• Title/Summary/Keyword: statement analysis

Search Result 597, Processing Time 0.029 seconds

On the Epistemology of the National Informatization Policy - A Critical Review of the $5^{th}$ National Informatization Policy Plan (2013-2017) - (국가정보화 정책 인식구조에 대한 고찰 - 박근혜 정부 제 5차 국가정보화 기본계획 (2013-2017) 중심으로 -)

  • Juhn, Sung Hyun
    • Journal of Information Technology and Architecture
    • /
    • v.11 no.4
    • /
    • pp.393-407
    • /
    • 2014
  • The Government Informatization Policy Plan represents the government's technology policy vision and a set of ICT policy agenda and initiatives for the tenure of the government. The Policy Plan, however, normally produces an excess of disconcerted and superfluous ICT policy proposals from various policy units in the government. To cope with the superficiality of the ICT policy set in the Policy Plan, this paper proposes an analysis of the epistemology of the policy set. A policy is constructed as an argument and the structure of the policy argument is analysed using a model of argumentation. The findings show that the present informatization policy is driven by three epistemological motives - the production, consumption, and performance of the ICT Technology. The various assumptions and premises that underlie and direct the generation of ICT policy arguments with different motives are idenfied and then are exposed to strong rebuttal arguments to evaluate their epistemological tenability. The policy implications of the epistemological analysis are discussed in the end.

The Influences of Perceived Locus of Control to Patients with Pain (지각된 통제소재 (Locus of Control)가 통증환자의 심리상태에 미치는 영향)

  • Cho, Sun-Mi;Chin, Bum-Su;Song, Ho-Jeong;Kim, Chan;Han, Gyung-Lim
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.10 no.2
    • /
    • pp.101-109
    • /
    • 2002
  • Objectives: Cognitive-behavioral scientists have long been interested in how a pain patient's cognition such as locus of control relates to coping and adjustment. The present study examined the relationship of locus of control orientation to pain coping strategies, psychological distress and perceived pain intensity of patients with pain. Methods : Subjects were 96 patients with pain who visited pain clinic. All patients were administered the Multidimensional Health Locus of Control Scales, the Minnesota Multiphasic Personality Inventory, the Coping Strategies Questionnaire, and rating for perceived pain intensity, distress, and duration. Results : Correlational analysis revealed that patients who viewed outcomes as controlled by internality tended to have better ability to control and decrease pain. Also they tended to be less depressed and anxious. Regression analysis indicated that patients having a internal locus of control were more likely to use coping self-statement and reinterpreting pain sensation. Powerful others and chance locus of control orientation were predicted reliance on catastrophizing. Conclusion : The clinical implication of the present study is that cognitive factors of patients with pain such as locus of control influence emotional distress and coping. this study show that these factors should be applied to cognitive behavioral therapeutic intervention.

  • PDF

An Analysis of Cost Reduction Potentials for Modular Housing from the Long-term Perspective (장기적 관점에서의 모듈러 주택 공사비 절감기회 분석)

  • Kim, Hu Yong;Ryu, Kuk Mu;Kim, Kyoon Tai;Jun, Young Hun;Kim, Yea Sang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.6
    • /
    • pp.124-134
    • /
    • 2018
  • Despite the many advantages of modular housing, low preference for modular housing for consumers who are familiar with RC structure leads to high construction cost of modular housing. The cost of modular buildings is about 130% of that of RC structures, so it is urgent to secure economical efficiency of modular buildings. Therefore, in this study, after calculating the savings amount of modular housing by type of construction work, economic analysis was conducted from a long - term perspective. In order to carry out the research, the authors compiled and analyzed the material cost, labor cost, and expenses incurred by each type of work by reclassifying the statement of the modular housing into the factory production and the site installation. After that, Pareto diagrams were created to find a core work that is included in the cost ratio of about 80%, and selected it as a cost reduction subject. Based on the assumption that the market size of domestic modular housing is similar to the level of modular advanced countries such as Japan and European countries, six cost reduction methods were set up that reflects the characteristics of the modular construction method and used for the expert interviews. Cost saving potentials in percentage from the interview were converted to the amount of savings that can be achieved by each type of method when applying the method. Finally, the findings of the study are expected to suggest long-term directions for technical development for modular construction and cost savings.

