• Title/Summary/Keyword: standard measurement

Search Result 3,530, Processing Time 0.034 seconds

A Study on Exposure to radiation of the patient who visited an emergency room at a University Hospital (한 대학병원 응급실에 방문한 환자의 방사선 피폭에 관한 연구)

  • Ahn, Buyung-Ju;Lee, Sang-Bock;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.23-34
    • /
    • 2007
  • To find how much radiation was exposed the patients who visit emergency room, a measurement study was made for radiation amount toward 200 patients selected randomly among visitors to an emergency room in a university hospital from March 16 to 31st, 2006. The results are as follows ; 1. Among the subjects 50 person(25.0%) were transferred from other hospitals, 24 persons(8.3) come after traffic accident, 50 persons for other accident and 76 persons for general medical care. 2. The average frequency of X-ray taking was calculated as 6.4 time per person among transferred patients, 14.5 times per person among patients with traffic accident and 2.6 times per person among general medical care. 3. The radiation exposure amount by kind of X-ray showed 28.9mGyfor general X-ray diagnosis, 84.2mGy for CT scanning and 1.02mGy for other special radiation study. 4. Average radiation exposure amount was calculated as 24.6mGy by transferred patients, 55.2mGy by patients with traffic accident, 17.1mGy by patients with other accidents and 17.0mGy by general patients. 5. Through the comparison of radiation exposure amount among to subject with maximum allowance threshold by International Commission on X-ray Radium Protection, transferred patients exceeded 6 times than allowance in whole body except extremities and joints, blood forming organ, reproductive system, vitreous body of eye, bone, thyroid gland, skin and etc, Patient suffered from traffic accidents were exposed 10 times more than allowance. In conclusion, the radiation exposure amount during X-rat diagnosis re too much and exceeded allowance standard by International Commission on X-ray Radium Protection. So further study and preventive measure to decrease radiation exposure by patients who visit emergency room.

  • PDF

Determination of plasma C16-C24 globotriaosylceramide (Gb3) isoforms by tandem mass spectrometry for diagnosis of Fabry disease (패브리병(Fabry) 진단을 위한 혈장 중 Globotriaosylceramide (Gb3)의 탠덤매스 분석법 개발과 임상 응용)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Yoo, Han-Wook;Choi, Jin-Ho;Lee, Dong-Hwan;Zhang, Kate;Keutzer, Joan
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.45-52
    • /
    • 2007
  • Purpose : A simple, rapid, and highly sensitive analytical method for Gb3 in plasma was developed without labor-ex tensive pre-treatment by electrospray ionization MS/ MS (ESI-MS/MS). Measurement of globotriaosy lceramide (Gb3, ceramide trihex oside) in plasma has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. Methods : Only simple 50-fold dilution of plasma is necessary for the extraction and isolation of Gb3 in plasma. Gb3 in diluted plasma was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Results : Eight isoforms of Gb3 were completely resolved from plasma matrix. C16:0 Gb3 occupied 50% of total Gb3 as a major component in plasma. Linear relationship for Gb3 isoforms w as found in the range of 0.001-1.0 ${\mu}g$/mL. The limit of detection (S/N=3) was 0.001 ${\mu}g$/mL and limit of quantification was 0.01 ${\mu}g$/mL for C16:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9678 to 0.9982. Conclusion : This quantitative method developed could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

  • PDF

Determination of Representative Renal Depth for Accurate Attenuation Correction in Measurement of Glomerular Filtration Rate in Transplanted Kidney (이식 신의 사구체 여과율 측정에서 정확한 감쇄 보정을 위한 신장 깊이 대표값 설정)

