• Title/Summary/Keyword: standard unit

Search Result 1,831, Processing Time 0.029 seconds

Comparative LCA(life cycle assessment) between two different model of Electric Motor Unit(EMU) (서로다른모델의 전동차에 대한 비교 전과정평가)

  • Kim, Jin-Yong;Choi, Yo-Han;Kim, Young-Ki;Lee, Kun-Mo
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.6-14
    • /
    • 2007
  • The objective of this research is to comparative LCA(life cycle assessment) between two different model of Electric Motor Unit(EMU).the environmental impact of Aluminum body Electric Motor Unit(EMU) and Stainless Steel(STS) body Electric Motor Unit(EMU). LCA process consists of four steps which are goal, scope definition, life cycle impact analysis(LCIA) and life cycle interpretation. ISO 14044 provides the LCA standard method which can be conducted by using comparative LCA. From the research it is foung that the Aluminium Body Electric Motor Unit (EMU) is 3.6ton heaver than Stainless Steel(STS) body Electric Motor Unit(EMU). The system boundary of both Electric Motor Unit (EMU) are same life span and travel same distance. These both Electric Motor Unit (EMU) has same kind of environmental impact which is maximum Ozone Depletion(OD). During using period of these two models, the Aluminium Body Electric Motor Unit(EMU) has more global warming(GW) effect but Stainless Steel(STS) body Electric Motor Unit(EMU) has more Ozone Depletion(OD) effect. The above result is obtained by using LCA software PASS verson 3.1.3.

  • PDF

A Study on Improvement Methods of Cost Estimation in Order for the Proper Management of Street Trees (도시 가로수 관리 품셈 개선에 관한 연구)

  • Do, Yoon-Taek;Han, Bong-Ho;Park, Seok-Cheol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.4
    • /
    • pp.20-36
    • /
    • 2022
  • This study aims to provide basic data for high-quality street tree management by setting reasonable management items and appropriate unit prices by reviewing the adequacy of current street tree management. Currently, street tree management items, except for street tree pruning, use general landscape tree quantity per unit for the street tree management quantity per unit. KEPCO (Korea Electric Power Corporation) applied pruning items from standard electric production infrastructure and carried out the activities at an average unit price of 51% lower for heavy pruning and 39% lower for light pruning than the standard estimate. This was judged to be a level that could not maintain or increase the quality of street tree management. It was determined that an appropriate standard unit price for street tree management was necessary. To improve the quantity per unit for the proper management of street trees, it was necessary to review costs in the field. However, due to the absence of data on actual construction costs in the domestic landscape field, detailed items of the US RSMeans Building Construction Cost Data (RSMeans) were reviewed, and the actual construction costs were calculated by applying personal domestic expenses. As a result, the standard of the estimated unit showed a good ratio of 107% for heavy pruning of street tree pruning compared to the actual construction cost, but light pruning was underestimated with a 59% ratio. Shrub pruning was 82%, weeding was 92%, tree fertilization was 87%, and windbreak wall installation was 91% under-engineered. In addition, it was also confirmed that the watering by sprinkler trucks and chemical spraying were over-designed compared to the actual construction cost at the rates of 118% and 124%, respectively. Due to the specificity of the street trees, the increase in personal expenses and the input cost of equipment, such as road safety controls, were judged to be the main cause of the underestimation of items. Therefore, it is necessary to add items related to street trees and general landscape trees to the landscape maintenance items of the standard of the estimated unit.

