• Title/Summary/Keyword: standard reference materials

Search Result 357, Processing Time 0.024 seconds

Application of Methane Mixed Plasma for the Determination of Ge, As, and Se in Serum and Urine by ICP/MS

  • Park, Kyung-Su;Kim, Sun-Tae;Kim, Young-Man;Kim, Yun-je;Lee, Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.3
    • /
    • pp.285-290
    • /
    • 2003
  • An analytical method for the simultaneous determination of trace Ge, As and Se in biological samples by inductively coupled plasma/mass spectrometry has been investigated. The effects of added organic gas into the coolant argon gas on the analyte signal were studied to improve the detection limit, accuracy and precision. The addition of a small amount of methane (10 mL/min.) into the coolant gas channel improved the ionization of Ge, As and Se. The analytical sensitivity of the proposed Ar/CH₄system was superior by at least two-fold to that of the conventional Ar method. In the present method, the detection limits obtained for Ge, As and Se were 0.014, 0.012 and 0.064 ㎍/L, respectively. The analytical reliability of the proposed method was evaluated by analyzing the certified standard reference materials (SRM). Recoveries of 99.9% for Ge, 103% for As, 96.5% for Se were obtained for NIST SRM of freeze dried urine sample. The proposed method was also applied to the biological samples.

Effusion in magnetic resonance imaging of the temporomandibular joint (측두하악관절 자기공명영상에서의 삼출에 관한 연구)

  • Nah Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.33 no.1
    • /
    • pp.1-4
    • /
    • 2003
  • Purpose : The purpose of this study was to investigate the distribution and frequency of temporomandibular joint (TMJ) effusion in magnetic resonance (MR) images of patients with disc displacements. Materials and Methods: On T2 weighted MR images of 148 TMJs taken from 74 patients presenting with TMJ pain and dysfunction, we assessed the cases showing TMJ effusion, defined as an amount of fluid that exceeded the maximum amount seen in a control group of asymptomatic volunteers. The amount of TMJ fluid was graded as: I (none or minimal), II (moderate), III (marked), and IV (extensive), according to a standard set by a reference. Disc displacement categories were also recorded. Results: Of the 148 TMJs examined in this study, 52 joints (35.1%) presented with joint effusion, 24 (16.2%) showing bilateral joint effusion. 38 joints showed upper joint space effusion, 3 showed lower joint space effusion, and 11 showed both upper and lower joint space effusion. 96 joints (64.9%) had grade I joint fluid, 27 (18.2%) grade II, 15 (10.1 %) grade III, and 10 (6.8%) grade IV. 80.0% of the joints presenting with grade IV effusion showed disc displacement without reduction. Conclusion: Joint effusion was found not only in upper, but also in lower joint spaces. The higher the effusion grade, the greater the frequency of disc displacement without reduction.

  • PDF

Prediction of mechanical properties of limestone concrete after high temperature exposure with artificial neural networks

  • Blumauer, Urska;Hozjan, Tomaz;Trtnik, Gregor
    • Advances in concrete construction
    • /
    • v.10 no.3
    • /
    • pp.247-256
    • /
    • 2020
  • In this paper the possibility of using different regression models to predict the mechanical properties of limestone concrete after exposure to high temperatures, based on the results of non-destructive techniques, that could be easily used in-situ, is discussed. Extensive experimental work was carried out on limestone concrete mixtures, that differed in the water to cement (w/c) ratio, the type of cement and the quantity of superplasticizer added. After standard curing, the specimens were exposed to various high temperature levels, i.e., 200℃, 400℃, 600℃ or 800℃. Before heating, the reference mechanical properties of the concrete were determined at ambient temperature. After the heating process, the specimens were cooled naturally to ambient temperature and tested using non-destructive techniques. Among the mechanical properties of the specimens after heating, known also as the residual mechanical properties, the residual modulus of elasticity, compressive and flexural strengths were determined. The results show that residual modulus of elasticity, compressive and flexural strengths can be reliably predicted using an artificial neural network approach based on ultrasonic pulse velocity, residual surface strength, some mixture parameters and maximal temperature reached in concrete during heating.

Analysis on Stitched Mode I Specimen Using Spring Elements

  • Tapullima, Jonathan;Sim, Hyung Woo;Kweon, Jin Hwe;Choi, Jin Ho
    • Composites Research
    • /
    • v.32 no.2
    • /
    • pp.102-107
    • /
    • 2019
  • Several studies related to reinforce composites structures in the through thickness direction have been developed along the years. As follows, in this study a new reinforced process is proposed based on previous experimental results using a novel stitching process in T-joints and one-stitched specimens. It was established the need to perform more analysis under standard test methods to obtain a better understanding. FEM analysis were compared after performed mode I interlaminar fracture toughness test, using different stitching patterns to analyze the through thickness strength with reference laminates without stitching. The stitching patterns were defined in $2{\times}2$ and $3{\times}3$, where the upper and lower head of the non-continuous stitching process (I-Fiber) has proven to influence in a higher through thickness strength of the laminate. In order to design the numerical model, cohesive parameters were required to define the surface to surface bonding elements using the cohesive zone method (CZM) and simulate the crack opening behavior from the double cantilever beam (DCB) test.

