• Title/Summary/Keyword: standard reference materials

Search Result 355, Processing Time 0.029 seconds

Vitamin B5 and B6 Contents in Fresh Materials and after Parboiling Treatment in Harvested Vegetables (채소류의 수확 후 원재료 및 데침 처리에 의한 비타민 B5 및 B6 함량 변화)

  • Kim, Gi-Ppeum;Ahn, Kyung-Geun;Kim, Gyeong-Ha;Hwang, Young-Sun;Kang, In-Kyu;Choi, Youngmin;Kim, Haeng-Ran;Choung, Myoung-Gun
    • Horticultural Science & Technology
    • /
    • v.34 no.1
    • /
    • pp.172-182
    • /
    • 2016
  • This study was aimed to determine the changes in vitamin $B_5$ and $B_6$ contents compared to fresh materials after parboiling treatment of the main vegetables consumed in Korea. The specificity of accuracy and precision for vitamin $B_5$ and $B_6$ analysis method were validated using high-performance liquid chromatography (HPLC). The recovery rate of standard reference material (SRM) was excellent, and all analysis was under the control line based on the quality control chart for vitamin $B_5$ and $B_6$. The Z-score for vitamin $B_6$ in food analysis performance assessment scheme (FAPAS) proficiency test was -1.0, confirming reliability of analytical performance. The vitamin $B_5$ and $B_6$ contents in a total of 39 fresh materials and parboiled samples were analyzed. The contents of vitamin $B_5$ and $B_6$ ranged from 0.000 to 2.462 and from 0.000 to $0.127mg{\cdot}100g^{-1}$, respectively. The highest contents of vitamin $B_5$ and $B_6$ were $2.462mg{\cdot}100g^{-1}$ in fresh fatsia shoots (stem vegetables), and $0.127mg{\cdot}100g^{-1}$ in fresh spinach beet (leafy vegetables), respectively. Moreover, the vitamin $B_5$ and $B_6$ contents for parboiling treatment in most vegetables were reduced or not detected. In particular, the contents of vitamin $B_5$ in parboiled fatsia shoots and vitamin $B_6$ in parboiled yellow potato and spinach beet were decreased 20- and 4-fold compared with fresh material, respectively. These results can be used as important basic data for utilization and processing of various vegetable crops, information for dietary life, management of school meals, and national health for Koreans.

Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height (구내 스캔바디의 형태에 따른 임플란트의 디지털 스캔 정확도 및 구강 내 노출 높이에 따른 라이브러리 중첩 정확도 비교 연구)

  • Jeong, Byungjoon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • Purpose: The purpose of this study is to compare the accuracy of digital scans of implants according to different shapes of scanbodies, and to compare the accuracy of library merging according to different oral exposure height. Materials and methods: A master model with a single tooth edentulous site was prepared. For the first experiment, three types of intraoral scanbodies were prepared, divided into three groups, and the following experiments were conducted for each group: An internal hex implant was placed. The master model with the scanbody connected was scanned with a model scanner, and a master reference file (control group) was created. 10 files (experimental group) were created by performing 10 consecutive scans with an intraoral scanner. After superimposing the control and experimental groups, the following values were calculated: 1) Distance deviation of a designated point on the scanbody 2) Angle deviation of the major axis of the scanbody. For the second experiment, the scanbody scan data were prepared in 6 different heights. Library files were merged with each of the scan data. The distance and angular deviation were calculated using the 7 mm scan data as control group. Results: In the first experiment, there were no significant differences between A and B (P=.278), B and C (P=.568), and C and A (P=.711) in the distance deviations. There were no significant differences between A and B (P=.568), B and C (P=.546), and C and A (P=.112) in the angular deviations. Also, the scanbody showed significantly higher library merging accuracy in the groups with high oral exposure height (P<.5). Conclusion: There were no significant differences in scan accuracy according to the different shapes of scanbodies, and the accuracy of library merging increased according to exposure height of the scanbody in the oral cavity.

