The Normal Predicted Value of Peak Expiratory Flow(PEF) Measured by the Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters (Peak Flow Meter로 측정한 최대호기류속도(PEF)의 추정정상치 및 가타 환기기능검사와의 상관관계)

  • Kim, Min-Chul;Kwon, Kee-Buem;Yim, Dong-Hyun;Song, Chang-Seuk;Jung, Yong-Seuk;Jang, Tae-Won;Yeu, Ho-Dae;Jung, Maan-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1000-1011
    • /
    • 1998
  • Background: For the diagnosis or evaluation of airway obstruction in bronchial asthma and chronic obstructive lung disorders, various parameters derived from the forced expiratory volume curve and maximal expiratory flow volume curve have been used. Recently the peak expiratory flow(PEF) measured by the peak flow meter is widely used because of its simplicity and convenience. But there were still no data of the predicted normal values measured by the peak flow meter in Korea. This study was to obtain the predicted normal value of PEF and to know the accuracy of this value to predict $FEV_1$. Method: The measurements of PEF by the MiniWright peak flow meter and several parameters derived from the forced expiratory volume and maximal expiratory flow volume curves by the Microspiro HI 501(Chest Co.) were done in 129 men and 125 women without previous history of the respiratory diseases. The predicted normal values of parameters according to the age and the height were obtained, and the regression equation of $FEV_1$ by PEF was calculated. Results: The predicted normal values of PEF(L/min) were -2.45$\times$Age(year) +1.36 $\times$ Height(cm)+427 in men, and -0.96 $\times$ Age (year) + 2.01 $\times$ Height (cm) + 129 in women. FEFmax derived from the maximal expiratory flow volume curve was less than by 125 L/min in men and 118 L/min in women respectively compared to PEF. $FEV_1$(ml) predicted by PEF was 5.98 $\times$ PEF(L/min) + 303 in men, and 4.61 $\times$ PEF(L/min) + 291 in women respectively. Conclusion : The predicted normal value of PEF measured by the peak flow meter was calculated and it could be used as a standard value of PEF while taking care of patients with airway obstruction. $FEV_1$, the gold standard of ventilatory function, could be predicted by PEF to a certain extent.

  • PDF

Evaluation of a rapid diagnostic kit "BIOLINE RSVTM" for the detection of respiratory syncytial virus (Respiratory Syncytial Virus 감염의 조기 진단 kit "바이오라인 알에스브이TM"의 평가)

  • Kim, So-Hee;Sung, Ji-Yeon;Yang, Mi-Ae;Eun, Byung-Wook;Lee, Jin-A;Choi, Eun-Hwa;Lee, Hoan-Jong
    • Pediatric Infection and Vaccine
    • /
    • v.14 no.1
    • /
    • pp.91-96
    • /
    • 2007
  • Purpose : This study was performed to evaluate a new rapid diagnostic kit (BIOLINE $RSV^{TM}$; Standard Diagnostics Inc., Yongin, Korea), a lateral-flow immunoassay, in the detection of respiratory syncytial virus (RSV) from the nasopharyngeal aspirates (NPA) of children with lower respiratory tract infections (LRTIs) in comparison with other diagnostic methods. Methods : Three hundred and nineteen NPAs were selected from a large pool of NPAs that had been obtained from children with LRTIs. All specimens had already been tested for RSV by culture and immunofluorescent (IF) test, and had been kept frozen. Tests with BIOLINE $RSV^{TM}$ were performed at least twice. All who conducted the experiments or interpreted the test results were blinded to the results of both culture and IF tests. Results : One hundred seven (97.3%) of 110 specimens that were positive for RSV by both culture and IF test, 29 (87.9%) of 33 that were positive by IF test only, 20 (76.9%) of 26 that were positive by culture only, and 140 (93.3%) of 150 that were negative by both methods were negative for RSV by BIOLINE $RSV^{TM}$. By combining the above results, the following 5 diagnostic values of BIOLINE $RSV^{TM}$ were determined in comparison with viral culture or IF test; sensitivity, 92.3% (156/169, 95% confidence interval [CI], 87.1-97.5%); specificity, 93.3% (140/150, 95% CI, 88.4-98.2%); positive predictive value, 94.0% (156/166, 95% CI, 89.5-98.5%); negative predictive value, 91.5% (140/143, 95% CI, 86.0-97.0%); and agreement, 95.9% (306/319, 95% CI, 92.1-99.7%), respectively. Conclusion : This study revealed that BIOLINE $RSV^{TM}$ demonstrated good sensitivity and specificity for the detection of RSV antigen from NPAs of children with LRTIs. Because of simple methods and quick results, this test may be useful for the diagnosis of RSV infection during the epidemic periods.

