Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF

An Investigation on the self-consciousness Symptoms of the Clerical Workers attendant upon Office Automation (사무 자동화에 따른 사무직 근로자의 건강과 연관된 자각 증상에 대한 조사연구)

  • Jung, Mi Wha
    • Korean Journal of Occupational Health Nursing
    • /
    • v.3
    • /
    • pp.54-70
    • /
    • 1993
  • According as the automation of clerical work(OA ; Office Automation) develops, the use of VDT(Visual or Video Display Terminal) is increasing suddenly. But, in proportion to the spread of office automation(OA tendency), the self-conciousness syptom attendant upon the work is appearing also (Kim, Jung Tae, Lee, Young Ook, 1990). The apparatuses of office enable the clerical workers to be convenient and perform mass businesses. But, they are increasing the opportunity to be exposed to VDT syndrom, techno stress, computer terminal disease, pain by muscle strain(RSI), bradycausia of noise nature, and electromagnetic waves, etc. which are referred to as the new type of occupational diseases to the workers. It is the real situation that the workers to use VDT is complaining of the physical inconvenience sense in the recent newspaper and literature, it is the point of time that the sydrome to come from VDT use and computer terminal disease, etc. must be classified into the occupational disease(Lee, Kwang Young 1990, Lee, Kyoo Hak 1990, Lee, Won Ho 1991, Lee, Si Young 1991, Lee, Joon 1991, Choi, Young Tae 1991, Heo, Seung Ho 1989). In addition, it is the real situation that the scientifitic study result about the scope that electromagnetic waves has influence on the human body has not been suggested yet, and criticism on the stable exposure permission standard about electromagnetic waves to be emitted from VDT and on the problem in the health about electromagnetic waves is continuing. (IEEE Spectrum, 1990). In addition according to the experience of nursery business of industry field, it is the real situation that the patients who consult complaining of physical and mental inconvenience sence, among the users of apparatus of office automation, are reaching 10% of the patients coming to doctor's room. Therefore, it is necessary to confirm the self-consciousness symptom that the clerical workers complain of multilaterally with the actual state examination about the use of the apparatuses of offices automaton. Thus, this study was tried as th basic data for the cosultation and education for the maintenance and furtherance of the health of workers as the nurse of industry field, by confirming the contents of self-consciousness symptom attendant upon the use of the apparatus for office outomation making the financial institution in which the spparatus for office automation in most frequently used as the subject, and by examining whether there is the difference according to the subject of study, the data were collected, by using the questionnaire method, making 200 workers who consented to the study participation as the subject, among the persons who have spent over 3 months since they used the apparatuses for office automation and didn't receive the treatment in hospital due to the clerical disease for recent 3 years. The period of data collection was from Oct. 9, 1991 to Oct. 12. As for the measurement instrument about the complaint if self-consciousness symptom attendant upon the use of apparatuses fo office automation, the question item on the complaint symptom of health problem attendant upon the treatment of VDT that Kim(1991) developed and on CMI health problem and the question items on the fatigue degree due to industry were used by previous examination to 25 persons. Collected data were analyzed with the statistical method such as percentage, arithmetic mean, Person correlation coeffient, Kai square verfication, t-test, ANOVA, etc. by using SPSS/PC+ program, and the result is as follows : 1. The self-consciousness symptom that the clerical workers complained of most frequetly appeared high in 'My eyes are tired'(99.4%), 'I feel fatigue and weariness'(99.4%), 'I feel that my head is heavy5(90.0%), 'eyesight fell'(88.8%), 'I have a stiff neck'(88.8%), 'I fell pain in the shoulder'(85.0%), 'I feel cold and painful in the eyes'(76.9%), 'I feel the dry sense of eyeball'(76.2%), 'My nerves are edgy, and I an fretful, (75.6%), 'I feel pain in the waist'(73.2%) and 'I fell pain in the back'(72.8%). It emerged that the subject use the apparatuses for office automation complained of self-consciousness symptoms related to visual symptoms and musculoskeletal symptoms. 2. As for the general feature of examination subjects, the result to see the distribution by classifying into sex, age, school career, use career of apparatuses for office automation, skillfulness degree of the use of apparatus for office automation, use hours of the apparatuses for office automation per 1 day, type of business of the apparatus for office automation, rest hours during the use of apparatus for office automation, satifaction degree of business of office automation, and work circumstance, etc. emerged as follows : As for the sex of subjects, the distribution showed that men were 58.8% and women were 41.3%, Age was average 26.9. As the distribution of school career, the distribution showed that4below the graduation of high school' was 58.8%, 'graduation from junior college-university' was 35.0%, and 'over graduate school' was 6.3%. In the question to ask the existence or non-existence of experience of health consultation in connection with the work of office automation, the response that I had the consultation exprience and I feel the necessity emergerd as 90.1% And, the case that the subject who didn't wear the glasses or lens before using the OA apparatus wear glasses or lens after using OA apparatus emerged as 28.3% of whole. As for the existence or non-existence of use career of OA apparatus, the case under 3 years was highest as 52. 7%. As for the skillfulnness degree about the use of apparatus for office automation, most of them are skillful with the fact that 'common' was 44.4%, 'skill' was 42.5%, and 'unskillful' was 13.1% As for the use average hours of the apparatus for office automation per 1 day, the distribution showed that the case under 3-6 hours was 33.1%, the case under 6-9 hours was 28.1%, the case under 3 hours was 30.6%, and the case over 9 hours was 8.1% Main OA business and the use hours for 1 day showed in the order of keeping and retrieval, business of information transmission(162min), business of information transmission(79.3 min), business of document framing(55.5 min), and business of duplication and printing(25.4min). as for the rest during the use of apparatus for affice automation, that I take rest occasion demands the major portion, but that I take after completing the work emerged as 33.8%. Though the subiness gets to be convenient by the use of the apparatus for of office automation, respondents who showed the dissatisfaction about the present OA business emergd high as 78.1%. The work circumstances of each office was good with the fact that the temperature of office was 21.8, noise was average 42.7db, and the illumination was average 364.4 lx, in the light of ANSi/HFS 100 Standard. 3. Sight syptom, musculoskeletal symptom, skin and other symptoms showed the significant difference according to the extent of skillfulness of the apparatus for office automation. All the symptoms exept skin symptom showed the difference according to the use hours of the apparatus for office automation. All the question items exept the sytoms of digestive organs and the rest hours during the apparatus for office automation showed the signicant difference. The question item which showed the signicant difference from the satisfaction degree of present OA business showed the significant difference from all the question item classified into 6 groups. But, age and school career didn't significant difference from the complaint of any self-consciousness symptoms.

