• Title/Summary/Keyword: state switching

Search Result 1,026, Processing Time 0.033 seconds

High Performance Flexible Inorganic Electronic Systems

  • Park, Gwi-Il;Lee, Geon-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.115-116
    • /
    • 2012
  • The demand for flexible electronic systems such as wearable computers, E-paper, and flexible displays has increased due to their advantages of excellent portability, conformal contact with curved surfaces, light weight, and human friendly interfaces over present rigid electronic systems. This seminar introduces three recent progresses that can extend the application of high performance flexible inorganic electronics. The first part of this seminar will introduce a RRAM with a one transistor-one memristor (1T-1M) arrays on flexible substrates. Flexible memory is an essential part of electronics for data processing, storage, and radio frequency (RF) communication and thus a key element to realize such flexible electronic systems. Although several emerging memory technologies, including resistive switching memory, have been proposed, the cell-to-cell interference issue has to be overcome for flexible and high performance nonvolatile memory applications. The cell-to-cell interference between neighbouring memory cells occurs due to leakage current paths through adjacent low resistance state cells and induces not only unnecessary power consumption but also a misreading problem, a fatal obstacle in memory operation. To fabricate a fully functional flexible memory and prevent these unwanted effects, we integrated high performance flexible single crystal silicon transistors with an amorphous titanium oxide (a-TiO2) based memristor to control the logic state of memory. The $8{\times}8$ NOR type 1T-1M RRAM demonstrated the first random access memory operation on flexible substrates by controlling each memory unit cell independently. The second part of the seminar will discuss the flexible GaN LED on LCP substrates for implantable biosensor. Inorganic III-V light emitting diodes (LEDs) have superior characteristics, such as long-term stability, high efficiency, and strong brightness compared to conventional incandescent lamps and OLED. However, due to the brittle property of bulk inorganic semiconductor materials, III-V LED limits its applications in the field of high performance flexible electronics. This seminar introduces the first flexible and implantable GaN LED on plastic substrates that is transferred from bulk GaN on Si substrates. The superb properties of the flexible GaN thin film in terms of its wide band gap and high efficiency enable the dramatic extension of not only consumer electronic applications but also the biosensing scale. The flexible white LEDs are demonstrated for the feasibility of using a white light source for future flexible BLU devices. Finally a water-resist and a biocompatible PTFE-coated flexible LED biosensor can detect PSA at a detection limit of 1 ng/mL. These results show that the nitride-based flexible LED can be used as the future flexible display technology and a type of implantable LED biosensor for a therapy tool. The final part of this seminar will introduce a highly efficient and printable BaTiO3 thin film nanogenerator on plastic substrates. Energy harvesting technologies converting external biomechanical energy sources (such as heart beat, blood flow, muscle stretching and animal movements) into electrical energy is recently a highly demanding issue in the materials science community. Herein, we describe procedure suitable for generating and printing a lead-free microstructured BaTiO3 thin film nanogenerator on plastic substrates to overcome limitations appeared in conventional flexible ferroelectric devices. Flexible BaTiO3 thin film nanogenerator was fabricated and the piezoelectric properties and mechanically stability of ferroelectric devices were characterized. From the results, we demonstrate the highly efficient and stable performance of BaTiO3 thin film nanogenerator.

  • PDF

Toxicokinetics of rifapentine in beagle dogs (Beagle dog에 있어서 rifapentine의 독성동태연구)