  • PDF

Quality Control of Upper Gastrointestinal Series(UGIS) by The Image Quality Evaluation Table of Korea and Japan (한.일 화질평가표에 의한 우리나라 위장조영검사의 품질관리)

  • Oh, Hye-Kyong;Kim, Jung-Min;Kim, Chang-Gyun;Park, Young-Seon;Seon, Jong-Ryul;Choi, In-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.277-285
    • /
    • 2011
  • To determine the quality control of UGIS, we acquired 105 patients sampling image at 21 general screening centers. The results of image quality evaluation table containing two countries's UGIS showed that the mean of image qualified education table of our country was 73.3 and the standard error was 4.49; In addition, 19 organizations of 21 general screening centers were given appropriate judgement. The average of image qualified education table of Japan was 58 and the standard error was 4.45. Only 8 organizations were given appropriate judgement. Although we made the image quality evaluation tables with same images, there were many differences in the result of two tables. We figured out the problem about the description of whole stomach and photograph skills. Furthermore, we analysed the situation of the UGIS at each general screening center with the acquired images. The biggest problem of the UGIS of our country was that the procedures were performed without clear medical methods. Methods of UGIS were different at every 21 general screening centers, and most of them did not take exam of anterior surface of stomach of the UGIS. In addition, some general screening centers did not include mucosal relief method or esophagography which is required to include in the image qualified education table of our country. Because polisography is used in the same body position, the problem occured about indiscreet exposure dose of patients. Therefore we have to make an effort to get X-ray images which have enough diagnosis information by the quality control of UGIS.

Detection and Differentiation of Herpes Simplex Virus 1 and 2, and Varicella-Zoster Virus in Vesicle Fluid, Joint Fluid and Serum using PCR Method (중합효소 연쇄반응에 의한 수포액, 혈액과 관절액에서 단순포진 바이러스 1, 2와 대상포진 바이러스의 검출과 감별)