    . In conclusion, the self-consciousness symptoms of the subjects to use OA apparatus appeared differently, according to sex distiction, skillfull degree of OA apparatus, use hours of OA apparatus, the rest hours during th use of OA apparatus, and the satiafaction degree of persent business. Therefore, it is necessary that the nurse in the inuctry field must recognize to receive the education about the human technological physical condition which is most proper for te use of OA apparatus and about the proper rest method until they get accustomed to the use of OA apparatus. In addition, the simple exercise relax the tention of muscle due to the repetitive simple movement, and the education for the protection of eyesight are necessary.

  • PDF
  • The Improvement Measurement on Dispute Resolution System for Air Service Customer (항공서비스 소비자 분쟁해결제도의 개선방안)

    • Lee, Kang-Bin
      • The Korean Journal of Air & Space Law and Policy
      • /
      • v.33 no.2
      • /
      • pp.225-266
      • /
      • 2018
    • In 2017, 1,252 cases of damages relief related to air passenger transport service were received by the Korea Consumer Agency, a 0.8% drop from 1,262 cases in 2016, the first decline since 2013. In 2017, 444 cases (35.4%) out of received cases of damages relief in the field of air passenger service received by the Korea Consumer Agency were agreed on, and out of cases that were not agreed on, the most number of 588 cases (47.0%) were concluded due to information provision and counseling, and 186 cases (14.9%) were applied to the mediation of the Consumer Dispute Mediation Committee. Major legislations that contain regulations for the damages relief and disputes resolution of air service consumers include the Aviation Business Act and the Consumer Fundamental Act, etc. The Aviation Business Act provides the establishment and implementation of damage relief procedure and handling plan, and the receiving and handling of request of damage relief by air transport businessman, and the notice of protection standard for air traffic users. The Consumer Fundamental Act provides the establishment and management of the consumer counseling organization, the damage relief by the Korea Consumer Agency, the consumer dispute mediation, and the enactment of the criteria for resolving consumer disputes. The procedures for damages relief of air service consumers include the receiving and handling of damages relief by air transport businessman, the counseling, and receiving and handling of damages relief by the Consumer Counseling Center, the advice of mutual agreement by the Korea Consumer Agency, and the dispute mediation system by the Consumer Dispute Mediation Committee. The current system of damage relief and dispute mediation for air service consumer have the problem in the exemption from obligation of establishment and implementation of damage relief plan by air transport businessman under the Aviation Business Act, the problem in the exemption from liability in case of nonfulfillment and delay of transport by aviation businessman under the criteria for resolving consumer disputes in the aviation sector, and the uppermost limit in procedure progress and completion of consumer dispute mediation under the Consumer Fundamental Act. Therefore, the improvement measurements of the relevant system for proper damage relief and smooth dispute mediation for air service consumer are to be suggested as follows: First is the maintenance of the relevant laws for damage relief of air service consumer. The exemption regulation from obligation of establishment and implementation of damage relief plan by air transport businessman under the Aviation Business Act shall be revised. To enhance the structualization and expertise of the relevant regulation for protection and damage relief of air service consumer, it will be necessary to prepare the separate legislation similar to the US Federal Regulation 14 CFR and EU Regulation EC Regulation 261/2004. Second is the improvement of criteria for resolving air service consumer disputes. For this, it will be necessary to investigate whether the cause of occurrence of exemption reason was force majeure, and distinguish the exemption from liability in case of nonfulfillment and delay of transport by aviation businessman under the criteria for resolving consumer disputes in the aviation sector, and revise the same as exemption reasons regulated under the air transport chapter of the Commercial Act and Montreal Convention 1999, and unify the compensation criteria for the nonfulfillment of transport that the substitute flight was provided and the delay of transport. Third is the reinforcement of information provision for damage relief of air service consumer. Aviation-related government agencies and concerned agencies should cooperate with airlines and airports to provide rapidly and clearly diverse information to the air traffic users, including laws and policies for damages relief of air service consumers. Fourth is the supplement to the effectiveness, etc. of consumer dispute mediation. If there is no sign of acceptance for dispute mediation, it is not fair to regard it as acceptance, therefore it will be necessary to add objection system. And if a dispute resolution is requested to another dispute settlement agency in addition to the Consumer Dispute Mediation Committee, it is excluded from the damage relief package, but it should be allowed for the party to choose a mediation agency. It will be necessary to devise the institutional measures to increase the completion rate of mediation so that the consumer dispute can be resolved efficiently through the mediation. Fifth is the introduction of the air service consumer arbitration system. A measure to supplement the limitations of the consumer dispute mediation system is to introduce the consumer arbitration system, but there are two measurements which are the introduction of the consumer arbitration under the Consumer Fundamental Act and the introduction of the consumer arbitration under the Arbitration Act. The latter measurement is considered to be appropriate. In conclusion, as a policy task, the government should prepare laws and system to enhance the prevention and relief of damages and protection of the rights and interests of air service consumers, and establish and implement the consumer-centric policy for the advancement of air service.

    Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

    • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
      • The Journal of Korean Society for Radiation Therapy
      • /
      • v.25 no.2
      • /
      • pp.123-129
      • /
      • 2013
    • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

    • PDF

    Application of Westgard Multi-Rules for Improving Nuclear Medicine Blood Test Quality Control (핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용)

