• Title/Summary/Keyword: standardized experimental method

Search Result 104, Processing Time 0.022 seconds

The Relationship Between DEA Model-based Eco-Efficiency and Economic Performance (DEA 모형 기반의 에코효율성과 경제적 성과의 연관성)

  • Kim, Myoung-Jong
    • Journal of Environmental Policy
    • /
    • v.13 no.4
    • /
    • pp.3-49
    • /
    • 2014
  • Growing interest of stakeholders on corporate responsibilities for environment and tightening environmental regulations are highlighting the importance of environmental management more than ever. However, companies' awareness of the importance of environment is still falling behind, and related academic works have not shown consistent conclusions on the relationship between environmental performance and economic performance. One of the reasons is different ways of measuring these two performances. The evaluation scope of economic performance is relatively narrow and the performance can be measured by a unified unit such as price, while the scope of environmental performance is diverse and a wide range of units are used for measuring environmental performances instead of using a single unified unit. Therefore, the results of works can be different depending on the performance indicators selected. In order to resolve this problem, generalized and standardized performance indicators should be developed. In particular, the performance indicators should be able to cover the concepts of both environmental and economic performances because the recent idea of environmental management has expanded to encompass the concept of sustainability. Another reason is that most of the current researches tend to focus on the motive of environmental investments and environmental performance, and do not offer a guideline for an effective implementation strategy for environmental management. For example, a process improvement strategy or a market discrimination strategy can be deployed through comparing the environment competitiveness among the companies in the same or similar industries, so that a virtuous cyclical relationship between environmental and economic performances can be secured. A novel method for measuring eco-efficiency by utilizing Data Envelopment Analysis (DEA), which is able to combine multiple environmental and economic performances, is proposed in this report. Based on the eco-efficiencies, the environmental competitiveness is analyzed and the optimal combination of inputs and outputs are recommended for improving the eco-efficiencies of inefficient firms. Furthermore, the panel analysis is applied to the causal relationship between eco-efficiency and economic performance, and the pooled regression model is used to investigate the relationship between eco-efficiency and economic performance. The four-year eco-efficiencies between 2010 and 2013 of 23 companies are obtained from the DEA analysis; a comparison of efficiencies among 23 companies is carried out in terms of technical efficiency(TE), pure technical efficiency(PTE) and scale efficiency(SE), and then a set of recommendations for optimal combination of inputs and outputs are suggested for the inefficient companies. Furthermore, the experimental results with the panel analysis have demonstrated the causality from eco-efficiency to economic performance. The results of the pooled regression have shown that eco-efficiency positively affect financial perform ances(ROA and ROS) of the companies, as well as firm values(Tobin Q, stock price, and stock returns). This report proposes a novel approach for generating standardized performance indicators obtained from multiple environmental and economic performances, so that it is able to enhance the generality of relevant researches and provide a deep insight into the sustainability of environmental management. Furthermore, using efficiency indicators obtained from the DEA model, the cause of change in eco-efficiency can be investigated and an effective strategy for environmental management can be suggested. Finally, this report can be a motive for environmental management by providing empirical evidence that environmental investments can improve economic performance.

  • PDF

Recipe Standardization and Nutrient Analysis of 'Dong-rae Pajeon' (Local Food in Busan) (부산 향토음식 동래파전의 조리표준화 및 영양분석)

