• 제목/요약/키워드: starting torque characteristics

검색결과 91건 처리시간 0.023초

유도 전동기의 동특성 해석 및 시험 (Analysis and test of dynamic characteristics of induction motor)

  • 장석명;박병임;이성호;이성래;윤기갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.55-57
    • /
    • 1999
  • To control induction motor we have to know about dynamic characteristics including torque characteristic. Simulation and test were made to get dynamic characteristics using LabVIEW and Matlab. We got experimental results(e.g current, torque, speed etc) from starting to steady state with changing of load.

  • PDF

대용량 유도기 기동 특성 모델링 및 전략적 기동 방법에 관한 연구 (Modeling and Strategic Startup Scheme for Large-Scaled Induction Motors)

  • 정원욱;신동열;이학주;윤기갑
    • 한국산학기술학회논문지
    • /
    • 제8권4호
    • /
    • pp.748-757
    • /
    • 2007
  • 본 논문은 대용량 유도전동기가 기동할 때 발생하는 큰 돌입전류로 인해 PCC(Point of Common Coupling)에 심한 전압 강하가 발생하게 되어 기동에 실패하는 문제를 해결하기 위해 대상 유도전동기의 기동 특성과 배전계통을 모델링하고 시뮬레이션을 수행함으로써 유도기 기동시에 전압저하 현상을 해석하였다. 문제가 되는 유도전동기는 2500KVA 용량의 펌프용 농형 유도전동기로 리액터 기동법을 채용하고 있다. 2500KVA 유도전동기 한대의 기동에는 문제가 없으나 기동 완료 후 PCC 전압이 다소 떨어진다. 하지만 추가로 동일 용량의 유도전동기가 기동하게 되면 PCC의 심한 전압강하로 기동에 실패하게 되는 문제가 발생하였다. 이러한 문제 해결을 위해 본 논문에서는 실제 기기의 기동시 토크-속도 곡선을 이용한 유도전동기의 기동 특성을 정확히 모델링하고 시뮬레이션을 수행하여 두 대의 대용량 유도전동기가 순차적으로 기동에 성공할 수 있는 적절한 전압보상 방안을 제안하였다. 본 논문에서 논의되는 대용량 유도전동기는 한국수자원공사의 취수장에서 운전되고 있으며 대상 유도전동기 및 배전계통은 PSCAD/EMTDC 소프트웨어를 사용하여 모델링 및 시뮬레이션을 수행하였다.

  • PDF

차량용 VVVF 인버터 제어시스템 개발 (Development of VVVF Inverter Control System for Propulsion System)

  • 김병섭;이규찬;이학성;김송웅;박영춘;김중한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.249-251
    • /
    • 1994
  • This paper introduces an implementation of high performance voltage source inverter system based on 16bit micro-processor and DSP for the application to modem rolling stock traction system. In contrast with other industry oriented inverter system, this system requires precise control action complying with various load condition and high overload capability. An asynchronous PWM generation and 3' pulse mode technology are adopted in order to improve compliant starting torque characteristics at starting phase and soft backward-forward starting motion.

  • PDF

새로운 권선법에 의한 권선형 유도전동기의 기동특성 (Staring Characteristic of Wound Rotor Induction Motor by New Winding Method)

  • 강만원
    • 조명전기설비학회논문지
    • /
    • 제13권4호
    • /
    • pp.27-31
    • /
    • 1999
  • 본 연구는 산업분야의 수많은 전기설비 시스템에 널리 사용되고 있으며 또 이중여자기로도 사용될 수 있는 권선형 유도전동기의 기동특성과 설계를 다루었다. 고정자는 재래색 3상 권선형 유도 전동기의 고정자와 동일하고 회전자 권선은 새로운 방법으로 재권선한 결과 기동토크로 크고 기동전류는 작으며 운전효율은 좋아졌다. 뿐만 아니라 슬립링과 브러쉬 및 외부저항의 필요성이 없어 구조가 간단하고 시스템 비용을 절약할 수 있을 뿐 아니라 유지보수비도 절약할 수 있었다.

  • PDF

자기동이 가능한 2상 SRM에 관한 연구 (The study for two phase SRM with self starting capability)

  • 오석규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.226-228
    • /
    • 2007
  • SRM drive systems are designed to meet operating standards such as low cost, constant torque independent of rotor position, a desired operating speed range, high efficiency, and high performance. In applications using small motors, low cost and high performance with self-starting capabilities are highly desired. This paper discusses a novel two phase SRM (TPSRM) that has high performance characteristics with self-starting capability, low manufacturing cost with a two phase inverter and simple magnetic structure, and high efficiency. The principle of operation, analysis, and simulation for design are presented. The machine design is verified using finite element analysis (FEA) software. Analysis and simulation results are given to validate the TPSRM design.