Determination of Ag(I) at a Chemically Modified Electrode Based on 2-Imino-cyclopentane-dithiocarboxylic Acid

  • Jeong-Sik Yeom;Mi-Sook Won;Sung-Nak Choi;Yoon-Bo Shim
    • Bulletin of the Korean Chemical Society
    • /
    • v.11 no.3
    • /
    • pp.200-205
    • /
    • 1990
  • Chemically modified electrodes(CMEs), based on 2-imino-1-cyclopentane-dithiocarboxylic acid (icdc) containing carbon paste, have been characterized using cyclic voltammetric techniques. Ag(I) was chemically deposited on the CMEs, and voltammograms were obtained with the electrode in a separate buffer solution. The CME surface can be regenerated with exposure to acid and reused for deposition. In 10 deposition/measurement/regenerate cycles, the linear response have been reproduced up to $1{\times}10^{-6}$ M in linear sweep voltammetry and 1${\times}$10-8 M in differential pulse voltammetry with relative standard deviation of 5.2% and 12.4%, respectiveiy. The sensitivity increased with deposition time and scanning rate, and detection limit was $1{\times}10^{-7}M\;and\;1{\times}10^{-9}M$ at 20 minutes deposition in the linear sweep voltammetry and differential pulse voltammetry, respectively. The presence of some metal ions does not influence the silver ion response. Satisfactory results were obtained for the analysis of the silver ion for a variety of reference materials without interference of Hg ion at the condition of pH = 5-6.

Determination of k0 factors of short-lived nuclides 46mSc and 110Ag for the k0-NAA

  • Truong Son Truong;Van Doanh Ho;Manh Dung Ho
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3202-3205
    • /
    • 2023
  • The k0-standardization neutron activation analysis method has successfully determined the mass fraction of elements of interest using around a hundred analytical radionuclides. However, several very short-lived nuclides with half-life less than 100 s have not been used at Dalat research reactor. One of the reasons is that the values of k0-factors of these nuclides are significantly different. Therefore, this work focused on re-determination and evaluation of k0-factors of very short-lived nuclides 110Ag (T1/2 = 24 s) and 46mSc (T1/2 = 18.75 s). The results of determination of the short-lived nuclides revealed that k0-factor of 110Ag is significantly difference between the existing data and the obtained results in this work. The evaluation of the k0-factors was done by using the obtained results for application of k0-NAA for NIST-1566b and NIST-2711A standard reference materials.

Amendment of the Inspection Standard for Diagnostic Radiation Equipment Applying IEC 60601-1-3: Medical Electrical Equipment - Part 1-3: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Radiation Protection in Diagnostic X-ray Equipment (KS C IEC60601-1-3: 의료용 전기기기-제1-3부: 기본 안전 및 필수 성능에 관한 일반 요구사항-보조표준: 진단용 X선 장치의 방사선 방어를 적용한 진단용 방사선 발생장치의 검사기준 개선안)

  • Park, Hye-Min;Kim, Jung-Min;Kim, Jung-Su;Kim, Seong-Ok;Choi, Young-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2018
  • The diagnostic radiation equipment is managed in accordance with the "Rules for Safety Management of Diagnostic Radiation Equipment" enacted in 1995. The equipments should be inspected before use and every three years after use in accordance with the [Appendix 1] of the same rule. The inspection standard has been maintained without particular revision since enacted. But, over the past two decades new types of equipments have been manufactured and used. So, it is necessary to revise [Appendix 1] by making inspection items and inspection standards. In this study, we revised the classification system of equipments and reviewed international standards of IEC 60601 series, IEC 61223 series and AAPM TG 18 On-line Report No.03. And identified the problem of current inspection standards. Through this, we revised, deleted and added the inspection items and inspection standard of each equipment to meet the domestic circumstances. As a result of the study, we reorganized the classification system of equipment which are current classified as 5 classes into 22 classes as X-ray system etc. (7 classes), CT system etc. (5 classes) and Dental X-ray system etc. (10 classes). And then, we developed 70 inspection items for 6 types of equipments according to the reorganized classification system of equipments. The inspection items and inspection standards derived from this study have been proposed to the KCDC and will be applied to the revision of the Rule's [Appendix 1]. Therefore, we expect to be used as reference materials for domestic medical center, inspection institutions, and equipment manufacturing import companies.