    • Jung, Heung-Soo;Bae, Jin-Soo;Shin, Yong-Hwan;Kim, Ji-Young;Seok, Jae-Dong
      • The Korean Journal of Nuclear Medicine Technology
      • /
      • v.16 no.1
      • /
      • pp.115-118
      • /
      • 2012
    • Purpose: The Levey-Jennings chart controlled measurement values that deviated from the tolerance value (mean ${\pm}2SD$ or ${\pm}3SD$). On the other hand, the upgraded Westgard Multi-Rules are actively recommended as a more efficient, specialized form of hospital certification in relation to Internal Quality Control. To apply Westgard Multi-Rules in quality control, credible quality control substance and target value are required. However, as physical examinations commonly use quality control substances provided within the test kit, there are many difficulties presented in the calculation of target value in relation to frequent changes in concentration value and insufficient credibility of quality control substance. This study attempts to improve the professionalism and credibility of quality control by applying Westgard Multi-Rules and calculating credible target value by using a commercialized quality control substance. Materials and Methods : This study used Immunoassay Plus Control Level 1, 2, 3 of Company B as the quality control substance of Total T3, which is the thyroid test implemented at the relevant hospital. Target value was established as the mean value of 295 cases collected for 1 month, excluding values that deviated from ${\pm}2SD$. The hospital quality control calculation program was used to enter target value. 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T of Westgard Multi-Rules were applied in the Total T3 experiment, which was conducted 194 times for 20 days in August. Based on the applied rules, this study classified data into random error and systemic error for analysis. Results: Quality control substances 1, 2, and 3 were each established as 84.2 ng/$dl$, 156.7 ng/$dl$, 242.4 ng/$dl$ for target values of Total T3, with the standard deviation established as 11.22 ng/$dl$, 14.52 ng/$dl$, 14.52 ng/$dl$ respectively. According to error type analysis achieved after applying Westgard Multi-Rules based on established target values, the following results were obtained for Random error, 12s was analyzed 48 times, 13s was analyzed 13 times, R4s was analyzed 6 times, for Systemic error, 22s was analyzed 10 times, 41s was analyzed 11 times, 2 of 32s was analyzed 17 times, $10\bar{x}$ was analyzed 10 times, and 7T was not applied. For uncontrollable Random error types, the entire experimental process was rechecked and greater emphasis was placed on re-testing. For controllable Systemic error types, this study searched the cause of error, recorded the relevant cause in the action form and reported the information to the Internal Quality Control committee if necessary. Conclusions : This study applied Westgard Multi-Rules by using commercialized substance as quality control substance and establishing target values. In result, precise analysis of Random error and Systemic error was achieved through the analysis of 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T rules. Furthermore, ideal quality control was achieved through analysis conducted on all data presented within the range of ${\pm}3SD$. In this regard, it can be said that the quality control method formed based on the systematic application of Westgard Multi-Rules is more effective than the Levey-Jennings chart and can maximize error detection.

    • PDF

