• Title/Summary/Keyword: standard test

Search Result 8,553, Processing Time 0.035 seconds

Introduction to the standard reference data of electron energy loss spectra and their database: eel.geri.re.kr

  • Jeong Eun Chae;Ji-Soo Kim;Sang-Yeol Nam;Min Su Kim;Jucheol Park
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.2.1-2.7
    • /
    • 2020
  • Electron energy loss spectroscopy (EELS) is an analytical technique that can provide the structural, physical and chemical information of materials. The EELS spectra can be obtained by combining with TEM at sub-nanometer spatial resolution. However, EELS spectral information can't be obtained easily because in order to interpret EELS spectra, we need to refer to and/or compare many reference data with each other. And in addition to that, we should consider the different experimental variables used to produce each data. Therefore, reliable and easily interpretable EELS standard reference data are needed. Our Electron Energy Loss Data Center (EELDC) has been designated as National Standard Electron Energy Loss Data Center No. 34 to develop EELS standard reference (SR) data and to play a role in dissemination and diffusion of the SR data to users. EELDC has developed and collected EEL SR data for the materials required by major industries and has a total of 82 EEL SR data. Also, we have created an online platform that provides a one-stop-place to help users interpret quickly EELS spectra and get various spectral information. In this paper, we introduce EEL SR data, the homepage of EELDC and how to use them.

Validation of Suitability on Proficiency Testing Samples for Acute Toxicity Test with Daphnia magna (생태독성 숙련도 시료의 적절성 평가)

  • Shin, Kisik;Park, Woosang;Lee, Jungseo;Yu, Soonju;Park, Taejin;Kim, Jongmin
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.1
    • /
    • pp.49-54
    • /
    • 2015
  • Acute toxicity test with Daphnia magna has a variety of factors such as incubation condition of test species, food quality and proficiency of laboratory workers. Therefore, proper proficiency testing samples were required for evaluating the competence of laboratory workers. This study aims to propose some appropriate proficiency testing samples for laboratory workers of acute toxicity test with Daphnia magna. Proposed four kinds of standard samples (Sample A, B, C, and D) for proficiency testing were selected from reference materials which were recommended from Canada and USA WET(Whole Effluent Toxicity) authorities. Proposed standard samples were tested by trial application of proficiency testing, homogeneity and stability checks using repeatability test. Sample A, C and D were estimated ad the suitable candidates for proficiency test standard samples except for Sample B. In addition, Sample A was proved to be the most suitable sample.

A new method fast measure cryogenic vessel heat leakage

  • LI, Zheng-Qing;LI, Xiao-Jin;LIU, Mo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.1
    • /
    • pp.24-28
    • /
    • 2020
  • Heat leakage is an important parameter to reflect heat insulated performance of cryogenic vessel. According to the current standard requirements, it needs to measure the daily evaporation rate to indicate heat leakage. The test needs-over 24h after cryogenic vessel in heat equilibrium as standard required, therefore test efficiency is poor and new efficient method is required to cut test time. First of all, the volume of instantaneous evaporated gas and heat leakage are calculated by the current standard corresponding to the maximum allowable daily evaporation rate of cryogenic vessel. Depending on the relationship between real daily evaporation rate and maximum allowable daily evaporation rate of cryogenic vessel, we designed a new test method based on the pressure changes over time in cryogenic vessel to determine whether its heat insulated performance meets requirements or not. Secondly, the heat transfer process was analyzed in measurement of cryogenic vessel, and the heat transfer equations of whole system were established. Finally, the test was completed in four hours; meanwhile the heat leakage and daily evaporation rate of cryogenic vessel are calculated basing on test data.

Properties Evaluation on Aluminum for Die-casting(ADC 12) to Packing Case of Composite Sensor (복합센서 케이스용 알루미늄 다이캐스팅(ADC 12) 합금의 특성평가)

  • Son, Jae-Hwan;Oh, Sang-Kyun;Kim, Dong-Bae;Han, Chang-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.2
    • /
    • pp.141-145
    • /
    • 2006
  • In case of sense case manufactured by method of outage capacity, sensitivity is declined by outside effect and method of the photo electricity has a problem in transmission. therefore, packing case of composite sense should be developed to improve such a problem about influence of outside environment and its property evaluation has been performed. Mechanical property and result of analysis & test evaluation of Mat'l on aluminum die-casting(ADC 12type) Mat'l developed are as following. Tensile test piece, No. 4 of KS B 0801, has been applied to mechanical property test of Mat'l and It has been tested by method of metal mat'l tensile test(KS B 0802 : 2003). It can be found that physical property to KS(Korea Standard) is excellent. and homogeneous mechanical property appears. Test of Mat'l analysis has been performed by using OE Spectrometer, according to ASTM E 1251 : 1994 regulation. Consequently, good and homogeneous component contents classified by element to standard, except for Fe, have been obtained with coordination of Fe content as below 1.3% from composition standard of Aluminum Die-casting.