Improvement of Lighting Installation Technical Standard in Waterpark, Public Bath and Similar Places for the Prevention of Electric Shock (감전사고 방지를 위한 물놀이.입욕시설의 조명설비 시설기준 개선방안 연구)

  • Kim, Chong-Min;Kim, Han-Sang;Kim, Gi-Hyun;Yi, Geon-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.78-85
    • /
    • 2006
  • A person's body resistance in the waterpark, public bath and similar places is much lower than any other places due to effect of water. So low voltage may create a shock hazard for the human body in case of leakage or fault currents from lighting unit etc. We researched the related regulations which are internal standards, NEC, IEC and investigated the actual conditions for the prevention of electric shock due to lighting units in the waterpark, public bath and similar places. As a results internal standard is obscure as compared with NEC, IEC which is the limit of application and distinction of environment condition. And then internal standard's using voltage is higher than NEC, IEC in filed of water. Studies show that internal standard should be revision that raise the installation height of lighting unit, mark IP level surface of lighting unit and limit using voltage to line-to-line voltage

Evaluation of the Implementation of ISO 11783 for 250 kbps Transmission Rate of Tractor Electronic Control Unit

  • Lee, Dong-Hoon;Lee, Kyou-Seung;Moon, Jae-Min;Park, Seung-Je;Kim, Cheol-Soo;Kim, Myeong-Ho;Cho, Yong-Jin;Kim, Seong-Min
    • Journal of Biosystems Engineering
    • /
    • v.37 no.4
    • /
    • pp.225-232
    • /
    • 2012
  • Purpose: Accurate monitoring of information from various agricultural vehicles is one of the most important factors for appropriate management strategy of field operations. While there has been a number of study and design on applications of sensors and actuators for data acquisition and control system in tractor, incompatibility between various customized hardware and software has become a major obstacle to the universal deployment in real field operation. International standard for implementation of electronic control unit (ECU) in agricultural vehicles has becoming a mandatory requirement for inter-operation compatibility in the international trade of agricultural vehicle industries. The ISO 11783 standard is basically based upon well known communication technology designated using the controller area network (CAN) bus. While CAN bus could provide 1.0 Mbps of communication speed, the standard only recommended 250 kbps. Methods: This study presents the implementation and evaluation of ISO 11783 for tractor electronic control units (TECU)with a higher transmission rate from multiple ECU than 250 kbps. Throughput and loss rate of the developed prototype were calculated across manipulated bus load for laboratory experimental tests, and the maximum requirement of transmission rate by ISO 11873 was satisfied with lower than 60% of bus load. Results: Field tests with a TECU implemented to process messages from global positioning system (GPS) receiver resulted that the root mean square error of position information was lower than 4 m with 0.5 m/s as a travelling speed. Conclusions: Results of this study represent the utilization of the international standard ISO 11783 to providepractical developments in terms with the inter-operability of TECU.

Standard Wire Harness Designs in Commercial Vehicles Based on Control Types and Functional Blocks (동작 방식과 기능별 회로 분류에 기반한 상용차 배선 회로 표준화 방안)

  • Lim, Hansang;Bae, Seung-Deuk;Jung, Do Hwan;Jeong, Hyun Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.4
    • /
    • pp.96-105
    • /
    • 2013
  • This paper presents a standardization method for designing wire harness systems, based on the control types and functional blocks, for use in commercial vehicles. With a rapid increase in the installation of systems with added new features, it is very important to develop a reliable wire harness design in a short time by standardizing wire harness designs and reusing the standard design. Because the function of a system, particularly, for commercial vehicles, varies significantly on the basis of the requirements, regulations, and options, it is not effective to establish one standard design for one system. In addition, a system with the same function may differ in terms of the input conditions and output loads on the basis of the installed vehicle types, and it is not practical to standardize a harness design targeting an entire system. In this study, the wire harness designs of a system were classified into six categories based on the control types of the system: switch driven, control of a switch, control of an electronic control unit, unit driven, control of a unit, and connector operation. Then, a wire harness design of each system was divided into three blocks according to their functions: the control, drive, and monitoring blocks. The standard wire harness designs were made for each functional block of each control type. The advantage of this proposed method is that an effective and practical design can be obtained, which covers the diversities in the same system for different grades of commercial vehicles with a reduction in the number of wire harness supplements.

Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction (조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구)

  • Jeong, Cheol-Ki;Jang, Han;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.