Comparison of Dissolved Ammonium Analytical Method in Seawater: Spetrophotometry and Fluorometry (해수 중 용존 암모늄 분석방법 비교: 분광광도법과 형광법)

  • SON, PURENA;PARK, JOONSEONG;RHO, TAEKEUN
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.25 no.4
    • /
    • pp.81-96
    • /
    • 2020
  • Berthlot's reaction spectrophotometric method is generally used for the analysis of dissolved ammonium in seawater, but in recent years, a fluorescence method using an orthophthaldialdehyde-sulfite (OPA) fluorescent reagent is actively used internationally. In this study, we investigated the effects of the detection limit between the analysis methods, the reagent refractive index inherent in the spectrophotometric method, and the use of different calibration curves to understand the cause of the difference in dissolved ammonium concentration (about 0.31 𝜇M) observed in the seawater samples and a nutrient reference material between two institutions (KIOST (spectrophotometric method, one-order linear regression gradient only), Australia CSIRO (fluorescence method, quadratic formula)) conducted onboard the Australian R/V Investigator in 2017. The method detection limit (0.063 𝜇M) and the reagent refractive index background value (0.054 𝜇M) of the spectrophotometric method measured in this study could explain the difference in dissolved ammonium concentration values of the two institutes about 20% and 17%, respectively. However, when the concentration of the calibration curve of the spectrophotometric method was calculated using the same quadratic as the fluorescence method or the slope and intercept of linear regression, the difference in the dissolved ammonium concentration between the two institutions was reduced to less than the detection limit of the spectrophotometric method. Therefore, the difference in the concentration of dissolved ammonium between the two institutions, found in the nutrient reference materials and the seawater field sample during the international onboard nutrient inter-comparison experiment, may be attributed to be the effect of the different calibration curves used in the two methods rather than the effect of the difference in two analytical methods. When comparing the dissolved ammonium data from seawater samples in the future, it is recommended to pay attention to the information on the baseline, number of standard solutions, and calibration curve used in the analysis.

Establishment of Biotin Analysis by LC-MS/MS Method in Infant Milk Formulas (LC-MS/MS를 이용한 조제유류 중 비오틴 함량 분석법 연구)

  • Shin, Yong Woon;Lee, Hwa Jung;Ham, Hyeon Suk;Shin, Sung Cheol;Kang, Yoon Jung;Hwang, Kyung Mi;Kwon, Yong Kwan;Seo, Il Won;Oh, Jae Myoung;Koo, Yong Eui
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.327-334
    • /
    • 2016
  • This study was conducted to establish the standard method for the contents of biotin in milk formulas. To optimize the method, we compared several conditions for liquid extraction, purification and instrumental measurement using spiked samples and certified reference material (NIST SRM 1849a) as test materials. LC-MS/MS method for biotin was established using $C_{18}$ column and binary gradient 0.1% formic acid/acetonitrile, 0.1% formic acid/water mobile phase is applied for biotin. Product-ion traces at m/z 245.1 ${\rightarrow}$ 227.1, 166.1 are used for quantitative analysis of biotin. The linearity was over $R^2=0.999$ in range of $5{\sim}60{\mu}g/L$. For purification, chloroform was used as a solvent for eliminating lipids in milk formula. The linearity was over 0.999 in range of 5~60 ng/mL. The detection limit and quantification limit were 0.10, 0.31 ng/mL. The accuracy and precision of LC-MS/MS method using CRM were 103%, 2.5% respectively. Optimized methods were applied in sample analysis to verify the reliability. All the tested milk formulas were acceptable contents of biotin compared with component specification and standards for nutrition labeling. The standard operating procedures were prepared for biotin to provide experimental information and to strengthen the management of nutrient in milk formula.

A Study about Development of Environment Printing Technology and $CO_2$ (환경 인쇄 기술의 발전과 인쇄물의 $CO_2$ 발생량에 관한 연구)

