• Title/Summary/Keyword: statement analysis

Search Result 599, Processing Time 0.023 seconds

COMPARATIVE STUDY OF FRACTURE STRENGTH DEFENDING ON THE THICKNESS OF SOME ALL CERAMIC CORES (수종의 전부도재관 코어의 두께에 따른 파절강도의 비교 연구)

  • Kim Doo-Yong;Lee Young-Soo;Park Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.49-57
    • /
    • 2004
  • Statement of problem : The increased awareness of esthetics in dentistry has brought the esthetic consideration in prosthetic restorations . Dental ceramics offer better esthetics for use of prosthetic restorations. Unfortunately, dental ceramic materials are not always the most suitable candidate materials since their inherently brittle nature. In recent years, basic research in ceramic science has led to the recognition or several approaches to strengthen and to enhance esthetics of ceramics. Several all ceramic systems use ceramic core and porcelain build up structures . Ceramic cores influence to strength of all ceramic crowns . So the strength of ceramic cores is important to all ceramic crowns. Purpose : The purpose of this study is to estimate the flexural strength of ceramic cores in some all ceramic systems. Material and method : A biaxial flexure test was conducted on three groups(Cergo, Empress 2, In-Ceram). Each group consisted of 30 discs of nearly identical dimension with a 0.5mm, 1.0mm, 1.5mm thickness and 12mm in diameter. The fracture load was recorded by Instron. Analysis of valiance(ANOVA) and Tukey's tests were performed using SAS statistical software. Results : 1.5mm thickness of specimens were significantly stronger than 0.5mm and 1.0mm thickness of specimens in Cergo and In-Ceram. But each sepecimen group of Empress 2 was no significantly strength by thickness. In order of In-Ceram, Empress 2 and Cergo has significantly stronger strength in the same thickness. Conclusion : In-Ceram is the strongest ceramic material in 3 materials. All the materials can be used according to the required characters.

A NOVEL 3D SCAN METHOD TO QUANTIFY TEETH WEAR (3-Dimensional scan을 이용한 치아 마모량 측정 방법에 관한 연구)

  • Kim Seung-June;Choi Dae-Gyun;Kwon Kung-Rock;Lee Seok-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Statement of problem : Tooth wear is physiological phenomenon. Ninety-seven percent of normal people have tooth wear and about 7% has pathologic teeth wear. If we know the amount of tooth surface loss caused by pathologic tooth wear, we may restore it ideally Purpose : Recently measurement of tooth wear by using 3D scan has been increasing. Therefore, we need to know how accurate 3D scan is. Past accuracy test on 3D scan was about linear change, but as we know that tooth wear is volume change. Thus, the purpose of this study is to know how accurate 3D scan is. Material and Methods : For accuracy test of 3D scanner volume values measured by 3D scanner and micro-balance were compared. For test I, preliminary, 3 ball samples and 3 circular cones were made with pattern resin. For test II, 10 teeth shape rubber samples were used. Results and Conclusion : 1. The result of the accuracy test on 3D scan with 3 ball samples and 3 circular cones made of pattern resin has no significant difference(p<0.05). 2. The result of the accuracy test on 3D scan with 10 samples of tooth shape rubber has no significant difference (p<0.05). As a result, we may concluded the analysis of quantifying tooth wear used by 3D scan is useful in the clinic.

EVALUATION AND DEVELOPMENT OF DIGITAL DEVICE FOR MEASURING PROXIMAL TOOTH CONTACT TIGHTNESS (디지털 방식의 인접면 접촉강도 측정장치의 개발 및 평가)

