• 제목/요약/키워드: standards for installation

검색결과 473건 처리시간 0.023초

건설현장 이동식 비계의 사망사고 분석을 통한 안전기준 개선 방안 (Revision of Safety Standards through Analysis of Fatal Accidents Related to Mobile Scaffold in Construction Sites)

  • 박주동
    • 한국안전학회지
    • /
    • 제38권1호
    • /
    • pp.42-54
    • /
    • 2023
  • Mobile scaffold is used as a work platform in construction sites. According to industrial accident data, 10 fatalities occur annually on average due to falling from mobile scaffold in construction sites. To prevent such fatal accidents, safety standards must be improved by analyzing the causes of fatal accidents related to mobile scaffold. Accordingly, we analyzed domestic and international safety standards for mobile scaffold and analyzed the fatalities (117 persons) caused by mobile scaffold accidents in domestic construction sites during 2011-2020 and found that fall, overturn, and collapse accounted for 88% (103 persons), 10.3% (12 persons), and 1.7% (2 persons) of fatalities, respectively. The main causes of fatal accidents were found to be non-installation or insufficient installation of safety rails and outriggers and incorrect sequence of work. Based on the analysis results, we proposed strategies for improving the safety standards, such as the use of advanced guard rails and wheel-attached outriggers, to enhance the safety and field applicability of the mobile scaffold. Technology development and improvements in the safety standards for the use of mobile scaffold will aid in the prevention of fatal accidents caused by mobile scaffold.

철근콘크리트 구조물 내의 철근을 활용한 피뢰설비 인하도선의 설치방법에 관한 연구 (A Study on the Installation Method of Down Conductors of the Lightning Protection System, using Rebar in Reinforced Concrete Structures)

  • 이영철;이주철
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.101-107
    • /
    • 2013
  • IEC Standards on lightning protection system specify the use of natural components as down conductors. This paper provides an analysis of problems revealed from our field investigation and survey conducted for the relevant experts in the construction site where natural components are used as down conductors. It also considers a suitable condition for installing natural components as down conductors in accordance with the latest version of the standard. As a result, when rebars of reinforced concrete are used as down conductors, vertical bars consisting of rebars of which thickness is not less than D13($127mm^2$) should be connected by welding, clamps or bound joints, using appropriate connection components conforming to IEC Standards. The lashed joints, however, shall not be applied for down conductors.

인체감전 안전기준에 관한 최근 국제규격의 동향 (Recent Trend of International Standards on the Safety Criteria for Electric Shock Protection)

  • 이종철;김한수;이주철;강성만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.189-193
    • /
    • 2007
  • The grounding of an electrical system is one of the essential elements for public safety. Domestic practice of grounding system design has been to get grounding resistance values which are classified by facilities or equipment in the regulations. But the concept of grounding system design of IEC is, as a main factor of safety index, to consider touch voltage and step voltage instead of the resistance value itself. Recently IEC actively develops or revises safety related standards which are essential for the grounding system performance. In this paper, we present the recent trend of the international standards on the safety criteria for Electric Shock Protection.

  • PDF

건물용 연료전지-보일러 복합설치 안전성능 평가에 관한 연구 (A Study on the Assessment of Safety Performance for Complex Installation System of Stationary Fuel Cell and Boiler)

  • 김민우;이은경;오건우;이정운;이승국
    • 한국위험물학회지
    • /
    • 제6권2호
    • /
    • pp.77-86
    • /
    • 2018
  • Interest in renewable energy is increasing for eco-friendly use of energy, and fuel cells are being used in various ways such as houses and buildings as power generation methods that have low emissions such as $NO_X$ and $CO_2$. As the supply of fuel cells expands, more and more boilers are installed in the existing buildings, but safety management is not being performed properly. Therefore, in this study, a prior study was conducted on the status of fuel cell-boiler complex installation and related criteria, and the risk factors were analyzed according to the installation environment and structure. Based on these standards, the safety performance of the fuel cell-boiler combined installation is assessed by conducting a demonstration using the starting product of the simulated operation to derive the installation criteria (proposal) for the fuel cell-boiler combined installation. The installation criteria (proposal) include the construction and connection method of the piping according to the fuel cell-boiler complex installation.

초소형자동차의 자동차안전기준에 대한 효과분석 (Assessment of Vehicle Safety Standard Requirements for New Micro-mobility Vehicle)

  • 장정아;심소정
    • 한국자동차공학회논문집
    • /
    • 제25권2호
    • /
    • pp.190-200
    • /
    • 2017
  • In general, an assessment of the benefits and costs with regard to vehicle safety standards are validated before regulations are implemented. This paper performs this validation for the mandatory automobile safety devices requirement for new micro-mobility. The reviewed car safety standards involved the installation of seat belts, airbags, ABS, crash speed standards, and pedestrian warning system. The benefit was estimated as the cost of accident reduction due to the installation of vehicle safety standards. As a result, the safety belt showed a B / C of 4.0 or higher, and it was found that the seat belt should be installed from 2017. After the seatbelt regulation in 2017, the results of the scenarios with the airbag, ABS, crash speed of 40 km/h, and the pedestrian warning system showed B / C of 1.0 or more according to the year of regulation. This study can be useful as a tool in the decision-making process with regard to the timing and type of vehicle safety standards requirement of micro-mobility in the future.

