• 제목/요약/키워드: standardized uptake value

검색결과 113건 처리시간 0.044초

Diagnostic Performance of Diffusion Weighted Imaging of Malignant and Benign Pulmonary Nodules and Masses: Comparison with Positron Emission Tomography

  • Usuda, Katsuo;Sagawa, Motoyasu;Motono, Nozomu;Ueno, Masakatsu;Tanaka, Makoto;Machida, Yuichiro;Maeda, Sumiko;Matoba, Munetaka;Kuginuki, Yasuaki;Taniguchi, Mitsuru;Tonami, Hisao;Ueda, Yoshimichi;Sakuma, Tsutomu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권11호
    • /
    • pp.4629-4635
    • /
    • 2014
  • Background: Diffusion-weighted imaging (DWI) makes it possible to detect malignant tumors based on the diffusion of water molecules. However, it is uncertain whether DWI has advantages over FDG-PET for distinguishing malignant from benign pulmonary nodules and masses. Materials and Methods: One hundred-forty-three lung cancers, 17 metastatic lung tumors, and 29 benign pulmonary nodules and masses were assessed in this study. DWI and FDG-PET were performed. Results: The apparent diffusion coefficient (ADC) value ($1.27{\pm}0.35{\times}10^{-3}mm^2/sec$) of malignant pulmonary nodules and masses was significantly lower than that ($1.66{\pm}0.58{\times}10^{-3}mm^2/sec$) of benign pulmonary nodules and masses. The maximum standardized uptake value (SUVmax: $7.47{\pm}6.10$) of malignant pulmonary nodules and masses were also significantly higher than that ($3.89{\pm}4.04$) of benign nodules and masses. By using optimal cutoff values for ADC ($1.44{\times}10^{-3}mm^2/sec$) and for SUVmax (3.43), which were determined with receiver operating characteristics curves (ROC curves), the sensitivity (80.0%) of DWI was significantly higher than that (70.0%) of FDG-PET. The specificity (65.5%) of DWI was equal to that (65.5%) of FDG-PET. The accuracy (77.8%) of DWI was not significantly higher than that (69.3%) of FDG-PET for pulmonary nodules and masses. As the percentage of bronchioloalveolar carcinoma (BAC) component in adenocarcinoma increased, the sensitivity of FDG-PET decreased. DWI could not help in the diagnosis of mucinous adenocarcinomas as malignant, and FDG-PET could help in the correct diagnosis of 5 out of 6 mucinous adenocarcinomas as malignant. Conclusions: DWI has higher potential than PET in assessing pulmonary nodules and masses. Both diagnostic approaches have their specific strengths and weaknesses which are determined by the underlying pathology of pulmonary nodules and masses.

The Imaging Features of Desmoid Tumors: the Usefulness of Diffusion Weighted Imaging to Differentiate between Desmoid and Malignant Soft Tissue Tumors

  • Lee, Seung Baek;Oh, Soon Nam;Choi, Moon Hyung;Rha, Sung Eun;Jung, Seung Eun;Byun, Jae Young
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권3호
    • /
    • pp.162-170
    • /
    • 2017
  • Purpose: To evaluate the imaging findings of desmoid tumors using various imaging modalities and to evaluate whether diffusion-weighted imaging (DWI) can help differentiate between desmoid and malignant tumors. Materials and Methods: The study included 27 patients with pathologically confirmed desmoid tumors. Two radiologists reviewed 23 computed tomography (CT), 12 magnetic resonance imaging (MRI) and 8 positron emission tomography-computed tomography (PET-CT) scans of desmoid tumors and recorded data regarding the shape, multiplicity, size, location, degree of enhancement, and presence or absence of calcification or hemorrhage. The signal intensity of masses on T1- and T2-weighted imaging and the presence or absence of whirling or band-like low signal intensity on T2-weighted imaging were recorded. The apparent diffusion coefficient (ADC) values of the desmoid tumors in nine patients with DWIs were compared with the ADC values of 32 malignant tumors. The maximum standardized uptake value ($SUV_{max}$) on PET-CT images was measured in 8 patients who underwent a PET-CT. Results: The mean size of the 27 tumors was 6.77 cm (range, 2.5-26 cm) and four tumors exhibited multiplicity. The desmoid tumors were classified by shape as either mass forming (n = 18), infiltrative (n = 4), or combined (n = 5). The location of the tumors was either intra-abdominal (n = 15), within the abdominal wall (n = 8) or extra-abdominal (n = 4). Among the 27 tumors, 21 showed moderate to marked enhancement and 22 showed homogeneous enhancement. Two tumors showed calcifications and one displayed hemorrhage. Eleven of the 12 MR T2-weighted images showed whirling or band-like low signal intensity areas in the mass. The mean ADC value of the desmoid tumors ($1493{\times}10^{-6}mm^2/s$) was significantly higher than the mean of the malignant soft tissue tumors ($873{\times}10^{-6}mm^2/s$, P < 0.001). On the PET-CT images, all tumors exhibited an intermediate $SUV_{max}$ (mean, 3.7; range, 2.3-4.5). Conclusion: Desmoids tumors showed homogenous, moderate to marked enhancement on CT and MRI scans and a characteristic whirling or band-like pattern on T2-weighted images. DWI can be useful for the differentiation of desmoid tumors from malignant soft tissue tumors.