  • Oh, Soon-Nam;Kim, Sung-Hoon;Rha, Sung-Eun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Lee, Sung-Young;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.271-276
    • /
    • 2002
  • Purpose: To measure reliable glomerular filtration rate by using the representative values of transplanted renal depths, which are measured with ultrasonography. Materials and Methods: We included 54 patients (26 men, 28 women), with having both renal scintigraphy and ultrasonography after renal transplantation. We measured GFR with Gates' method using the renal depth measured by ultrasonography, and median and mean ones in each patient. We compared GFR derived from ultrasonography-measured renal depth with GFR derived from median and mean renal depths. The correlation coefficients were obtained among GFR derived from ultrasonography-measured renal depths, median and mean renal depths under linear regression analysis. We determined whether GFR derived from median or mean renal depth could substitute GFR derived from ultrasonography-measured renal depth with Bland-Altman method. We analyze the expected errors of the GFR using representative renal depth in terms of age, sex, weight, height, creatinine value, and body surface. Results: The transplanted renal depths range from 3.20 cm to 5.96 cm. The mean value and standard deviation of renal depths measured by ultrasonography are $4.09{\pm}0.65cm$ in men, and $4.24{\pm}0.78cm$ in women. The median value of renal depths measured by ultrasonography is 4.36 cm in men and 4.14 cm in women. The GFR derived from median renal depth is more consistent with GFR derived from ultrasonography-measured renal depth than GFR derived from mean renal depth. Differences of GFR derived from median and ultrasonography-measured renal depth are not significantly different in the groups classified with creatinine value, age, sex, height, weight and body surface. Conclusion: When median value is adapted as a representative renal depth, we could obtain reliable GFR in transplanted kidney simply.

A Comparative Study of Blood Lead Measurement by Polarized Zeman Effect Correction AAS and D2 Correction AAS Method (편광 Zeeman 보정 및 D2 보정 방법에 의한 혈중연 측정치의 비교 연구)

  • Lee, Seok Ki;Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • Blood lead assay by $D_2$ lamp background correction method of atomic absorption spectrophotometer(AAS) with wavelength of 283.3 nm is most popular in occupational health practice in Korea. On the other hand, $D_2$ lamp background correction method with wavelength of 217.0 nm is also often used in general chemical analysis for lead assay in general purpose. But both methods have some weakness of background correction which brought direct effect on the results of analysis. Recently blood lead assay with polarized Zeeman effect of AAS was introduced and is now preferred in many laboratory than $D_2$ correction method in blood lead analysis. But still AAS with $D_2$ lamp are widely used in the field of occupational health in Korea. This study compared blood lead assay data with $D_2$ correction methods(283.3 and 217.0 nm) and with that of polarized Zeeman effect correction method to evaluate the validity of 02 correction methods. The results obtained were as follows; 1. Taking the value of polarized Zeeman effect method as reference value of 1.00, the mean relative value of $D_2$ correction method with wavelength of 217.0 nm was 0.92 and that with wavelength of 283.3 nm was 0.90 respectively in the analysis of blood lead whose value were below $20.0{\mu}g/dl$(p<0.001). Both mean values were statistically smaller than polarized Zeeman effect correction method. But in the analysis of blood whose value were between 20.0 to $20.0{\mu}g/dl$, the mean relative value of $D_2$ correction method was 0.96 in both wavelength and did not differ from polarized Zeeman effect method(p<0.001). There was no difference of blood lead between $D_2$ correction method and polarized Zeeman effect method in the analysis of blood lead whose value were over $40.0{\mu}g/dl$. 2. The variations of background correction value in polarized Zeeman effect method were not changed by increase of blood lead, but those in $D_2$ correction methods were increased by the increase of blood lead. While then relative standard deviation(RSD) of data measured by Zeeman effect method were decreased by the increase of blood lead, those by $D_2$ methods were nol differed by the increase of blood lead.

  • PDF

A Study on Primigravida's Antenatal Self-Care Behavior and Maternal Knowledge (초임부의 산전 자가간호 행위와 모성관련 지식에 관한 연구)