  • Lee, Mun-Hag
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.30 no.3
    • /
    • pp.89-114
    • /
    • 2012
  • For as to world, the concern about the environment problem is enhanced than any other time in the past because of being 21 century. And the environment problem is highlighted as the world-wide issue. The time of the environment problem intimidates the alive of the mankind and presence of an earth over the time. It becomes the essentiality not being selection in the personal living or the economical viewpoint now to prepare for the climatic modification. As to the company management, the green growth period which it excludes the environment management considering an environment, cannot carry on the company the continued management comes. That is, in the change center of the management paradigm, there is the environment management. Nearly, the greenhouse gas which the publication industry is the environmental toxic material like all industries is generated. The greenhouse gas is ejected in the process of running the manufacturing process and print shop of the various kinds material used as the raw material of the book. Particularly, the tree felling for getting the material of the paper is known to reach the direct influence on the global warming. This study does according to an object it considers and organizes the environment parameter based on this kind of fact as to the publication industry. And it is determined as the reference which is used as the basic materials preparing the case that carbon exhaust right transaction(CAP and TRADE) drawing are enforced in all industries and is sustainable the management of the publication industry and reduces the environmental risk among the company many risk management elements and plans and enforces the publication related policy that there is a value. In the printing publication industry, this study tried to inquire into elements discharging the environmental pollutant or the greenhouse gas. Additionally, in the printed publication production process, it tried to inquire into the effort for an environment-friendly and necessity at the printing paper and the printers ink, regarded as the element discharging the greenhouse gas all kinds of the printing materials, operation of the print shop and all kinds of the machines and recycle process, and etc. These considerations make these industrial field employees aware of the significance about a conservation and environmental protection. They try to give a help in the subsequent study producing quantitatively each environmental parameter emission of green house gas. This makes the calculation of the relative $CO_2$ output reproached ultimately possible. Meanwhile, in a sense, many research protects and improving an environment in connection with the contents of research at the printing publication industrial field is in progress. There will be the voluntary human face that it has to protect an environment but this can not do by the outside factor according to all kinds of environment related law and regulation. Anyway, because of acting on company management as the factor of oppression, the increase of this environment-related correspondence cost could know that the research that the environment loading relates with a procurement and development, environment management system introduction, quality control standard, including, normalizing including a material, and etc. through the part of the effort to reduce the cost low was actively in progress. As to the green growth era, as follows, this paper prescribed the subject and alternative of the print publication industry. It is surrounded by the firstly new digital environment and the generation of the subject. And secondly the printing industry is caused by the point of time when the green growth leaves by the topic which is largest in the global industry and it increases. The printing publication industry has to prepare the bridgehead for the environment-friendly green growth as the alternative for this resolution with first. The support blown in each industry becomes the obligation not being selection. Prestek in which the print publishing was exposed to spend many energies and which is known as the practice of the sustainable print publishing insisted that it mentioned importance of the green printing through the white pages in 2008 and a company had to be the green growth comprised through the environment-friendly activity. The core management for the sustainable printing publication industry presented from Presstack white pages is compacted to 4 words that it is a remove, reduce, recover, and recycle. Second, positively the digital printing(POD) system should be utilized. In the worldwide print out market, the digital printing area stops at the level of 10% or so but the change over and growth of the market of an analog-to-digital will increase rapidly in the future. As to the CEO Jeff Hayes of the Infoland, the offset print referred to that it of the traditional method got old and infirm with the minor phase of the new printing application like the customer to be wanted publication and the print of the digital method led the market. In conclusion, print publishers have to grasp well the market flow in the situation where a digitalization cannot be generalized and a support cannot avoid. And it keeps pace with the flow of the digital age and the recognition about the effort for the development and environment problem have to be raised. Particularly, the active green strategy is employed for the active green strategy.

Measurement of Environmental Radiation Using Medical Scintillation Detector in Well Counter System (의료용 우물형 섬광계수기를 이용한 환경 방사선 측정)

  • Lyu, Kwang Yeul;Park, Yeon-joon;Kim, Min-jeong;Ham, Eun-hye;Yoon, Ji-yeol;Kim, Hyun-jin;Min, Jung Hwan;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.337-345
    • /
    • 2015
  • After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with 'Captus-3000 thyroid uptake measurement systems' in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system's sensitivity. Then we compared the results of each material's cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like 'High purity germanium radiation detector'. Moreover, We didn't have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material's spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material's cpm with BKG, we've compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A, alkaline battery showed higher rate of radiation by 7.67 %, and Button type battery was yield 4.65 % higher rate than BKG. Additionally, Asphalt (8.03 %), Topsoil (3.76 %), Briquette (7.46 %) were yield for higher values. Several samples of the daily supplies were yield little higher, but it seems safe to use in daily lives. In the case of the 'Foodstuff', all of the samples were safe and they were under the radiation limits of the Ministry of Food and Drug Safety for Food; thus, we highly recommend this study to you as a reference of common daily routine.

Evaluation of Multiple System Atrophy and Early Parkinson's Disease Using $^{123)I$-FP-CIT SPECT ($^{123)I$-FP-CIT SPECT를 이용한 다중계위축증 및 조기 파킨슨병에서의 평가)