  • Kim, Sang-Ae;Shin, Eun-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.36 no.11
    • /
    • pp.1472-1481
    • /
    • 2007
  • The purposes of the study were to find refined taste of ancestor through historical research about traditional cooking method and ingredient for the purpose of enriching today#s dietary life and to hand down a particular style of regional dish and excellence of nutritional aspect by providing a standard recipe and nutrition analysis data on #Dong-rae Pajeon#. To collect data about traditional ingredients and cooking method, researcher interviewed seven local natives who have kept a traditional food costumes, visited four restaurants, and reviewed ten cookbooks. The interviewees recalled and demonstrated the cooking procedure. The standard recipe of #Dong-rae Pajeon# was created after three experimental cookings, based on the recipes of the natives, restaurants, and cookbooks. According to the natives# statements, #Dong-rae Pajeon# was a special dish that was offered to the king at #Samzi-nal# (March 3rd of the lunar calendar). It was also a seasonal (before cherry blooming time) and memorial service dish of the province#s high society. The main ingredients were small green onion, dropwort, beef, seafood (large clam, mussel, clam meat, oyster, shrimp, fresh water conch), waxy rice powder, non-wax rice powder, and sesame oil which were abundant in Busan and Kijang region. Energy per 100 g of #Dong-rae Pajeon# was 148 kcal. Protein, lipid, fiber, Ca, and Fe contents were 8.8 g, 2.0 g, 8.6 g, 57.7 mg, and 1.8 mg respectively. Contents of cystine, lysine, leucine, valine, isoleucine which are essential amino acids were high in #Dong-rae Pajeon#. Fatty acids contents are oleic acid (20.5%), linoleic acid (20.1%) and linolenic acid (10.4%) while P/M/S ratio was 0.73/0.67/1.

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

Report for Development of Korean Portable Cardiopulmonary Bypass II. Experimental Study of Portable Cardiopulmonary Bypass for Emergency Cardiopulmonary Resuscitation after Cardiac Arrest in Normal Dogs (한국형 이동식 심폐소생기 개발 보고 II. 응급소생술을 위한 이동식 심폐소생기의 동물 실험 연구)

  • Kim, Hyoung-Mook;Lee, In-Sung;Baek, Man-Jong;Sun, Kyung;Kim, Kwang-Taik;Lee, Hye-Won;Lee, Kyu-Back;Chang, Jun-Kuen;Kim, Chong-Won;Kim, Hark-Jei
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1147-1158
    • /
    • 1998
  • Background: Portable cardiopulmonary bypass(CPB) technique has been used increasingly as a potent and effective option for emergency cardiopulmonary resuscitation(CPR) because it can maintain more stable hemodynamics and provide better survival than conventional CPR techniques. This study was designed to develop a prototype of Korean portable CPB system and, by applying it to CPR, to discriminate whether it would be superior to standard open-chest CPR. Material and Method: By using adult mongrel dogs, open-chest CPR(OCPR group, n=4) and portable-CPB CPR(CPB group, n=4) were compared with respects to restoration of spontaneous circulation(ROSC), hemodynamics, effects on blood cells, blood gas patterns, biochemical markers, and survivals. Ventricular fibrillation-cardiac arrest(VF-CA) of arrest(VF-CA) of 4 minutes followed by basic life support(BLS) of 15 minutes was applied in either group, which was standardized by the protocol of American Heart Association. Then, advanced life support(ALS) was applied to either group under the support of internal cardiac massage or CPB. ALS was maintained until ROSC was achieved but not longer than 30 minutes regardless of the presence of ROSC. All of the measured values were expressed as means±SD percent change from baseline. Result: During the early ALS, higher mean arterial pressure was maintained in CPB group than in OCPR group(90±19 vs. 71±32 %; p<.05) and lower mean pulmonary arterial pressure was also maintained in CPB group than in OCPR group(105±24 vs. 146±6%; p<.05). ROSC was achieved in all dogs. Post-ROSC levels of hematocrit, RBC, and platelet were decreased and plasma free hemoglobin was increased significantly in CPB group compared to OCPR group(p<.05). Changes in blood gas patterns, lactate, and CK-MB levels were not different between groups. Early mortality was seen in 3 dogs in OCPR group(survival time 31±36 hours) and 2 in CPB group(228±153 hours, p=ns). The remainders in both groups showed prolonged survival. Conclusion: These findings indicate that portable CPB can be effective to maintain stable hemodynamics during cardiac arrest, to achieve ROSC and to prolong survival. Further study is needed to refine the portable CPB system and to meet clinical challenges.

  • PDF