  • Park, Hae-Kyung;Woo, So-Youn;Kim, Hyun-Jin;Lee, Chung-Hwa
    • The Journal of the Korean Society for Microbiology
    • /
    • v.35 no.2
    • /
    • pp.191-201
    • /
    • 2000
  • The viruses of Herpes Simplex Virus 1 (HSV-1), Herpes Simplex Virus 2 (HSV-2) and Varicella-Zoster virus (VZV) which belong to the alpha herpes subfamily are important human pathogens. When eruptions were not fully developed from these viral infections, clinical diagnosis was not always easy and required virological confirmation test. The above viruses were reactivated in individuals who were compromised in immune competence for one reason or another. Polymerase chain reaction (PCR) enables rapid and sensitive detection of HSV and VZV DNAs. Its sensitivity was largely influenced by choice of primers. Authors conducted a study to detect of those three viruses in human specimens including vesicle fluid and joint fluid and serum using PCR methods. Primers used for this study were the general primer pair GPHV-RU which was known to amplify within the genes enjoying the highest degree of homology between UL15 of HSV and UL42 of VZV. PCR with primers hybridized pair GPHV-RU amplifies a 396 bp with THP-1 and HSV-2 standard strain DNA and 405 bp with VZV standard strain DNA. Restriction enzyme cleavage with HpaII and DdeI were used to detect and distinguish DNAs of THP-1 and HSV-2 and VZV. The purpose of this study was a rapid and easy detection of VZV and THP-1 or HSV-2 from various clinical specimens (vesicle fluid, serum and joint fluid) by PCR method. Used methods were: HSV PCR with primer 1, 2 and HpaII RE digestion; VZV nested PCR; HSV PCR with primer A, Band BssHII RE digestion. 1) In 33 cases (33/42, 78.6%) VZV was detected single or mixed infection from 42 clinical specimens which included vesicle fluid (5), serum form respiratory infected children (10), serum from immune suppressed adult cancer patients (7) and joint fluid from arthritis patients (20). 2) In 20 cases (20/42, 47.6%) HSV was detected singly or mixed infection and 19 of those cases were HSV-2 and 1 case was THP-1. 3) In 19 cases (19/42, 45.2%) VZV was singly detected which included serum from respiratory infected children (6 cases), joint fluid from arthritis patients (9 cases), vesicle fluid (2 cases) and serum form immunosuppressed cancer patients (2 cases). 4) HSV was singly detected in 6 cases (6/42, 14.3%) which included joint fluid from arthritis patients (5 cases) and serum form respiratory infected children (1 cases). 5) 14 cases of VZV and HSV mixed infection (14/42, 33.3%) were detected. They included vesicle fluid (3 cases), serum form immunosuppressed cancer patients (4 cases), serum from respiratory infected children (2 cases) and joint fluid from arthritis patients (5 cases). 6) HSV-1 and HSV-2 detection and typing by HSV PCR with primer A, Band BssHII RE digestion method was more sensitive and the results were easier to detect than on other method.

  • PDF

Measurement of Image Quality According to the Time of Computed Radiography System (시간에 따르는 CR장비의 영상의 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Hwang, Sun-Kwang;Lee, Ik-Pyo;Kim, Ki-Won;Jung, Jae-Yong;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.365-374
    • /
    • 2015
  • The regular quality assurance (RQA) of X-ray images is essential for maintaining a high accuracy of diagnosis. This study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) of a computed radiography (CR) system for various periods of use from 2006 to 2015. We measured the pre-sampling MTF using the edge method and RQA 5 based on commission standard international electro-technical commission (IEC). The spatial frequencies corresponding to the 50% MTF for the CR systems in 2006, 2009, 2012 and 2015 were 1.54, 1.14, 1.12, and $1.38mm^{-1}$, respectively and the10% MTF for 2006, 2009, 2012, and 2015 were 2.68, 2.44, 2.44, and $2.46mm^{-1}$, respectively. In the NPS results, the CR systems showed the best noise distribution in 2006, and with the quality of distributions in the order of 2015, 2009, and 2012. At peak DQE and DQE at $1mm^{-1}$, the CR systems showed the best efficiency in 2006, and showed better efficiency in order of 2015, 2009, and 2012. Because the eraser lamp in the CR systems was replaced, the image quality in 2015 was superior to those in 2009 and 2012. This study can be incorporated into used in clinical QA requiring performance and evaluation of the performance of the CR systems.

Evaluation of the usefulness of prone position for reducing the image distortion due to respiration in PET/CT (PET/CT 검사 시 호흡에 따른 영상 왜곡 감소를 위한 엎드린 자세의 유용성 평가)

  • Lee, Han Wool;Kim, Jung Yul;Choi, Yong Hoon;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.59-63
    • /
    • 2019
  • Purpose The motion due to respiration of patients undergoing PET/CT is a cause of artifacts in image and registration error between PET and CT images. The degree of displacement and distortion for tumor, which affects the measurement of Standard Uptake Value (SUV) and lesion volume, is especially higher for tumors that is small or located at the base of lungs. The purpose of this study was to evaluate the usefulness of prone position in the correction of image distortion due to respiration of patients in PET/CT. Materials and Methods The imaging equipment used in this study was PET/CT Discovery 600 (GE Healthcare, MI, USA). 20 patients whose lesions were identified in the middle and lower lungs from May to August 2018 were enrolled in this study. After acquiring whole body image in the supine position, additional images of the lesion area were obtained in the prone position with the same conditions. SUVmax, SUVmean, and volume of the lesion were measured for each image, and the displacement of the lesion on PET and CT images were measured, compared, and analyzed. Results The SUVmax, SUVmean, and volume, and displacement of the lesion were $4.72{\pm}2.04$, $3.10{\pm}1.38$, $4.68{\pm}3.20$, and $4.64{\pm}1.88$, respectively for image acquired in the supine position and $5.89{\pm}2.42$, $3.97{\pm}1.65$, $2.13{\pm}1.09$, and $2.24{\pm}0.84$, respectively for image acquired in the prone position, indicating that, for all the lesions imaged, SUVmax and SUVmean were higher and volume and displacement were smaller in the images acquired in prone position compared to those acquired in supine one(p<0.05). Conclusion These results showed that the prone position PET/CT imaging improves the quality of the image by increasing the SUV of the lesion and reducing the respiratory artifacts caused by registration error between PET and CT images. It is considered that the PET/CT imaging in the prone position is helpful in the diagnosis of the disease as an economical and efficient methods that correct registration error for the lesions in basal lung and reduce artifacts.

Evaluation on Usefulness of Stereotactic Radio Surgery using $Fraxion^{(R)}$ System ($Fraxion^{(R)}$ System을 이용한 뇌 정위적 방사선 수술 유용성 평가)

  • Kim, Tae Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.345-354
    • /
    • 2014
  • Purpose : We evaluated the usefulness of $Fraxion^{(R)}$ system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. Materials and Methods : 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while $Fraxion^{(R)}$ system was used for the other 3 patients (group2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. Results : The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when $Fraxion^{(R)}$ system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using $Fraxion^{(R)}$ system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when s-thermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using $Fraxion^{(R)}$ system showed only 1.9%. All percentage were calculated with respect to average value. Conclusion : Using $Fraxion^{(R)}$ system including mouthpiece, Fraxion frame, frontpiece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.

Development of Extracting Solution for Soil Chemical Analysis Suitable to Integrated Ion-selective Micro-electrodes (집적형 이온선택성 미세전극 센서에 적합한 토양화학 분석용 침출액 종 개발)

  • Shin, Kook-Sik;Lim, Woo-Jin;Lee, Sang Eun;Lee, Jae Seon;Cha, Geun Sig
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.6
    • /
    • pp.513-521
    • /
    • 2009
  • The primary goal of this research was to develop an optimized analytical procedure for soil analysis based on ion-selective microelectrodes for agricultural purposes, which can perform on-site measurement of various ions in soil easily and rapidly. For the simple and rapid on-site diagnosis, an analysis of soil chemicals was performed employing a multicomponent-in-situ-extractant and an evaluation of ionselective microelectrodes were conducted through the regressive correlation method with a standard analytical approach widely employed in this area. Examination of sensor responses between various soil nutrient extractants revealed that 0.01M HCl and 1M LiCl provided the most ideal Nernstian response. However, 1M LiCl deteriorated the selective response for analytes due to high concentration (1M) of lithium cation. Thus, employing either 0.1M HCl as an extractant followed by 10 times dilution, or 0.01M HCl as an extractant without further dilution was chosen as the optimal extractant composition. A study of regressive correlation between results from ion-selective microelectrodes and those from the standard analytical procedure showed that analyses of $K^+$, $Na^+$, $Ca^{2+}$, and $NO_3{^-}$ showed the excellent consistency between two methods. However, the response for $NH_4{^+}$ suffered the severe interference from $K^+$. In addition, the selectivity for $Mg^{2+}$ over $Ca^{2+}$ was not sufficient enough since available ionophores developed so far do not provide such a high selectivity for $Mg^{2+}$. Therefore, as an agricultural on-site diagnostic instrument, the device in development requires further research on $NH_4{^+}$ analysis in the soil sample, development of $Mg^{2+}$-selective ionophore, and more detailed study focused on potassium, one of the most important plant nutrients.

