• Title/Summary/Keyword: start condition

Search Result 432, Processing Time 0.025 seconds

ON FIXED POINTS ON COMPACT RIEMANN SURFACES

  • Gromadzki, Grzegorz
    • Bulletin of the Korean Mathematical Society
    • /
    • v.48 no.5
    • /
    • pp.1015-1021
    • /
    • 2011
  • A point of a Riemann surface X is said to be its fixed point if it is a fixed point of one of its nontrivial holomorphic automorphisms. We start this note by proving that the set Fix(X) of fixed points of Riemann surface X of genus g${\geq}$2 has at most 82(g-1) elements and this bound is attained just for X having a Hurwitz group of automorphisms, i.e., a group of order 84(g-1). The set of such points is invariant under the group of holomorphic automorphisms of X and we study the corresponding symmetric representation. We show that its algebraic type is an essential invariant of the topological type of the holomorphic action and we study its kernel, to find in particular some sufficient condition for its faithfulness.

Tidal behavior changes in Mangyeong reservoir area with permitting sea-water intrusion through the sluice gate (만경수역 해수 유통시 조석환경변화 고찰)

  • Kwun, Soon-Kuk;Park, Yeong-Wook
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.21-24
    • /
    • 2001
  • As one of the phil-environmental alternative plan of Saemankeum project, gradual development is recommended. The procedure of the Saemankeum project start with the completion of 32 km long sea-dikes which contains two discharge gates until the year 2004. Second step is pre-development of Mangyoung area permitting temporary intrusion of sea water, i.e. tides, by the opening of discharge gate until the environmental evaluation on the water quality of this area secures permanent meet to government's water quality standard. Therefore this study is to predict the future condition of this tidal flat with the point of view tidal environments, salt, water quality, soil mechanics, etc. of Mangyoung area when the sea water still passed in the inland reservoir through the discharge gate.

  • PDF

Dynamic Adjustment of Ad hoc Traffic Indication Map(ATIM) window to save Power in IEEE 802.11 DCF

  • Nam, Jae-Hyun
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.3
    • /
    • pp.343-347
    • /
    • 2008
  • Wakeup schemes that turn off sensors' radio when communication is not necessary have great potential in energy saving. At the start of each beacon interval in the IEEE 802.11 power saving mode specified for DCF, each node periodically wakes up for duration called the ATIM Window. However, in the power saving mechanism specified in IEEE 802.11, all nodes use the same ATIM window size. Since the ATIM window size critically affects throughput and energy consumption, a fixed ATIM window does not perform well in all situations. This paper proposes an adaptive mechanism to dynamically choose an ATIM window size according to network condition. Simulation results show that the proposed scheme outperforms the IEEE 802.11 power saving mechanism in terms of the amount of power consumed and the packet delivery ratio.

First Principle Approach to Modeling of Primitive Quad Rotor

  • Sudiyanto, Tata;Muljowidodo, Muljowidodo;Budiyono, Agus
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.10 no.2
    • /
    • pp.148-160
    • /
    • 2009
  • By the development of recent technology, a new variant of rotorcrafts having four rotors start drawing attention from aerial-robotics engineers more than before. Its potential spans from just being control device test bed to performing difficult task such as carrying surveillance device to unreachable places. In this regards, modeling a quad-rotor is significant in analyzing its dynamic behavior and in synthesizing control system for such a vehicle. This paper summarizes the modeling of a mini quad-rotor aerial vehicle. A first principle approach is considered for deriving the model based on Euler-Newton equations of motion. The result of the modeling is a simulation platform that is expected to acceptably predict the dynamic behavior of the quad-rotor in various flight conditions. Linear models associated with different flight condition can be extracted for the purpose of control synthesis.

An introduction to present Research and Development condition about Solid Rocket Motor for Space Launch Vehicle (우주발사체용 고체 추진기관 개발현황 소개)

  • Kwon, Tae-Hoon;Shim, Myung-Sik;Song, Jong-Kwon;Lee, Won-Bok;Choi, Seong-Han;Suh, Hyuk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.623-626
    • /
    • 2009
  • Hanwha Corporation Daejeon Plant have developed apogee Kick Motor of KSLV-I that is the first among nation space launch vehicle for five years from 2003. Now, we are joining in KSLV-II(Korea Space Launch Vehicle-II) project and developing Pyro starter which is turbo pump for the first start-up of liquid propulsion supply.