  • Park, Mi-Sook;Kim, Hae-Won
    • Women's Health Nursing
    • /
    • v.6 no.1
    • /
    • pp.153-165
    • /
    • 2000
  • The antenatal self-care, one of antenatal management, was almost done by a pregnant woman herself. But It's especially difficult for primigravidas to cope with the change of being pregnant, and they also had insufficient knowledge of pregnancy, The purpose of this study was to serve as a basis for antenatal management, by grasping how much primigravidas performed antenatal self-care, how much they had maternity-related knowledge, and what factors affected those two factors. The subjects of this study were the primigravidas, selected from among visitors to a general hospital and a hospital for obstetrics and gynecology located in the city of K. A questionnaire survey was carried out over them from July 16 to August 19, 1998, to collect data. The test instrument used in this study for antenatal self-care behavior was one that modified the measurement instrument employed in studies by Kim Hae Won(1996), Lee Mi La(1984), and Yoon Young Mi(1994). Another one for maternity-related knowledge was Kim, Hae Won(1996)'s instrument. The collected data were statistically analyzed by SAS PC+. Frequency and percentage were calculated to find out the primigravidas' general characteristics, and the mean and standard deviation, rank were estimated to determine the degrees of antenatal self-care behavior and maternity-related knowledge, t-test and ANOVA were carried out to identify the general characteristic that affected antenatal self-care and maternity-related knowledge. and the relationship of antenatal self-care behavior to maternity-related knowledge was tested by Pearson correlation coefficient. The findings of this study were as follows; First, the age of the subjects ranged from 18 to 37, and their mean age was 26.43. Their mean gestational period was 24.87 weeks. 45% of the subjects were in the third-term pregnancy. Second, their total mean score in antenatal self-care behavior ranged from 94, the highest, to 36, the lowest. Its average score was 63.81(SD 9.98). The total mean score in maternity-related knowledge ranged from 20, the highest, to 1, the lowest, and its average score was 10.91(SD 4.59, 54.55 percent). Third, the general characteristics that gave impact on the primigravidas' antenatal self-care behavior were age, educational background, gestational period, experience of natural miscarriage, and experience of infertility test. A higher score in antenatal self-care behavior was gained by the primigravida group who had better educational background(F=3.29, p=.02), who was in the late stage of pregnancy(F=4.31, p=.01), who experienced a natural miscarriage(t=2.06, p=.04), and who went through a infertility test(t=-2.19, p=.04). Fourth, the general characteristics that had an influence on maternity-related knowledge were identified as the religion, the term of marriage, and the gestational period. A higher score in maternity-related knowledge was got by the primigravida group who had a religion(t=-2.02, p=.04), and who was in the late stage of pregnancy(F=5.77, p=.003). The term of marriage also made a significant difference(F=3.46, p=.02). Fifth, the relationship of the total mean score between antenatal self-care behavior and maternity-related knowledge was found to be at r=.37(p=.0001). In this study, an attempt was made to affirm the subjects' characteristics, the degree of their antenatal self-care behavior, and the extent of their maternity-related knowledge, to confirm what characteristics affected significantly primigravida's antenatal self-care behavior and maternity-related knowledge, and to verify that there was a relationship between the two variables. The meaning of this study might be backed up by the fact that its findings would serve as a basis for primigravida's efficient antenatal management in the future.

  • PDF

Development of Evaluation Indicators of the Records Management Condition of Public Organizations (공공기관의 기록관리현황 평가지표 개발)

  • Jeon, Soo-Jin
    • The Korean Journal of Archival Studies
    • /
    • no.18
    • /
    • pp.3-36
    • /
    • 2008
  • Despite the institutional, organizational, and technological advances in the level of national records management that has occurred during the past several years, there has been no significant change in the condition of records management within individual public institutions, which may be an outset for records management. In order to begin the advance in national records management with overall innovation in records management by public institutions, it is necessary to distinctly set up the direction of innovation and a project to carry out. Also, a person in charge of records management, who is supposed to lead records management in each institution, should share the directions and projects. Against this backdrop, this study aims to define "the evaluation of records management" as a vehicle to establish a common goal for the innovation of records management and the role of a person in charge of records management as well as to develop evaluation indicators that might be applicable to all public institutions. With this aim, the study drew requirements of records management from domestic and overseas cases in the evaluation of records management conditions as well as the laws and standards of records management, and a roadmap for national records management innovation. Then, the study developed evaluation indicators by classifying the requirements according to three areas involving an organizational environment, records management job, and records management in the offices that create and file their own documents. The organizational environment area is concerned with the evaluation of the records management policy and the responsibility of an institution, and the evaluation of human resources and physical environment. The records management business area includes the measurement of the level of jobs, such as the records creation control conducted by the records management authority of each institution, the management of records schedules, the accession, preservation, and appraisal of records and their service, and the monitoring of records management. The area of records management in the offices is composed of the creation, registration, arrangement, and transfer of records as they are intended to be used during the monitoring of records management conditions. The study made it possible to measure all evaluation indicators with a quantitative evaluation method by clearly proposing the standard for objective and accurate evaluation.

