• Title/Summary/Keyword: standard method

Search Result 13,733, Processing Time 0.045 seconds

Comparison of results between modified-Angoff and bookmark methods for estimating cut score of the Korean medical licensing examination

  • Yim, Mikyoung
    • Korean journal of medical education
    • /
    • v.30 no.4
    • /
    • pp.347-357
    • /
    • 2018
  • Purpose: The purpose of this study was to apply alternative standard setting methods for the Korean Medical Licensing Examination (KMLE), a criterion-referenced written examination, and to compare them to the conventional cut score used on the KMLE. Methods: The process and results of criterion-referenced standard settings (i.e., the modified-Angoff and bookmark methods) were evaluated. The ratio of passing and failing examinees determined using these alternative standard setting methods was compared to the results of the conventional criteria. Additionally, the external, internal and procedural evaluation of these methods were reviewed. Results: The modified-Angoff method yielded the highest cut score, followed sequentially by the conventional method and the bookmark method. The classification agreement between the modified-Angoff and bookmark methods was 0.720 measured by Cohen's ${\kappa}$ coefficient. The intra-panelist classification consistency of modified-Angoff method was higher than bookmark method. However, the inter-panelist classification consistency was vice versa. The standard setting panelists' survey results showed that the procedures of both methods were satisfactory, but panelists had more confidence in the results of the modified-Angoff method. Conclusion: The modified-Angoff method showed results that were more similar to those of the conventional method. Both new methods showed very high concordance with the conventional method, as well as with each other. The modified-Angoff method was considered feasible for adoption on the KMLE. The standard setting panelists responded positively to the modified-Angoff method in terms of its practical applicability, despite certain advantages of the bookmark method.

A Study on the Standard-interfaced Smart Farm Supporting Non-Standard Sensor and Actuator Nodes (비표준 센서 및 구동기 노드를 지원하는 표준사양 기반 스마트팜 연구)

  • Bang, Dae Wook
    • Journal of Information Technology Services
    • /
    • v.19 no.3
    • /
    • pp.139-149
    • /
    • 2020
  • There are now many different commercial weather sensors suitable for smart farms, and various smart farm devices are being developed and distributed by companies participating in the government-led smart farm expansion project. However, most do not comply with standard specifications and are therefore limited to use in smart farms. This paper proposed the connecting structure of operating non-standard node devices in smart farms following standard specifications supporting smart greenhouse. This connecting structure was proposed as both a virtual node module method and a virtual node wrapper method. In addition, the SoftFarm2.0 system was experimentally operated to analyze the performance of the implementation of the two methods. SoftFarm2.0 system complies with the standard specifications and supports non-standard smart farm devices. According to the analysis results, both methods do not significantly affect performance in the operation of the smart farm. Therefore, it would be good to select and implement the method suitable for each non-standard smart farm device considering environmental constraints such as power, space, distance of communication between the gateway and the node of the smart farm, and software openness. This will greatly contribute to the spread of smart farms by maximizing deployment cost savings.

A Study on the Measurement Uncertainty of Flowmeter Calibrator (유량계 교정장치의 측정불확도에 관한 연구)

  • Im, Gi-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.561-571
    • /
    • 2001
  • The standard uncertainty of flowrate measurement is obtained by combining that of independent variables. Gravimetric and volumetric method were applied to determine the flowrate and the standard uncertainties of flowrate measurement by both methods were evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainties of determining the flowrate were estimated from the sensitivity coefficient and the standard uncertainty of independent variables. For practical application, the methods for evaluating and expressing uncertainty in flow measurement were discussed. It was found that the uncertainties of the weighing and time measurement in gravimetric method, the volume and time measurement in volumetric method have dominant influence on that of flowrate measurement. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of flowrate measurement is shown clearly.