Prognostic value of nodal SUVmax of 18F-FDG PET/CT in nasopharyngeal carcinoma treated with intensity-modulated radiotherapy

  • Lee, So Jung;Kay, Chul-Seoung;Kim, Yeon-Sil;Son, Seok Hyun;Kim, Myungsoo;Lee, Sea-Won;Kang, Hye Jin
    • Radiation Oncology Journal
    • /
    • 제35권4호
    • /
    • pp.306-316
    • /
    • 2017
  • Purpose: To investigate the predictive role of maximum standardized uptake value ($SUV_{max}$) of 2-[$^{18}F$]fluoro-2-deoxy-D-glucose($^{18}F-FDG$) positron emission tomography/computed tomography (PET/CT) in nasopharyngeal cancer patients treated with intensity-modulated radiotherapy (IMRT). Materials and Methods: Between October 2006 and April 2016, 53 patients were treated with IMRT in two institutions and their PET/CT at the time of diagnosis was reviewed. The $SUV_{max}$ of their nasopharyngeal lesions and metastatic lymph nodes (LN) was recorded. IMRT was delivered using helical tomotherapy. All patients except for one were treated with concurrent chemoradiation therapy (CCRT). Correlations between $SUV_{max}$ and patients' survival and recurrence were analyzed. Results: At a median follow-up time of 31.5 months (range, 3.4 to 98.7 months), the 3-year overall survival (OS) and disease-free survival (DFS) rates were 83.2% and 77.5%, respectively. In univariate analysis, patients with a higher nodal pre-treatment $SUV_{max}$ (${\geq}13.4$) demonstrated significantly lower 3-year OS (93.1% vs. 55.5%; p = 0.003), DFS (92.7% vs. 38.5%; p < 0.001), locoregional recurrence-free survival (100% vs. 50.5%; p < 0.001), and distant metastasis-free survival (100% vs. 69.2%; p = 0.004), respectively. In multivariate analysis, high pre-treatment nodal $SUV_{max}$ (${\geq}13.4$) was a negative prognostic factor for OS (hazard ratio [HR], 7.799; 95% confidence interval [CI], 1.506-40.397; p = 0.014) and DFS (HR, 9.392; 95% CI, 1.989-44.339; p = 0.005). Conclusions: High pre-treatment nodal $SUV_{max}$ was an independent prognosticator of survival and disease progression in nasopharyngeal carcinoma patients treated with IMRT in our cohort. Therefore, nodal $SUV_{max}$ may provide important information for identifying patients who require more aggressive treatment.

CT 촬영 조건에 따른 PET 영상의 변화 (Change of PET Image According to CT Exposure Conditions)

  • 박재윤;김정훈;이용기
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.473-479
    • /
    • 2019
  • 다양한 촬영 조건의 CT 감쇠 지도가 PET 영상에 영향을 미치는지 알아보기 위하여 다양한 kVp와 mA조건에서 Uniformity phantom 영상의 신호 강도(SI; Signal Intensity)와 표준 섭취율 계수(SUV; Standardized Uptake Value)를 측정하고, CTDI (Computed Tomography Dose Index)를 통해 각 조건에 따른 피폭선량을 측정하였다. 또한 동일한 조건에서 Resolution phantom의 반치폭(FWHM; Full Width at Half Maximum)을 측정하여 CT의 kVp와 mA에 따른 PET 영상의 화질 변화에 대하여 정량적으로 알아보고자 하였다. 연구 결과, CT의 촬영 조건은 PET 영상에는 영향을 주지 않는 것으로 나타났으나, CT의 촬영 조건이 감소하게 되면 방사선 피폭이 감소하게 되지만 영상에 영향을 미치게 되므로 향후 진단이 가능한 CT 화질을 유지하면서 방사선 피폭을 최소화할 수 있는 양전자 방출 단층 촬영(PET/CT; Positron Emission Tomography / Computed Tomography)의 촬영 조건에 대한 연구가 지속적으로 되어야 할 것이다.