Implementation of Plastic Bottle Classification System for Recycling (분리수거를 위한 페트병 분리시스템의 구현)

  • Park, Yongha;Park, Jihoon;Chung, Hoyeong;Lee, Joosang;Lee, Jungyeop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.365-368
    • /
    • 2021
  • In this study, a plastic bottle recycling bin system that utilizes an infrared sensor was implemented. The proposed system consists of a recognition unit, a control unit, an alarm unit, and a driving unit. The recognition unit detects the plastic bottle, measures the distance between the plastic bottle and the infrared sensor, extracts the value of the bottle, compares the extracted value with a standard range, and then transmits the control value to the control unit if the extracted value of the bottle is outside the standard range. In this case, the result of the presence or absence of a brand label or bottle cap is transmitted to the controller. The control unit opens the entrance of the recycling bin or alerts the alarm unit according to the result value transmitted from the sensor unit. In order to implement the proposed system, the recognition unit was implemented with an infrared sensor, and the control unit was made with an Arduino IDE controller, based on the C programming language. Additionally, the recognition unit and the control unit are able to communicate using analog signals. The proposed system accurately judges the presence or absence of a brand label and bottle cap of plastic bottles according to a predetermined algorithm. It then blocks the entrance of the recycling bin when a brand label or bottle cap is still attached. As the amount of waste discharged per person is relatively high and the majority of such waste is incinerated rather than recycled, the system proposed in this study is expected to increase the recycling rate of plastic bottles.

  • PDF

An integrated approach with homeopathic medicine and electro-acupuncture in anaesthesiology during breast cancer surgery: Case reports

  • Bosco, F;Cidin, S;Maceri, F;Ghilli, M;Roncella, M;De Simone, L
    • Journal of Pharmacopuncture
    • /
    • v.21 no.2
    • /
    • pp.126-131
    • /
    • 2018
  • This study investigates the effect of a combination of homeopathic medicine and electro- acupuncture in two patients with breast cancer and severe liver disease who could not receive standard anaesthesia therapy due to liver problems. Specifically, measurable and quantifiable parameters were used to evaluate whether an integrated approach-consisting of electro- acupuncture and a homeopathic medicine diluted above Avogadro's limit (that is, above a potency of 12CH) during the pre-surgical, surgical and post-surgical phases -can improve general well-being of a patient undergoing breast cancer surgery. In breast cancer surgery, we employed an integrated approach consisting of induction with hypnotics and muscle relaxants, followed by maintenance with anaesthetic gas, combined with a homeopathic treatment (Arnica montana 15CH and Apis mellifica 15CH) before and after surgery and an electro- acupuncture treatment performed in the pre- and post-surgical phases without any analgesic/pain relieving medications. Both of the patients treated with the integrated approach improved their overall condition without need for other common pain relieving medicines. Additionally, thanks to their rapid awakening, the patients were not relocated to a protected area and the hospitalization was shorter. A multidisciplinary approach incorporating homeopathic medicine and electro-acupuncture can be a solution for patients who need or ask about a different and/or safer alternative to the standard treatment. This approach can offer a safe, much less expensive, non-invasive and viable alternative for such cases. Moreover it can be useful for an opioids free anesthesia.

The Classification of Arrhythmia Using Similarity Analysis Between Unit Patterns at ECG Signal (ECG 신호에서 단위패턴간 유사도분석을 이용한 부정맥 분류 알고리즘)

  • Bae, Jung-Hyoun;Lim, Seung-Ju;Kim, Jeong-Ju;Park, Sung-Dae;Kim, Jeong-Do
    • The KIPS Transactions:PartD
    • /
    • v.19D no.1
    • /
    • pp.105-112
    • /
    • 2012
  • Most methods for detecting PVC and APC require the measurement of accurate QRS complex, P wave and T wave. In this study, we propose new algorithm for detecting PVC and APC without using complex parameter and algorithms. Proposed algorithm have wide applicability to abnormal waveform by personal distinction and difference as well as all sorts of normal waveform on ECG. To achieve this, we separate ECG signal into each unit patterns and made a standard unit pattern by just using unit patterns which have normal R-R internal. After that, we detect PVC and APC by using similarity analysis for pattern matching between standard unit pattern and each unit patterns.