  • Shin, Ho-chul;Lee, Hye-suk;Cha, Shin-woo;Han, Sang-seop;Roh, Jung-ku;Kim, Jin-suk;Lee, Won-chang
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.4
    • /
    • pp.815-822
    • /
    • 1995
  • The toxicokinetics of rifapentine was studied after an oral administration to beagle dogs. High-performance liquid chromatography(HPLC) using column-switching technique was performed to determine the serum concentrations of rifapentine. The pharmacokinetic profiles of rifapentine were analysed using one-compartment open model. Following a single oral administration of 10mg/kg, pharmacokinetic parameters were determined as follows: maximum serum concentration($C_{max}$), $28.90{\mu}g/ml$; maximum concentration time($T_{max}$), 3.7hr; elimination half-life($t_{1/2}$, 4.7hr; area under the curve(AUC), $339.0{\mu}g{\cdot}hr/ml$; volume of disiribution/bioavailability (Vd/F), 0.21 l/kg; lag time, 24min; absorption rate constant($k_a$), $0.445hr^{-1}$; elimination rate constant($k_{el}$), $0.148hr^{-1}$. After 6 month multiple oral doses of 10mg/kg/day, parameters were as follows: $C_{max}$, $34.40{\mu}g/ml$; $T_{max}$, 2.6hr; $t_{1/2}$, 6.7hr; AUC, $391.3{\mu}g{\cdot}hr/ml$; Vd/F, 0.291/kg; $k_a$, $0.976hr^{-1}$; $k_{el}$, $0.104hr^{-1}$. The consistant kinetic parameters after a single and multiple oral administration show that there was no accumulation of rifapentine after 6 month oral administration. We also simulated the concentration of rifapentine after oral multiple administration of 10 and 50mg/kg/ day, based on the parameters obtained form the single administration. The measured serum concentrations of rifapentine were well fitted to the simulated results. The simulated results show that rifapentine readily reaches to steady-state after about 3 doses and the steady-state serum concentrations($C_{ss}$) are fluctuated in between $2.2{\sim}25.2{\mu}g/ml$, and $10.6{\sim}125.2{\mu}g/ml$ at the doses of 10 and 50mg/kg/day, respectively.

  • PDF

Structure and Control of Smart Transformer with Single-Phase Three-Level H-Bridge Cascade Converter for Railway Traction System (Three-Level H-Bridge 컨버터를 이용한 철도차량용 지능형 변압기의 구조 및 제어)

  • Kim, Sungmin;Lee, Seung-Hwan;Kim, Myung-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.5
    • /
    • pp.617-628
    • /
    • 2016
  • This paper proposes the structure of a smart transformer to improve the performance of the 60Hz main power transformer for rolling stock. The proposed smart transformer is a kind of solid state transformer that consists of semiconductor switching devices and high frequency transformers. This smart transformer would have smaller size than the conventional 60Hz main transformer for rolling stock, making it possible to operate AC electrified track efficiently by power factor control. The proposed structure employs a cascade H-Bridge converter to interface with the high voltage AC single phase grid as the rectifier part. Each H-Bridge converter in the rectifier part is connected by a Dual-Active-Bridge (DAB) converter to generate an isolated low voltage DC output source of the system. Because the AC voltage in the train system is a kind of medium voltage, the number of the modules would be several tens. To control the entire smart transformer, the inner DC voltage of the modules, the AC input current, and the output DC voltage must be controlled instantaneously. In this paper, a control algorithm to operate the proposed structure is suggested and confirmed through computer simulation.

Design of X-Band High Efficiency 60 W SSPA Module with Pulse Width Variation (펄스 폭 가변을 이용한 X-대역 고효율 60 W 전력 증폭 모듈 설계)

  • Kim, Min-Soo;Koo, Ryung-Seo;Rhee, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1079-1086
    • /
    • 2012
  • In this paper, X-band 60 W Solid-State Power Amplifier with sequential control circuit and pulse width variation circuit for improve bias of SSPA module was designed. The sequential control circuit operate in regular sequence drain bias switching of GaAs FET. The distortion and efficiency of output signals due to SSPA nonlinear degradation is increased by making operate in regular sequence the drain bias wider than that of RF input signals pulse width if only input signal using pulsed width variation. The GaAs FETs are used for the 60 W SSPA module which is consists of 3-stage modules, pre-amplifier stage, driver-amplifier stage and main-power amplifier stage. The main power amplifier stage is implemented with the power combiner, as a balanced amplifier structure, to obtain the power greater than 60 W. The designed SSPA modules has 50 dB gain, pulse period 1 msec, pulse width 100 us, 10 % duty cycle and 60 watts output power in the frequency range of 9.2~9.6 GHz and it can be applied to solid-state pulse compression radar using pulse SSPA.