  • Oh, So-Won;Kim, Yu-Kyeong;Lee, Byung-Chul;Kim, Bom-Sahn;Kim, Ji-Sun;Kim, Jong-Min;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.10-18
    • /
    • 2009
  • Purpose: We investigated quantification of dopaminergic transporter (DAT) and serotonergic transporter (SERT) on $^{123}I$-FP-CIT SPECT for differentiating between multiple systemic atrophy (MSA) and idiopathic Parkinson's disease (IPD). Materials and Methods: N-fluoropropyl-$2{\beta}$-carbomethoxy-$3{\beta}$-4-[$^{123}I$]-iodophenylnortropane SPECT ($^{123}I$-FP-CIT SPECT) was performed in 8 patients with MSA (mean age: $64.0{\pm}4.5yrs$, m:f=6:2), 13 with early IPD (mean age: $65.5{\pm}5.3yrs$, m:f=9:4), and 12 healthy controls (mean age: $63.3{\pm}5.7yrs$, m:f=8:4). Standard regions of interests (ROls) of striatum to evaluate DAT, and hypothalamus and midbrain for SERT were drawn on standard template images and applied to each image taken 4 hours after radiotracer injection. Striatal specific binding for DAT and hypothalamic and midbrain specific binding for SERT were calculated using region/reference ratio based on the transient equilibrium method. Group differences were tested using ANOVA with the postHoc analysis. Results: DAT in the whole striatum and striatal subregions were significantly decreased in both patient groups with MSA and early IPD, compared with healthy control (p<0.05 in all). In early IPD, a significant increase in the uptake ratio in anterior and posterior putamen and a trend of increase in caudate to putamen ratio was observed. In MSA, the decrease of DAT was accompanied with no difference in the striatal uptake pattern compared with healthy controls. Regarding the brain regions where $^{123}I$-FP-CIT binding was predominant by SERT, MSA patients showed a decrease in the binding of $^{123}I$-FP-CIT in the pons compared with controls as well as early IPD patients (MSA: $0.22{\pm}0.1$ healthy controls: $0.33{\pm}0.19$, IPD: $0.29{\pm}0.19$), however, it did not reach the statistical significance. Conclusion: In this study, the differential patterns in the reduction of DAT in the striatum and the reduction of pontine $^{123}I$-FP-CIT binding predominant by SERT could be observed in MSA patients on $^{123}I$-FP-CIT SPECT. We suggest that the quantification of SERT as well as DAT using $^{123}I$-FP-CIT SPECT is helpful to differentiate parkinsonian disorders in early stage.

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.

Contrast-Enhanced Magnetic Resonance Angiography for Evaluation of the Steno-occlusive Disease of the Supraaortic Arteries: Comparison with Computed Tomography Angiography and Digital Subtraction Angiography (조영증강 자기공명 혈관조영술을 이용한 대동맥궁 위 혈관의 협착 및 페쇄 질환 평가: 전산화 단층 혈관조영술 및 디지털 감산혈관조영술과의 비교)

  • Jeh, Su-Kyung;Kim, Bum-Soo;Jung, So-Lyung;Ahn, Kook-Jin;Shin, Yong-Sam;Lee, Kwan-Sung;Kim, Young-In;Lee, Kwang-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.152-160
    • /
    • 2009
  • Purpose : To intra-individually compare diagnostic accuracy of high-resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with computed tomography angiography (CTA) and digital subtraction angiography (DSA) for the assessment of supraaortic steno-occlusive disease. Materials and Methods : Twenty-eight patients (20 men, 8 women, 53-79 years of age) underwent supraaortic CE-MRA, CTA and DSA. CE-MRA was performed on two 1.5T MR scanners (voxel dimension: $0.66{\times}0.66{\times}1.1$ or $1.2\;mm^3$), and CTA on 64-slice CT scanners (voxel dimension: $0.42{\times}0.42{\times}0.63\;mm^3$). All the three examinations were completed within 40 days (median 19 days; range 1-40 days). Retrospective evaluation and measurement of diameter of 6 extracranial and 9 intracranial arterial segments was done by 2 experienced radiologists. Results: A total of 420 arterial segments were examined by CE-MRA, CTA and DSA. On DSA, 34 stenoocclusive lesions were noted at extracranial (n= 19) and intracranial (n = 15) vessels. For extracranial stenosis greater than 70%, sensitivity, specificity, positive predictive value (PPV) and negative predictive values (NPV) were 94.7%, 98.7%, 90.0% and 99.3% on CE-MRA, and 94.7%, 99.3%, 94.7% and 99.3% on CTA. For intracranial stenosis greater than 50%, sensitivity; specificity, PPV and NPV were 93.3%, 98.3%, 77.8%and 99.6% on CE-MRA, and 86.7%, 97.9%, 72.2% and 99.1 % on CTA, with DSA as the standard of reference. Conclusion : Supraaortic CE-MRA is as reliable as CTA in depicting the arterial stenosis, and is effective in screening of significant stenosis of both extracranial and intracranial arterial stenosis.

  • PDF