COMPARISON OF RIGIDITY AND CASTABILITY IN DIFFERENT DESIGNS OF MAXILLARY MAJOR TITANIUM FRAMEWORK (타이타늄 상악 주연결장치에 디자인에 따른 주조성 및 견고성 비교)

  • Lee, Young-Jae;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.431-443
    • /
    • 2007
  • Statement of problem: Injuries along with discomfort may result on the oral mucosa when non-rigid material is used as the major connector in construction of RPD, since nonrigid major connectors transmit unstable forces throughout the appliance. Titanium which recently draws attention as a substitute of Co-Cr had a difficulty in fabricating due to high melting temperature but the development of casting technique makes it possible to apply to the clinical case. Purpose: The purpose of this study was to investigate the rigidity and the castability of titanium upper major connector by design and make a comparison with Co-Cr major connectors which are widely used in clinical cases now. Material and methods: Casting was done using CP-Ti(Grage 2) (Kobe still Co., Japan) for the experimental groups, and 4 various designs namely palatal strap, U-shaped bar, A-P strap, and complete palatal plate were casted and 5 of each designs were included in each group. For the experimental group, Universal testing machine (Model 4502; Instron, Canton, Mass) was used to apply vertical torsional force vertically to the horizontal plane of major connector. In the second experiment, Vertical compressive force was applied to the horizontal plane of major connector. As a comparative group, Co-Cr major connector was equally manufactured and underwent the same experimental procedures Strain rate was measured after constant loading for one minute duration, and statistical analysis was done with SPSS ver.10.0 for WIN(SPSS. Inc. USA). From the one-way ANOVA and variance analysis (P=0.05), Scheffe's multiple comparison test implemented. Results: 1. Least amount of strain was observed with complete palatal plate followed by A-P bar, palatal bar, and the U-shaped bar having most amount of strain. 2. In all designs of titanium major connector, less strain rate was observed under compressive loading than under torsional loading showing more resistance to lateral force. 3. For titanium major connector, less strain rate was observed when the force is applied to the first premolar area rather than to the second molar area indicating more strength with shorter length of lever. 4. In Comparison of Co-Cr major connector with titanium major connector, palatal strap and U-shaped bar designs showed higher strength under torsional force that is statically significant, and under compressive force, no significant difference was observed expert for U-shaped bar. 5. In titanium major connector, complete palatal plate showed lowest success rate in casting when compared with the Co-Cr major connector. Conclusion: Above results prove that when using titanium for major connector, only with designs capable of generating rigidity can the major connector have almost equal amount of rigidity as Co-Cr major connector and show lower success rate in casting when compared with the Co-Cr major connector.

The Shear Bond Strength of Resin to Electroforming Gold according to the Surface Treatment (표면처리방법에 따른 Electroforming Gold와 레진과의 전단결합강도)

  • You, Byung-Il;Chang, Mun-Suk;Yoon, Tae-Ho;Park, Ju-Mi;Park, Charn-Woon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.2
    • /
    • pp.125-136
    • /
    • 2006
  • Statement of problem. The success of the bonding between electroforming gold and resin is dependent on the surface-conditioning technique but its effective technique has net been studied widely. Purpose. The purpose of the study was to evaluate the bond strength between the electroforming gold and resin with varying the surface-conditioning technique. Materials and methods. Sixty rectangular shaped metal specimens were made and one side of each specimen were gold hard plated. The sand-blasted specimens were divided into four experimental groups with fifteen specimens in each group and were treated as follows. Group 1: Silicoating (Rocatec, 3M ESPE)+ Sinfony (3M ESPE), Group 2: SR Link+ SR Adoro (Ivoclar Vivadent), Group 3: Tin plating (Microtin, Danville Engineering)+ SR Link+ SR Adoro, Group 4: Tin plating (Micro tin, Danville Engineering)+ Silicoating (Rocatec)+ Sinfony. Shear bond strength at metal-resin interface were measured using universal testing machine. Energy Dispersive x-ray analysis was done and scanning electron microscope images were taken and observed. Results and Conclusion. The following conclusions were drawn. 1. The mean shear bond strength values in order were 11.69MPa (Group 2), 22.35MPa (Group 3), 22.40MPa (Group 1) and 27.71MPa (Group 4). There was no significant difference in Group 1, Group 3 and Group 4(P>0.05). 2. In the EDX line analysis, the Au was detected on the surface of all specimen. $SnO_2$ showed on the surface of Group 2 and $SiO_2$ was detected on the surface of Group 1. 3. Increasing of roughness by sandblasting(Group 2), formation of micro-irregularities and tin crystals by electrolytic tin plating(Group 3) and formation of surface irregularities and $SiO_2$ layer(Group 1,4) were observed in SEM photo. 4. Tin plating(Group 3) and Rocatec treatment(Group 1) showed clinically effective shear bond strength(>20MPa), but when the two surface conditioning method were used together higher bond strength were achieved.