METAMERISM IN COMPOSITE RESINS UNDER FIVE STANDARD ILLUMINANTS - D65, A, C, FCW AND TL84 (복합레진의 조건등색에 관한 연구)

  • Park, Ki-Jeong;Hwang, Yun-Chan;Kim, Sun-Ho;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.5
    • /
    • pp.402-408
    • /
    • 2003
  • This study was done to present a criterion in selection of the most proper light sources and materials by measuring metamerism index(MI) of the light curing composite resins with spectrocolorimeter. Metamerism is defined when two objects appear to be the same color in one illuminant but different in another. This is due to the fact that they have different spectral curves that fail to match under the second illuminant. In this study, A1 & A3 shade of five light curing composite resins (Esthet-X, Filteck Z250, Filteck A110. Charisma. Vitalescence) were chosen based on Vita shade. Five samples were made for shade of each product with Teflon mold (diameter: 15mm, thickness: 2mm). Metamerism index of each samples on a Barium sulfate plate($L^{*}=96.54,{\;}a^{*}=0.19,{\;}b^{*}=0.01$) prepared for sample fixation were measured with spectrocolorimeter(Miniscan XE plus. Model 4000s. Hunter Lab. USA) by applying standard light source D^{65}, C. Fcw, TL84 and A. Standardization was done with reference standard(X=80.8, Y=85.7, Z=90.8) and light trap. The results were as follows. 1. Different resins with same Vita shade showed recognizable color difference (${\delta}E^{*}>2$). 2. All composites had MI below accepted value 0.5 between standard illuminant(D$_{65}$, C, & A) and below 1.5 under fluorescent condition (Fcw & TL84). 3. MI value between $D^{65}$ and A showed higher value than MI value between other source of light(p<0.01). 4. All resins except Z250 showed MI value that A3 is higher than A1 between $D^{65}$ and A(p<0.05).except Z250 showed MI value that A3 is higher than A1 between $D^{65}$ and A(p<0.05).

Development of Ecotoxicological Standard Methods using Early Life Stage of Marine Rotifer Brachionus plicatilis and Benthic Copepod Tigriopus japonicus (윤충류 Brachionus plicatilis 및 저서 요각류 Tigriopus japonicus의 초기 생활사를 이용한 해양생태독성시험 방법에 관한 연구)

  • Lee, Seung-Min;Park, Gyung-Soo;Yoon, Sung-Jin;Kang, Young-Shil;Oh, Jeong-Hwang
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.2
    • /
    • pp.129-139
    • /
    • 2008
  • Marine ecotoxicological standard method was applicated using marine rotifer and benthic copepod as primary consumer of marine ecosystem. Marine rotifer, Brachionus plicatilis and benthic copepod, Tigriopus japonicus were designated as standard test species with the endpoints of 24hr neonate mortality (24hr $LC_{50}$) and 48hr population growth (48hr $EC_{50}$) for rotifer, and 48hr nauplius mortality (48hr $LC_{50}$) for benthic copepod. Tests method was referred to those of ASTM (American Society for Testing and Materials) with the replacement of test species which are widely distributed in Korean waters. The two species showed a wide tolerance on salinity ($5{\sim}35\;psu$) and can be easily cultured in small space even they were not as sensitive as in the mortality test using the nauplius of marine invertebrates. However, these species revealed the significant "concentrationresponse relationship" tested with ocean disposal wastes, and reproducibility using cadmium as standard reference material between laboratories. Accordingly, these two species have good potential as test species for marine ecotoxicological test species. Also, we strongly recommend that at least one of these species be included in the test species of "battery test" in marine bioassay.

A Study on Actual Conditions and Sizing Systems of Domestic Glove Production Companies (국내 장갑 제조업체의 실태조사 및 치수체계에 관한 연구)

  • Choi Hei-Sun;Kim Eun-Kyong
    • Journal of the Korean Society of Costume
    • /
    • v.55 no.2 s.92
    • /
    • pp.116-128
    • /
    • 2005
  • The aim of this study is to understand problems with both fit and sizing system of gloves by analyzing the glove production industries with an emphasis on the sizing system, production measurement system, and general marking situation. Also, to suggest the basic raw materials for improving sizing system for gloves, actual glove control sizes were compared to the anthropometric data of the previous study Fifteen domestic production companies were participated in this study-Domestic glove production companies established their own sizing system by copying inter-national brand's glove sizing system or by their experience. The Korean Standard of gloves and the 1997 Korean Standard Anthropometrics Measurement for producing glove patterns are not considered because of its discordance with the reality of the required measurements. Domestic glove production companies used different size designation and labeling system. Size measurement unit also showed difference among the glove production companies. Some companies used 'cm', some used 'mm', some used 'inch' for the measurement unit. In general, companies produced 5 to 4 sizes in one design of glove and the production was the highest in M and L size. In 9 out of 15 companies preferred control size as hand length and hand circumference. For reference size, most of the companies preferred finger circumference, finger length, palm length, hand breadth, crotch height, and hand thickness. Actual glove sizes were compared to the anthropometric data of the previous study. The results indicated that most of the measurements of actual glove sizes were significantly larger than the anthropometric data.