amount of the voltage unbalance is expressed in the ratio of the negative sequence voltages to the positive sequence voltage. We tried to compensate the unbalance using SVC(Static Var Compensator)in an unbalance traction loads state by modeling. The SVC are installed and controlled to provide different amounts of reactive power compensation.

  • PDF