Application of microwave water surface current meter for measuring agricultural water intake (농업용수 사용량 계측을 위한 전자파 표면유속계의 적용)

  • Baek, Jongseok;Kim, Chiyoung;Lee, Kisung;Kang, Hyunwoong;Song, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.12
    • /
    • pp.1071-1079
    • /
    • 2020
  • For integrated water management, it is essential to secure basic data such as the amount of agricultural water intake. The river water intake through the intake weir is carried out through the agricultural irrigation canal, and a method for measuring the quantity of water intake is required to suit the characteristics of the measuring points. In this study, the accuracy of the calculated flow data was determined by applying a microwave water surface current meter. The microwave water surface current meter is a method of calculating surface velocity using doppler effect, which is mainly used in high-velocities situations such as flood. Surface velocity is difficult to represent the average velocity of the entire section at low dicharges or high wind speeds, it is considered to be low in continuous utilization throughout the year, and it is necessary to verify whether the measurement using an microwave water surface curren meter is appropriate in agricultural irrigation canal. The data measured with an microwave water surface curren meter were compared with the actual flow data to calculate the intake data in agricultural irrigation canal. In agricultural irrigation canal, the low-level discharge calculated using an microwave water surface current meter at a minimum velocity of about 0.3 m/s and a minimum discharge of about 1.0 m3/s or higher was found to have a high tendency and accuracy compared to the standard discharge, especially when the high discharge was high. Although effective results can be obtained in terms of quantity at low discharge, it is deemed that subsequent studies are needed to calculate the average discharge of the cross section at low discharge, given that the trend of data is unstable. Through this study, it is suggested that it is appropriate to calculate the amount of water intake through the microwave water surface current meter in artificial waterways with a certain discharge or higher, so it is expected to be widely distributed as a method for measuring river water intake.

A Study on the Proposal for Extension of Local Autonomy and Financial Atonomy of Local Education

  • Park, Jong-Ryeol;Noe, Sang-Ouk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.3
    • /
    • pp.155-165
    • /
    • 2021
  • The measures to extend local education autonomy are as follows: First, it is necessary to correct the confusion of the legal system of the local education autonomy system. For this, Article 12, Paragraph 2 and 4 of the 「Special Act on Local Autonomy and Decentralization, and Restructuring of Local Administrative Systems」 which state that "The State shall endeavor to consolidate systems for autonomy in education and local government" and "The implementation of autonomy in education and the autonomous police system shall be prescribed separately by Acts" should be deleted. Second, it is necessary to clarify unnecessary legal matters and regulatory measures for unification at the national level and to proactively consider the introduction of the legal trust system, in which education affairs are designated as local governments' own work and the state carries out specific affairs. The decentralization of local education finance is a key factor for the development of local education autonomy, and it requires the transfer of authority and resources to the region, and the enhancement of local autonomy and corresponding responsibility. First, the ratio of special grants must be adjusted further (from 3% to 2%) or the ratio of national policy projects must be lowered. Second, the provision that requires a consultation with a mayor/governor when making a budget covered by transfers from general accounts should be deleted. Third, it is necessary to remove the elements that limit the authority of city and provincial councils. Fourth, it is necessary to integrate the national education tax and the local education tax to create the education autonomy tax (tentative name) for only one independent purpose. Fifth, it is necessary to strengthen the distribution of the total amount of grants and abolish the settlement regulations for the measurement items of standard financial demand. Sixth is the expansion of the participation of stakeholders and experts in the grant distribution process. Seventh, it is necessary to establish a long-term employment system by designating the education finance field as a special field. Eight is the expansion of cooperative governance.