The Role of Deductive Reasoning in Scientific Activities (과학활동에서 연역적 사고의 역할)

  • Park, Jong-Won
    • Journal of The Korean Association For Science Education
    • /
    • v.18 no.1
    • /
    • pp.1-17
    • /
    • 1998
  • What does mean the statement that scientific reasoning is logical? In this study, we clarify the logical structure of the scientific explanation, prediction and the process of hypothesis testing. To simplify and identify the structure of scientific explanations and prediction more clearly, we used syllogism and presented various concrete examples. Especially, we showed that the logical structure of scientific explanation was well reflected in dynamics. Based on this analysis, it can be said that the deficit of students' understanding of dynamics is because that many scientific activities are focused on prediction rather than explanation. To explain the process of hypothesis testing, we reinterpreted the Wason's selection task as two stages: the process of prediction of experimental phenomena based on the presented hypothesis, and the process of the hypothesis testing based on the predicted experimental phenomena. And we suggested the reason of the logical fallacy of 'affirming the consequent' in science was because that many scientific relationships between the variables is one-to-one relationship, and compared this suggestion with the Lawon's multiple hypothesis theory. To check out the effect of content on the deductive reasoning, we reviewed some researches about psychology and psychology of science. And to understand the role of deductive reasoning in student's scientific activities, we reviewed researches about the analysis of students' responses in the task of conceptual change or evaluation of evidence and so on.

  • PDF

FINITE ELEMENT ANALYSIS ON MAXILLARY MOLAR IMPLANT UNDER DIFFERENT C/R RATIO (상악 구치부 임플랜트 보철수복시 치관/치근비에 따른 응력 분포에 대한 유한 요소 분석)

  • Kim, Jin-Ho;Kim, Hyung-Seob;Choi, Dae-Gyun;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.561-573
    • /
    • 2006
  • Statement of the problem: In cases of low bone level in maxilla followed by extraction due to severe periodontitis or enlarged maxillary sinus, crown-root ratio of implant prosthesis will increase. The prognosis of these cases is not good as expected. Purpose : The purpose is to compare stress distribution due to crown-root ratio and effect of splinting between two implants in maxillary molar area under different loads Material and methods: Using ITI($4.1{\times}10$ mm) implant. two finite element models were made(model S: two parallel implants, model A: one of two is 20 degree inclined). Each model was designed in different crown-root ratio(0.7:1, 1:1, 1.25:1) and set cement type gold crown to make it splinted or non-splinted clinical situations. After that, 300 N force was loaded to each model in four ways.(load 1 : middle of occlusal table, load 2 : middle of buccal cusp, load 3 : middle of lingual cusp, load 4 : horizontal load to middle of buccal cusp), and stress distribution was analyzed. Results: On all occasions, stress was concentrated on neck of implant near cortical bone. In the case of inclined implant, stress was increased compared with parallel implants. Under load 1, 2, 3, stress was not increased even when crown-root ratio increases, but under load 4, when crown-root ratio increases, stress also increased. And more stress was concentrated under load 1 than load 2, 3. When crown-root ratio was same, stress under load 1, 2, 3 decreased when splinting, but under load 4, stress did not really decrease. Conclusion: Under vertical load, stress distribution related to crown-root ratio did not change. But under horizontal load, stress increased as crown-root ratio increases. Under vertical load, splinting decreased stress but under horizontal load, effect of splinting was decreased as condition of implant changes for the worse such as increase of crown-root ratio, inclined implant.

Integration of Geographic Information System and Air Dispersion Model (지리정보체계와 대기확산의 통합)

  • Kim, Myung-Jin;Han, Eui-Jung;Kang, In-Goo;Kim, Jeong-Soo
    • Journal of Environmental Impact Assessment
    • /
    • v.5 no.1
    • /
    • pp.61-67
    • /
    • 1996
  • Environmental Impact Assessment (EIA) in Korea has worked toward environmental conservation and decision making since the Environmental Impact Statement of 1981. In order to implement the EIA process effectively, we have developed a system for and various methods of EIA. Among these methods, the Geographic Information System (GIS), which was introduced recently in Korea, can be used to integrate geographic and attribute data effectively. So GIS begins to increase the necessity of the application in EIA process. This study includes the integration method of the GIS and air dispersion model on the odor impact assessment of $NH_3$ emission in landfill sites. First, it computes surface values by grids using the Digital Elevation Model (DEM). Second, it presents predicted data considering topography and climate by grids. Third, it shows the overlaying analysis of the administrative map including population and odor predictive data. The results could systematically analyze impact areas, and assess residential impact by alternatives. Integration analysis of the air predictive model and GIS as a residential area assessment can support negotiations of public and proponent in EIA.