  • Choi, Woo-Jin;Kim, Kyung-Hwa;Kim, Jin-A;Kang, Dong-Wan;Oh, Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.687-695
    • /
    • 2007
  • Statement of problem: The proper contact relation between adjacent teeth in each arch plays an important role in the stability and maintenance of the integrity of the dental arches. Proximal contact has been defined as the area of a tooth that is in close association, connection, or touch with an adjacent tooth in the same arch. Purpose: The aim of this study was to develop a digital device for measuring the proximal tooth contact tightness by pulling a thin stainless steel strip (2mm wide, 0.03mm thick) inserted between proximal tooth contact. Material and method: This device consists of measuring part, sensor part, motor part and body part. The stainless steel strip was connected to a stain gauge. The strain gauge was designed to convert the frictional force into a compressive force. This compressive force was detected as a electrical signal and the electrical signal was digitalized by a A/D converter. The digital signals were displayed by a micro-processor. The pulling speed was 8mm/s. Results: For testing reliability of the device in vivo, two healthy young adults (A, B) participated in this experiment. The tightness of proximal tooth contact between the second premolar and the first molar of mandible (subject A) and maxilla (subject B) was measured fifteen times for three days at rest. We double-checked the accuracy of the device with a Universal Testing Machine. Output signals from the Universal Testing Machine and the measuring device were compared. Regression analysis showed high linearity between these two signals. In vivo test, no significant differences were found between measurements. Conclusion: This device has shown to he capable of producing reliable and reproducible results in measuring proximal tooth contact. Therefore, it was considered that this device was appropriate to apply clinically.

3D FINITE ELEMENT ANALYSIS OF OVERDENTURE STABILITY AND STRESS DISTRIBUTION ON MANDIBULAR IMPLANT-RETAINED OVERDENTURE (하악 임플랜트 유지형 피개의치의 안정성과 하악골 응력분포에 대한 3차원 유한요소법적 연구)

  • Hong, Hae-Ryong;Choi, Dae-Gyun;Bak, Jin;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.633-643
    • /
    • 2007
  • Statement of problem: Recently there are on an increasing trend of using implants-especially in edentulous mandible of severly alveolar bone recessed. Purpose: The aim of this study was to analyze the displacement and stress distribution of various mandibular implant-retained overdenture models supported by two implants in interforaminal region under the occlusion scheme load. Material and method: FEA models were made by the 3D scanning of the edentulous mandibular dentiform. The three models were named as Model M1, M2, and M3 accord ing to the position of implants: M1, Lt. incisor area, M2, Canine area, and M3, 1st Premolar area. Inter-implant angulation model was named as M4. Conventional complete denture was named M5 and used as a control group. Ball implant and Gold matrice were used as a retentive anchors. The occlusion type loads were applied horizontally over each tooth. Results: 1. In mandibular implant retained overdenture Canine Protected Occlusion type load resulted in higher levels of stress to the implants and female matrices than other types of loads. 2. The overdenture model M1, with implants in lateral incisor areas resulted in lower stress concentration to the implants and female matrices than other models. 3. In mandibular implant retained overdenture the stresses of the implant and female matrice were lower in mesially inclined implant than these of parallel installed implant. Conclusion: Lateral incisor areas could be the best site for the implants in mandibular implant-retained overdenture. The mandibular implant retained overdenture models mentioned above showed to the lowest stress to the implants and female matrices.

Cost-Benefit Analysis of E-Government: Australia

  • Yoon, Joseph;Moon, Yong-Eun
    • Journal of Digital Convergence
    • /
    • v.3 no.2
    • /
    • pp.73-116
    • /
    • 2005
  • When people contact the government they can use a variety of channels. That is, they go in person to an office, use a telephone service, access information via the Internet, send a letter, or use a third party. Since the Australian Government first recognised the potential of online technology to improve service delivery in its 1997 Investing for Growth statement, it has articulated its policies and strategies for e-government in a number of papers. E-government involves government agencies delivering better programs and services online through the use of new information and communication technologies. The policy papers included Government Online-The Commonwealth's Strategy, launched in April 2000, and a new framework for e-government, Better Services. Better Government, launched in November 2002. Most recently, the Government released Australia's Strategic Framework for the Information Economy in July 2004. These papers outlined the broad directions and priorities for the future of e-government in Australia, and sought to maintain the momentum of agencies' actions under Government Online. One of its key objectives was for agencies to achieve greater efficiency in providing services and a return on their investments in ICT (Information and Communication Technology)-based service delivery. They also stated that investing in e-government should deliver tangible returns, whether they take the form of cost reductions, increased efficiency and productivity, or improved services to business and the broader community Implementation of the Government policy has led to considerable agency investment in ICT-based service delivery. However government policy also requires managers to ensure that program and service delivery is efficient and effective. Efficient and effective use of ICT has the potential to improve service delivery and to make financial savings. This paper outlines how people are using the channels to contact the government in Australia. It also examines the level of satisfaction they have with those services and their preferences and expectations. In addition, this paper aims at identifying the methods used by Australian Government to measure the efficiency and effectiveness of their delivery of services, and at assessing the adequacy of these methods.