Prognostic Value of 18F-FDG PET/CT Radiomics in Extranodal Nasal-Type NK/T Cell Lymphoma

  • Yu Luo;Zhun Huang;Zihan Gao;Bingbing Wang;Yanwei Zhang;Yan Bai;Qingxia Wu;Meiyun Wang
    • Korean Journal of Radiology
    • /
    • 제25권2호
    • /
    • pp.189-198
    • /
    • 2024
  • Objective: To investigate the prognostic utility of radiomics features extracted from 18F-fluorodeoxyglucose (FDG) PET/CT combined with clinical factors and metabolic parameters in predicting progression-free survival (PFS) and overall survival (OS) in individuals diagnosed with extranodal nasal-type NK/T cell lymphoma (ENKTCL). Materials and Methods: A total of 126 adults with ENKTCL who underwent 18F-FDG PET/CT examination before treatment were retrospectively included and randomly divided into training (n = 88) and validation cohorts (n = 38) at a ratio of 7:3. Least absolute shrinkage and selection operation Cox regression analysis was used to select the best radiomics features and calculate each patient's radiomics scores (RadPFS and RadOS). Kaplan-Meier curve and Log-rank test were used to compare survival between patient groups risk-stratified by the radiomics scores. Various models to predict PFS and OS were constructed, including clinical, metabolic, clinical + metabolic, and clinical + metabolic + radiomics models. The discriminative ability of each model was evaluated using Harrell's C index. The performance of each model in predicting PFS and OS for 1-, 3-, and 5-years was evaluated using the time-dependent receiver operating characteristic (ROC) curve. Results: Kaplan-Meier curve analysis demonstrated that the radiomics scores effectively identified high- and low-risk patients (all P < 0.05). Multivariable Cox analysis showed that the Ann Arbor stage, maximum standardized uptake value (SUVmax), and RadPFS were independent risk factors associated with PFS. Further, β2-microglobulin, Eastern Cooperative Oncology Group performance status score, SUVmax, and RadOS were independent risk factors for OS. The clinical + metabolic + radiomics model exhibited the greatest discriminative ability for both PFS (Harrell's C-index: 0.805 in the validation cohort) and OS (Harrell's C-index: 0.833 in the validation cohort). The time-dependent ROC analysis indicated that the clinical + metabolic + radiomics model had the best predictive performance. Conclusion: The PET/CT-based clinical + metabolic + radiomics model can enhance prognostication among patients with ENKTCL and may be a non-invasive and efficient risk stratification tool for clinical practice.

Development and Validation of 18F-FDG PET/CT-Based Multivariable Clinical Prediction Models for the Identification of Malignancy-Associated Hemophagocytic Lymphohistiocytosis

  • Xu Yang;Xia Lu;Jun Liu;Ying Kan;Wei Wang;Shuxin Zhang;Lei Liu;Jixia Li;Jigang Yang
    • Korean Journal of Radiology
    • /
    • 제23권4호
    • /
    • pp.466-478
    • /
    • 2022
  • Objective: 18F-fluorodeoxyglucose (FDG) PET/CT is often used for detecting malignancy in patients with newly diagnosed hemophagocytic lymphohistiocytosis (HLH), with acceptable sensitivity but relatively low specificity. The aim of this study was to improve the diagnostic ability of 18F-FDG PET/CT in identifying malignancy in patients with HLH by combining 18F-FDG PET/CT and clinical parameters. Materials and Methods: Ninety-seven patients (age ≥ 14 years) with secondary HLH were retrospectively reviewed and divided into the derivation (n = 71) and validation (n = 26) cohorts according to admission time. In the derivation cohort, 22 patients had malignancy-associated HLH (M-HLH) and 49 patients had non-malignancy-associated HLH (NM-HLH). Data on pretreatment 18F-FDG PET/CT and laboratory results were collected. The variables were analyzed using the Mann-Whitney U test or Pearson's chi-square test, and a nomogram for predicting M-HLH was constructed using multivariable binary logistic regression. The predictors were also ranked using decision-tree analysis. The nomogram and decision tree were validated in the validation cohort (10 patients with M-HLH and 16 patients with NM-HLH). Results: The ratio of the maximal standardized uptake value (SUVmax) of the lymph nodes to that of the mediastinum, the ratio of the SUVmax of bone lesions or bone marrow to that of the mediastinum, and age were selected for constructing the model. The nomogram showed good performance in predicting M-HLH in the validation cohort, with an area under the receiver operating characteristic curve of 0.875 (95% confidence interval, 0.686-0.971). At an appropriate cutoff value, the sensitivity and specificity for identifying M-HLH were 90% (9/10) and 68.8% (11/16), respectively. The decision tree integrating the same variables showed 70% (7/10) sensitivity and 93.8% (15/16) specificity for identifying M-HLH. In comparison, visual analysis of 18F-FDG PET/CT images demonstrated 100% (10/10) sensitivity and 12.5% (2/16) specificity. Conclusion: 18F-FDG PET/CT may be a practical technique for identifying M-HLH. The model constructed using 18F-FDG PET/CT features and age was able to detect malignancy with better accuracy than visual analysis of 18F-FDG PET/CT images.

PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향 (The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media)

  • 안샤론;박훈희;박민수;오신현;이승재;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.77-81
    • /
    • 2009
  • PET/CT (Positron Emission Tomography/ Computed Tomography)의 PET은 생체의 생리, 화학적인 정보를 정량적으로 영상화할 수 있지만 해부학적인 구조를 명확히 나타내는 데에는 한계를 가지고 있어 PET에 CT를 접목시켜 해상력을 높임은 물론, CT 데이터를 감쇠보정에 이용하여 촬영시간도 단축시키고 잡음제거 측면에서도 우수함을 나타내고 있다. 또한 CT 검사 시 조영제를 사용함으로써 병변의 정확한 범위를 확인하고 정상 구조물을 구별하는데 용이하여 조영제의 사용이 증가하고 있는 추세이다. 하지만 조영제를 사용한 경우 CT 영상의 보정에 따라 PET/CT 영상에서 표준화섭취계수(Standardized Uptake Value: SUV)에 영향을 미치기 때문에 본 연구에서는 조영제 보정에 따라 표준화섭취계수(SUV)에 미치는 정도를 평가하였다. 2008년 4월에서 7월 사이에 본원에서 PET/CT검사를 시행한 환자 중 요오드 조영제에 대한 부작용이 없고 당뇨병이 없는 환자 30명을 대상으로 (남: 20, 여: 10, 연령범위: 연령범위 27세~72세, 평균나이 49.6세) 후향적 조사를 하였다. 장비는 DSTe (General Electric Healthcare, Milwaukee, MI, USA)를 사용하였다. 검사자에게 $^{18}F$-FDG 370~555 MBq를 몸무게에 따라 주사하였으며, 1시간 정도의 안정된 자세를 취한 후 검사를 시행하였다. CT촬영은 140 kV, 210 mA로 설정하였으며 CT 검사에 사용되는 조영제의 양은 환자 몸무게 1 kg당 2 cc를 주입하였다. 검사 후 최초 획득 데이터(raw data)를 이용하여 조영제 영향을 보정한 CT데이터와 보정을 하지 않은 CT데이터로 감쇠보정을 하여 영상을 얻었으며 각 영상의 간, 심장, 폐에 관심영역(Region of Interest: ROI)를 그려 SUV를 측정하여 비교하였다. SUV를 측정한 결과 조영제 보정을 한 영상의 표준화섭취계수(SUV)가 줄어듦을 알 수 있었다. 조영제에 대한 영향이 거의 없는 폐에서는 수치적인 변화가 거의 나타나지 않았으며 통계적으로도 유의하지 않았다. 비교적 혈류가 풍부한 간과 심장에서 조영제 보정으로 인한 표준화 섭취계수(SUV) 값이 수치적인 차이를 보였으나 간에서만 통계적으로 유의했다. PET/CT 검사에서 조영제의 사용으로 인하여 검사하고자 하는 부위의 대조도를 증강시켜 진단의 효율성을 높이고 있지만 이로 인하여 표준화섭취계수(SUV)의 증가가 일어난다. 따라서 조영제를 사용한 CT로 감쇠보정을 할 경우에 조영제의 영향에 대한 보정을 해주어 고해상력의 해부학적 영상뿐만 아니라 신뢰를 할 수 있는 반정량적 방법으로 진단적 가치를 더욱 높일 수 있을 것이며 다른 장기에 대해서도 추가적인 연구가 필요하다고 생각된다.