빛공해 방지를 위한 관리기준 및 조명환경관리구역 설정 방안에 관한 연구 (A Study on the Control Standards and an Environmental Lighting Zone-Setting method for Making Light Pollution Management)

  • 김기태;오민석;김회서
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.27-33
    • /
    • 2011
  • This study aims to suggest some problems, which occur when environmental lighting zone is set by use-zone only, by comparing and analyzing the artificial illumination luminance. In addition, this study aims to review the control standards of light pollution and to suggest a practical environmental lighting zone-setting method. I checked out the standards of average surface luminance and luminance contrast as for light pollution management. In addition, I did some research on evaluation of light pollution on surroundings based on investigation of use-environment as for lighting environment setting method.

국제시험규격에 적합한 뇌서지 시험설비 구축 (Installation of Test Equipment for Lightning Surge Complying with International Standard)

  • 이태형;조성철;엄주홍;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.360-364
    • /
    • 2006
  • Recently KS documents related to lightning protection were revised complying with the requirements of IEC standards. Lightning protection parts are divided three in IEC, those are arrestor(60099), SPD(61643), and protection facilities(62305). According as international standard is applicable in Korea, type tests, routine tests, and acceptance tests shall be made to demonstrate compliance with the relevant standards. KESRI have installed test equipment which is funded by Ministry of Commerce, Industry and Energy fit for lightning surge test form 2002, and we introduce the test equipments in detail.

  • PDF

식품공장 건축물 바깥쪽으로의 출구 설치기준에 따른 RSET 분석 (Analysis of RSET According to Exit Installation Standards for the Exterior of a Food Manufacturing Plant Building)

  • 박하성;이재욱;공하성
    • 문화기술의 융합
    • /
    • 제10권2호
    • /
    • pp.201-208
    • /
    • 2024
  • 이 연구는 식품공장에서 건축법 제39조(건축물 바깥쪽으로의 출구 설치), 건축물의 피난·방화구조 등의 기준에 관한 규칙 제11조(건축물 바깥쪽으로의 출구의 설치기준)을 기준에 따라 각 거실로부터 60m, 80m, 100m거리에 출구를 설치했을 때 소방청에서 명시한 소방청 고시 행정규칙인 '소방시설 등의 성능위주설계 방법 및 기준'의 [별표 1]에서 제시하는 화재 및 피난 시뮬레이션의 시나리오 작성 기준 중 W3인 최악의 상황으로 4분(240초)이내에 피난을 성공하여 피난 안전성 평가를 진행하였다. 피난시뮬레이션을 위해 미국 Thunder사의 Pathfinder프로그램을 사용하였다. 본 연구 대상 건축물은 내화구조로 각 거실로부터 100m거리 이내에 출구가 설치되면 건축법에 만족하는 건물이었지만 실험 결과 각 거실로부터 60m거리에 출구가 있을때만 피난 안전성이 지켜졌으며, 80m, 100m거리에 출구를 설치했을 경우 피난안전성이 지켜지지 않고 피난에 실패하는 재실자가 발생하였다. 본 연구에서는 출구 설치기준이 각 거실로부터 100m일 때 비해 60m일 때 피난 소요시간이 47.5%나 줄어들 수 있다는 큰 연구성과를 보여주었다.

Portable Calibration System for Displacement Measuring Sensors

  • Eom, Tae-Bong;Lee, Jae-Yun;Kim, Jae-Wan;Joon, Lyou
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권2호
    • /
    • pp.56-59
    • /
    • 2006
  • A vibrational model of powder transfer equipment based on the lumped parameter method was developed, in which the operating motion consists of surging, bouncing, and pitching. After decoupling the equation of motion, the vibrational excitation source of the pitching motion was removed. So the designers are able to plan the optimum design to adjust the motion trajectory of the powder transfer equipment. That is, a procedure to adjust the motion trajectory of powder transfer equipment by changing design specifications such as the installation position, the direction of the motor, the driving speed, the mass unbalance, the stiffness coefficient, and the installation position of the support spring, is presented in this paper. The powder transfer equipment manufactured according to the results of this study did not suffer fatigue destruction, since the maximum stress on the basket structure was sufficiently small.

Power LED의 신뢰성 평가 규격 비교 연구 (The Study based on Comparison with Reliability Assessment Standards for Power LEDs(Light Emitting Diodes))

  • 박창규;조상묵;이민진;김진선;김정수;정희석;이영주
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.216-219
    • /
    • 2008
  • The Power LED is more much than 1W and appliable to lights that is different from signal LED. In this paper we investigated types of tests in reliability assessment standards on Power LED. we make comparison of that military standards, JEITA(Japan Electronics and Information Technology Industries Association) and JEDEC(Joint Electron Device Engineering Council) with RS(reliability standard). Reliability tests should be considered that informations can be obtained from requirements of a real system Therefore, The paper aided companies to criteria for reliability tests by themselves.

  • PDF