An Availability Analysis Of Switching Control System with Hot Standby Fault Tolerant Architecture (Hot Standby 고장 감내 구조를 지원하는 교환 제어시스템의 가동률 분석)

  • Song, Gwang-Seok;Yeo, Hwan-Geun;Han, Chang-Ho;Mun, Tae-Su;Yu, Chung-Ryeol;Lee, Gwang-Bae;Kim, Hyeon-Uk;Yun, Chung-Hwa
    • The Transactions of the Korea Information Processing Society
    • /
    • v.2 no.6
    • /
    • pp.985-994
    • /
    • 1995
  • In this paper, we propose two hot standby architectures which not only provide high system availability but also lose little data on fault occurrence. In order to evaluate the performance of the proposed hot standby architectures, the warm standby architecture. In order to evaluate the performance of the propose d hot standby architectures, the warm standby architecture which is made from the hot standby architecture by eliminating its synchronization unit is considered. After system unavailability for each architecture is computed by using the corresponding Markov state diagram, the results are compared and evaluated. As the results, in most cases, hot standby architectures have higher availability than warm standby architecture. Also, hot standby architecture with external synchronization unit always maintains a little higher availability than hot standby architecture with internal synchronization unit. Active set time and personnel recovery rate for each architecture have little effect on system availability. However, in the case that data recovery time is too long, system availabilities of hot standby architectures and warm standby architecture degrade rapidly. In this case, the performance degradation of hot standby architectures is severe, and system availabilities of hot standby architectures eventually become lower than system availability of warm standby architecture.

  • PDF

Modulation Technique of Dual Active Bridge Converter to Improve Efficiency of Smart Transformers in Railroad Traction System (철도차량용 지능형 변압기 손실 저감을 위한 Dual Active Bridge 컨버터의 Modulation 기법 연구)

  • Kim, Sungmin;Lee, Seung-Hwan;Kim, Myung-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.6
    • /
    • pp.727-735
    • /
    • 2016
  • Smart transformers are effective at reducing the weight and increasing the efficiency of traction systems for railroad applications. A smart transformer generally consists of rectifier modules and the Dual-Active-Bridge (DAB) converter modules. The efficiency of the smart transformer depends on not only the electrical characteristics, but also on the control method of the converter modules. Especially, a DAB converter has a high order degree of freedom of voltage modulation to control the power transferred through the high frequency transformer, and a voltage modulation method, are very critical for the efficiency of the DAB converter. This paper proposes a new voltage modulation method for the DAB converter to increase the efficiency in the low/medium power transfer condition. The proposed modulation method controls the reactive power in the high frequency transformer, making it zero. And, the switching loss is dramatically reduced by using the received converter module as a diode rectifier. The feasibility of the proposed modulation method is verified by computer simulation of the 900Vdc DAB converter power control.

Extended Service Filtering Technique for Overload Control of Televoting Service Required for the Specialized Resources of Intelligent Peripheral (지능형 정보제공 시스템의 특수 지원을 이용하여 제공되는 전화투표 서비스의 과부하 제어를 위한 확장된 서비스 필터링 기법)

  • Jeong, Gwang-Je
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.7
    • /
    • pp.1727-1738
    • /
    • 1996
  • This paper proposes a extended service filtering technique to solve overload control problems inService Con-trol Poin(SCP) due to Televoting (VOT) services with heavy traffic characteristics. Also, this paper compares this new technique with existing IN overload control lechniques, and calculate steady state call blocking probabilities in In under overload conditions. The proposed technique considers SCP overload and IN CS-1services such as VOT service that need to use the specialized resources of IP. This technique uses first an activating step which SCP sends service filtering request to SSP and IP for the start of service filtering. Then, in the filtering step SSP sendas filtering results to SCP periodically or each N-calls.Also,when filtering time-out timer expired or call counter value exceeded maximum number of calls,SSP stops service filtering,and sends ser-vice filteing response to SCP in the deactivating step. The application of this techique to VOT service defined in IN CS-1 service is investigated and analyzed by using an analytical VOT service model.In order to apply this technique to VOT service, this paper also discusses VOT service and the corresponding N architecture including Service Switching Point(SSP),SCP and IP. Then this paper also constructs an analytical VOT service model,and calculates SCP and SSP/IP(circuit)call blocking probablities.With the application of this new technique,this paper shows good performance enhancements in SCP call blocking probability.