Character Segmentation in a Grayscale Image using the Standard Deviation (그레이스케일 영상에서 표준 편차를 이용한 문자 분할)

  • Jung, Min Chul
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.2
    • /
    • pp.27-31
    • /
    • 2012
  • This paper proposes a new method of character segmentation in a grayscale image using the standard deviation. Firstly, the proposed method scans vertically the region of interest in an image in order to calculate a standard deviation for each scan line. Characters' standard deviations are much bigger than the background's. Therefore, it is possible to segment characters vertically using the differentiation of those two types of standard deviations. Secondly, the method scans each vertically segmented image horizontally at this time, and then segments each image similarly. The proposed method is implemented using C language in an embedded Linux system for a high-speed real-time image processing. Experiments were conducted by using credit card images. The results show that the proposed algorithm is quite successful for most credit cards. However, the method fails in some credit cards with strong background patterns.

The Product Standard Costs System Constructionby Group and Application of Small and Medium Business (중소기업의 제품그룹별 표준원가시스템 구축 및 활용)

  • Kim, Pan-Soo
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.3
    • /
    • pp.153-168
    • /
    • 2011
  • In medium and small firm, the management system which is simple and where there is a practicality is required Ill)re than the management system which is complicated and minute of the centered around large company so that the introduction of the standard costs can be activated and it can be usefully used as a tool of management decisions. A difference between the standard costs introduction plan proposed in this paper and the preexistance study literature are as follows. In this paper, by breaking from the whole cost accounting aiming at all item, that is the traditional introduction method, and presenting the product cost accounting method by group the standards setting object was minimized and simplified. In this way, if the standards setting object is simplified, it is quick at the perimeter environment change as the little man power and flexibly it corresponds to and the cost information calculation which is exact with the setting up and maintenance of the efficient cost standard becomes available. As a result of applying for real through S corp., the usability of the method that the standard costs introduction method proposed in this paper produced the standard costs relatively short within period, it manages was verified. And the standard costs introduction method proposed in this paper went by the various cost information for each products, the management class did the management will decision which was objective and reasonable in the putting first.

Analysis of Residual Solvents in Food Packaging Materials Using Solid Phase Microextraction Method (Solid Phase Microextraction법을 이용한 식품포장재 중의 잔류용제 분석)

  • 서택교;박상현;이윤수;김정한;권익부
    • Journal of Food Hygiene and Safety
    • /
    • v.14 no.1
    • /
    • pp.76-83
    • /
    • 1999
  • Solid phase microextraction (SPME) was used for the determination of 6 standard solvents (methanol, isopropanol, methyl ethyl ketone, ethyl acetate, cyclohexane, toluene) in food packaging materials. SPME method is a solvent-free sample preparation technique in which a fused silica fiber coated with polymeric organic liquid is introduced into the headspace above the sample. SPME method using fiber coated polydimethylisiloxane (PDMS) was compared with static headspace (SHS) method used as a reference. It was found that the optimal adsorption condition using PDMS-SPME method was 2$0^{\circ}C$ for 15 minutes for the standard solvents. Detection limits, linearity, reproducibility and recovery of both SHS and PDMS-SPME methods have been determined using 6 standard solvents. Both methods were characterized by high reproducibility and good linearity. Using SHS methods, the mean recovery of the 6 standard solvents was ranged from 75.5% to 105.8% with a mean relative standard deviation (RSD) of 0.3% to 4.8%. With PDMS-SPME method, the mean recovery of the 6 standard solvents was ranged from 86.7% to 108.3% with a mean RSD of 0.4% to 2.5%. The detection limits of both methods were the same for toluene, cyclohexane and methyl ethyl ketone; those of PDMS-SPME method were higher than those of SHS method for methanol, isopropanol and ethyl acetate. PDMS-SPME fiber shoed excellent adsorption for non-polar solvents such as toluene, while it showed relatively low adsorption for polar solvents such as methanol.