  • PDF

ORTHODONTIC TREATMENT TIMING (교정치료시기에 관한 연구)

  • Chang, Young-Il
    • The Journal of the Korean dental association
    • /
    • v.22 no.12 s.187
    • /
    • pp.1067-1073
    • /
    • 1984
  • In the treatment of functional orthodontic problems, timing is not an issue. All orthodontists start as soon as the condition is recognized. However, there is an active dialogue concerning treatment timing for structure problems. The major points in contention center around the operator's ability is to control the growth of the facial bones and to maintain post-treatment tooth position through the maturation period (especially when this position was gained by techniques involving arch expansion or distal driving of posterior segments). Factors taken into account to determine the best time of orthodontic treatment include diagnosis, interception, growth rate, patient cooperation, eruptive state and treatment period. With those exceptions of all functional problems, mild dental discrepancies and skeletal deficiencies with a predictably excellent growth potential (early treatment), the period immediately following the eruption of the permanent second molars is the period during which most orthodontic treatment should be initiated. At this time the full volume of tooth substances is present, the individual growth pattern in well established, there are sufficient teeth to receive nearly any type of appliances and the patient can easily tolerate the wearing of appliances.

  • PDF

A Study on Concentration of Volatile Organic Compounds in the Apartment House (실내공기중의 휘발성유기화합물 농도변화에 관한 연구)

  • Lee, Yun-Gyu
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.129-136
    • /
    • 2004
  • Recently, indoor air pollution has been seriously apprehended, and became a striking issue, due to the airtightness of buildings or the misuse of building materials. Especially, SHS(Sick House Syndrome) and MCS(Multi Chemical Sensitivity) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. The emission rates of VOCs is sensitively affected by the indoor/outdoor condition, construction materials, construction method, and character of ventilation facilities. Therefore, in this study, by measuring the indoor air pollution substance of the existing apartment house, the problem over this tends to be grasped and it is going to secure an improvement methods.

Decomposition Characteristics of Benzene by Microwave

  • Kim, Dong-Sik;Kim, Jeong-Young;Lee, Dong-Kyu
    • Carbon letters
    • /
    • v.1 no.3_4
    • /
    • pp.143-147
    • /
    • 2001
  • Under the irradiation of radiofrequency wave, the dipole materials vibrate as microwave phase changes. This causes friction between adjacent molecules and enables an unique characteristics of interior heating of the materials. Using this principle, when harmful material pass through anthracite- bed which play a role as a absorber of radiofrequency wave, the material can be easily decomposed by the microwave energy. To remove benzene vapour and other solvents in the process of industry, we examined decomposition of benzene in this manner. It was found that benzene was decomposed to the methane, ethane, propane and butane, etc. during passing through the carbon-bed under the microwave impingement and distribution of methane in the products reached about 85 vol.%. The decomposition rate of benzene was high within 5 minutes from start of reaction. For a lower concentration of benzene gas, general cases in the field of industry, almost complete decomposition of benzene is believed possible and this method is surely expected to be useful for the prevention of air pollution and improvement of ambient condition.

  • PDF

Analysis of Impact on Voltage Stability by Starting Synchronous Condenser in Jeju AC Network (제주계통에서 동기조상기 기동에 따른 전압안정도 영향 검토)

  • Choi, Soon-Ho;Lee, Seong-Doo;Kim, Chan-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.23-28
    • /
    • 2015
  • Two old synchronous condensers in Jeju are being replaced by new machines to operate Jeju AC network with Haenam-Jeju HVDC system stably. Before new synchronous condensers operate on site, voltage stability analysis is conducted to verify stable operation of jeju AC network. Through impedance analysis of the synchronous machine, transformer and ac network, the equivalent circuit is constructed and the voltage drop during start-up is calculated. Then, PSS/E fault analysis is performed to acquire short-circuit capacity according to the generator operation scenarios. Voltage variation when starting synchronous condenser is simulated in PSCAD/EMTDC and satisfies the operating condition of jeju AC network and HVDC #1 system.

Performance Test of MGT Combined Heat & Power System (마이크로 가스터빈 열병합 발전시스템 성능평가)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.313-316
    • /
    • 2006
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. Korea Electric Power Corporation (KEPCO) has researched performance characteristics of the 60k W class 1) basic start-up & shutdown operation analysis 2) interconnection test 3) MGT -absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF