• Title/Summary/Keyword: standard set

Search Result 2,555, Processing Time 0.033 seconds

Selection and implementation of Standard Functional Blocks for Radio Library in multi-mode mobile device (멀티모드 단말기의 라디오 라이브러리를 위한 표준 기능 블록의 선정 및 구현)

  • Jung, Ildo;Choi, Sengwon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.3
    • /
    • pp.125-132
    • /
    • 2016
  • The European Telecommunication Standards Institute (ETSI) Technical Committee (TC) Reconfigurable Radio Systems (RRS) is standardizing the multi-mode Mobile Device (MD). The configuration of multi-mode MD is determined by the downloaded mobile communication standard software. In this paper, we introduce the Radio Library concept for multi-mode MD which is one of the key components of RRS standard. This paper also introduces the Standard Functional Block which is a part of Radio Library. A method for selecting efficiency SFBs for multi-mode MD is presented and a Radio Library is generated based on the selected SFBs. This paper also shows sample Standard Functional Block Set which included in Radio Library. In order to verify the compatibility of the generated Radio Library which was made by C language, we implement the LTE Rel-10 and Wi-Fi(802.11b) to show the efficiency of generating a mobile communication standard software based on the Radio Library. Then using the Prograph Visual Programming MartenTM 1.6.4, we compiled our LTE Rel-10 and Wi-Fi(802.11b) source code.

A study on the Assessment of Standard Wages for Constructing Luminaries for Landscope Lighting (경관조명기구의 설치에 대한 기준노임 산정에 관한 연구)

  • Yoo, Dong-Gil;Lee, Bok-Hee;Lee, Sok-Yeon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.169-172
    • /
    • 2008
  • Recently, landscape lighting is more and more installing in many places such as park, cultural heritages, large-scale structures, bridges, apartment, and so on. However, there is no the government-set official estimation for standard wages constructing luminaries for landscape lighting. The cost of construction is estimated based on the standard wages of related-similar installations such as internal lighting fixtures or the designer's subjective decision. Sometimes, it is overestimated or underestimated. In this paper, the fundamental process for estimating the standard wages constructing luminaries for landscape lighting is studied. The estimation method of standard wages constructing lighting fixtures was examined on the basis of the type and capacities of luminaries, installation places, type and shapes of installation auxiliary materials, worker's skill, and etc. As a result, some results obtained in this work were significantly, different with the standard wages for internal electric wiring published by Korea Electric Association. In the future, to improve the accuracy of the estimation of the standard wages for constructing luminaries for landscope lighting, detailed factors related to the installation condition and dimensions and types of luminaries should be considered.

  • PDF

Setup of standard PD calibrator and its uncertainties

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.677-683
    • /
    • 2011
  • The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory. Using this software, averages of charges and rising times and their standard deviations in the measured pulses can also be calculated. The standard PD calibrator generates five types of pulses: single, double, random, oscillating, and long-rising. The coefficient sensitivities to estimate the uncertainties of pulses were extracted in the model circuit of the standard PD calibrator. The uncertainties of charges and rising times in pulses of the standard PD calibrator were estimated with single pulses. These values were 0.3%-1.4% in charges and 1.9%-7.0% in rising time; however, these values are lower than the limit values in IEC 60270.

An Analysis of Performance Error of High Precision Measuring Instrument (진원도 측정기의 오차특성에 관한 연구)

  • 한응교;노병옥;허민석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.862-874
    • /
    • 1989
  • A phase evil method and spectrum analysis were instrument error which is originated from measurement system and the form error of standard specimens. An instrument with a rotating table supported by an air bearing is calibrated using standard specimens. The phase of standard specimens was measured 12 times on the rotating table with rotating 30 in turn and its measurement magnification was set by 100000 times. As a result of data analysis of all the observations, read out at each of 144 orientations(per 2.5) from recorded datafiles, the error of the performance of the instrument and those of the standard specimens are evaluated and a systematic deviation of the instrument is determined. In the particular instrument used in the present experiment, the deviation of the instrument is determined with the accuracy of 15nm and those of standard specimens with the accuracy of 23, 13 n, respectively. The reproducibility of the instrument is investigated, too. If the instrument is calibrated by using the above standard specimens, then the accuracy of the measurement of roundness error can be improved to about 15nm.

Improving Stability of Motor Generator Set of the Power Supply System for CEDM in Korean Standard Nuclear Power Plants (한국표준형 원전 제어봉구동장치 전원공급계통의 전동발전기 세트 안정성 개선)

  • Choi, Il Young;Kim, Jin Weon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.49-55
    • /
    • 2016
  • This paper analyzed a root cause of abnormality in the temperature and vibration at generator-side bearing of motor generator set (MG Set), which is a power supply system to control element drive mechanism (CEDM) of nuclear power plants (NPPs), and modified the design of roller-type and sealing method to improve the abnormalities. From the inspection of MG Set and analysis of temperature variation during service, it was found that the abnormal temperature transition was basically associated with original design of generator-side bearing, whose roller was axially restrained by inner race, and that the abnormal vibration level was caused by inserting small chips of cage and V-ring, which were generated due to the abnormal temperature transition at roller bearing. Type of bearing and sealing method were modified based on these analyses. The temperature and vibration level measured at roller bearing showed that the modifications clearly improved the operational stability of MG Set.