  • PDF

A Study for Robustness of Objective Function and Constraints in Robust Design Optimization

  • Lee Tae-Won
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.10
    • /
    • pp.1662-1669
    • /
    • 2006
  • Since randomness and uncertainties of design parameters are inherent, the robust design has gained an ever increasing importance in mechanical engineering. The robustness is assessed by the measure of performance variability around mean value, which is called as standard deviation. Hence, constraints in robust optimization problem can be approached as probability constraints in reliability based optimization. Then, the FOSM (first order second moment) method or the AFOSM (advanced first order second moment) method can be used to calculate the mean values and the standard deviations of functions describing constraints and object. Among two methods, AFOSM method has some advantage over FOSM method in evaluation of probability. Nevertheless, it is difficult to obtain the mean value and the standard deviation of objective function using AFOSM method, because it requires that the mean value of function is always positive. This paper presented a special technique to overcome this weakness of AFOSM method. The mean value and the standard deviation of objective function by the proposed method are reliable as shown in examples compared with results by FOSM method.

Building a Rule-Based Goal-Model from the IEC 62304 Standard for Medical Device Software

  • Kim, DongYeop;Lee, Byungjeong;Lee, Jung-Won
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.8
    • /
    • pp.4174-4190
    • /
    • 2019
  • IEC 62304 is a standard for the medical device software lifecycle. Developers must develop software that complies with all specifications in the standard for licensing. However, because the standard contains not only a large number of specifications, but also domain-specific information and association relationships between specifications, it requires considerable effort and time for developers to understand and interpret the standard. To support developers, this paper presents a method for extracting the contents of the IEC 62304 standard as a goal model, which is the core methodologies of requirements engineering. The proposed method analyzes the grammar of the standard to robustly extract complex structures and various information from standard specifications and define rules that extract goals and links from syntactic element units. We validated the actual extraction process for the standard document experimentally. Based on the extracted goal model, developers can intuitively and efficiently comply with the standard and track specific information within the medical software and standard domains.

Variable Sampling Interval $\bar{X}$ Control Chart Using Weighted Standard Deviation Method (가중표준편차를 이용한 가변표본채취간격 $\bar{X}$ 관리도)

  • Chang, Youngsoon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.39 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • This article proposes a variable sampling interval (VSI) $\bar{X}$ control chart using weighted standard deviation (WSD) method for skewed populations. The WSD method decomposes the standard deviation of a quality characteristic into upper and lower deviations and adjusts control limits and warning limits of a control chart in accordance with the direction and degree of skewness. A control chart constant is derived for estimating the standard deviation of skewed distributions with the mean of sample standard deviations. The proposed chart is compared with the conventional VSI $\bar{X}$ control chart under some skewed distributions. Simulation study shows that the proposed WSD VSI chart can control the in-control average time to signal (ATS) as an adequate level better than the conventional VSI chart, and the proposed chart can detect a decrease in the process mean of a quality characteristic following a positively skewed distribution more quickly than the standard VSI chart.

The controversial points and a remedy on evaluation of heavy metal contamination in standard method for examination of soil in Korea. (국내 토양오염 공정시험방법중 중금속 관련 오염평가의 문제점과 개선책)

  • 오창환;유연희;이평구;박성원;이영엽
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.298-301
    • /
    • 2000
  • Heavy metals are extracted from stream sediments, roadside soils and sediments and soils and tailings from mining area using partial extraction, acid digestion and HF-digestion. Compared to amounts of heavy metals extracted using partial extraction, those extracted using acid digestion are higher by 2.0∼220.9 times in Cu, 2.4∼2806.1 times in Pb, 1.3∼121 times in Cd, 14.1∼1300885 times in Fe, 1.2∼271.5 times in Mn, 1.3∼372.5 times in Zn, 2.2∼1734.5 times in Cr. Although partial extraction, which extracts less amounts of heavy metals from soil compared to acid digestion, is used in domestic standard method for examination of soil, domestic soil standard for heavy metals in non-agricultural and industrial areas is higher than soil standard in foreign countries which use acid digestion, For improvement of the domestic standard method for assessment of soil, it is suggested to lower the domestic soil standard for heavy metals or to change pretreatment method for extracting heavy metals from partial extraction to acid digestion with modifying the soil standard.

  • PDF