Evaluation of the Accuracy and usability of Trigger mode in Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 Trigger mode 투시영상 획득 시 호흡 속도에 따른 정확성 평가 - Phantom Study)

  • Park, je wan;Kim, min su;Um, ki cheon;Choi, seong hoon;Song, heung kwon;Yoon, in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.25-33
    • /
    • 2021
  • Purpose : The purpose of this study is to evaluate the accuracy and usefulness of the Trigger mode for the Respiratory Gated Radiation Therapy (RGRT) Materials and methods : A QUASAR respiratory phantom that inserted a 3 mm fiducial marker (a gold marker) was used to estimate the accuracy of the Trigger mode. And the 20 bpm was used as reference respiration rate in this study. The marker that placed at the center of the phantom was contoured, and the lower threshold of a gating window was fixed at 2.0 mm using an OBI with Truebeam STxTM. The upper threshold was measured every 0.5 mm from 1.0 mm to 3.0 mm. The respiration rates were changed every 10 bpm from 10 bpm to 60 bpm. We repeatedly measured five times to check the error rate of the trigger mode in the same condition. Result : The differences of a distance from a peak phase to upper threshold, 1.0 to 3.0 mm at a 20 bpm as a reference for 3 days in a row were 0.68±0.05 mm, 0.91±0.03 mm, 1.23±0.03 mm, 1.42±0.04 mm, and 1.66±0.06 mm, respectively. Measurement result of changes in respiratory rate compared to baseline respiratory rate in maximum absolute difference. The coefficient of determination (R2) to estimate the correlation between the respiration velocity and variation of absolute difference was on average 0.838, 0.887, 0.770, 0.850, and 0.906. The p-values of all the variables were below 0.05. Conclusion : Using Trigger mode during respiratory gated radiation therapy (RGRT), accuracy and usefulness of trigger mode at reference breathing rate were confirmed. However, inaccuracies depending on the rate of breathing it could be uncertain in case of respiration rate is faster than 20 bpm as a standard respiration rate compared to slower than 20 bpm. Consequently, when conducting a RGRT using the trigger mode, real time monitoring is required with well educated respiration.

GOCI-II Based Low Sea Surface Salinity and Hourly Variation by Typhoon Hinnamnor (GOCI-II 기반 저염분수 산출과 태풍 힌남노에 의한 시간별 염분 변화)

  • So-Hyun Kim;Dae-Won Kim;Young-Heon Jo
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_2
    • /
    • pp.1605-1613
    • /
    • 2023
  • The physical properties of the ocean interior are determined by temperature and salinity. To observe them, we rely on satellite observations for broad regions of oceans. However, the satellite for salinity measurement, Soil Moisture Active Passive (SMAP), has low temporal and spatial resolutions; thus, more is needed to resolve the fast-changing coastal environment. To overcome these limitations, the algorithm to use the Geostationary Ocean Color Imager-II (GOCI-II) of the Geo-Kompsat-2B (GK-2B) was developed as the inputs for a Multi-layer Perceptron Neural Network (MPNN). The result shows that coefficient of determination (R2), root mean square error (RMSE), and relative root mean square error (RRMSE) between GOCI-II based sea surface salinity (SSS) (GOCI-II SSS) and SMAP was 0.94, 0.58 psu, and 1.87%, respectively. Furthermore, the spatial variation of GOCI-II SSS was also very uniform, with over 0.8 of R2 and less than 1 psu of RMSE. In addition, GOCI-II SSS was also compared with SSS of Ieodo Ocean Research Station (I-ORS), suggesting that the result was slightly low, which was further analyzed for the following reasons. We further illustrated the valuable information of high spatial and temporal variation of GOCI-II SSS to analyze SSS variation by the 11th typhoon, Hinnamnor, in 2022. We used the mean and standard deviation (STD) of one day of GOCI-II SSS, revealing the high spatial and temporal changes. Thus, this study will shed light on the research for monitoring the highly changing marine environment.