    The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

    • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
      • The Korean Journal of Nuclear Medicine Technology
      • /
      • v.14 no.2
      • /
      • pp.21-25
      • /
      • 2010
    • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

    • PDF

    Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

    • Kim, Tae-Han;Choi, Boo-Hun
      • Journal of the Korean Institute of Landscape Architecture
      • /
      • v.48 no.5
      • /
      • pp.80-88
      • /
      • 2020
    • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

    Effect of Dose Rate Variation on Dose Distribution in IMRT with a Dynamic Multileaf Collimator (동적다엽콜리메이터를 이용한 세기변조방사선 치료 시 선량분포상의 선량률 변화에 따른 효과)

    • Lim, Kyoung-Dal;Jae, Young-Wan;Yoon, Il-Kyu;Lee, Jae-Hee;Yoo, Suk-Hyun
      • The Journal of Korean Society for Radiation Therapy
      • /
      • v.24 no.1
      • /
      • pp.1-10
      • /
      • 2012
    • Purpose: To evaluate dose distribution differences when the dose rates are randomly changed in intensity-modulated radiation therapy using a dynamic multileafcollimator. Materials and Methods: Two IMRT treatment plans including small-field and large-field plans were made using a commercial treatment planning system (Eclipse, Varian, Palo Alto, CA). Each plan had three sub-plans according to various dose rates of 100, 400, and 600 MU/min. A chamber array (2D-Array Seven729, PTW-Freiburg) was positioned between solid water phantom slabs to give measurement depth of 5 cm and backscattering depth of 5 cm. Beam deliveries were performed on the array detector using a 6 MV beam of a linear accelerator (Clinac 21EX, Varian, Palo Alto, CA) equipped with 120-leaf MLC (Millenium 120, Varian). At first, the beam was delivered with same dose rates as planned to obtain reference values. After the standard measurements, dose rates were then changed as follows: 1) for plans with 100 MU/min, dose rate was varied to 200, 300, 400, 500 and 600 MU/min, 2) for plans with 400 MU/min, dose rate was varied to 100, 200, 300, 500 and 600 MU/min, 3) for plans with 600 MU/min, dose rate was varied to 100, 200, 300, 400 and 500 MU/min. Finally, using an analysis software (Verisoft 3.1, PTW-Freiburg), the dose difference and distribution between the reference and dose-rate-varied measurements was evaluated. Results: For the small field plan, the local dose differences were -0.8, -1.1, -1.3, -1.5, and -1.6% for the dose rate of 200, 300, 400, 500, 600 MU/min, respectively (for 100 MU/min reference), +0.9, +0.3, +0.1, -0.2, and -0.2% for the dose rate of 100, 200, 300, 500, 600 MU/min, respectively (for 400 MU/min reference) and +1.4, +0.8, +0.5, +0.3, and +0.2% for the dose rate of 100, 200, 300, 400, 500 MU/min, respectively (for 600 MU/min reference). On the other hand, for the large field plan, the pass-rate differences were -1.3, -1.6, -1.8, -2.0, and -2.4% for the dose rate of 200, 300, 400, 500, 600 MU/min, respectively (for 100 MU/min reference), +2.0, +1.8, +0.5, -1.2, and -1.6% for the dose rate of 100, 200, 300, 500, 600 MU/min, respectively (for 400 MU/min reference) and +1.5, +1.9, +1.7, +1.9, and +1.2% for the dose rate of 100, 200, 300, 400, 500 MU/min, respectively (for 600 MU/min reference). In short, the dose difference of dose-rate variation was measured to the -2.4~+2.0%. Conclusion: Using the Varian linear accelerator with 120 MLC, the IMRT dose distribution is differed a little <(${\pm}3%$) even though the dose-rate is changed.