  • PDF

A design on low-power and small-area EEPROM for UHF RFID tag chips (UHF RFID 태그 칩용 저전력, 저면적 비동기식 EEPROM 설계)

  • Baek, Seung-Myun;Lee, Jae-Hyung;Song, Sung-Young;Kim, Jong-Hee;Park, Mu-Hun;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2366-2373
    • /
    • 2007
  • In this paper, a low-power and small-area asynchronous 1 kilobit EEPROM for passive UHF RFID tag chips is designed with $0.18{\mu}m$ EEPROM cells. As small area solutions, command and address buffers are removed since we design asynchronous I/O interface and data output buffer is also removed by using separate I/O. To supply stably high voltages VPP and VPPL used in the cell array from low voltage VDD, Dickson charge pump is designed with schottky diodes instead of a PN junction diodes. On that account, we can decrease the number of stages of the charge pump, which can decrease layout area of charge pump. As a low-power solution, we can reduce write current by using the proposed VPPL power switching circuit which selects each needed voltage at either program or write mode. A test chip of asynchronous 1 kilobit EEPROM is fabricated, and its layout area is $554.8{\times}306.9{\mu}m2$., 11% smaller than its synchronous counterpart.

A Study on the Effective Implementation of a Marine Incident System (준해양사고제도의 효율적 이행을 위한 개선방안에 관한 연구)

  • Chae, Byeong-Geun;Lee, Ho;Kim, Hong-Beom;Kang, Suk-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.4
    • /
    • pp.398-407
    • /
    • 2018
  • Standard guidelines for marine accident investigation have been prepared through the enforcement of the Casualty Investigation code as of January 2010. In addition, as the International Maritime Organization (IMO) recommended contracting the state to manage a marine incident system established under this code, Korea also has newly established provisions for a marine incident system in the 'Act on the Investigation of and Inquiry into Marine Accidents' also as of 2010. The Korean Maritime Safety Tribunal (KMST) has made a multilateral effort to prevent marine accidents through the efficient operation of a marine incident system, but this system has not been properly activated. This study examines the operational status and problems of a marine incident system and analyzes the marine incident systems of foreign countries and similar transportation agencies such as railroads and aviation. Options include switching to voluntary reporting of marine incidents, transferring responsibility to a non judicial private organization, expanding incentive systems for a marine incidents, revising regulation and preparing detailed implementation guidelines.

A Study on the Improvement of Reliability of Line Conversion Monitoring System using CCTV Camera (CCTV카메라를 활용한 선로전환감시시스템의 신뢰성 향상에 관한 연구)

  • Moon, Chae-young;Kim, Se-min;Ryoo, Kwang-ki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.400-402
    • /
    • 2019
  • The electric point machine, which is used for the control of the turnout used to change the track of the train, is very important in the railway system. Various wired and wireless real-time monitoring systems are used to check the status of the point machine, but there is a possibility of malfunction due to sensor or network error. In this paper, a redundant monitoring system was designed that incorporates the point machine monitoring system and the CCTV camera control system to double check the operation of the point machine. In the point machine monitoring system, the operating state of the railway converter is monitored, alarmed and transmitted over the network. The CCTV camera control system, which received this information, was required to record the status of the turnout and the point machine in question and send it to the administrator. The manager of the railway line can check the conversion status of the railway through the monitoring screen for the railway line switcher first, and then confirm the switching status directly through the CCTV camera image, thereby improving the reliability of the point machine operation. It will also enable the safe and efficient operation of personnel for management. It is expected to contribute to preventing a derailment caused by a malfunction of the point machine.

  • PDF