  • PDF

FDG-PET 검사시 우연히 발견한 양성 이하선 병변: 유병율과 임상 및 병리 소견 (Incidental Benign Parotid Lesions on FDG-PET: Prevalence and Clinico-pathologic Findings)

  • 임일한;이원우;정진행;박소연;김상희;김유경;김상은
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권5호
    • /
    • pp.359-363
    • /
    • 2007
  • 목적 : FDG-PET을 시행하였을 때 이하선에서 우연히 발견되는 FDG 섭취병변은 원발암의 원격 전이로 오인될 수 있다. 이러한 이하선의 우연한 FDG 섭취병변에 대한 유병률과 임상-병리학적 소견에 관한 연구는 아직 시행되지 않았다. 본 연구에서는 FDG-PET검사시 우연히 발견된 이하선 FDG 섭취병변의 유병률과 악성위험도를 평가하였다. 대상 및 방법 : 본 병원에서 2003년 5월부터 2006년 12월까지 FDG-PET을 시행한 3,344명의 환자가 대상이었다. 이중 3,212명은 암이 알려져 있거나 암이 의심되어 FDG-PET을 시행하였으며, 132명은 암 조기 검진 목적으로 FDG-PET을 시행하였다. 이하선의 우연한 FDG 섭취병변은 이하선이 현재 FDG-PET을 실시한 관심병소가 아니면서 육안적으로 평가하였을 때 반대편 이하선보다 FDG 섭취가 국소적으로 증가되어 있는 경우로 정의하였다. FDG 섭취 정도는 최대 SUV값 (maxSUV)으로 제시하였다. 최종 진단은 병리학적 검사소견이나 임상적인 추적관찰결과를 토대로 하였다. 결과 : 15명 (0.45% = 15/3,344)의 환자에서 이하선의 우연한 FDG 섭취병변이 관찰되었으며, 이들은 모두 양성병변을 시사하는 소견을 나타내었다. MaxSUV의 범위는 1.7 에서 8.6(평균${\pm}$표준편차=$3.7{\pm}1.9$) 이었다. 최종 진단은 2명이 Warthin 종양, 1명이 pleomorphic adenoma, 다른 1명은 비특이적 양성 병변, 3명의 환자는 영상검사 추적결과 유의한 변화가 관찰되지 않았고, 8명의 환자는 임상적 추적관찰에서 유의한 변화가 관찰되지 않았다. 결론 : 본 연구에서 FDG-PET 검사시 우연히 이하선에 FDG 섭취를 보이는 병변이 0.45%의 유병률로 나타났으며 모두 양성병변을 시사하는 소견을 나타냈다. 우연히 이하선에 FDG 섭취를 보이는 병변이 발견될 경우 PET이나 CT를 이용한 면밀한 영상검사로 추적관찰을 하는 것이 병변의 진단을 위한 합리적인 접근방법이라고 생각된다.

폐 종양 FDG PET 영상의 다양한 추적자 역학 분석 방법 개발과 유용성 고찰 (Assessment of Quantitative Analysis Methods for Lung F-18-Fluorodeoxyglucose PET)