  • PDF

농업용 트랙터의 전후진 파워시프트 변속 특성 해석 (Analysis of Power Shuttle Characteristics of Agricultural Tractor)

  • 김대철;이호상;정병학;김경욱
    • Journal of Biosystems Engineering
    • /
    • 제27권6호
    • /
    • pp.479-490
    • /
    • 2002
  • A dynamic model of a power shuttle transmission was developed and its validity was verified using the experimental data obtained from a transmission test bench. A 40㎾, 4WD tractor was also modeled using an application software EASY5 to investigate parameters and their effects on the power shifting performance. For a tractor model, the manual reverse gear was replaced by a power shuttle transmission. The tractor model also included an engine, main-gears for transmission, wheels, differentials and planet gears. Using the tractor model, the effects of the parameters such as modulating pressure and time, engine speed, tractor speed. tractor weight. reverse to forward speed ratio and torsional damper on the transient characteristics at starting and shuttle shifting were investigated by the computer simulation. The transient characteristics were represented by variations in clutch pressure, torque transmitted to input shaft and driving wheels, and power transmission capacity of the clutch. It was found that the modulating pressure and time affected most significantly the torque transmission and shifting time. The input torque, axle torque, power transmission capacity of the clutch and transmission time all increased with increase in engine speed, tractor speed. tractor weight and ratio of reverse to forward speeds. However, the axle torque decreased with tractor speed. Both the axle torque and power transmission capacity of the clutch also decreased with the ratio of reverse to forward speeds.

앞선각 제어를 위한 단상 SRM 회전자설계 (Rotor Design of Single Phase Switched Reluctance Motor for Advance Angle Control)

  • 오주환;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.92-94
    • /
    • 2006
  • Single phase switched reluctance motor has a high speed capability, due to its very robust rotor, and requires only one electronic power switch in its control circuitry. The latter feature considerably reduces the cost of the drive system. But it involves starting problem and strongly torque ripple, which means that the motor is not suitable for application that require constant torque or speed. To solve torque ripple and region of these problem, this paper presents a single phase Switched Reluctance Motor model with a barrier rotor pole. Also it is simulated the designed prototype model by FEM for the prediction of characteristics.

  • PDF

Comparison of Starting Current Characteristics for Three-Phase Induction Motor Due to Phase-control Soft Starter and Asynchronous PWM AC Chopper

  • Thanyaphirak, Veera;Kinnares, Vijit;Kunakorn, Anantawat
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1090-1100
    • /
    • 2017
  • This paper presents the comparison of starting current characteristics of a three-phase induction motor fed by two types of soft starters. The first soft starter under investigation is a conventional AC voltage controller on the basis of a phase-control technique. The other is the proposed asynchronous PWM AC chopper which is developed from the conventional synchronous PWM AC chopper. In this paper, the proposed asynchronous PWM AC chopper control scheme is developed by generating only two asynchronous PWM signals for a three-phase main power circuit (6 switching devices) from a single voltage control signal which is compared with a single sawtooth carrier signal. By this approach, the PWM signals are independent and easy to implement since the PWM signals do not need to be synchronized with a three-phase voltage source. Details of both soft starters are discussed. The experimental and simulation results of the starting currents are shown. It is found that the asynchronous PWM AC chopper efficiently works as a suitable soft starter for the three-phase induction motor due to that the starting currents are reduced and are sinusoidal with less harmonic contents, when being compared with the starting current waveforms using the conventional phase-control starting technique. Also the proposed soft starter offers low starting electromagnetic torque pulsation.

Analysis of Slot Leakage Reactance of Submersible Motor with Closed Slots during Starting Transient Operation

  • Bao, Xiaohua;Di, Chong;Fang, Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.135-142
    • /
    • 2016
  • Generally, closed slots are adopted to reduce the water friction loss in both the stator and the rotor of water filling submersible motor due to the special environment of operation. One of the obvious differences between the traditional induction motors and water filling submersible motors is that the submersible motors only need relatively smaller starting torque. This paper aims to analyze the slot leakage reactance of water filling submersible motor during starting transient operation. An improved analytical method which considered the magnetic saturation of the slot bridge and the skin effect of rotor bars is proposed. The slot permeance factor which has a direct impact on the slot leakage reactance is calculated. Then finite element models with different stator slot types are constructed and search coils are introduced to measure the slot flux linkage. Moreover, the starting performances of the models with two typical stator slots are compared and the flux leakage characteristics are obtained. Finally, the results obtained by finite element method are very close to the results obtained by analytical method.

고속회전을 위한 Switched Reluctance Motor의 Advance Angle 변화에 따른 특성해석 (Speed Characteristics of Switched Reluctance Motor at High Speeds with Advance Angle Variation)

  • 조관열;임준영;신두진;김창현;김정철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.321-324
    • /
    • 1995
  • Switched reluctance motors and drives are increasingly used in high speed applications due to their robust mechanical structures, low inertia, and reduction in the rotor losses. The turn-on angle has to be advanced as the motor speed increases, but it may cause the starting problem in some rotor positions. In this paper, the characteristics of the maximum speed and input voltage with the advance angle at high speeds is investigated. To overcome the starting problem and reduce the torque ripple, conduction overlapping is added in adjacent phases. The effectiveness of conduction overlapping is verified through the simulation and experiments.

  • PDF