Design of Compatible Set-Top Box for Healthcare (헬스케어를 위한 호환 가능한 셋톱박스 설계)

  • Han, Jung-Soo
    • Journal of Digital Convergence
    • /
    • v.12 no.7
    • /
    • pp.285-290
    • /
    • 2014
  • In these days the patient can be easy to see the treatment results at home without going directly to hospital. Despite the many advantages that the patient is got optimum service timely, the currently used personal healthcare devices have no compatibility because the manufacturer use the proprietary software and hardware protocols. For these issues, standardization is required between the set-top box and the individual healthcare devices. In this paper, we designed the healthcare set-top box possible to biometric data transmission by using a standard IEEE P11073 between the device and the set-top box. Because the set-top box using IEEE P11073 standardization can transfer data independently, we are expected to make it contribute significantly to the healthcare business.

A Research on Standard Dimensions for Fresh Cut Flower Packages (절화류의 포장규격에 관한 연구)

  • Ha, Young-Sun;Kim, Jong-Kyoung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.12 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Increasement of total cost during distribution chain requires packaging standardization to reduce extra handling and delays at transshipment point. In Korea, high valued agricultural products to export are most often shipped by air freight. Fresh flowers, in particular, the need to set package standard for air palletization are strongly recommended. This study tried to find an optimum standard dimensions for export packages. After extensive research on combinations of various flower dimensions, package dimensions and pallet sizes, we found that 96 inches pallet was most adequate for international air freight. Based on the results, new 40 standard package dimensions were introduced and stacking efficiencies were calculated.

  • PDF

The Effects of Seat Surface Inclination on the Onset of Muscle Contraction during Sit-to-stand in Healthy Adults

  • Shin, Hwa-Kyung;Ryu, Young-Uk
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.6
    • /
    • pp.383-387
    • /
    • 2012
  • Purpose: Rising from a chair is important for activities of daily living. Several factors have influence on sit-to-stand movement. We studied the effect of inclination of seat surface of on the movement of rising from a chair with electromyographic (EMG). Methods: Twelve subjects performed the sit-to-stand movement on anterior-inclined, standard, and posterior inclined chair. We measured onset time of tibialis anterior and rectus femoris with EMG on each inclination chair. Results: The onset time at the anterior-inclined chair is significantly faster than it at the standard chair (p<0.05). And the onset time at the posterior-inclined chair is significantly slower than it at the standard chair (p<0.05). Conclusion: Rising from anterior inclined chair appeared to be more effective than rising from the standard and posterior inclined chair. Therefore, this finding suggests that the selection of set surface inclination must be considered for activities of daily living during rehabilitation.

ON FRAMES FOR COUNTABLY GENERATED HILBERT MODULES OVER LOCALLY C*-ALGEBRAS

  • Alizadeh, Leila;Hassani, Mahmoud
    • Communications of the Korean Mathematical Society
    • /
    • v.33 no.2
    • /
    • pp.527-533
    • /
    • 2018
  • Let $\mathcal{X}$ be a countably generated Hilbert module over a locally $C^*$-algebra $\mathcal{A}$ in multiplier module M($\mathcal{X}$) of $\mathcal{X}$. We propose the necessary and sufficient condition such that a sequence $\{h_n:n{{\in}}\mathbb{N}\}$ in M($\mathcal{X}$) is a standard frame of multipliers in $\mathcal{X}$. We also show that if T in $b(L_{\mathcal{A}}(\mathcal{X}))$, the space of bounded maps in set of all adjointable maps on $\mathcal{X}$, is surjective and $\{h_n:n{{\in}}\mathbb{N}\}$ is a standard frame of multipliers in $\mathcal{X}$, then $\{T{\circ}h_n:n{\in}\mathbb{N}}$ is a standard frame of multipliers in $\mathcal{X}$, too.

Development and its Validation of Sky Simulator Facilities for Daylighting Evaluation (자연채광 성능평가용 인공천공돔(Sky Simulator)의 개발 및 신뢰성 검증)

  • Kim, Jeong-Tai;Kim, Gon;Yu, In-Hye
    • KIEAE Journal
    • /
    • v.5 no.4
    • /
    • pp.51-57
    • /
    • 2005
  • For the evaluating daylighting performance, field measurement, scale model test and a set of computer tools can be applied. For the scale model measurements, the sky simulator is a vital facility to represent the desired sky conditions consistently. Recently K university has developed a large size sky simulator, 6m-diameter and 3.7m-height, that is suitable for the international standard. To verify the reliability of the sky simulator, the luminance distribution on the inner sky surface was measured and compared with the CIE standard overcast sky model. It is found that the sky simulator can be reproduced the CIE standard overcast sky condition with 4.3% as mean difference. K university sky simulator is fully validated for usability and accuracy for daylighting researches.