  • PDF

Technical Value Model and Evaluation for Smart In-vehicle Network (스마트 차량내(內) 네트워크 기술가치 모델 및 평가)

  • Kim, Byung-Woon
    • Journal of Korea Technology Innovation Society
    • /
    • v.20 no.2
    • /
    • pp.368-386
    • /
    • 2017
  • The purpose of this study is to present the technology value model based on profit approach and IITP practical guide for Ethernet network technology, which is the core technology of autonomous vehicles and connected cars in the hyper-connected industry. In-vehicle network, Ethernet technology, Ethernet port count, port pricing, and application data for technology assessment are sources of global market research organizations. The data on the company's COGS (Cost of Goods Sold), operating capital requirement, capital expenditure, and income statement data are used by the Bank of Korea's Business Analysis Report. According to the results of the study, the product market size was estimated to be US $470.3 billion and the technology market size was $52.1 billion over the seven years of economic life cycle of technology. The market value of the technology was estimated to be $260 million reflecting the possibility of entry into the market. In the case of the corporate management analysis report, the average value of the IITP and the top 25% were $0.7 million and $40.2 million, respectively. -27.8 million, and -73.6 million dollars respectively. This implies that government support for policy support is needed when conducting corporate R&D with high cost-to-sales ratio. The results of this study can be used as a reference for the evaluation of technology demand based ICT R&D technology in the industrial internet market in the fourth industrial revolution era.

THE EFFECT OF AUTOCLAVE STERILIZATION AND REUSE OF $SMARTPEG^{TM}$ ON THE IMPLANT STABILITY QUOTIENT (ISQ) MEASUREMENT ($Smartpeg^{TM}$의 고압멸균소독 및 재사용이 임플랜트 안정성 지수(ISQ) 측정에 미치는 영향)

  • Kang, In-Ho;Kim, Myung-Joo;Lim, Young-Jun;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.644-652
    • /
    • 2007
  • Statement of problem: Resonance frequency analysis is evaluated as the non-invasive and objective method for the evaluation of implant stability and has been increasingly used. It is necessary to evaluate the factors affect the ISQ measurement stability. Purpose: This study was performed to evaluate the effect of the autoclave sterilization and reuse of $Smartpeg^{TM}$ on ISQ measurement. Material and methods: $SmartPeg^{TM}$ (Integration Diagnostics Ltd., $G\ddot{o}teborg$, Sweden) of autoclave group (A) was autoclave sterilized 9 times and $Smartpeg^{TM}$ of reuse group (R) was reused 9 times. Ten $SmartPeg^{TM}s$ were allocated to each group and after each autoclave sterilization and reuse, implant stability quotient (ISQ) values were measured 3 times from the two directions a and b at a right angle. $Osstell^{TM}$ mentor (Integration Diagnostics Ltd. $G\ddot{o}teborg$, Sweden) was used and type 1 (article no. 100353) $Smartpeg^{TM}$ was selected according to $Smartpeg^{TM}$ reference list. Osstem Implant US II future (Osstem Co., Seoul, Korea) in $4.0mm{\times}11.5mm$ was embedded in the self-curing acrylic resin ($Orthojet^{(R)}$, Lang Dental, U.S.A.). Data was statistically analyzed by one-way ANOVA $({\alpha}=.05)$ and scheffe test was done where a significant difference exist. Correlation test was also done between ISQ value and the number of autoclave sterilization or reuse. Results: 1. In autoclave group, the means and sd. of ISQ value before autoclave sterilization were $84.97{\pm}0.41,\;84.93{\pm}0.74$ at direction a and b. There was significant differences between autoclave groups at direction a and b (P=.000). 2. In reuse group, the means and sd. of ISQ value before reuse were $85.40{\pm}0.62,\;85.50{\pm}0.57$ at direction a and b. There was no significant difference between reuse groups at direction a and b (P>.05). 3. There was a weak positive correlation between the number of reuse and ISQ value at direction a and b (${\gamma}=.207$ and .246, P<.01). Conclusion: Within the limitations of this study, the following conclusions were drawn. Till ninth reuse of $Smartpeg^{TM}$, the ISQ measurement stability did not be affected. After twice autoclave sterilization of $Smartpeg^{TM}$ the ISQ measurement stability was affected.