  • 김준영;최용;최준영;이경한;김상은;최연성;김영진;김병태
    • 대한핵의학회지
    • /
    • 제32권4호
    • /
    • pp.332-343
    • /
    • 1998
  • 목적 : 폐 FDG PET 동적영상을 분석하는 다양한 분석 방법을 개발하고 표준섭취계수, 패트랙 도표 분석법, 3구획 추적자 역학 모형(5매개변수 모형, 6매개변수 2관심영역 모형)으로 얻은 매개변수 값을 서로 비교, 분석하여 각 분석 방법들의 종양 진단 정확성과 유용성에 대해 고찰하였다. 대상 및 방법 : 22명의 폐종양 환자(9명: 양성 종양 환자(과오종: 1, 활동성 염증: 8), 13명: 악성 종양 환자(기관지 세포암: 5 포함))에게 약 370 MBq (10 mCi)의 FDG를 정맥 주사한 후, GE Advance 양전자방출단층촬영장치를 이용하여 56분 동안 PET 동적영상을 얻은 후, 감쇠보정하여 횡단면 영상을 얻었다. 환자의 몸무게와 혈장 포도당 농도로 규격화된 SUVglu를 계산하였으며, 패트랙 도표 분석법과 3구획 5매개변수 모형과 3구획 6매개변수 2관심영역 모형을 이용하여 FDG 섭취상수($K_{pat},\;K_{5p},\;K_{6p}$)와 당대사율($MR_{pat},\;MR_{5p},\;MR_{6p}$)을 구하였다. 다양한 분석 방법들로 얻은 매개변수들을 수신자판단특성곡선으로 분석하였으며 곡선 아래 면적을 구하였다. 결과: 다양한 분석방법으로 측정한 악성과 양성 병변의 섭취상수와 당대사율은 통계적으로 유의한 차이가 없었다. 각 방법으로 구한 수신자판단특성곡선 아래 면적은 다음과 같다: $SUVglu:\;0.73,\;K_{pat}:\;0.66,\;MR_{pat}:\;0.77,\;K_{5p}:\;0.71,\;MR_{5p},\;0.73,\;K_{6p}:\;0.70,\;MR_{6p}:\;0.78.\;K_{pat} $$MR_{pat}$의 곡선 아래 면적은 통계적으로 유의한 차이를 보였다(p<0.05). 결론: FDG PET 동적영상을 이용한 다양한 추적자 역학 분석 방법을 사용자가 편리하게 사용할 수 있도록 개발하였다. 표준섭취계수, 패트랙 도표 분석법, 3 구획 모형 분석법 둥에 의한 정략적 매개변수의 정확성은 유사헌 것으로 관찰되었다. 추적자 역학 분석 방법으로 얻어진 정량적 매개변수는 객관적 수치정보를 제공하므로써 FDG PET의 유용성을 증가시킬것으로 기대되며, 정량적 매개변수의 임상적 유용성을 밝히기 위해서는 활동성 염증, 과오종이나 기관지 세포암 확률이 낮은 환자군을 대상으로 한 추가 연구가 필요한 것으로 판단된다.

  • PDF

LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구 (A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode)

  • 류찬주
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.891-897
    • /
    • 2021
  • 핵의학은 방사성 동위원소 추적자를 인체에 투여하여 질병의 형태학적 정보와 생물학적 기능 정보를 얻고 평가한 Amyloid PET Tracer 개발로 베타아밀로이드 신경반 확인을 통해서 알츠하이머 진단의 정확도를 높일 수 있다. 그러나 20분이라는 긴 영상획득 시간은 환자에게 힘든 시간 일 수 있다. PET/CT 검사는 환자의 움직임에 민감하며, 검사 결과에도 일부분 영향을 미칠 수 있다. 이에 본 연구에서는 체내 방사성 의약품의 분포를 시간에 따른 list mode acquisition 방법을 통해 영상의 정량적 평가에 영향을 미치지 않으면서 적절한 영상획득 시간 연구하였다. list mode는 기존의 frame mode에 비해 시간에 대한 정보가 포함되어 연구자들이 원하는 시간에 대한 영상을 별도로 reconstruction 할 수 있어 data 분석에 용이하다. 연구 방법은 5 min frame/bed, 10 min frame/bed, 15 min frame/bed, 20 min frame/bed 로 리스트 모드를 이용하여 시간별 재구성 영상을 획득하여 SNR(signal to noise ratio) 과 LPR(lesion-to-pons uptake ratio)의 차이와 판독의 차이를 비교 분석하여 적정한 영상획득시간을 알아보고자 하였다. 정량적 분석 결과 list mode로 측정 시 정량적 평가 결과, 영상획득 시간이 증가함에 따라 관심 영역 6개에서 SUVmean 값은 감소하였으나 5 min/bed 영상에서 가장 많은 차이를 보였고 10 min/bed 그리고 15 min/bed 순으로 SUVmean 값의 차이가 감소하였다. 따라서 15 min/bed 에서의 SUVmean 값은 영상의 평가에 영향을 끼치지 않을 만큼의 차이가 없다는 결과값이 나왔다. LPR 값의 차이는 없었다. 정성적 분석 결과, PET 영상획득시간에 따른 판독 소견의 변화는 없었으며 시간에 따른 영상 재구성의 정성적 분석 점수의 유의한 차이가 없었다. 연구 결과 F-18 fluteme tamol PET/CT 검사 시 15 min/bed 과 20 min/bed 영상이 유의한 차이가 없으므로 환자의 상태에 따라 LIST MODE를 통해 선택적으로 15 min/bed 을 사용하여 영상획득 시간을 줄이는 것이 임상적으로 유용하다고 할 수 있다.