  • PDF

Construction of Global Finite State Machine from Message Sequence Charts for Testing Task Interactions (태스크 상호작용 테스팅을 위한 MSC 명세로부터의 전체 유한 상태 기계 생성)

  • Lee, Nam-Hee;Kim, Tai-Hyo;Cha, Sung-Deok;Shin, Seog-Jong;Hong, H-In-Pyo;Park, Ki-Wung
    • Journal of KIISE:Software and Applications
    • /
    • v.28 no.9
    • /
    • pp.634-648
    • /
    • 2001
  • Message Sequence Charts(MSC) has been used to describe the interactions of numerous concurrent tasks in telecommunication software. After the MSC specification is verified in requirement analysis phase, it can be used not only to synthesize state-based design models, but also to generate test sequences. Until now, the verification is accomplished by generating global state transition graph using the location information only. In this paper, we extend the condition statement of MSC to describe the activation condition of scenarios and the change of state variables, and propose an approach to construct global finite state machine (GFSM) using this information. The GFSM only includes feasible states and transitions of the system. We can generate the test sequences using the existing FSM-based test sequence generation technology.

  • PDF

Type of Coping with Stress of Nursing Students (간호학과 학생의 스트레스 대처 양상)

  • Kim, Yun-Jeong
    • Journal of the Korea Convergence Society
    • /
    • v.5 no.3
    • /
    • pp.29-39
    • /
    • 2014
  • This study designed to know subjective structure about type of coping with stress of nursing students using Q-methodology. The statement positions on the sorting continuum were scored from +4(representing the highest level of agreement) through 0(at the neutral position on the continuum) through -4(representing the highest level of disagreement). Factor analysis of the data was undertaken using PC QUANL software to determine if any patterns were discernible. The four types extracted eigenvalues greater than 1.0 and explained approximately 52.14% of the variation in responses(31.73, 10.13, 5.73 and 4.65% respectively).: (1) Positive resolve type, (2) Ignore problem type, (3) Self resolution type and (4) Conversation type. The study results can be utilized in both an effective nursing education and clinical practice.

Histologic evaluation and removal torque analysis of nano- and microtreated titanium implants in the dogs

  • Ahn, Seok;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.75-84
    • /
    • 2009
  • STATEMENT OF PROBLEM. A number of studies about the nano-treated surfaces of implants have been conducting along with micro-treated surfaces of implants. PURPOSE. The purpose of this study was to get information for the clinical use of nano-treated surfaces compared with micro-treated surfaces by measuring removal torque and analyzing histological characteristics after the placement of various surface-treated implants on femurs of dogs. MATERIAL AND METHODS. Machined surface implants were used as a control group. 4 nano-treated surface implants and 3 micro-treated surface implants [resorbable blast media surface (RBM), sandblast and acid-etched surface (SAE), anodized RBM surface] were used as experimental groups. Removal torque values of implants were measured respectively and the histological analyses were conducted on both 4weeks and 8weeks after implant surgery. The surfaces of removed implants after measuring removal torque values were observed by scanning electron microscopy (SEM) at 8 weeks. RESULTS. 1. Removal torque values of the nano-treated groups were lower than those of micro-treated groups. 2. Removal torque values were similar in the anodized RBM surface groups. 3. On the histological views, there was much of bone formation at 8 weeks, but there was no difference between 4 and 8 weeks, and between the types of implant surfaces as well. CONCLUSION. it is suggested that implant topography is more effective in removal torque test than surface chemistry. To get better clinical result, further studies should be fulfilled on the combined effect of surface topography and chemistry for the implant surface treatments.