Usefulness of CTAC Shift Revision Method of Artifact by Diaphragm in PET/CT (PET/CT 검사에서 횡격막에 의한 인공물의 CTAC Shift 보정방법의 유용성)

  • Ham, Jun Cheol;Kang, Chun Koo;Cho, Seok Won;Bahn, Young Kag;Lee, Seung Jae;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.71-75
    • /
    • 2013
  • Purpose: Currently, decrement revision using LDCT is used in PET/CT. But cold artifacts are often found in decrement revision image by mismatch between LDCT image and Emission image near diaphragm due to patient's respiration. This research studied reduction of cold artifact by patient's respiration using CTAC Shift among revision methods. Materials and Methods: From March to September in 2012, 30 patients who had cold artifacts by respiration were targeted using PET/CT Discovery 600 (GE Healthcare, MI, USA) equipment. Patients with cold artifacts were additionally scan in diaphragm area, and the image shown cold artifacts at whole body test were revised using CTAC Shift. Cold artifacts including image, additional scan image and CTAC Shift revision image were evaluated as 1~5 points with naked eye by one nuclear medicine expert, 4 radiotechnologists with over 5 year experience. Also, standard uptake value of 3 images was compared using paired t-test. Results: Additional scan image and CTAC Shift revision image received relatively higher score in naked eye evaluation than cold artifacts including image. The additional scan image and CTAC Shift revision image had high correlation as the results of ANOVA test of standard uptake value and did not show significant difference. Conclusion: When cold artifacts are appeared by patient's respiration at PET/CT, it causes not only patient inconvenience but troubles in test schedule due to extra radiation exposure and time consumption by additional scan. But if CTAC Shift revision image can be acquired with out additional scan, it is considered to be helped in exact diagnosis without unnecessary extra radiation exposure and additional scan.

  • PDF

Histamine Bronchial Provocation Test -Timed Tidal Breathing Technique- (히스타민 기관지유발 검사 -일정시간 흡입법-)

  • Chung, Yeon-Tae;Won, Kyung-Sook;Park, Hae-Shim
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.3
    • /
    • pp.270-276
    • /
    • 1994
  • Background: The measurement of nonspecific bronchial hyperreactivity is valuable for diagnosis and management of bronchial asthma. Methacholine or histamine is used for the pharmacologic provocation test. Usually a methacholine bronchial provocation test is performed by a dosing technique with counted number of breaths. A dosimeter is indispensable in the dosing technique. Recently a timed tidal breathing technique which dose not need an expensive dosimeter was introduced. We measured the degree of nonspecific bronchial hyperreactivity to histamine using a simple timed tidal breathing technique. Method: Forty two healthy volunteers, 12 patients with bronchial asthma(BA), 10 patients with rhinitis(RH) and 10 patients with upper respiratory infection(URI) participated in the study. The subject's nose was clipped and inhalation continued during tidal breathing for 2 minutes via a face mask. $FEV_1$ was measured at 30 seconds, 90 seconds after inhalation and inhalation of next solution was continued until there was a fall in $FEV_1$ of 20%. Histamine PC20 was defined as the concentration at 20% fall of $FEV_1$ and it was obtained from the log dose-response curve by linear interpolation. Results: Inhalation of serial dilution of histamine could be performed in all patients without significant side effects. The geometric mean${\pm}$standard deviation of histamine PC20 in healthy volunteers is $8.27{\pm}2.22mg/ml$, BA group $0.33{\pm}3.02mg/ml$, RH group $0.85{\pm}3.24mg/ml$, and URI group $1.47{\pm}1.98mg/ml$. Conclusion: Histamine bronchial provocation test using timed tidal breath method is a simple and suitable tool for management of patients with bronchial hyperreactivity.

  • PDF