    • PDF

    Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

    • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
      • Progress in Medical Physics
      • /
      • v.26 no.3
      • /
      • pp.160-167
      • /
      • 2015
    • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

    Diagnosis of Obstructive Sleep Apnea Syndrome Using Overnight Oximetry Measurement (혈중산소포화도검사를 이용한 폐쇄성 수면무호흡증의 흡증의 진단)

    • Youn, Tak;Park, Doo-Heum;Choi, Kwang-Ho;Kim, Yong-Sik;Woo, Jong-Inn;Kwon, Jun-Soo;Ha, Kyoo-Seob;Jeong, Do-Un
      • Sleep Medicine and Psychophysiology
      • /
      • v.9 no.1
      • /
      • pp.34-40
      • /
      • 2002
    • Objectives: The gold standard for diagnosing obstructive sleep apnea syndrome (OSAS) is nocturnal polysomnography (NPSG). This is rather expensive and somewhat inconvenient, however, and consequently simpler and cheaper alternatives to NPSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. In this study, we have evaluated whether oximetry alone can be used to diagnose or screen OSAS. The diagnostic performance of an analysis algorithm using arterial oxygen saturation ($SaO_2$) base on 'dip index', mean of $SaO_2$, and CT90 (the percentage of time spent at $SaO_2$<90%) was compared with that of NPSG. Methods: Fifty-six patients referred for NPSG to the Division of Sleep Studies at Seoul National University Hospital, were randomly selected. For each patient, NPSG with oximetry was carried out. We obtained three variables from the oximetry data such as the dip index most linearly correlated with respiratory disturbance index (RDI) from NPSG, mean $SaO_2$, and CT90 with diagnosis from NPSG. In each case, sensitivity, specificity and positive and negative predictive values of oximetry data were calculated. Results: Thirty-nine patients out of fifty-six patients were diagnosed as OSAS with NPSG. Mean RDI was 17.5, mean $SaO_2$ was 94.9%, and mean CT90 was 5.1%. The dip index [4%-4sec] was most linearly correlated with RDI (r=0.861). With dip index [4%-4sec]${\geq}2$ as diagnostic criteria, we obtained sensitivity of 0.95, specificity of 0.71, positive predictive value of 0.88, and negative predictive value of 0.86. Using mean $SaO_2{\leq}97%$, we obtained sensitivity of 0.95, specificity of 0.41, positive predictive value of 0.79, and negative predictive value of 0.78. Using $CT90{\geq}5%$, we obtained sensitivity of 0.28, specificity of 1.00, positive predictive value of 1.00, and negative predictive value of 0.38. Conclusions: The dip index [4%-4sec] and mean $SaO_2{\leq}97%$ obtained from nocturnal oximetry data are helpful in diagnosis of OSAS. CT90${\leq}$5% can be also used in excluding OSAS.

    • PDF