Implant surface treatments affect gene expression of Runx2, osteogenic key marker

  • Na, Young;Heo, Seong-Joo;Kim, Seong-Kyun;Koak, Jai-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.91-96
    • /
    • 2009
  • STATEMENT OF PROBLEM. The aim of this study was to study the effects of various surface treatments to a titanium surface on the expression of Runx2 in vitro. MATERIAL AND METHODS. Human Osteosarcoma TE-85 cells were cultured on machined, sandblasted, or anodic oxidized cpTi discs. At various times of incubation, the cells were collected and then processed for the analysis of mRNA expression of Runx2 using reverse transcription-PCR. RESULTS. The expression pattern of Runx2 mRNA was differed according to the types of surface treatment. When the cells were cultured on the untreated control culture plates, the gene expression of Runx2 was not increased during the experiments. In the case of that the cells were cultured on the machined cpTI discs, the expression level was intermediate at the first day, but increased constitutively to day 5. In cells on sandblasted cpTi discs, the expression level was highest in the first day sample and the level was maintained to 5 days. In cells on anodized cpTi discs, the expression level increased rapidly to 3 days, but decreased slightly in the 5-th day sample. CONCLUSION. Different surface treatments may contribute to the regulation of osteoblast function by influencing the level of gene expression of key osteogenic factors.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF METAL-CERAMIC VERSUS COMPOSITE RESIN-VENEERED METAL CROWNS IN CEMENT-RETAINED IMPLANT-SUPPORTED CROWNS UNDER VERTICAL COMPRESSIVE LOAD

  • Pae, Ahran;Jeon, Kyung-A;Kim, Myung-Rae;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.295-302
    • /
    • 2007
  • Statement of problem. Fracture of the tooth-colored superstructure material is one of the main prosthetic complications in implant-supported prostheses. Purpose. The purpose of this in vitro study was to compare the fracture strength between the cement-retained implant-supported metal-ceramic crowns and the indirect composite resinveneered metal crowns under the vertical compressive load. Material and methods. Standard implants of external type (AVANA IFR 415 Pre-mount; Osstem Co., Busan, Korea) were embedded in stainless steel blocks perpendicular to their long axis. Customized abutments were fabricated using plastic UCLA abutments (Esthetic plastic cylinder; Osstem Co., Busan, Korea). Thirty standardized copings were cast with non-precious metal (Rexillium III, Pentron, Walling ford, Conn., USA). Copings were divided into two groups of 15 specimens each (n = 15). For Group I specimens, metal-ceramic crowns were fabricated. For Group II specimens, composite resin-veneered (Sinfony, 3M-ESPE, St. Paul, MN, USA) metal crowns (Sinfony-veneered crowns) were fabricated according to manufacturer's instructions. All crowns were temporary cemented and vertically loaded with an Instron universal testing machine (Instron 3366, Instron Corp., Norwood, MA, USA). The maximum load value (N) at the moment of complete failure was recorded and all data were statistically analyzed by independent sample t-test at the significance level of 0.05. The modes of failure were also investigated with visual analysis. Results. The fracture strength of Sinfony-veneered crowns ($2292.7{\pm}576.0N$) was significantly greater than that of metal-ceramic crowns ($1150.6{\pm}268.2N$) (P < 0.05). With regard to the failure mode, Sinfony-veneered crowns exhibited adhesive failure, while metal-ceramic crowns tended to fracture in a manner that resulted in combined failure. Conclusion. Sinfony-veneered crowns demonstrated a significantly higher fracture strength than that of metal-ceramic crowns in cement-retained implant-supported prostheses.