  • PDF

The International Standard Trends of MV Power Cable Installation Test and its Application on Korean Standard (지중배전케이블 준공시험 관련 국제규격 동향과 국내기준 개선 방안)

  • Lee, Jae-Bong;Jung, Yeon-Ha;Song, Il-Keun;Cho, Soung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1933-1937
    • /
    • 2008
  • XLPE insulated power cables are introduced in Korea in 1980s. The cable installation test has been carried out according to the Korean Technical Reference of Electrical Facilities. But recent research results shows DC Hipot test cannot detect the serious defects in XLPE insulated cables. VLF test is recommended as a installation test of XLPE insulated cables by CENELEC and IEEE standards in 1996 and 2001 respectively. We suggest to apply VLF test as an installation test for XLPE insulated MV cables in Korea.

Estimation of Liquid Limit by a Single-point Method of Fall Cone Test (Fall Cone Test의 일점법을 이용한 액성한계 추정)

  • Son, Young-Hwan;Chang, Pyoung-Wuck;Won, Jung-Yun;Kim, Seong-Pil
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.203-206
    • /
    • 2003
  • The liquid limit(LL) test is universally used as a standard test for determining one of the index properties of a clay. There are two methods of determining the LL, Casagrande method and cone penetration method that is fall cone test. The interpretation of the Casagrande method of obtaining the LL is not obvious, but it has been suggested that the fall cone test is essentially a strength test and that the LL test simply ascertains the moisture content at which a clay has a certain standard undrained shear strength. This paper presents a determination of the LL by a single-point method. Results obtained from fall cone that is general method and a single-point method are analyzed by comparison.

  • PDF

A Study on the Evaluation of Measurement Uncertainty for the National Calibration and Test Organizations (Liquid Flow) (국가교정검사기관(액체유량)의 측정불확도 평가 및 비교연구)

  • 임기원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.1012-1019
    • /
    • 2000
  • A proficiency test is one of programs which Korea Research Institute of Standards and Science(KRISS), as national metrology institute, is putting in operation for the mutual recognition arrangement. The Fluid Flow Group of KRISS evaluated the measurement capability for liquid flowmeter calibrator of the national calibration and test organizations. The uncertainty of national standard system was estimated in accordance with Guide to The Expression of Uncertainty in Measurement (ISO), and the turbine flowmeter, which was used for the round-robin test as a reference flowmeter, was characterized. The round-robin tests with the turbine flowmeter package were carried out in 1995 and 1999. The test results of the organizations and those of KRISS agreed within $\pm0.2$%. It is found thus that the organizations have the traceability of the national standard for liquid flow measurement.

  • PDF

Delay Test for Boundary-Scan based Architectures (경계면 스캔 기저 구조를 위한 지연시험)

  • 강병욱;안광선
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.6
    • /
    • pp.199-208
    • /
    • 1994
  • This paper proposes a delay fault test technique for ICs and PCBs with the boundary-scan architectures supporting ANSI/IEEE Std 1149.1-1990. The hybrid delay fault model, which comprises both of gate delay faults and path delay faults, is selected. We developed a procedure for testing delay faults in the circuits with typical boundary scan cells supporting the standard. Analyzing it,we concluded that it is impractical because the test clock must be 2.5 times faster than the system clock with the cell architect-ures following up the state transition of the TAP controller and test instruction set. We modified the boundary-scan cell and developed test instructions and the test procedure. The modified cell and the procedure need test clock two times slower than the system clock and support the ANSI/IEEE standard perfectly. A 4-bit ALU is selected for the circuits under test. and delay tests are simulated by the SILOS simulator. The simulation results ascertain the accurate operation and effectiveeness of the modified mechanism.

  • PDF

Study of Vibration Test Condition for Machinery Component (기계류부품의 가진시험 조건에 관한 연구)

  • Kim Hyoung-Eui;Park Jong-Won;Jung Dong-Soo;Kang Bo-Sik
    • Journal of Applied Reliability
    • /
    • v.6 no.1
    • /
    • pp.27-36
    • /
    • 2006
  • It is increasingly important to ensure that a given vibration test specification of a particular machinery component is appropriately established by considering its real environmental conditions. Vibration test standards for electrical components are well documented, for example in an IEC 60068 series, while standards for machinery components are rarely found except a few military standards. Thus many vibration tests are performed based on the military standards. However, a test based on these military standards often results in over-testing, and under-testing in some cases due to the different environmental conditions. Also, these standards require an appropriate tailoring that may not be easily accomplished. In this paper, various international and military standards are compared and investigated to obtain test specifications relevant for machinery components. Also appropriate tailoring methods are demonstrated through a case study.

  • PDF

Comparison and Analysis between the simulation and test result for Quality Assessment of Surge Protective Insulating Transformer. (서지방호용 절연변압기 성능시험관련 모의해석 및 시험결과와의 비교분석)

  • Choi Young-Ha;Kim Myung-Young;Lee Kang-Won;Ohn Jung-Ghun;Song Joong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.519-522
    • /
    • 2003
  • 'KRS 6330-3256라' standard regulates performance test of insulating transformer for protecting the electronic interlock linkage equipment which is being done by test procedures and methods according to the standard. The balance/unbalance test evaluating the performance of transformer are applied by impulse voltage($l2/200{\mu}s$) but affected by many other factors. Therefore, the review about these is necessary to have the reliability and reappearance of test results. In this paper, we have simulated about several phenomenon appearing in real balance/unbalance test and compared simulated results with real ones. With the basis of these results, the influence to test result of inner and outer factors are investigated and analyzed and established the plan boosting the reliability and reappearance of test results.

  • PDF